Page 1
Installation Guide |
EG97023 Series Layer 3 Hardened Managed Ethernet Switch
08/30/2022
Copyright 2022 EtherWAN Systems, Inc. All Rights Reserved
Unpacking
Open the carton and unpack the items. Your package should include:
▪EG97023 Ethernet switch with RJ-45/SFP/USB dust covers installed
▪2 Mounting brackets
▪12 Mounting screws
▪1 RJ-45 Console cable
▪1 AC Power Cord (optional)
▪Quick install guide
What Else You Need
▪Shielded twisted pair cables and corresponding shielded RJ45 connectors
▪Appropriate SFP cable and SFP modules for SFP ports
Select a Location
Equipment is intended for
installation in Restricted
Access Location
Les matériels sont destinés à être installés
dans des EMPLACEMENTS À ACCÈS
RESTREINT
▪Installation: Rack mount. Use the enclosed brackets and screws to mount the
switch in an open or enclosed 19” rack.
▪Select a power source within 6 feet (1.8 meters).
▪Choose a dry area with ambient temperature between -40 and 75°C (Models
EG97023-2VX (X = WR, CR, WR-CC or CR-CC), (CR and CR-CC use in US/CSA
only)); -40 and 65 °C for (Models EG97023-2VX (X = CR or CR-CC)).
▪Keep away from heat sources, sunlight, warm air exhausts, hot-air vents, and
heaters.
▪Be sure there is adequate airflow.
Caution
Shock hazard
Disconnect all power
sources
Mise en garde
Risque d'électrocution
Débranchez toutes les sources
d'alimentation
Connect to the Data Ports
The EG97023 has the following ports:
▪8 x 100/1000 BASE dual rate SFP ports
▪12 x 1/10G dual rate SFP+ ports
▪1 x RJ-45 management port with dust cover
▪1 x RJ-45 console port with dust cover
▪1 x USB console port
▪1 x USB backup/load configuration port
Use category 5e or higher UTP/STP cable for TX ports. For SFP and SFP+ ports,
ensure that the same type of transceiver is used at both ends of the link and that
the correct type of fiber cable is used.
Connect Power
Caution
Shock hazard
Connect to earth before
connecting to supply
Mise en garde
Risque d'électrocution
Connectez àla terre avant de
connecter àl'alimentation
Power Input Interfaces
VWR, VWR-CC –100-240VAC / 100-250VDC Redundant (Terminal Block)
VCR, VCR-CC –100-240VAC Redundant (AC Inlet)
If your EG97023 comes with AC power cables, connect the cables into the power
modules at the back of the switch. If your switch comes with an AC terminal block
(no cable), then connect the switch to a suitable power supply using 10 to 18
AWG wire. Redundant power supply is supported. However, only one power
input is required to operate the switch. Input voltage is 100 –240 VAC.
Relay Output Alarm
The switch provides one dry contact for signaling of a user-defined power or port
failure. The alarm relay default is “open” and forms a closed circuit when the
event occurs. The relay output can be connected to an alarm signaling device.
Relay output current is 30VDC / 0.6A.
NOTE: The initial normal state of the relay is open, and if switch loses *all* power,
then this state will come into effect. This is important to remember when using
the relay to indicate a power failure. The relay will close in an alarm state when
there is redundant power input and an alarmed input fails.
Front Panel LEDs
LED Panel Layout
Power 1 & 2
Green Power on, Off No power
Link/Act
Green: Network connection established
Flashing: Port sending or receiving data
Red: Link down or power down
Reset Button: Press and hold for less than 10 seconds to reboot the switch. Press
and hold for more than 10 seconds to reset the switch to the default password.
Console Configuration
Connect to the switch using the enclosed Ethernet cable to connect a serial port
on a PC to the RJ-45 Management port located on the front panel next to the USB
port. The IP address of VLAN 1 is 192.168.1.10.
Configuration via CLI
If using a terminal-emulation program such as Putty, configuration settings are:
Baud rate: 115,200bps, Data bits: 8, Parity: none, Stop bit: 1, Flow control: none.
The default login name is “root,” no password.
Web Configuration
Log in to the switch by launching a web browser and entering 192.168.1.10 (or
192.168.2.10 via the RJ-45 management port) in the address bar. Enter the
