- 1 -
IPS716-2GC-4POE
Industrial PoE Switch User Manual
Shenzhen 3onedata Technology Co., Ltd.
Add: 3/B, Zone 1, Baiwangxin High Technology Industrial park,
Nanshan District, Shenzhen, 518108 China
Tel: +86-755-26702668
Fax: +86-755-26703485
E-mail: sales@3onedata.com
Website: www.3onedata.com
【
Summarize
】
IPS716-2GC-4POE is an industrial grade, managed and
redundancy PoE Ethernet switch. The IPS716-2GC-4POE switch
provides 4 ports Fast Ethernet PoE and 2 ports Combo Gigabit
SFP slots or 10/100/1000Base-T(X) ports. The PoE port supports
POE function (IEEE802.3af/at). It provided some kinds of
advanced network managed function, such as: SW-Ring
redundancy ring network, VLAN, LLDP, Trunking, Quality of
Service, Speed control, port mirroring and fault alarm. SW-Ring
can bring your Ethernet to intelligent redundancy. The -40~75℃
working temperature, can meet all kinds of industrial environment
requirement and provide the solution of the economy.
【
Packing list
】
The industrial PoE switch is shipped with the following items. If
any of these items are missing or damaged, please contact your
customer service representative for assistance.
Industrial PoE switch ⅹ1
User manual ⅹ1
Documentation and software CD ⅹ1
DIN-Rail mounting kit ⅹ1
Warranty card ⅹ1
【
Feature
】
Support IEEE802.3, IEEE802.3u, IEEE802.3x,
IEEE802.3z/ab, IEEE802.1Q, IEEE802.1p, IEEE802.1D/W
Compatible with both IEEE802.3at(30W) and
IEEE802.3af(15.4W)
Supports 2 Gigabit combo ports and 4 Fast Ethernet PoE
ports
SW-Ring ring network patent technology (Fault recovery
time<20ms)
Support RSTP for network redundancy
Support static multicast, IGMP Snooping and LLDP
Support Port based VLAN and IEEE802.1Q VLAN
Support QoS absolutely and opposite priority
Support WEB, SNMP and Telnet configuration
Support port status display, data update.
Industrial grade design, -40~75℃work temperature
IP40 protection grade, DIN rail mounted
【
Panel layout
】
Vertical view and bottom view Rear view
Front view Side view
1. Ground screw
2. Terminal block for relay output
3. Console port
4. Terminal block for power input (PWR1, PWR2)
5. DIP switches
6. DIN-Rail mounting kit
7. Power input P1(P2) LED
8. Relay alarm indicator
- 2 -
9. System running indicator
10. PoE port Link/ACT indicator
11. 10/100M Base-T(x) PoE port
12. Ethernet port Link/ACT indicator
13. Gigabit SFP port of the combo port
14. Gigabit copper port of the combo port
【
Dimension
】
Unit (mm)
【
Power supply input
】
The product top panel provided 4 bit power supply input terminal
block, support DC input. DC power supply input supported
redundancy function, provided PWR1 and PWR2 power input,
can use for single, and can connect 2 separately power supply
system, use 1 pair terminal block connect the device at the same
time. If one of the power systems broke, the device can work
un-interruptible. Built-in overcorrect protection, Reverse
connection protection. Voltage input range is 48VDC (terminal
block defined as: V1-、V1+、V2-、V2+). The power supports
reverse connection protection.
【
Relay connection
】
Relay access terminals in the top panel of the device. Between the
two terminal relay, as an open circuit state in normal non alarm
state, when there is power alarm information to the closed state.
The two terminal block connector are used to detect power failure
and network anomaly. The two wires attached to the Fault
contacts form a closed circuit when the device port connection
disconnect or has lost power supply from one of the DC power
inputs. The user can connect the relay to the lamp indicate or
