9
VIVO-D102(M)
Quick installation and programming guide English
IMPORTANT
NOTE
This quick guide is a summary of the complete installation manual. The manual contains safety warnings
and other explanations which must be taken into account. The installation manual can be downloaded by
going to the "Downloads" section at the Erreka website:
http://www.erreka.com/Automatismos/descargaDocumentos.aspx
G
E114A
ELECTRICAL CABLING:
Element Nº threads x section Maximum length
A: Main power supply 3x1.5mm230m
B: Flashing light / Traffic light 2x0.5mm2/ 3x0.5mm220m
C: Photocells (Tx / Rx) 2x0.5mm2/ 4x0.5mm230m
D: Pushbutton/wall key 2x0.5mm250m
E: Operator (motor + encoder) Duct (2x1mm2 + interior screened duct
2x0.5mm2)
8m (maximum 25m with
cable 2x2.5mm2)
F: Operator release 2x0.5mm225m
G: Antenna Coaxial cable 50k(RG-58/U) 5m
Elements of the complete installation
10
D102: 230Vac/ 50Hz
D102M: 125Vac/ 60Hz
MOTOR
ENCODER
STOP
M
MOTOR
ENCODER
P14
P15
P13
G1
G2
M
GND
SNG1
V+
CHG
BAT: (2x12V/1,2 Ah)
BATTERY
IN/OUT
ADO01
General connections
STOP CABLE CONNECTOR:
connect to the release switch
(in the models with encoder
and release). In the models
without release, make an
electrical bridge.
G1 Blue (motor)
G2 Red (motor)
P14 (GND) Mesh (encoder mesh) (–)
P15 (SNG1) Green (encoder signal) (S)
P13 (V+) Brown (encoder power supply) (+)
M114C
D1 and D2:
CL (static) Door closed
CL (flashing) Door closing
OP (static) Door open
OP (flashing) Door opening
XX (countdown) Door on standby
StOP Operator unlocked
PA (static) Pause (operation not complete)
rS (static)
Door searching for close position
D3 and D4:
C5 Closing safety device activated
E1 Encoder motor shudown
F1 Thrust limit exceeded
bA Battery working
Ftço Photocells defective (pre-testing)
Display indications
11
Turning direction change and check (C1)
This operation is only necessary if the operator opens the gate instead of closing it when making a reset (rS).
Radio code programming, P1 (only with RSD receiver)
If a receiver other
than RSD is used, see
the corresponding
instructions.
Open/close programming (P3)
The lower closing stopper must be installed before programming the run (see the
operator manual).
OWait whilst the door carries
out the open/close.
If you want the door to stop
before reaching the upper
stopper, press the transmitter
button at the required point.
12
Complete programming chart
D1 D2 Parameter D3 D4
Pre-
determined
option
Options or values
C1Motor turning direction 01x
02
4Disabled
5Closing safety device (photocell or strip) 00xDevice not installed
10 Device without testing
11 Device with testing
P1Total opening radio code programming oç
2Disabled
3Door open/close programming oç
F1Functioning mode 01 Automatic
02xStep-by-step
2Standby in automatic mode 0...5. 0...9 15 59 = 59 sec; 2.5 = 2 min. 50 sec., etc
3Disabled
A0Flashing light 01xNo pre-warning
02 With pre-warning
1Garage light time 0...5. 0...9 03 59 = 59 sec; 2.5 = 2 min. 50 sec., etc
2Door speed 0 1...5 03 01: minimum speed;
05: maximum speed
3Slowdown speed 0 1...5 03 01: minimum speed;
05: maximum speed
4Slowdown distance 0 0...5 00 00: minimum distance;
05: maximum distance
5Disabled
6Maximum thrust
maximum thrust in opening 1...9 X 6X 1X: minimum thrust (in opening);
9X: maximum thrust (in opening)
maximum thrust in closing X 1...9 X6 X1: minimum thrust (in closing);
X9: maximum thrust (in closing)
7Closing photocell used during standby (in
automatic mode only)
01 Immediate close
02xRestart standby time
03 Has no effect
8Pushbutton operation during standby (in
automatic mode only)
01 Immediate close
02xRestart standby time
03 Has no effect
9Opening mode 01xOpening in accordance with the mode
selected in the main functions (F)
02 Collective opening (the control board
does not obey the key commands during
opening)
03 Step-by-step opening (the door halts if a
key device is activated during opening.
The door closes when operated again)
ç1Operations carried out XX Indicates the cycles completed,
multiplying the indicated figure by an
amount, for example:
68 indicates 6,800 cycles completed
6.8 indicates 68,000 cycles completed

