WMF 9000S+ Instructions for use

µ
WMF 9000 S+ coffee machine planning information
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF Group GmbH | Eberhardstraße 35 |73312 Geislingen (Steige)
Optional:
Area for lines and hoses (water, waste
water, power) for counter cut out
connection.
For 2,6 –3,8 kW minimum Ø50
For 6,0 –7,0 kW minimum Ø70
TW 10 (Angle valve)
Length 1m
On site
Optional cut out for
grounds through
counter Length 2,5m
Or
Optional: vending unit
Card reader width 130 mm
Coin Checker and coin changer 105 mm
Card reader and coin changer height 500 mm
Optional feet
100 mm
Optional: milk hose through
counter
Coin Checker height 502 mm
Power depends on model 2,6 –3,8 kW
Power depends on model 6,0 –7,0 kW
4x thread M10, screw length
max. 23mm
µ
WMF 9000 S+ coffee machine planning information
Conditions for usage and installation
Any necessary on-site preparatory work for electricity, water and drainage connections at the customer‘s premises
is to be arranged by the machine owner / operator. The work must be carried out by authorised installation
technicians in compliance with general, country-specific and local regulations. The WMF service engineers may
only connect the coffee machine to existing prepared connection points. WMF Service is neither authorised nor
responsible for carrying out any on-site installation work prior to connection.
Dimensions and
empty weight
Width
Height
Depth
Clearance heights
Weight
390 mm
744 mm
598 mm
194 mm Coffee
156 mm Hot water
216 mm hot water without pipe
Approx. 67 kg
Water supply Water supply line
Inlet temperature
Water drain tube
(optional)
3/8 inch hose connector with mains tap, and filter
with 0.2 to 0.25 mm mesh size, on site. At least 0.2 MPa (2 bar) flow
pressure at 2 l/min (standard). Maximum 0.6 MPa (6 bar).
Maximum 35 °C.
Tube a minimum of DN 19, minimum downward slope of 2 cm/m
For use at
altitude above
NN
<2000m
Electrical data Nominal power
rating
2.6 –3.8 kW 6.0 –7.0 kW
Power supply 220–240 V
50 / 60 Hz (1 / N / PE)
380–415 V
50 / 60 Hz (3 / N / PE)
Degree of
protection
IP X0
Protection Class I
Installation
Clearance
For operating, service, and safety reasons the machine should be installed with a clearance
from the building or non-WMF components of not less than 50 mm at the sides and 60 mm
at the back. A minimum working space of 800 mm in front of the coffee machine is
recommended. Clearance of at least 200 mm above the product hopper is recommended. The
height of the installation surface above the floor is at least 850 mm. If the coffee machine
connections are to be run downwards through the counter, please make space for the lines,
which can reduce the usable space below the machine.
If the coffee machine is operated with a water filter the additional space under the machine
depending on the filter size has to be considered. For further information see filter
instructions.
Installation
surface /
water spray
The device must be placed and leveled on a horizontal, sturdy, water-resistant, and
heatproof base. The device must not be cleaned using a water jet. The device must be
installed where it is protected against water spray. The device must not be located on a
surface that is sprayed or cleaned with a water hose, steam jets, steam cleaner, or similar
devices.
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF Group GmbH | Eberhardstraße 35 |73312 Geislingen (Steige)
µ
WMF 9000 S+ coffee machine planning information
Ventilation If the possibility of ventilation is limited, adequate ventilation must be provided. Ventilation
must be designed according to the installation situation. (e.g. machine on legs, active
ventilation, additional air vents / openings in counter area, etc.). Ventilation openings must
not be covered.
Electrical
connection
These specifications for the electrical connection and the standards quoted apply for
connecting the coffee machine in EU countries. It may be necessary to also observe additional
country-specific regulations. Outside the EU countries acceptance of the standards quoted is
to be checked by the legal entity or natural person who wishes to use the coffee machine. The
local power supply must be constructed according to the currently valid IEC 364 (DIN VDE
0100). An isolated ground socket or a country-specific single-phase socket for single-phase
connection, or a 5-pole CEE / CEKON socket per EN 60309 or a country-specific multi-pole
socket for a three-phase connection, must be available near the machine. The sockets are part
of the customer‘s on-site installation. The mains cable must not come into contact with hot
surfaces. If the mains cable for this device is damaged then it must be replaced by our service
personnel or a similarly qualified person, in order to prevent hazards.
Important advice regarding accounting systems:
In case of operation with a card reader an additional and separately fuse-protected
shockproof socket must be installed onsite if necessary depending on type of card reader. The
supplier of the card reader is to be asked for the required fuse protection. In order to prevent
possibly occurring disturbances of our screened data lines by potential equalization currents
between the units, an additional potential equalization according to VDE 0800-2 should be
provided for units connected to an accounting system.
Water supply
and drainage
The water supply must be located close to the machine (max. distance 800 mm). An anytime
easily accessible and sufficiently dimensioned water tap (preferably ball tap) as well as a dirt
filter with mesh size 0,080 mm must be installed below the counter in the water supply.
For connection from below through the counter a cut-out must be made in the hatched area
on-site according to drawing (see top view).
For drinking water with carbonate hardness above 5°dKH (carbonate hardness), a WMF water
filter should be fitted upstream.
If the coffee machine is connected to a drain connection, a funnel siphon must be installed in
the drain pipe.
Please observe that the free drain (funnel siphon with sheet metal angle) is fitted vertically.
This means that it must always be vertical to the water back pressure level that is reached. It
must be fitted in a way that the given gradient of the drain hoses (2%) is observed.
Additionally, the free drain must always be below the drains of the coffee machine and above
the actual drain pipe connections (HT40, HT50 or similar) with respect to its height.
To a funnel siphon with sheet metal angle max. two coffee machines with DN19 hose and
black silicone fabric hose should be connected. Other devices (dishwasher, sink etc.) should be
installed elsewhere.
The free drain incl. hoses must not be exposed to heavy tensile, pressure or torsional load.
Hereby, damage might be caused at the mechanical components of the free drain.
Consequently, its usability may get lost.
The on-site preliminary works for the drainage connection must be commissioned by the
operator of the machine. They must be carried out by concession plumbers in compliance
with the prevailing, national as well as local regulations.
The following drawings serve to illustrate the drains and do not include any other
connections, such as power or water infeed!
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF Group GmbH | Eberhardstraße 35 |73312 Geislingen (Steige)
µ
WMF 9000 S+ coffee machine planning information
Miscellaneous Ambient
temperature
+5 °C to maximum +35 °C
(empty the water system in case of frost).
Heat
dissipation
0.1 kW/h standby mode
3.25 kW /h or 6.40kW/h maximum operation
Maximum
humidity
80 % relative humidity without condensation. Do not use device outdoors.
Continuous
sound
pressure level
(Lpa)
< 70 dB(A)
For more information as the instruction manual , safety data sheets and certificates , see:
http://www.servicecenter.wmf.de/
All information refers to coffee machines/ equipment as standard version. Individual solutions can differ from the
standard version.
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF Group GmbH | Eberhardstraße 35 |73312 Geislingen (Steige)
Overflow edge syphon
Silicone mesh drainage
DN 19 drainage
Metal sheet angle
(included in machines
with Dynamic Milk)
Funnel syphon for
machine connection
Minimum height enables
better draining