buzzer alarm to remind the relevant staff.
【
Console port
】
This product provided 1pcs procedure test port based in serial port.
It adopts RJ45 interface, located in top panel, can configure
related command through RJ45 to DB9 female cable.
【
DIP Switch
】
Top panel provided 4 bits DIP switch to do function configure
(ON to enable effective), 1 and 4 keep for future function. 2 is
recovery default factory. 3 is for upgrade. Please power off and
power on when you change the status of DIP switch.
【
Communication connector
】
10/100/1000BaseT(X) Ethernet port
The pinout of RJ45 port display as below, connect by UTP or STP.
The connect distance is no more than 100m. 1000Mbps is used
120Ω of UTP 5e; 100Mbps is used 120Ω of UTP 5; 10Mbps is
used 120Ω of UTP 3, 4, 5.
RJ 45 port support automatic MDI/MDI-X operation. That can
connect the PC, Server, Converter and HUB. Pin 1, 2, 3, 4, 5, 6, 7,
8 Corresponding connections in MDI. 1→3, 2→6, 3→1, 4→7,
5→8, 6→2, 7→4, 8→5, are used as cross wiring in the MDI-X
port of Converter and HUB. In MDI/MDI-X, 100/1000Base-TX
PIN defines is as follows:
PIN MDI MDI-X
1 BI_DA+/TX+ BI_DB+/RX+
2 BI_DA-/TX- BI_DB-/RX-
3 BI_DB+/RX+ BI_DA+/TX+
4 BI_DC+/—BI_DD+/—
5 BI_DC-/—BI_DD-/—
6 BI_DB-/RX- BI_DA-/TX-
7 BI_DD+/—BI_DC+/—
8 BI_DD-/—BI_DC-/—
Note: 10Base-T/100Base-TX, “TX±”transmit data±, “RX±”receive data±,
“—”not use.
10/100Base-T(X) MDI (straight-through cable)
10/100Base-T(X) MDI-X (Cross over cable)
- 3 -
Gigabit MDI (straight-through cable)
Gigabit MDI-X (Cross over cable)
MDI/MDI-X auto connection makes switch easy to use for
customers without considering the type of network cable.
1000BaseSFP fiber port(mini-GBIC)
1000BaseSFP fiber port adopts gigabit mini-GBIC transmission,
can choice different SFP module according to different transfer
distance. Fiber interface must use for pair, TX port is transmit side,
must connect to RX (receive side). The fiber interface support loss
line indicator.
Suppose: If you make your own cable, we suggest labeling the
two sides of the same line with the same letter (A-to-A and
B-to-B, shown as below, or A1-to-A2 and B1-to-B2).
【
LED Indicator
】
LED indictor light on the front panel of product, the function of
each LED is described in the table as below.
System indication LED
LED State Description
PWR
(1~2)
ON Power is being supplied to power
input PWR input
OFF Power is not being supplied to
power input PWR input
RUN
ON/OFF System is not running well
Blinking System is running well
ALM
ON When the alarm is enabled, power
or the port’s link is inactive.
OFF Power and the port’s link is active,
the alarm is disabled.
Link/ACT
(1~4/G1~G2)
ON Port connection is active
OFF Port connection is not active
Blinking Data transmitted
POE
(1~4)
ON The PoE device is connected by
IEEE802.3af/at standard
OFF No PoE power output or no PoE
connected PoE devices
【
Installation
】
Before installation, confirm that the work environment meet the
installation require, including the power needs and abundant
space. Whether it is close to the connection equipment and other
equipments are prepared or not.
1. Avoid in the sunshine, keep away from the heat fountainhead or
the area where in intense EMI.
2. Examine the cables and plugs that installation requirements.
3. Examine whether the cables be seemly or not (less than 100m)
according to reasonable scheme.
4. Power: 48VDC power input
5. Environment: Working temperature: -40~75℃
Storage temperature: -40~85℃
Relative humidity: 5%~95%
DIN Rail Installation
In order to use in industrial environments expediently, the product
