TNS5800 Series
Managed Rack-mounted Industrial
Ethernet Switch Quick Installation
Guide
3onedata Co., Ltd.
【Package Checklist】
Please check whether the package and accessories are intact
while using the switch for the first time.
1.
Industrial Ethernet switch
2.
CD
3.
Quick installation guide
4.
Certification
5.
Warranty card
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
The series of product is layer 3 managed rack-mounted
industrial Ethernet switch designed for rail transit industry.
The models are:
Model I. TNS5800-4GT-8T-P110 (4 Gigabit copper ports + 8
100M copper ports+110VAC/DC(100~240VAC/DC)
power supplies)
Model II. TNS5800-20GT-2P110(20 Gigabit copper ports +2
110VAC/DC power supplies)
Model III. TNS5800-20GT-2P24(20 Gigabit copper ports +2
24VDC power supplies)
【Panel Design】
Front view
Model I
1. Hanger
2. Grounding screw
3. Relay alarm output terminal block
4. Power input terminal block
5. Power supply indicator (PWR)
6. Running indicator (RUN)
7. Alarm indicator (ALARM)
8. Console port
9. 100M copper port (M12)
10. 100M copper port connection indicator
11. Gigabit copper port (M12)
12. Gigabit copper port connection indicator
Model II Model III
1. Hanger
2. Power supply port
3. Grounding screw
4. Gigabit copper port (M12, group G17 G18
bypass,group G19 G20 bypass)
5. Restore factory setting button
6. Console port
7. Link/Act indicator
8. Power supply indicator (P1,P2)
9. Alarm indicator (ALM)
10. Running indicator(RUN)
Rear view
Left view
Right view
【Mounting Dimension】
Unit: mm
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District,
Shenzhen
Website:
www.3onedata.com
Tel:
+86 0755-26702688
Fax:
+86 0755-26703485
Attention before mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Rack-mounting the Device】
Step 1 Select the device installation location to reserve
sufficient size.
Step 2 Adopt screws to install the mounting lugs in the
device position as figure below.
Step 3 Place the device in the rack; adopt 4 screws to
install the mounting lugs on the left and right side in
the rack.
Step 4 Check and confirm the product is firmly installed on
the rack, then mounting ends.
【Rack-mounting Device Disassembling】
Step 1 Power off the device.
Step 2 Unscrew the fixing screw of mounting lug on the
rack.
Step 3 Remove the device from the rack, disassembling
ends.
Note:
Power ON operation: first connect power line to the
connection terminal of device power supply, then power
on.
Power OFF operation: first unpin the power plug, then
remove the power line, please note the operation order
above.
【Power Supply Connection】
Model I Model I provides 3-Pin 5.08mm pitch power
supply terminal blocks. Power supply range:
110VAC/DC (100-240VAC/DC).
Model II Model III
Model II model III provide 7-Pin M23 power
supply port. Pin 1 and Pin 2 are power
supply P1(Pin 1 is V+,Pin2 is V-); Pin 3 and
Pin 4 are power supply P2(Pin 3 is V+,Pin 4
is V-);Pin 6 is ground. Model II power supply
range: 110VAC/DC(100~240VAC/DC),
Model III power supply range: 24VDC.
【Relay Connection】
Model I This device provides 3-Pin 5.08mm pitch
relay terminal blocks. Relay terminal blocks
is a pair of normally open contacts of
device alarm relay. They are open circuit in normal non alarm
state, closed when any alarm information occurs. Such as: it's
closed when power off, and send out alarm. This series
switches support 1 channel relay alarm information output,
support DC power alarm information or network abnormal
alarm output, it can be connected to alerting lamp, alarm
buzzer, or other switching value collecting devices for timely
warning operating staffs when alarm information occurs.
Model II Model III
Model II Model III provide 7-Pin M23 port in
which Pin 5 and Pin 7 are relay pins. Relay is
a pair of normally open contacts of device
alarm relay. They are open circuit in normal
non alarm state, closed when any alarm
information occurs. Such as: it's closed when
power off, and send out alarm. This series switches support 1
channel relay alarm information output, support DC power
alarm information or network abnormal alarm output, it can be
connected to alerting lamp, alarm buzzer, or other switching
value collecting devices for timely warning operating staffs
when alarm information occurs.
Communication Interface Connection
M12 100M Copper Port
Model I provides 8 10/100Base-T(X) ports. The
interface type is M12 D-Coded 4-Pin slot (female).
The pin definitions of M12 are as follows:
No.
Definition
Description
1
TD+
100M Ethernet transmitted signal
Positive
2
TD-
100M Ethernet transmitted signal
Negative
3
RD+
100M Ethernet received signal
Positive
4
RD-
100M Ethernet received signal
Negative
M12 Gigabit Copper Port
Model I provides 4 10/100/1000Base-T(X)
interfaces. The interface type is M12 A-Coded
8-Pin slot (female) and its pin definitions are
as follows:
No.
Definition
Description
1
D0+ (DA+)
The first group of bi-directional data
of Gigabit Ethernet positive
2
D0- (DA-)
The first group of bi-directional data
