manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aseptico
  6. •
  7. Dental Equipment
  8. •
  9. Aseptico ECONO AIR SYSTEM ADU-07 Administrator Guide

Aseptico ECONO AIR SYSTEM ADU-07 Administrator Guide

Other Aseptico Dental Equipment manuals

Aseptico AEU-25 Manual

Aseptico

Aseptico AEU-25 Manual

Aseptico ADU-08SX Sealant Express Manual

Aseptico

Aseptico ADU-08SX Sealant Express Manual

Aseptico ADU-40CF Command Air Manual

Aseptico

Aseptico ADU-40CF Command Air Manual

Aseptico AEU-27A Manual

Aseptico

Aseptico AEU-27A Manual

Aseptico VCT AEU-925 Manual

Aseptico

Aseptico VCT AEU-925 Manual

Aseptico AMC-20 Manual

Aseptico

Aseptico AMC-20 Manual

Aseptico AEU-6000-70V Manual

Aseptico

Aseptico AEU-6000-70V Manual

Aseptico AEU-525 Transport III Manual

Aseptico

Aseptico AEU-525 Transport III Manual

Aseptico ADC-01 AseptiChair User manual

Aseptico

Aseptico ADC-01 AseptiChair User manual

Aseptico ADU-03ST Manual

Aseptico

Aseptico ADU-03ST Manual

Aseptico AEU-14CF User manual

Aseptico

Aseptico AEU-14CF User manual

Aseptico ADU-04ST Manual

Aseptico

Aseptico ADU-04ST Manual

Aseptico ADU-22 Manual

Aseptico

Aseptico ADU-22 Manual

Aseptico AEU-1070-70V User manual

Aseptico

Aseptico AEU-1070-70V User manual

Aseptico Task Force Deluxe Manual

Aseptico

Aseptico Task Force Deluxe Manual

Aseptico AEU-525CF Transport III Troubleshooting guide

Aseptico

Aseptico AEU-525CF Transport III Troubleshooting guide

Aseptico ADC-08 User manual

Aseptico

Aseptico ADC-08 User manual

Aseptico AMC-20CF Troubleshooting guide

Aseptico

Aseptico AMC-20CF Troubleshooting guide

Aseptico ADU-07A ECONO AIR SYSTEM Administrator Guide

Aseptico

Aseptico ADU-07A ECONO AIR SYSTEM Administrator Guide

Aseptico AEU-7P Manual

Aseptico

Aseptico AEU-7P Manual

Aseptico AEU-14CF User manual

Aseptico

Aseptico AEU-14CF User manual

Aseptico ADU-17A2 Express Air 2 Manual

Aseptico

Aseptico ADU-17A2 Express Air 2 Manual

Aseptico ALU-40MOM Manual

Aseptico

Aseptico ALU-40MOM Manual

Aseptico AEU-7000E-70V Troubleshooting guide

Aseptico

Aseptico AEU-7000E-70V Troubleshooting guide

Popular Dental Equipment manuals by other brands

3M ESPE Pentamix Lite operating instructions

3M ESPE

3M ESPE Pentamix Lite operating instructions

ENBIO Enbio S user manual

ENBIO

ENBIO Enbio S user manual

Vatech EzRay Air VEX-P300 user manual

Vatech

Vatech EzRay Air VEX-P300 user manual

KaVo GENTLEpower LUX Contra-angle 25 LP Technician's Instructions

KaVo

KaVo GENTLEpower LUX Contra-angle 25 LP Technician's Instructions

DENTSPLY SmartLite Focus Instructions for use

DENTSPLY

DENTSPLY SmartLite Focus Instructions for use

LM ProPower CombiLED quick guide

LM

LM ProPower CombiLED quick guide

Owandy Radiology RX-AC user manual

Owandy Radiology

Owandy Radiology RX-AC user manual

mectron Piezosurgery Cleaning and sterilization manual

mectron

mectron Piezosurgery Cleaning and sterilization manual

Belmont CREDIA G1 operating instructions

Belmont

Belmont CREDIA G1 operating instructions

Planmeca Sovereign Classic user manual

Planmeca

Planmeca Sovereign Classic user manual

Bego Fornax T operating instructions

Bego

Bego Fornax T operating instructions

Renfert SYMPRO Operating and safety instructions

Renfert

Renfert SYMPRO Operating and safety instructions

Nevadent NZPS 3 A1 operating instructions

Nevadent

Nevadent NZPS 3 A1 operating instructions

Dentatus Nyström instruction manual

Dentatus

Dentatus Nyström instruction manual

OMS DUKE EASY Instruction handbook

OMS

OMS DUKE EASY Instruction handbook

OMS LINEA PATAVIUM Instruction handbook

OMS

OMS LINEA PATAVIUM Instruction handbook

BRYANT DENTAL Ignis Gesture A-494322 manual

BRYANT DENTAL

BRYANT DENTAL Ignis Gesture A-494322 manual

Renfert Basic classic instruction manual

Renfert

Renfert Basic classic instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

OPERATION
INSTRUCTION MANUAL
ADU-07 ECONO AIR SYSTEM
Your new Aseptico ADU-07 Econo Air System is one of the finest handpiece control systems
available to the professional. This economical system provides dental operatories, hygienists’
rooms or satellite offices with two manually activated handpiece controls.
Congratulations!
This system is engineered to provide many years of reliable service. Please read the instructions
provided in this manual to receive the best and longest service from your Aseptico equipment.
INSTALLATION:
Before you install your ADU-07 unit, locate a
suitable mounting surface that has access to a
clean, filtered air and water supply.
1. Remove the chassis back from the front by
unscrewing the 6-32 x 1/4 holding screws.
2. Use the mounting holes on the back of the
chassis as a marking template and secure
the chassis back to a flat vertical surface.
Then reattach the front of chassis to the
mounted back. (Fig. 1)
3. Locate the 1/4" grey air supply line and the
blue water supply line exiting from beneath
the ADU-07 console. Connect the grey air
supply line to a clean regulated 60-90 PSI
compressed air supply. Connect the blue
water supply line to a clean regulated
water source such as the tap water supply
or a remote self-contained water system.
(Fig. 2).
Figure 1 - Chassis Mounting
BLUE TO WATER SUPPLY
TO COMPRESSED
AIR SUPPLY
GREY
Figure 2 - Water & Air Connections
UNIT OPERATION:
1. Handpieces (sold separately) - Connect
the proper highspeed and lowspeed