adopt 35mm DIN-Rail installation, the installation steps as below:
1. Examine the DIN-Rail attachment
2. Examine DIN Rail whether be firm and the position is
suitability or not.
3. Insert the top of the DIN-Rail into the slot just below the
stiff metal spring.
4. The DIN-Rail attachment unit will snap into place as shown
below.
Wiring Requirements
Cable laying need to meet the following requirements,
1. It is needed to check whether the type, quantity and
specification of cable match the requirement before cable
laying;
2. It is needed to check the cable is damaged or not, factory
records and quality assurance booklet before cable laying;
3. The required cable specification, quantity, direction and
laying position need to match construction requirements, and
cable length depends on actual position;
4. All the cable cannot have break-down and terminal in the
- 4 -
middle;
5. Cables should be straight in the hallways and turning;
6. Cable should be straight in the groove, and cannot beyond the
groove in case of holding back the inlet and outlet holes.
Cables should be banded and fixed when they are out of the
groove;
7. Pigtail cannot be tied and swerved as less as possible.
Swerving radius cannot be too small (small swerving causes
terrible loss of link). Its banding should be moderate, not too
tight, and should be separated from other cables;
8. It should have corresponding simple signal at both sides of the
cable for maintaining.
【
Specification
】
Technology
Standard: Support IEEE802.3, IEEE802.3u, IEEE802.3z/ab,
IEEE802.3x, IEEE802.1Q, IEEE802.1p, IEEE802.1D/W
Protocol: ARP, ICMP, TCP, DNS, HTTP, SW-Ring, Telnet, RSTP,
SNMP, LLDP
Flow control: IEEE802.3x flow control, back press flow control
POE Standard: IEEE802.3af/at
Function
Switch function: SW-Ring, QoS, 802.1QVLAN, RSTP, SNMP,
LLDP, Port Trunking, static multicast filter, port mirroring,
bandwidth management, broadcast storm control, port flow
statistics, upgrade online, up and download configuration file,
user name access system
SW-Ring: Support Single, Couple, Chain, Dual homing
Exchange attribute
100M forward speed: 148810pps
1000M forward speed: 1488100pps
Transmit mode: store and forward
System exchange bandwidth: 7.8G
MAC address table: 8K
Memory: 1M
Interface
Fast Ethernet Port: 10Base-T/100Base-TX auto speed control,
Half/full duplex and MDI/MDI-X auto detect
Gigabit Combo port: 1000Base-X SFP slot or 10/100/1000Base-
T(X)
Console port: RS-232 (RJ45 connector)
Alarm port: 2 bit 7.62mm terminal block, 1 channel relay alarm
output, Current load capacity 1A@24VDC
PoE Pin-out: 1/2(+), 3/6(-)
Transfer distance
Twisted cable: 100M (standard CAT5/CAT5e cable)
Multi-mode: 1310nm, 2Km
Single-mode: 1310nm, 20/40/60Km
1550nm, 80/100/120Km
Power supply
Input Voltage: 48VDC
Type of input: 4 bits 7.62mm terminal block
Support over-current protection: 4.0A (DC)
Support redundant power, reverse connection protection
Consumption
No-load consumption: 5.28W@48VDC
Full-load consumption: 113.4W@48VDC
Single PoE port maximum consumption: 30W@48VDC
Working environment
Working temperature: -40~75℃
Storage temperature: -40~75℃
Relative Humidity: 5%~95 %( no condensation)
Mechanical Structure
Shell: IP40 protect grade, metal shell
Installation: DIN-Rail mounting
Size (W×H×D): 70mm×160mm×130mm
Weight: 1.07kg
Industry Standard
EMI: FCC Part 15, CISPR (EN55022) class A
EMS: EN61000-4-2 (ESD), Level 3
EN61000-4-4 (EFT), Level 3
EN61000-4-5 (Surge), Level 3
Shock: IEC 60068-2-27
Free fall: IEC 60068-2-32
Vibration: IEC 60068-2-6
Certification
CE, FCC, RoHS, UL508 (Pending)
Warranty: 5 years

