manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Assa Abloy
  6. •
  7. Door Opening System
  8. •
  9. Assa Abloy SARGENT 8800 Series Instruction Manual

Assa Abloy SARGENT 8800 Series Instruction Manual

This manual suits for next models

3

Other Assa Abloy Door Opening System manuals

Assa Abloy Norton PR1601 User manual

Assa Abloy

Assa Abloy Norton PR1601 User manual

Assa Abloy Corbin Russwin PED4600 A Series User manual

Assa Abloy

Assa Abloy Corbin Russwin PED4600 A Series User manual

Assa Abloy Besam SL500 User manual

Assa Abloy

Assa Abloy Besam SL500 User manual

Assa Abloy Norton 6011 Series User manual

Assa Abloy

Assa Abloy Norton 6011 Series User manual

Assa Abloy Norton 6300 Series Quick guide

Assa Abloy

Assa Abloy Norton 6300 Series Quick guide

Assa Abloy Corbin Russwin PED5600 Series User manual

Assa Abloy

Assa Abloy Corbin Russwin PED5600 Series User manual

Assa Abloy G-CO-C User manual

Assa Abloy

Assa Abloy G-CO-C User manual

Assa Abloy Norton 6300 Series User manual

Assa Abloy

Assa Abloy Norton 6300 Series User manual

Assa Abloy Norton PR7500 User manual

Assa Abloy

Assa Abloy Norton PR7500 User manual

Assa Abloy Corbin Russwin DC8200 Series User manual

Assa Abloy

Assa Abloy Corbin Russwin DC8200 Series User manual

Assa Abloy Corbin Russwin PED5800 Series User manual

Assa Abloy

Assa Abloy Corbin Russwin PED5800 Series User manual

Assa Abloy NORTON RIXSON 1600 Series User manual

Assa Abloy

Assa Abloy NORTON RIXSON 1600 Series User manual

Assa Abloy Yale YM Series User manual

Assa Abloy

Assa Abloy Yale YM Series User manual

Assa Abloy Corbin Russwin DC3210 Series User manual

Assa Abloy

Assa Abloy Corbin Russwin DC3210 Series User manual

Assa Abloy SW200 User manual

Assa Abloy

Assa Abloy SW200 User manual

Assa Abloy Lockwood L7714SDSIL User manual

Assa Abloy

Assa Abloy Lockwood L7714SDSIL User manual

Assa Abloy Norton 7570 Series User manual

Assa Abloy

Assa Abloy Norton 7570 Series User manual

Assa Abloy h.e.s. 9100 Series Manual

Assa Abloy

Assa Abloy h.e.s. 9100 Series Manual

Assa Abloy SARGENT 1431 Series User manual

Assa Abloy

Assa Abloy SARGENT 1431 Series User manual

Assa Abloy Sargent FIREGUARD 2408 Series User manual

Assa Abloy

Assa Abloy Sargent FIREGUARD 2408 Series User manual

Assa Abloy Adams Rite EX89 Operating instructions

Assa Abloy

Assa Abloy Adams Rite EX89 Operating instructions

Assa Abloy Norton 6300 Series User manual

Assa Abloy

Assa Abloy Norton 6300 Series User manual

Assa Abloy Besam SW200i User manual

Assa Abloy

Assa Abloy Besam SW200i User manual

Assa Abloy Norton SafeZone 7100SZ Series Quick guide

Assa Abloy

Assa Abloy Norton SafeZone 7100SZ Series Quick guide

Popular Door Opening System manuals by other brands

Pamex KT-INP35 Installation instruction

Pamex

Pamex KT-INP35 Installation instruction

Cal-Royal N-F77CVR Installation instruction

Cal-Royal

Cal-Royal N-F77CVR Installation instruction

Scrigno OPEN1000 Assembly manual

Scrigno

Scrigno OPEN1000 Assembly manual

TriMark UM 34 instructions

TriMark

TriMark UM 34 instructions

BFT WIND RMB 130B 200 installation manual

BFT

BFT WIND RMB 130B 200 installation manual

Alecto ADI-250 user manual

Alecto

Alecto ADI-250 user manual

Besam Swingmaster MP Installation, adjustment and maintenance instructions

Besam

Besam Swingmaster MP Installation, adjustment and maintenance instructions

CRL SENIOR PRIMA manual

CRL

CRL SENIOR PRIMA manual

GAL MOVFR Quick setup

GAL

GAL MOVFR Quick setup

Normstahl IDO7 installation manual

Normstahl

Normstahl IDO7 installation manual

Häfele Finetta T 70 VF manual

Häfele

Häfele Finetta T 70 VF manual

AGS D-PL Instructions for fitting, operating and maintenance

AGS

AGS D-PL Instructions for fitting, operating and maintenance

Stanley MA900ñ Installation and owner's manual

Stanley

Stanley MA900ñ Installation and owner's manual