of Gigabit Ethernet negative
3
D1+ (DB+)
The second group of bi-directional
data of Gigabit Ethernet positive
4
D1- (DB-)
The second group of bi-directional
data of Gigabit Ethernet negative
5
D3+ (DD+)
The fourth group of bi-directional
data of Gigabit Ethernet positive
6
D3- (DD-)
The fourth group of bi-directional
data of Gigabit Ethernet negative
7
D2- (DC-)
The third group of bi-directional data
of Gigabit Ethernet negative
8
D2+ (DC+)
The third group of bi-directional data
of Gigabit Ethernet positive
Model II Model III provide 20
10/100/1000Base-T(X) interfaces. The
interface type is M12 X-Coded 8-Pin slot
(female) and its pin definitions are as
follows:
No.
Definition
Description
1
BI + (DA+)
The first group of bi-directional data
of Gigabit Ethernet positive
2
BI - (DA-)
The first group of bi-directional data
of Gigabit Ethernet negative
3
BI + (DB+)
The second group of bi-directional
data of Gigabit Ethernet positive
4
BI - (DB-)
The second group of bi-directional
data of Gigabit Ethernet negative
5
BI + (DD+)
The fourth group of bi-directional
data of Gigabit Ethernet positive
6
BI - (DD-)
The fourth group of bi-directional
data of Gigabit Ethernet negative
7
BI - (DC-)
The third group of bi-directional data
of Gigabit Ethernet negative
8
BI + (DC+)
The third group of bi-directional data
of Gigabit Ethernet positive
Console Port Connection
This device provides 1 program debugging port based on
RS232, which could be connected to PC for device CLI
command management. The interface adopts RJ45 port. The
pin definitions of RJ45 are as follows:
No.
2
3
5
Definition
TXD
RXD
GND
【Restoring Factory Settings】
The steps of restoring factory settings of Model II Model III are
as follows: press and hold restore factory setting button to
power on the device again. Release the button after 3-4s to
finish restoring factory settings.
【Checking LED Indicator】
This device provides LED indicators for monitoring the work
status of the device, which has simplified the troubleshooting
process comprehensively. The function of each LED is
described in the table as below:
LED
Status
Description
PWR
ON
PWR is connected and running
normally
OFF
PWR is disconnected and running
abnormally.
ALARM
ON
Power supply, port link alarm
OFF
Power supply, port link without
alarm
RUN
ON
The device is powered on or the
device is abnormal.
OFF
The device is powered off or the
device is abnormal.
Blinking
Blink 1 time/s, system is running
well.
Link/Act
ON
Ethernet port connection is active.
Blinking
Data transmitted
OFF
Ethernet port connection is inactive.
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device’s configuration interface via IE
browser is shown as below:
Step 1 Configure the IP addresses of computer and the
device to the same network segment, and the
network between them can be mutually accessed.
Step 2 Enter device’s IP address in the address bar of the
computer browser.
Step 3 Enter device’s username and password in the login
window as shown below.
Step 4 Click “OK”button to login to the WEB interface of
the device.
Note:
The default IP address of the device is “192.168.1.254”.
The default username and password of the device is
“admin123”.
If the username or password is lost, user can restore it to
factory settings via device DIP switch or management
software; all modified configurations will be cleared
after restoring to factory settings, so please backup
configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【Specification】
Panel
100M M12
10/100Base-T(X), M12
(Female), 4-Pin D-Coded,
automatic flow control, full/half
duplex mode, MDI/MDI-X
automatic detection
Gigabit M12
10/100/1000Base-T(X),
M12(Female),8-Pin
A-Coded/X-Coded automatic
flow control, full/half duplex
mode, MDI/MDI-X automatic
detection; support Bypass
function
Console port
CLI command management
port, RJ45
Alarm interface
Model I:3-Pin 5.08mm pitch
terminal blocks,
Model II,model III:7-Pin female
M23 portSupport 1 relay alarm
output, the current loading
capability is 5A@30VDC or
10A@125VAC
Indicator
Power indicator, run indicator,
interface indicator, alarm
indicator
Exchange attributes
Backplane bandwidth
128G
Packet buffer size
12Mbit
MAC table size
16K
Power supply
Model I
power supply :110VAC/DC
(100~240VAC/DC)
input terminal: 3-Pin 5.08mm
pitch terminal blocks
Model II
power supply: 110VAC/DC
(dual)
input terminal: 7-Pin female M23
port
Model III
Power supply: 24VDC(dual)
Input terminal: 7-Pin female
M23 port
Consumption
Model I
No-load : 14.30W@110VDC
Full-load : 14.85W@110VDC
Model II
No-load :15.5W@110VDC
Full-load : 17.9W@110VDC
Model III
No-load :13.6W@24VDC
Full-load :16.3W@24VDC
Working environment
Model I
Working temperature : -40~
75℃
Storage temperature : -40~
75℃
Working humidity : 5%~95%(no
condensation)
Protection grade : IP40 (metal
shell)
Model II Model III
Working temperature : -40~
75℃
Storage temperature : -40~
85℃
Working humidity : 5%~95%(no
condensation)
Protection grade :IP40 (metal
shell)