Other manuals for IPS716-2GC-4POE

1

Other 3One data Switch manuals

3One data SW4485I User manual

3One data

3One data SW4485I User manual

3One data IES5028G-4GS-8GC User manual

3One data

3One data IES5028G-4GS-8GC User manual

3One data IES205G User manual

3One data

3One data IES205G User manual

3One data IES6300 Series User manual

3One data

3One data IES6300 Series User manual

3One data IES318 Series User manual

3One data

3One data IES318 Series User manual

3One data TNS5800D User manual

3One data

3One data TNS5800D User manual

3One data ES1026-2F User manual

3One data

3One data ES1026-2F User manual

3One data IES5028-4GS User manual

3One data

3One data IES5028-4GS User manual

3One data IES6306 Series User manual

3One data

3One data IES6306 Series User manual

3One data IPS7110-2GC-8POE User manual

3One data

3One data IPS7110-2GC-8POE User manual

3One data IES6320 Series User manual

3One data

3One data IES6320 Series User manual

3One data IES6316-8GT8GS-2P48 User manual

3One data

3One data IES6316-8GT8GS-2P48 User manual

3One data IPS716-2GC-4POE User manual

3One data

3One data IPS716-2GC-4POE User manual

3One data IES7120-4GS Series User manual

3One data

3One data IES7120-4GS Series User manual

3One data ICS5000-E24GP4GS User manual

3One data

3One data ICS5000-E24GP4GS User manual

3One data IES2312-8GT2GS2HS-2P48 User manual

3One data

3One data IES2312-8GT2GS2HS-2P48 User manual

3One data IES5028G Series User manual

3One data

3One data IES5028G Series User manual

3One data TNS5800D Series User manual

3One data

3One data TNS5800D Series User manual

3One data ICS5400 Series User manual

3One data

3One data ICS5400 Series User manual

3One data IES206G-2GS User manual

3One data

3One data IES206G-2GS User manual

3One data SW4485 User manual

3One data

3One data SW4485 User manual

3One data IPS7112G-4GS-8GPOE User manual

3One data

3One data IPS7112G-4GS-8GPOE User manual

3One data ICS5530 Series User manual

3One data

3One data ICS5530 Series User manual

3One data TNS5500 Series User manual

3One data

3One data TNS5500 Series User manual

Popular Switch manuals by other brands

AMX Enova AVX-400 Operation/reference guide

AMX

AMX Enova AVX-400 Operation/reference guide

Agilent Technologies Agilent 3499A Quick reference guide

Agilent Technologies

Agilent Technologies Agilent 3499A Quick reference guide

Honeywell XP-4051 installation instructions

Honeywell

Honeywell XP-4051 installation instructions

ENSIM SENSORS ELM Series operating manual

ENSIM SENSORS

ENSIM SENSORS ELM Series operating manual

ATEN ALTUSEN KW1000 quick start guide

ATEN

ATEN ALTUSEN KW1000 quick start guide

Bay Networks 281xSA Using

Bay Networks

Bay Networks 281xSA Using

Stihl connected Box user manual

Stihl

Stihl connected Box user manual

MEN G101 user guide

MEN

MEN G101 user guide

Siemens 3VT9324-4TF30 operating instructions

Siemens

Siemens 3VT9324-4TF30 operating instructions

Inateck HB9003 user manual

Inateck

Inateck HB9003 user manual

Dell S4820T Configuration guide

Dell

Dell S4820T Configuration guide

Siemens Sirius 3RT105 Series Assembly instructions

Siemens

Siemens Sirius 3RT105 Series Assembly instructions

PNI SmartHome SM433 user manual

PNI

PNI SmartHome SM433 user manual

Ubiquiti UniFi USW-Pro-24-POE quick start guide

Ubiquiti

Ubiquiti UniFi USW-Pro-24-POE quick start guide

DOTLUX 5180 user manual

DOTLUX

DOTLUX 5180 user manual

Extron electronics SW2 VGA DA2 A Specifications

Extron electronics

Extron electronics SW2 VGA DA2 A Specifications

CityGrow Systems CG130 Series user manual

CityGrow Systems

CityGrow Systems CG130 Series user manual

Epygi QX50 Quick installation guide

Epygi

Epygi QX50 Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.