Other manuals for 9000S+

2

Other WMF Coffee Maker manuals

WMF 500 User manual

WMF

WMF 500 User manual

WMF espresso User manual

WMF

WMF espresso User manual

WMF 1300 S Configuration guide

WMF

WMF 1300 S Configuration guide

WMF Presto 1400 Series User manual

WMF

WMF Presto 1400 Series User manual

WMF 9450 SERIES User manual

WMF

WMF 9450 SERIES User manual

WMF LONO User manual

WMF

WMF LONO User manual

WMF 150 F User manual

WMF

WMF 150 F User manual

WMF 1200 S Configuration guide

WMF

WMF 1200 S Configuration guide

WMF Presto 1400 Series User manual

WMF

WMF Presto 1400 Series User manual

WMF 9000S+ User manual

WMF

WMF 9000S+ User manual

WMF 10 User manual

WMF

WMF 10 User manual

WMF 9440 Series User manual

WMF

WMF 9440 Series User manual

WMF Presto 1400 Series User manual

WMF

WMF Presto 1400 Series User manual

WMF 5500 Series User manual

WMF

WMF 5500 Series User manual

WMF 2000 S Configuration guide

WMF

WMF 2000 S Configuration guide

WMF AromaOne User manual

WMF

WMF AromaOne User manual

WMF CAFEMAT 3100 Series User manual

WMF

WMF CAFEMAT 3100 Series User manual

WMF Series 8400 bistro User manual

WMF

WMF Series 8400 bistro User manual

WMF combiNation S/S4/ESeries 8600 User manual

WMF

WMF combiNation S/S4/ESeries 8600 User manual

WMF 1500S User manual

WMF

WMF 1500S User manual

WMF Lumero User manual

WMF

WMF Lumero User manual

WMF KUCHENminis Aroma User manual

WMF

WMF KUCHENminis Aroma User manual

WMF 2000 S User manual

WMF

WMF 2000 S User manual

WMF 1200 S Configuration guide

WMF

WMF 1200 S Configuration guide

Popular Coffee Maker manuals by other brands

Melitta Excellent operating instructions

Melitta

Melitta Excellent operating instructions

Nespresso ES 100 Pro user manual

Nespresso

Nespresso ES 100 Pro user manual

Keurig Hot K150P owner's manual

Keurig Hot

Keurig Hot K150P owner's manual

BRAVILOR BONAMAT Mondo TH operating instructions

BRAVILOR BONAMAT

BRAVILOR BONAMAT Mondo TH operating instructions

Bunn Tiger XL Specifications

Bunn

Bunn Tiger XL Specifications

Philips HD7864 user manual

Philips

Philips HD7864 user manual

Gaggia Milano ANIMA CLASS Series operating instructions

Gaggia Milano

Gaggia Milano ANIMA CLASS Series operating instructions

Klarstein Excelsa manual

Klarstein

Klarstein Excelsa manual

DeLonghi ESAM3500 instructions

DeLonghi

DeLonghi ESAM3500 instructions

Curtis CAFEPC2CS10000 user guide

Curtis

Curtis CAFEPC2CS10000 user guide

Stone 4262358530165 User and maintenance manual

Stone

Stone 4262358530165 User and maintenance manual

Philips Saeco Minuta HD8773 operating instructions

Philips

Philips Saeco Minuta HD8773 operating instructions

Rancilio EPOCA E Use and maintenance manual

Rancilio

Rancilio EPOCA E Use and maintenance manual

Dualit Rapido Capsule Machine Instruction manual & guarantee

Dualit

Dualit Rapido Capsule Machine Instruction manual & guarantee

Saeco GranBaristo HD8964 user manual

Saeco

Saeco GranBaristo HD8964 user manual

SEVERIN KA 4752 manual

SEVERIN

SEVERIN KA 4752 manual

OCS 1165112 instruction manual