default login ID: root (no password) and click “Login.”
USB Port
The switch is equipped with one USB port (Type A connector) for configuration
file and syslog backup. The USB port can be used to save the configuration and
Syslog to a (FAT32) USB storage device.
Plug the device into the USB port, and use the “Save Configuration” command in
the web interface, or “copy running-config startupconfig” in the CLI. Use the
“Export Logs to USB” command in the web interface, or “export logs” in the CLI.
Other Information
The power cord must be connected to a properly earth grounded outlet.
Rack Mount Instructions - The following or similar rack-mount instructions are
included with the installation instructions:
A
Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment
may be greater than room ambient. Therefore, consideration should be
given to installing the equipment in an environment compatible with the
maximum ambient temperature (Tma) specified by the manufacturer.
B
Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment
is not compromised.
C
Mechanical Loading - Mounting of the equipment in the rack should be
such that a hazardous condition is not achieved due to uneven
mechanical loading.
D
Circuit Overloading - Consideration should be given to the connection of
the equipment to the supply circuit and the effect that overloading of the
circuits might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be
used when addressing this concern.
E
Reliable Earthing - Reliable earthing of rack-mounted equipment should
be maintained. Particular attention should be given to supply connections
other than direct connections to the branch circuit (e.g. use of power
strips).
The socket-outlet shall be installed near the equipment and shall be easily
accessible.
▪Do not disable the power cord grounding plug. The grounding plug is an
important safety feature
▪Plug the power cord into a grounded (earthed) electrical outlet that is easily
accessible at all times.
▪The means of power cord of adapter should be connected to a socket-outlet
with earthing connection.
▪This equipment is intended to be used in a restricted access location and be
used by a qualified person.
▪This equipment is not suitable for use in locations where children are likely to
be present.
▪The power cord shall be IEC 60227 certified, rated 0.75 mm2 x 3C or UL
recognized minimum 18AWG
AC Inlet
Page 2
Installation Guide
Copyright 2022 EtherWAN Systems, Inc. All Rights Reserved
EG97023 Layer 3 Hardened Managed Ethernet Switch | W70G-EG97023Q1
All power connection wiring should be made by a qualified electrician in
accordance with National Electrical Code, ANSI/NFPA 70 and Canadian Electrical
Code, Part I, CSA C22.1. An IEC certified or UL listed single-phase type circuit-
breaker, rated maximum 20A, shall be installed between mains circuit and
equipment.
Thumbscrews should be tightened with a tool after both initial installation
subsequent access to the panel.
Note: This equipment must use UL recognized Laser Class 1 optical transceiver.
This equipment is intended to be used in a restricted access location and be used
by a qualified person.
This equipment is not suitable for use in locations where children are likely to be
present.
Caution
This product relies on the building's installation for short-circuit (overcurrent)
protection and power disconnection. Ensure that the protective device is rated
MAX 20 A, 250 V and shall be easily accessible.
The performance levels of the field wiring terminals provided for power supply
connection:
a. Range of wire sizes: 10 - 18 AWG
b. Conductor material: copper wire only
c. Tightening torque(s): 14 In.-Lb
Manufacturer information:
ETHERWAN SYSTEMS, INC.
33F, No. 93, Sec. 1, Xintai 5th Rd., Xizhi Dist., New Taipei City, 221 Taiwan
www.etherwan.com
If any items are missing or damaged, notify your EtherWAN representative.
If possible, save the carton and packing material in case you need to ship or
store the switch in the future. The full product manual can be downloaded
from:
www.etherwan.com