Other 3One data Switch manuals

3One data IES2005 User manual

3One data

3One data IES2005 User manual

3One data PS1005G-1GT-4POE Operating and maintenance instructions

3One data

3One data PS1005G-1GT-4POE Operating and maintenance instructions

3One data IPS7110-2GC-8POE User manual

3One data

3One data IPS7110-2GC-8POE User manual

3One data IES2008 User manual

3One data

3One data IES2008 User manual

3One data IES6300 Series User manual

3One data

3One data IES6300 Series User manual

3One data ICS5530 Series User manual

3One data

3One data ICS5530 Series User manual

3One data TNS5500D Series User manual

3One data

3One data TNS5500D Series User manual

3One data SW4485I User manual

3One data

3One data SW4485I User manual

3One data IES2305 Series User manual

3One data

3One data IES2305 Series User manual

3One data IES5028-4GS-2F User manual

3One data

3One data IES5028-4GS-2F User manual

3One data IPS3110 Series User manual

3One data

3One data IPS3110 Series User manual

3One data IES618 Series User manual

3One data

3One data IES618 Series User manual

3One data IES5028G-4GS-8GC User manual

3One data

3One data IES5028G-4GS-8GC User manual

3One data IES6306 Series User manual

3One data

3One data IES6306 Series User manual

3One data IES7120-4GS Series User manual

3One data

3One data IES7120-4GS Series User manual

3One data IES618-4D Series User manual

3One data

3One data IES618-4D Series User manual

3One data ICS5400PTP-12GT12GS4XS User manual

3One data

3One data ICS5400PTP-12GT12GS4XS User manual

3One data IES7116G-8GS Series User manual

3One data

3One data IES7116G-8GS Series User manual

3One data IES2220 Series User manual

3One data

3One data IES2220 Series User manual

3One data IES5024-20F User manual

3One data

3One data IES5024-20F User manual

3One data IES2010 Series User manual

3One data

3One data IES2010 Series User manual

3One data IES7110-2GS Series User manual

3One data

3One data IES7110-2GS Series User manual

3One data IES6210 Series User manual

3One data

3One data IES6210 Series User manual

3One data ES2010G-2GS User manual

3One data

3One data ES2010G-2GS User manual

Popular Switch manuals by other brands

Zoeller 10-4660 quick start guide

Zoeller

Zoeller 10-4660 quick start guide

HP storageworks 2/32 installation guide

HP

HP storageworks 2/32 installation guide

Pylon Technologies LV-Hub product manual

Pylon Technologies

Pylon Technologies LV-Hub product manual

LEGRAND Wattstopper LMDM-101-R manual

LEGRAND

LEGRAND Wattstopper LMDM-101-R manual

Intellinet 560993 instructions

Intellinet

Intellinet 560993 instructions

HITROL HR-30 instruction manual

HITROL

HITROL HR-30 instruction manual

Korenix JetNet 5710G Series Quick installation guide

Korenix

Korenix JetNet 5710G Series Quick installation guide

Leviton Z-MAX r24sd user guide

Leviton

Leviton Z-MAX r24sd user guide

Accton Technology Edge-Core ES4528V installation guide

Accton Technology

Accton Technology Edge-Core ES4528V installation guide

3Com SWITCH 4050 datasheet

3Com

3Com SWITCH 4050 datasheet

Emerson Rosemount 2460 quick start guide

Emerson

Emerson Rosemount 2460 quick start guide

KTI Networks KS-105F-T installation guide

KTI Networks

KTI Networks KS-105F-T installation guide

Extreme Networks Summit1 Hardware installation guide

Extreme Networks

Extreme Networks Summit1 Hardware installation guide

LevelOne OfficeCon GSW-2440 Specifications

LevelOne

LevelOne OfficeCon GSW-2440 Specifications

Mitel sx-100 user manual

Mitel

Mitel sx-100 user manual

Globalmediapro SM-2C Operation manual

Globalmediapro

Globalmediapro SM-2C Operation manual

Dataprobe IP-28 Series manual

Dataprobe

Dataprobe IP-28 Series manual

Magnetrol B75 Installation and operating manual

Magnetrol

Magnetrol B75 Installation and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.