Other manuals for VIVO-D102

1

This manual suits for next models

1

Other Erreka Gate Opener manuals

Erreka MAGIC Operating instructions

Erreka

Erreka MAGIC Operating instructions

Erreka SIRIUS Operating instructions

Erreka

Erreka SIRIUS Operating instructions

Erreka CICLON Operating instructions

Erreka

Erreka CICLON Operating instructions

Erreka TORO KM1800 Operating instructions

Erreka

Erreka TORO KM1800 Operating instructions

Erreka Puma User guide

Erreka

Erreka Puma User guide

Erreka BUL BL33 Operating instructions

Erreka

Erreka BUL BL33 Operating instructions

Erreka ARES Series User guide

Erreka

Erreka ARES Series User guide

Erreka DINGO Operating instructions

Erreka

Erreka DINGO Operating instructions

Erreka PUMA-I Operating instructions

Erreka

Erreka PUMA-I Operating instructions

Erreka DINGO Operating instructions

Erreka

Erreka DINGO Operating instructions

Erreka IZAR User guide

Erreka

Erreka IZAR User guide

Erreka ARC Series User guide

Erreka

Erreka ARC Series User guide

Erreka VULCAN D User manual

Erreka

Erreka VULCAN D User manual

Erreka TOPO User guide

Erreka

Erreka TOPO User guide

Erreka Dolfin Operating instructions

Erreka

Erreka Dolfin Operating instructions

Erreka MAGIC User guide

Erreka

Erreka MAGIC User guide

Erreka HERA Technical document

Erreka

Erreka HERA Technical document

Erreka CICLON Series Operating instructions

Erreka

Erreka CICLON Series Operating instructions

Erreka TORO KM1800 Operating instructions

Erreka

Erreka TORO KM1800 Operating instructions

Erreka MAGIC User guide

Erreka

Erreka MAGIC User guide

Erreka VIVO-M101 Operating instructions

Erreka

Erreka VIVO-M101 Operating instructions

Erreka VULCAN User guide

Erreka

Erreka VULCAN User guide

Erreka JEDI JES100E User manual

Erreka

Erreka JEDI JES100E User manual

Erreka V2 CICLON User manual

Erreka

Erreka V2 CICLON User manual

Popular Gate Opener manuals by other brands

Nice Apollo 73001K manual

Nice Apollo

Nice Apollo 73001K manual

Platinum Access Systems BARRIER Installation instructions manual

Platinum Access Systems

Platinum Access Systems BARRIER Installation instructions manual

Chamberlain CSL24UL installation manual

Chamberlain

Chamberlain CSL24UL installation manual

Nice TTN3724HS Instructions and warnings for installation and use

Nice

Nice TTN3724HS Instructions and warnings for installation and use

Genius RAINBOW 324 C GUIDE FOR THE INSTALLER

Genius

Genius RAINBOW 324 C GUIDE FOR THE INSTALLER

BFT P7 Installation and user manual

BFT

BFT P7 Installation and user manual

DITEC IP1730 Installation handbook

DITEC

DITEC IP1730 Installation handbook

Casanoov TANKER C600 instruction manual

Casanoov

Casanoov TANKER C600 instruction manual

CAME ATS-P324 Quick setup guide

CAME

CAME ATS-P324 Quick setup guide

King gates INTROSMALL24/400 Installation and use instructions and warnings

King gates

King gates INTROSMALL24/400 Installation and use instructions and warnings

SOMFY IXENGO J S 230V installation instructions

SOMFY

SOMFY IXENGO J S 230V installation instructions

SOMFY SGS 201 Operating and installation guide

SOMFY

SOMFY SGS 201 Operating and installation guide

Beninca BILL 50 Series User handbook

Beninca

Beninca BILL 50 Series User handbook

GATEXPERT GT800ACL user manual

GATEXPERT

GATEXPERT GT800ACL user manual

TMT Automation BOXER500E user manual

TMT Automation

TMT Automation BOXER500E user manual

Daspi DS 301 manual

Daspi

Daspi DS 301 manual

SOMFY ELIXO 500 io installation manual

SOMFY

SOMFY ELIXO 500 io installation manual

Chamberlain 8747EML quick start guide

Chamberlain

Chamberlain 8747EML quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.