manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3One data
  6. •
  7. Switch
  8. •
  9. 3One data IES2005-5T-P48 User manual

3One data IES2005-5T-P48 User manual

IES2005-5T-P48
Unmanaged Industrial Ethernet
Switch Quick Installation Guide
3onedata Co., Ltd.
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District,
Shenzhen
Website:
www.3onedata.com
Tel:
+86 0755-26702688
Fax:
+86 0755-26703485
【Package checklist】
Please check whether the package and accessories are intact
while using the switch for the first time.
1.
Industrial Ethernet switch
2.
Certification
3.
Quick installation guide
4.
Warranty card
5.
DIN-Rail mounting attachment
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
This product is full 100M unmanaged DIN-Rail industrial
Ethernet switch. The model is IES2005-5T-P48 (5 100M
copper ports + 1 12~48VDC power supply)
【Panel design】
Rear view, bottom view and top view
Front view and side view
1. DIN-Rail mounting kit
2. Power supply input terminal block
3. DIP switch
4. Grounding screw
5. Power supply input status indicator PWR
6. Copper port connection indicator
7. 100M Ethernet copper port
【Mounting Dimension】
Unit: mm
Attention before mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【DIN-Rail Mounting】
For convenient usage in industrial environments, the product
adopts 35mm DIN-Rail mounting, mounting steps as below:
Step 1 Check whether the DIN-Rail mounting kit that
comes with the device is installed firmly.
Step 2 Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3 Check and confirm the product is firmly installed on
DIN-Rail, and then mounting ends.
【Disassembling DIN-Rail】
Step 1 Power off the device.
Step 2 After lift the device upward slightly, first shift out the
top of DIN-Rail mounting kit, and then shift out the
bottom of DIN-Rail, disassembling ends.
Attention before powering on:
Power ON operation: first connect power line to the
connection terminal of device power supply, and then
power on.
Power OFF operation: first unpin the power plug, and
then remove the power line, please note the operation
order above.
【Power Supply Connection】
DC power supply
This series provide 3-pin 5.08 pitch power
input terminal blocks. Power supply range:
12~48VDC
【DIP Switch Settings】
It provides 4-pin DIP switch for function settings,
among which “ON” is enable valid end.
The definitions of DIP switch are as follows:
DIP
Definition
Operation
1
Loop detection
Set the DIP switch to ON to
enable the loop detection
function.
2
Storm suppression
Set the DIP switch to ON to
enable the storm suppression
function.
3
One-key VLAN
Set the DIP switch to ON to
DIP
Definition
Operation
enable VLAN function, port 1
can communicate with other
ports, while other ports are
isolated from each other.
4
Flow control
Set the switch to ON to enable
the flow control function
【Checking LED Indicator】
The function of each LED is described in the table as below:
LED
Status
Description
PWR
ON
Power supply is connected and
running normally
OFF
Power supply is disconnected
and running abnormally.
Link/ACT
(1-5)
ON
Ethernet port connection is
active.
Blinking
Data transmitted
OFF
Ethernet port connection is
inactive.
【Specification】
Panel
100M copper port
10/100Base-T(X) self-adapting
RJ45 port, full/half duplex
self-adaption, support
MDI/MDI-X self-adaption
Indicator
Power indicator, interface
indicator
Exchange attributes
Backplane bandwidth
1G
MAC table size
2K
Power supply
Input power supply
12~48VDC
Access terminal
3 pins 5.08mm pitch terminal
blocks
Support anti-reverse connection
and over-current protection
Consumption
No-load
0.4W@24VDC
Full-load
1.0W@24VDC
Environmental Limits
Working temperature
-40~75℃
Storage temperature
-40~85℃
Working humidity
5%~95% (no condensation)
Protection grade
IP40 (metal shell)

Other 3One data Switch manuals

3One data ES1026-2F User manual

3One data

3One data ES1026-2F User manual

3One data IES6316-8GT8GS-2P48 User manual

3One data

3One data IES6316-8GT8GS-2P48 User manual

3One data IES2100SL Series User manual

3One data

3One data IES2100SL Series User manual

3One data SW4485 User manual

3One data

3One data SW4485 User manual

3One data ES209G-1GF User manual

3One data

3One data ES209G-1GF User manual

3One data IES5028-4GS User manual

3One data

3One data IES5028-4GS User manual

3One data IES615-2DI(3IN1) Series User manual

3One data

3One data IES615-2DI(3IN1) Series User manual

3One data SW4485I User manual

3One data

3One data SW4485I User manual

3One data IES6306 Series User manual

3One data

3One data IES6306 Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES716-2GS User manual

3One data

3One data IES716-2GS User manual

3One data IES206 Series User manual

3One data

3One data IES206 Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES3000 Series User manual

3One data

3One data IES3000 Series User manual

3One data ICS5428 Series User manual

3One data

3One data ICS5428 Series User manual

3One data IPS3110 Series User manual

3One data

3One data IPS3110 Series User manual

3One data IES615-2DI Series User manual

3One data

3One data IES615-2DI Series User manual

3One data PS1005G-1GT-4POE Operating and maintenance instructions

3One data

3One data PS1005G-1GT-4POE Operating and maintenance instructions

3One data IES1024 Series User manual

3One data

3One data IES1024 Series User manual

3One data TNS5500D Series User manual

3One data

3One data TNS5500D Series User manual

3One data IES205 Manual

3One data

3One data IES205 Manual

3One data IES7120G Series User manual

3One data

3One data IES7120G Series User manual

3One data IES2220 Series User manual

3One data

3One data IES2220 Series User manual

Popular Switch manuals by other brands

Dynex DX-PT413 Quick setup guide

Dynex

Dynex DX-PT413 Quick setup guide

Sonoff TX Series user manual

Sonoff

Sonoff TX Series user manual

Avaya 8800 Series Troubleshooting

Avaya

Avaya 8800 Series Troubleshooting

QSFPTEK S7300-48TE4X2Q quick start guide

QSFPTEK

QSFPTEK S7300-48TE4X2Q quick start guide

HYDROMETER IZAR CENTER 60 Installation

HYDROMETER

HYDROMETER IZAR CENTER 60 Installation

Munters SY Series instruction manual

Munters

Munters SY Series instruction manual

Axis T8504-E user manual

Axis

Axis T8504-E user manual

Azbil VCL-5 Series user manual

Azbil

Azbil VCL-5 Series user manual

MaxTech HX-5 user guide

MaxTech

MaxTech HX-5 user guide

Atlona AT-HD-SC-500 user manual

Atlona

Atlona AT-HD-SC-500 user manual

DeDietrich Gas 310 Eco Series installation manual

DeDietrich

DeDietrich Gas 310 Eco Series installation manual

Steren USB-537 instruction manual

Steren

Steren USB-537 instruction manual

Juniper Day One+ manual

Juniper

Juniper Day One+ manual

HomeMatic HmIP-BS2 Installation instructions and operating manual

HomeMatic

HomeMatic HmIP-BS2 Installation instructions and operating manual

Dell Console Switch user guide

Dell

Dell Console Switch user guide

MEN Mikro Elektronik NM30 user manual

MEN Mikro Elektronik

MEN Mikro Elektronik NM30 user manual

HP 6125XLG Command reference

HP

HP 6125XLG Command reference

Eaton P1 /E Instruction leaflet

Eaton

Eaton P1 /E Instruction leaflet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.