manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aseptico
  6. •
  7. Dental Equipment
  8. •
  9. Aseptico ADU-07A ECONO AIR SYSTEM Administrator Guide

Aseptico ADU-07A ECONO AIR SYSTEM Administrator Guide

Other Aseptico Dental Equipment manuals

Aseptico ADU-22 Manual

Aseptico

Aseptico ADU-22 Manual

Aseptico ADU-04ST Manual

Aseptico

Aseptico ADU-04ST Manual

Aseptico AEU-25 Manual

Aseptico

Aseptico AEU-25 Manual

Aseptico AMC-20CF Troubleshooting guide

Aseptico

Aseptico AMC-20CF Troubleshooting guide

Aseptico ADC-01 AseptiChair User manual

Aseptico

Aseptico ADC-01 AseptiChair User manual

Aseptico ALU-40LED-CF Manual

Aseptico

Aseptico ALU-40LED-CF Manual

Aseptico ECONO AIR SYSTEM ADU-07 Administrator Guide

Aseptico

Aseptico ECONO AIR SYSTEM ADU-07 Administrator Guide

Aseptico ADU-12DCEB Task Force Deluxe Manual

Aseptico

Aseptico ADU-12DCEB Task Force Deluxe Manual

Aseptico ADU-17X Express II Manual

Aseptico

Aseptico ADU-17X Express II Manual

Aseptico AEU-14CF Troubleshooting guide

Aseptico

Aseptico AEU-14CF Troubleshooting guide

Aseptico AEU-525CF Transport III Troubleshooting guide

Aseptico

Aseptico AEU-525CF Transport III Troubleshooting guide

Aseptico ADC-02CF User manual

Aseptico

Aseptico ADC-02CF User manual

Aseptico AEU-1000-70V User manual

Aseptico

Aseptico AEU-1000-70V User manual

Aseptico AMC-20CF Manual

Aseptico

Aseptico AMC-20CF Manual

Aseptico Command Air ADC-08CF User manual

Aseptico

Aseptico Command Air ADC-08CF User manual

Aseptico Transport III Troubleshooting guide

Aseptico

Aseptico Transport III Troubleshooting guide

Aseptico AEU-27A Manual

Aseptico

Aseptico AEU-27A Manual

Aseptico ADC-09CF User manual

Aseptico

Aseptico ADC-09CF User manual

Aseptico ADC-10 AseptiStool User manual

Aseptico

Aseptico ADC-10 AseptiStool User manual

Aseptico ADU-08SX Sealant Express Manual

Aseptico

Aseptico ADU-08SX Sealant Express Manual

Aseptico AEU-7000L-70V Manual

Aseptico

Aseptico AEU-7000L-70V Manual

Aseptico AEU-6000 User manual

Aseptico

Aseptico AEU-6000 User manual

Aseptico ADU-07A Administrator Guide

Aseptico

Aseptico ADU-07A Administrator Guide

Aseptico AEU-350 User manual

Aseptico

Aseptico AEU-350 User manual

Popular Dental Equipment manuals by other brands

3M ESPE Pentamix Lite operating instructions

3M ESPE

3M ESPE Pentamix Lite operating instructions

ENBIO Enbio S user manual

ENBIO

ENBIO Enbio S user manual

Vatech EzRay Air VEX-P300 user manual

Vatech

Vatech EzRay Air VEX-P300 user manual

KaVo GENTLEpower LUX Contra-angle 25 LP Technician's Instructions

KaVo

KaVo GENTLEpower LUX Contra-angle 25 LP Technician's Instructions

DENTSPLY SmartLite Focus Instructions for use

DENTSPLY

DENTSPLY SmartLite Focus Instructions for use

LM ProPower CombiLED quick guide

LM

LM ProPower CombiLED quick guide

Owandy Radiology RX-AC user manual

Owandy Radiology

Owandy Radiology RX-AC user manual

mectron Piezosurgery Cleaning and sterilization manual

mectron

mectron Piezosurgery Cleaning and sterilization manual

Belmont CREDIA G1 operating instructions

Belmont

Belmont CREDIA G1 operating instructions

Planmeca Sovereign Classic user manual

Planmeca

Planmeca Sovereign Classic user manual

Bego Fornax T operating instructions

Bego

Bego Fornax T operating instructions

Renfert SYMPRO Operating and safety instructions

Renfert

Renfert SYMPRO Operating and safety instructions

Nevadent NZPS 3 A1 operating instructions

Nevadent

Nevadent NZPS 3 A1 operating instructions

Dentatus Nyström instruction manual

Dentatus

Dentatus Nyström instruction manual

OMS DUKE EASY Instruction handbook

OMS

OMS DUKE EASY Instruction handbook

OMS LINEA PATAVIUM Instruction handbook

OMS

