manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CAMDEN
  6. •
  7. Keypad
  8. •
  9. CAMDEN CV-634PR User manual

CAMDEN CV-634PR User manual

Model CV-634PR
Everswitch Proximity Reader Plus Keypad
Installation Instructions
OPERATION MODES:
Output formats: 26 bit Wiegand with programmable
site code
Power Supply: 5 to 12 VDC
Power Consumption: Max 150 mA
Transmitter/Receiver frequency: 125Khz
Mounting: Universal (single gang box)
Environment: IP68 ; 100% relative humidity
Operating Temperature: - 20 to + 70ºC
Dimensions: 120 x 90 x 20mm (4.72” x 3.54” x .79”)
Anti-tamper Optical protection
Certifications: Complies with FCC Part 15
Model CV-634PR is equipped with 2 electronically
interlocked devices - the Proximity Reader and the
Piezoelectric Keypad.
It supports the following operation modes:
1. Prox + Pin. Present Prox card. The unit will read the
content and send it over the Data wires to the host.
Enter PIN code. The unit will send each digit over the
same Data wires to the host. The Keypad and the Prox
reader are interlocked so that when one is functioning
the other is inhibited until the data is transmitted.
2. Prox Only. The prox electronics is independently
communicating via Data wires.
3. Keypad Only. The keypad electronics is independently
communicating via Data wires..
Verification
Apply power to the unit. During the rst 5 seconds it is
possible to reprogram the Site code (see instructions on next
page). The unit will activate the buzzer and the Yellow LED 3
times. At the same time the RED or the Green LED will come
ON depending on the Central Computer setup.
Present a valid HID encrypted card at 5 cm (2”) distance
maximum. The unit will activate the Buzzer and the Yellow
Led once.
Enter any combination of PIN code up to 65534. The
unit will activate the Buzzer and the Yellow Led with each
pressed key.
COLOR FUNCTION ELECTRICAL FUNCTION
RED Input Voltage 5 to 12 VDC
BLACK Ground
GREEN Data 0 Open collector 1Kohm pull-up to internal +5V
WHITE Data 1 Open collector 1Kohm pull-up to internal +5V
BROWN LED Input No Voltage
BLUE CCTV output Open collector 0,250 A activated with each
key for 30 sec
VIOLET Housing Ground
ORANGE Buffered Input
GREY Tamper Output Open collector 0,100 A “Low” when light sensed
Wiring
Model CV-634PR Piezo Proximity Reader Manual
Page 2 of 2
Push Buttons Keypads Strikes Magnetic Locks Key Switches Relays & Timers Access Control
5502 Timberlea Blvd.,
Mississauga, ON Canada
L4W 2T7
www.camdencontrols.com
Toll Free: 1.877.226.3369
File: CV-634PR Instructions..indd- Rev1
Revised: July 4th, 2014
Part No: 40-82B042
The following WIEGAND output is sent each time the # (enter)
key is pressed.
P S S S S S S S S N N N N N N N N N N N N N P
BIT 1 2 9 10 25 26
BIT 1 is an even parity for the following 12 bits.
The sum of bits 1-13 is even.
BITS 2-9 are the programmable SITE CODE. While
pressing * during the rst 3 seconds on power up
it is possible to program the site code. Any number
from 000 to 255 is possible.
BITS 10-25 this is the number entered prior to pressing
# (enter). Leading 0’s are added as required.
Bit 10 is most signicant.
BIT 26 Odd parity over previous 12 bits. The sum of bits
14-26 is odd.
EXAMPLE: A card code of 123 entered:
1 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 1 1 1
(site code 004)
The data is sent at 2 msec per bit with a pulse duration
of 70 μsec
A buzzer beeps with each key press.
Note: Camden Piezo Proximity readers plus Keypad are
programmed with default Site Code “000”. The maximum
Site Code is 255.
Example to set site code to 100. Disconnect the power
supply for a minimum of 10 seconds. Connect the power
supply, and the unit will start beeping. During the rst 5
seconds perform the following:
Enter * The keypad enters programming mode,
the red LED flashes.
Enter 100 # The site code of 100 is assigned.
26 BIT WIEGAND SPECIFICATIONS:
1. Blue Wire - PRESSING any key on the keypad will generate
a 30 second 0.25 amp intermittent duty grounding output.
2. Orange Wire - When the Hold Line, Orange wire, is pulled
“low”, any codes entered on the keypad are stored in the
buffer. When the Hold Line is released to logic “high” – the
buffered code data is sent.
2. Grey Wire - When the photodiode senses ambient light
the Grey wire is pulled “LOW”
An error code is generated by any of the following:
a) Pressing the # key with no preceding digits;
b) Pressing any number of only zero’s prior to
pressing the # key, or;
c) Pressing 65,535 or any number above 65,535.
An Error Code will send all binary 1’s to your panel.
DO NOT Program your panel to accept code number 65,535.