Other EtherWAN Switch manuals

EtherWAN EX17008 User manual

EtherWAN

EtherWAN EX17008 User manual

EtherWAN EX19164A User manual

EtherWAN

EtherWAN EX19164A User manual

EtherWAN EX26262F Series User manual

EtherWAN

EtherWAN EX26262F Series User manual

EtherWAN EX45900 series User manual

EtherWAN

EtherWAN EX45900 series User manual

EtherWAN EX27000 Series User manual

EtherWAN

EtherWAN EX27000 Series User manual

EtherWAN EX16926 User manual

EtherWAN

EtherWAN EX16926 User manual

EtherWAN EX41941 User manual

EtherWAN

EtherWAN EX41941 User manual

EtherWAN EX73000 Series User manual

EtherWAN

EtherWAN EX73000 Series User manual

EtherWAN EX34000 User manual

EtherWAN

EtherWAN EX34000 User manual

EtherWAN EX33000 Series User manual

EtherWAN

EtherWAN EX33000 Series User manual

EtherWAN EX19082 User manual

EtherWAN

EtherWAN EX19082 User manual

EtherWAN EX87000 Series User manual

EtherWAN

EtherWAN EX87000 Series User manual

EtherWAN EX26262F Series User manual

EtherWAN

EtherWAN EX26262F Series User manual

EtherWAN EX42395BT User manual

EtherWAN

EtherWAN EX42395BT User manual

EtherWAN EX41941F User manual

EtherWAN

EtherWAN EX41941F User manual

EtherWAN EX45000 Series User manual

EtherWAN

EtherWAN EX45000 Series User manual

EtherWAN EX17908 Series User manual

EtherWAN

EtherWAN EX17908 Series User manual

EtherWAN EX63000 Series | User manual

EtherWAN

EtherWAN EX63000 Series | User manual

EtherWAN EX78600 User manual

EtherWAN

EtherWAN EX78600 User manual

EtherWAN EX75000 User manual

EtherWAN

EtherWAN EX75000 User manual

EtherWAN EX32905 Series User manual

EtherWAN

EtherWAN EX32905 Series User manual

EtherWAN EX42914 Series User manual

EtherWAN

EtherWAN EX42914 Series User manual

EtherWAN EX61000A User manual

EtherWAN

EtherWAN EX61000A User manual

EtherWAN EX78000 Series User manual

EtherWAN

EtherWAN EX78000 Series User manual

Popular Switch manuals by other brands

Advantech EKI-2528i-m12 Startup manual

Advantech

Advantech EKI-2528i-m12 Startup manual

Gira 0144 30 operating instructions

Gira

Gira 0144 30 operating instructions

Inaxsys IN-162POEWM Web configuration guide

Inaxsys

Inaxsys IN-162POEWM Web configuration guide

AbleNet Blue2 quick start guide

AbleNet

AbleNet Blue2 quick start guide

Moeller LZMC Series installation instructions

Moeller

Moeller LZMC Series installation instructions

Enable-IT 8805 quick start guide

Enable-IT

Enable-IT 8805 quick start guide

Zektor HDVI5 user guide

Zektor

Zektor HDVI5 user guide

Polytron PSQ 1708 C user manual

Polytron

Polytron PSQ 1708 C user manual

Endress+Hauser t-switch technical information

Endress+Hauser

Endress+Hauser t-switch technical information

HP ProCurve 1600M Product End-of-Life Disassembly Instructions

HP

HP ProCurve 1600M Product End-of-Life Disassembly Instructions

H3C S5130-28F-EI Configuration guide

H3C

H3C S5130-28F-EI Configuration guide

Veris Industries Hawkeye 949 installation guide

Veris Industries

Veris Industries Hawkeye 949 installation guide

National Semiconductor DS10CP154EVK NOPB user manual

National Semiconductor

National Semiconductor DS10CP154EVK NOPB user manual

Honeywell Home 50027910-001 installation instructions

Honeywell Home

Honeywell Home 50027910-001 installation instructions

hager SP 802 User instructions

hager

hager SP 802 User instructions

Exsys EX-1181HMS-WT manual

Exsys

Exsys EX-1181HMS-WT manual

ABB NE801 user manual

ABB

ABB NE801 user manual

ZyXEL Communications VES-1616 Support notes

ZyXEL Communications

ZyXEL Communications VES-1616 Support notes

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.