OMS LINEA PATAVIUM Instruction handbook

BRYANT DENTAL Ignis Gesture A-494322 manual

BRYANT DENTAL

BRYANT DENTAL Ignis Gesture A-494322 manual

Renfert Basic classic instruction manual

Renfert

Renfert Basic classic instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ADU-07A ECONO AIR SYSTEM
OPERATION
INSTRUCTION MANUAL
2.
Your new Aseptico ADU-07A Econo Air System is one of the
nest handpiece control systems available to the professional.
This economic system provides dental operatories, hygienists’
rooms or satellite o󰀩ces with three automatically activated
handpiece controls — simply lift the handpiece from its holder to
activate.
Congratulations!
This system is engineered to provide many years of reliable
service. Please read the instructions provided in this manual
to receive the best and longest service from your Aseptico
equipment.
INSTALLATION:
Before you install your ADU-07A unit, locate a suitable mounting
surface that has access to a clean, ltered air and water supply.
1. Remove the chassis back from the front by unscrewing the
6-32 x 1/4 holding screws.
2. Use the mounting holes on the back of the chassis as a
marking template and secure the chassis back to a at
vertical surface. Then reattach the front of chassis to the
mounted back. (Fig. 1)
Figure 1 - Chassis Mounting
3. Locate the 1/4” grey air supply line and the blue water
supply line exiting from beneath the ADU-07 console.
Connect the grey air supply line to a clean regulated 60-90
PSI compressed air supply. Connect the blue water supply
line to a clean regulated water source such as the tap water
supply or a remote self-contained water system.(Fig. 2).
BLUE
TO WATER SUPPLY
TO COMPRESSED
AIR SUPPLY
GREY
Figure 2 - Water & Air Connections
WATER FLOW
ON/OFF
SWITCH
Figure 3 - Foot Control
OPERATION FUNCTIONS: (See Fig. 3 & 4)
1. Handpiece Selector - Automatically activates highspeed or
lowspeed handpieces when lifted from their holders.
2. Water On/O󰀨 Toggle - Controls on/o󰀨 ow of water coolant
to the highspeed handpieces.
3. Water Flow Control - Adjusts water coolant ow to the
highspeed handpiece.
4. Pressure Gauge - Provides visual indication of drive air
pressure for the handpiece in use.
5. Drive Air Pressure Control - Adjusts drive air pressure
to the highspeed and lowspeed handpieces. Turn controls
clockwise (with small slot-head screwdriver) to decrease
pressure; counterclockwise to increase pressure.
6. Air/Water Syringe - Delivers air, water, or a combination
mist. Supplied with autoclavable tips.
7. Foot Control w/Water On/O󰀨 Switch -Wet/dry type foot
control provides drive air pressure to the active handpiece.
Apply light foot pressure to any part of the foot control cover.
Toggle Switch provides on/o󰀨 control of water coolant ow to
highspeed handpieces (Fig. 3).
AIR/WATER
SYRINGE
Figure 4 - Console
WATER FLOW
CONTROL
DRIVE AIR
PRESSURE
CONROL
(Underneath
Console)
HANDPIECE
SELECTOR
PRESSURE
GAUGE WATER ON/
OFF TOGGLE
3.
UNIT OPERATION:
1. Handpieces (sold separately) - Connect the proper
highspeed and lowspeed handpieces to their appropriate
connector. Switch the handpiece selector toggle to the
desired handpiece. Depress foot control for operation.
2. 3-Way Air/Water Syringe - Depress the right button
for air operation, and the left button for water operation.
Depressing both buttons will create a mist. The syringe
features quick-change autoclavable tips: To remove a tip,
press on the locking ring surrounding the tip socket and pull
the used tip straight out of the socket (Fig. 4). To insert a
new tip, press locking ring and push tip into socket as far as
it will go. Release ring and gently tug on tip before using to
ensure that tip is securely locked into socket.
Syringe Tip Sterilization:
1. Remove contaminated syringe tip.
2. Remove all visible signs of contamination before
autoclaving.
3. Autoclave tip at 132° C (270° F) for ten minutes.
4. Sterilize between each patient use.
DEPRESS LOCKING
COLLAR
FIG. 4
NOTE: Since only the tips can be autoclaved, it is
recommended that the Air/Water Syringe be bagged with a
disposable, single-use plastic sleeve between each patient
use.
WARRANTY:
Aseptico Inc. warrants its new products against defects in material and
workmanship under normal and proper use, care, and maintenance for
a period of two (2) years from date of original invoice. This two (2) year
warranty does NOT apply nor is it extended to products that are not
manufactured by Aseptico. These products may be covered by a separate
limited warranty provided by the particular manufacturer, and all claims
and questions regarding the same are to be directed to the particular
manufacturer.
Expendable components, such as batteries, fuses, light bulbs, and tubing
sets installed on Aseptico products are specically excluded and have no
warranty. Consumable goods are warranted for the stated expiration date
of such goods.
Repair or replacement of any product(s) or part(s) under this warranty
does not extend the term of this warranty, and such product(s) or part(s)
shall remain covered by the unexpired portion of the warranty period, or
for ninety (90) days from the date of return to Aseptico, whichever is later.
This limited warranty applies only to the initial or rst installation of the
product or part.
During the specic warranty periods set forth above, Aseptico will, at its
option, repair or replace the product(s) or particular part(s) that are found
to be defective in either material or workmanship in part or whole. Aseptico
shall be the sole arbiter of such action. In the event of alleged defect
under warranty, the purchaser is to notify Aseptico’s Customer Service
department promptly. Customer Service will provide Return Material
Authorization (RMA) instructions, usually directing that the product be
returned for service, shipping prepaid by the buyer or end user, to Aseptico
or its designated and authorized warranty service center.
This warranty shall not apply to products (1) that have been subjected to
neglect, abuse, misuse, improper installation, inadequate maintenance, or
damage due to improper use of cleaning materials or chemicals, or non-
compliance with Aseptico’s storage, installation, operation, maintenance
or environmental requirements; (2) that have undergone any modication
or repair not previously authorized by Aseptico in writing, or service, repair
or modication by or from any facility other than an authorized Aseptico
service center or technician, or that use non-authorized software or spare
or replacement parts; or (3) that fail due to reasonable and normal use or
wear and tear, or materials made, furnished or specied by the buyer or
end user.
Aseptico does not assume under this warranty any risks or liabilities
arising from the clinical use of its products, whether or not such use
involves coincidental utilization of products manufactured by others.
Under no circumstances will Aseptico be liable or responsible for special,
compensatory, incidental, consequential or punitive damages, lost prots,
lost sales, or loss of use or loss of business opportunity by or through the
use of the product. Aseptico’s sole and maximum liability with respect to
the product, other than its obligations set forth above, shall be the total
purchase price paid for the product.
P.O. Box 1548 • Woodinville, WA 98072
8333 216th Street SE • Woodinville, WA 98072
(425) 487-3157 • (800) 426-5913
www.aseptico.com • [email protected]
PRINTED IN THE
U.S.A.
P/N: 420424
Rev. E
ECO 15499
04/2022