WITTUR Hydra Plus UD300 Instruction handbook

WITTUR

WITTUR Hydra Plus UD300 Instruction handbook

Alutech TR-3019-230E-ICU Assembly and operation manual

Alutech

Alutech TR-3019-230E-ICU Assembly and operation manual

MPC ATD ACTUATOR 50 ATD-313186 Operating and OPERATING AND INSTALLATION Manual

MPC

MPC ATD ACTUATOR 50 ATD-313186 Operating and OPERATING AND INSTALLATION Manual

GEZE ECturn user manual

GEZE

GEZE ECturn user manual

Chamberlain T user guide

Chamberlain

Chamberlain T user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

649 Strike
Center chassis
assembly (8828)
Cover
(8828, 8863)
Center chassis
assembly (8863)
649 Strike (for non-Fire Rated
application) – attach with
(2) strike screws and two
lock washers
Rim cylinder
Center chassis
assembly
(8866)
Cover
(8866)
Mark vertical and horizontal
reference lines on the door
Horizontal
reference line
(C of chassis and
rail assembly)
L
Horizontal
reference line
(C of mounting
holes)
L
Vertical
reference line
(C of chassis)
L
Finished floor
Identify type of installation to
determine location of vertical C
L
Single Door (Non-Fire Rated)
Door
Vertical reference line
(C of chassis)
L
For 649 strike Dim. “A” = 2-1/4"
For 613 strike Dim. “A” = 1-3/4"
For 642 strike Dim. “A” = 1-1/2"
Double Door with 980 Mullion
Door Door
Vertical reference
line (C of chassis)
L
Single Door (12- Fire Rated Exit Device)
Double Door with 12-980 Mullion
Vertical reference
line (C of chassis)
L
Vertical reference
line (C of chassis)
L
Apply Rail Assembly
Prepare Door
Tape template on inside of door
along reference lines.
Spot and drill holes.
Vertical reference line
(C of chassis)
L
Horizontal reference line
(37-5/8" from finished floor
for 41" height center of
push rail)
1. Attach chassis to
door with (4) #10
mounting screws.
2. Through-bolt outside
trim and cylinder
to chassis, if used.
Mount SARGENT cylinder
with (2) screws thru chassis
Chassis
mounting
screw
Cylinder
mounting
screw
STS
trim
Countersunk
washer
A6703G 3/12
CAUTION!
Before Starting:
– Install mullion if used;
– Door should be fitted and hung;
– Check box label for size of exit device.
Available Stock Lengths:
Length “E”: 32" door, no cut off required.
Can be cut to fit doors down to 24" wide.
Length “F”: 36" door, no cut off required.
Can be cut to fit doors down to 33" wide.
Length “J”: 42" door, no cut off required.
Can be cut to fit doors down to 37" wide.
Length “G”: 48" door, no cut off required.
Can be cut to fit doors down to 43" wide.
For Assistance, contact SARGENT at 800-727-5477 or www.sargentlock.com
IMPORTANT:
Surface of the door where exit device
is applied must be flush.
Clear away any raised projections
to allow exit device to rest on
flat surface of the door.
US Patent No. 268003
Canadian Patent No. RD1981
End
cap
Mounting
plate
“Lock Down Key”
To operate:
Depress pushrail; insert
hex key and turn clockwise.
ATTENTION:
Not furnished with
12- (Fire Rated) exit devices
Rail assembly
• Check box label for rail size and refer to chart
for door sizes. If cutting is not required,
proceed to step “B”.
• If cutting is required, continue
with step “A”.
Determine cut off dimension “X” by
subtracting 1-3/4" from dimension “Y”.
Mark cut off point on mounting rail.
For doors with stile
rail must overlap stile
by 1/2" min.
Vertical reference line
(C of chassis)
L
1-3/4" Min.
Mortise
cylinder
Collar
Cut off on mark
and deburr
Depress arm into rail opening and slide
rail onto chassis.
Level rail and fasten mounting plate.
Level
Mounting plate
Arm
Attach rail assembly to the
chassis with two #8 truss
head machine screws
Place mounting plate tight
against rail and attach it
to the door with three
#10 round head screws
Attach cover to chassis with
four (4) cover screws
Attach end cap to
mounting plate with
two cover screws
649 Strike (for Fire Rated
application) – attach with (2)
outer screws and adjust for
proper position. Drill and tap
thru strike two holes in frame