Other CAMDEN Keypad manuals

CAMDEN CV-940-20 Series User manual

CAMDEN

CAMDEN CV-940-20 Series User manual

CAMDEN CM-110SK User manual

CAMDEN

CAMDEN CM-110SK User manual

CAMDEN CV-940 Series User manual

CAMDEN

CAMDEN CV-940 Series User manual

CAMDEN CM-120TX User manual

CAMDEN

CAMDEN CM-120TX User manual

CAMDEN CM-550SK V3 User manual

CAMDEN

CAMDEN CM-550SK V3 User manual

CAMDEN inVISION CV-500PPK-V.2 User manual

CAMDEN

CAMDEN inVISION CV-500PPK-V.2 User manual

CAMDEN 626SW User manual

CAMDEN

CAMDEN 626SW User manual

CAMDEN CM-500SK User manual

CAMDEN

CAMDEN CM-500SK User manual

CAMDEN CV-6268W User manual

CAMDEN

CAMDEN CV-6268W User manual

CAMDEN CM-626S Series User manual

CAMDEN

CAMDEN CM-626S Series User manual

CAMDEN Invision CV-920 Series User manual

CAMDEN

CAMDEN Invision CV-920 Series User manual

CAMDEN CV-550SPK V3 User manual

CAMDEN

CAMDEN CV-550SPK V3 User manual

CAMDEN CV-634W User manual

CAMDEN

CAMDEN CV-634W User manual

CAMDEN CM-120wV2 User manual

CAMDEN

CAMDEN CM-120wV2 User manual

CAMDEN CV-626 User manual

CAMDEN

CAMDEN CV-626 User manual

CAMDEN 634W User manual

CAMDEN

CAMDEN 634W User manual

Popular Keypad manuals by other brands

Anviz A Series user guide

Anviz

Anviz A Series user guide

rako WCM-060 instruction manual

rako

rako WCM-060 instruction manual

Hama SK 210 Operating	 instruction

Hama

Hama SK 210 Operating instruction

B&D tri-tran 062269 installation instructions

B&D

B&D tri-tran 062269 installation instructions

Bosch D1255/D1255B Installation insructions

Bosch

Bosch D1255/D1255B Installation insructions

iPort xPRESS quick start guide

iPort

iPort xPRESS quick start guide

Russound KPSC quick start guide

Russound

Russound KPSC quick start guide

AMX ProLink PRO-DP8 instruction manual

AMX

AMX ProLink PRO-DP8 instruction manual

Maximum Controls MAX Quick installation guide

Maximum Controls

Maximum Controls MAX Quick installation guide

CDVI DGA installation manual

CDVI

CDVI DGA installation manual

YASKAWA JVOP-KPLCC04A Series installation manual

YASKAWA

YASKAWA JVOP-KPLCC04A Series installation manual

Bosch D1265 quick guide

Bosch

Bosch D1265 quick guide

ADEMCO 6128RF installation instructions

ADEMCO

ADEMCO 6128RF installation instructions

Bosch D621 Series Specifications

Bosch

Bosch D621 Series Specifications

URC TKP-2000 owner's manual

URC

URC TKP-2000 owner's manual

Visonic KP-140 PG2 user guide

Visonic

Visonic KP-140 PG2 user guide

Tyco Visonic  KP-241 quick start guide

Tyco

Tyco Visonic KP-241 quick start guide

SECO-LARM SLI ENFORCER SK-B111-PQ Additional information

SECO-LARM

SECO-LARM SLI ENFORCER SK-B111-PQ Additional information

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.