RTM - 02 TEMPERATURE REGULATOR INSTRUCTION
FEATURES
TECHNICAL DATA
DESCRIPTION
APPEARANCE
RTM-01
Power supply terminals: L, N
Input rated voltage: 230 V~
Rated voltage tolerance: -15 ÷ +10 %
Nominal frequency: 50 / 60 Hz
Rated power consumption: 33 mA
Supply voltage indicator: green LED
NTC sensor terminals: IN, IN
Temperature adjustment range: -10°C ÷ +40°C
Hysteresis: ±1 oC
Relay terminals: 11, 12, 14
Load supply indicator: red LED
Relay contacts parameters: 16A NO/NC 4000 VA AC1
Number of terminal clamps: 7
Section of connecting cables: 0,2 ÷ 2,50 mm2
Ambient temperature range: -20 ÷ 60 oC
Operating position: free
Mounting: TH 35 rail (according to PN PN-EN 60715)
Protection degree: IP20 (PN-EN 60529)
Protection level: II
Overvoltage category: II
Pollution degree: 2
Dimensions: single-module (17,5 mm) 90x17,5x66 mm
Weight: 0,08 kg
Reference standards: PN-EN 60730-1, PN-EN 60730-2-9
PN-EN 61000-4-2,3,4,5,6,11
● Temperaturecontrolinarangeof
-10°C ÷ +40°C,
● ExternalNTCprobe,
● Powersupplyindicator,
● Relaystateindicator,
● Loadcontrolindependenceofambi-
ent temperature,
● Single-modulecasing,
● MountedonTH35rail,
● Relayoutput,maximumload16A.
The RTM-01 temperature regulator is
designed for load control (e.g. heaters,
floor heating systems) in dependence of
ambient temperature, near NTC sensor.
The device is capable of temperature
regulating in the range of -10°C ÷ +40°C
according to the temperature adjusted
by means of a potentiometer on the
unit front panel. The external NTC-03
temperature probe is needed for correct
system operation. The probe is not part
of the set and it is necessary to purchase
it separately. The probe lead is 3 m in
length. It is possible to extend it up to
50 m with 0,2 ÷ 2,5 mm2lead.Donotjoin
theprobes.
The device is designed
for single-phase installa-
tion and must be installed
in accordance with stand-
ards valid in a particular
country.Thedeviceshould
be connected according to
the details included in this operating man-
ual. Installation, connection and control
shouldbecarriedoutbyaqualiedelectri-
cian staff, who act in accordance with the
service manualandthedevicefunctions.
Disassembling of the device is equal with
a loss of guarantee and can cause electric
shock. Before installation make sure the
connection cables are not under voltage.
The cruciform head screwdriver 3,5 mm
should be used to instal the device. Im-
proper transport, storage, and use of the
deviceinuenceitswrongfunctioning.
It is not advisable to instal the device in the
following cases: if any device part is miss-
ingorthedeviceisdamagedordeformed.
In case of improper functioning of the de-
vicecontacttheproducer.
ONthresholdsetting
Supply voltage indicator
Power terminal (L) Power terminal (N)
Relay state indicator
Relay output terminals
(11, 12, 14)
Sensor input terminals
(IN, IN)
NTC probe
ZAMEL Sp.zo.o.
ul.Zielona27,43-200Pszczyna,Poland
Tel.+48(32)2104665,Fax+48(32)2108004