and fasten strike in place with
(2) inner screws.
Door
Door Door
649 Strike
649 Strike
649 Strike
Apply Hardware
Apply Covers and Strike
INSTRUCTIONS FOR INSTALLING SARGENT®8800 AND 12-8800
SERIES RIM EXIT DEVICES FOR 28, 63 AND 66 FUNCTIONS
Copyright ©2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction
in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Mark vertical and horizontal
reference lines on the door
Identify type of installation to
determine location or vertical C
L
Horizontal
reference line
(C of chassis and
rail assembly)
L
Horizontal
reference line
(C of mounting
holes)
L
Vertical
reference line
(C of chassis)
L
Prepare Door
Tape template on inside of door
along reference lines.
Spot and drill holes.
Vertical
reference line
(C of chassis)
L
Horizontal reference line
(37-5/8" from finished floor
for 41" height center of
push rail.)
Vertical reference
line (C of chassis)
L
Vertical reference
line (C of chassis)
L
Single Door (Non-Fire Rated)
Double Door with 980 Mullion
Single Door (12- Fire Rated Exit Device)
Double Door with 12-980 Mullion
For 649 strike Dim. “A” = 2-1/4"
For 613 strike Dim. “A” = 1-3/4"
For 642 strike Dim. “A” = 1-1/2"
Door Door
Vertical reference
line (C of chassis)
L
Door
Door Door
649 Strike
649 Strike
649 Strike
Apply Hardware
1. Attach chassis to
door with (4) #10
mounting screws.
2. Through-bolt outside
trim and cylinder
to chassis, if used.
Mount SARGENT cylinder
with (2) screws thru chassis
Chassis
mounting
screw
Cylinder
mounting
screw
Apply Covers and Strike
Attach cover to chassis with
four (4) cover screws
Attach end cap to
mounting plate with
two cover screws
649 Strike (for Fire Rated
application) – attach with (2)
outer screws and adjust for
proper position. Drill and tap
thru strike two holes in frame
and fasten strike in place with
(2) inner screws
Apply Rail Assembly
Determine cut off dimension “X” by
subtracting 1-3/4" from dimension “Y”.
Mark cut off point on mounting rail.
For doors with stile
rail must overlap stile
by 1/2" min.
Vertical reference line
(C of chassis)
L
1-3/4" Min.
Cut off on mark
and deburr
Depress arm into rail opening and slide
rail onto chassis.
Level rail and fasten mounting plate.
Arm
Level
Mounting plate
Attach rail assembly to the
chassis with two #8 truss
head machine screws
Place mounting plate tight
against rail and attach it
to the door with three #10
round head screws
• Check box label for rail size and refer
to chart for door sizes. If cutting is not
required, proceed to step “B”.
• If cutting is required, continue
with step “A”.
CAUTION!
Before Starting:
– Install mullion if used;
– Door should be fitted and hung;
– Check box label for size of exit device.
Available Stock Lengths:
Length “E”: 32" door, no cut off required.
Can be cut to fit doors down to 24" wide.
Length “F”: 36" door, no cut off required.
Can be cut to fit doors down to 33" wide.
Length “J”: 42" door, no cut off required.
Can be cut to fit doors down to 37" wide.
Length “G”: 48" door, no cut off required.
Can be cut to fit doors down to 43" wide.
For Assistance, contact SARGENT at 800-727-5477 or www.sargentlock.com
IMPORTANT:
Surface of the door where exit device
is applied must be flush.
Clear away any raised projections
to allow exit device to rest on
flat surface of the door.
US Patent No. 268003
Canadian Patent No. RD1981
Rim cylinder
649 Strike
shown
Center chassis
assembly
Cover Collar
Mortise
cylinder
Rail assembly
“Lock Down Key”
To operate: Depress pushrail;
insert hex key and turn clockwise.
Mounting
bracket
End
cap
Finished Floor
Vertical reference line
(C of chassis)
L
A6703G 3/12
649 Strike (for non-Fire Rated
application) – attach with
(2) strike screws and two
lock washers
INSTRUCTIONS FOR INSTALLING SARGENT®
8816 AND 12-8816 SERIES RIM EXIT DEVICES
Copyright ©2008, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction
in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.