handpieces to their appropriate connector.
Switch the handpiece selector toggle to
the desired handpiece. Depress foot
control for operation.
2. 3-Way Air/Water Syringe - Depress the
right button for air operation, and the left
button for water operation. Depressing
both buttons will create a mist. The syringe
features quick-change autoclavable tips:
To remove a tip, press on the locking ring
surrounding the tip socket and pull the
used tip straight out of the socket (Fig. 4).
To insert a new tip, press locking ring and
push tip into socket as far as it will go.
Release ring and gently tug on tip before
using to ensure that tip is securely locked
into socket.
Syringe Tip Sterilization:
1) Remove contaminated syringe tip.
2) Remove all visible signs of
contamination before autoclaving.
3) Autoclave tip at 132° C (270° F) for ten
minutes.
4) Sterilize between each patient use.
NOTE: Since only the tips can be
autoclaved, it is recommended that the
air/water syringe be bagged with a
disposable, single-use plastic sleeve
between each patient use.
OPERATION FUNCTIONS:
(See Figure 3)
1. Handpiece Selector - Selects highspeed
(HP1) or lowspeed (HP2) handpiece
operation.
4. Pressure Guage - Provides visual
indication of drive air pressure for the
handpiece in use.
5. Drive Air Pressure Control - Adjusts
drive air pressure to the highspeed and
lowspeed handpieces.
7. Air/Water Syringe - Delivers air, water, or
a combination mist. Supplied with
autoclavable tips.
3. Water Flow Control - Adjusts water
coolant flow to the highspeed handpiece.
2. Water On/Off Toggle - Controls on/off
flow of water coolant to the highspeed
handpiece.
6. Foot Control (not shown) - Controls drive
air pressure to the active handpiece. Apply
light foot pressure to any part of the foot
control cover.
PRESSURE
GUAGE
HANDPIECE
SELECTOR
WATER
ON/OFF
TOGGLE
WATER
FLOW
CONTROL
DRIVE AIR
PRESSURE CONTROL
(Underneath Console)
AIR/WATER
SYRINGE
Figure 3 - Console
Figure 4 - Tip Removal & Installation
DEPRESS
LOCKING RING
P/N: 420423
Rev. E
ECO: 15499
04/2022
PRINTED IN THE U.S.A.
P.O. Box 1548 Woodinville, WA 98072
8333 216th Street SE Woodinville, WA 98072
(425) 487-3157 (800) 426-5913
www.aseptico.com • [email protected]
Aseptico Inc. warrants its new products against defects in material and workmanship under normal and
proper use, care, and maintenance for a period of two (2) years from date of original invoice. This two (2)
year warranty does NOT apply nor is it extended to products that are not manufactured by Aseptico. These
products may be covered by a separate limited warranty provided by the particular manufacturer, and all
claims and questions regarding the same are to be directed to the particular manufacturer.
Expendable components, such as batteries, fuses, light bulbs, and tubing sets installed on Aseptico
products are specifically excluded and have no warranty. Consumable goods are warranted for the stated
expiration date of such goods.
Repair or replacement of any product(s) or part(s) under this warranty does not extend the term of this
warranty, and such product(s) or part(s) shall remain covered by the unexpired portion of the warranty
period, or for ninety (90) days from the date of return to Aseptico, whichever is later. This limited warranty
applies only to the initial or first installation of the product or part.
During the specific warranty periods set forth above, Aseptico will, at its option, repair or replace the
product(s) or particular part(s) that are found to be defective in either material or workmanship in part or
whole. Aseptico shall be the sole arbiter of such action. In the event of alleged defect under warranty, the
purchaser is to notify Aseptico’s Customer Service department promptly. Customer Service will provide
Return Material Authorization (RMA) instructions, usually directing that the product be returned for service,
shipping prepaid by the buyer or end user, to Aseptico or its designated and authorized warranty service
center.
This warranty shall not apply to products (1) that have been subjected to neglect, abuse, misuse, improper
installation, inadequate maintenance, or damage due to improper use of cleaning materials or chemicals,
or non-compliance with Aseptico’s storage, installation, operation, maintenance or environmental
requirements; (2) that have undergone any modification or repair not previously authorized by Aseptico in
writing, or service, repair or modification by or from any facility other than an authorized Aseptico service
center or technician, or that use non-authorized software or spare or replacement parts; or (3) that fail due
to reasonable and normal use or wear and tear, or materials made, furnished or specified by the buyer or
end user.
Aseptico does not assume under this warranty any risks or liabilities arising from the clinical use of its
products, whether or not such use involves coincidental utilization of products manufactured by others.
Under no circumstances will Aseptico be liable or responsible for special, compensatory, incidental,
consequential or punitive damages, lost profits, lost sales, or loss of use or loss of business opportunity by
or through the use of the product. Aseptico’s sole and maximum liability with respect to the product, other
than its obligations set forth above, shall be the total purchase price paid for the product.
WARRANTY:.