1Applicable documents
Document Product Table of contents
Application note – Constraints for liquid handling, including media
resistance
Tab. 1
All available documents for the product è www.festo.com/sp.
2 Safety
2.1 Safety instructions
2.1.1 General safety instructions
–Only use the product in its original condition without unauthorised modifica-
tions.
–Only use the product if it is in perfect technical condition.
–Do not subject the product to mechanical stress.
–Before working on the product: switch off the power supply and medium supply
and secure it against being switched on again.
–Always grasp the plug by the housing. Do not pull on the cable.
–Comply with the handling specifications for electrostatically sensitive devices.
–The product can become hot during continuous operation, during operation in
block assembly and in the event of individual faults. Take suitable protective
measures when using and handling the product.
–Do not operate the product in the vicinity of highly flammable media and
substances.
–Use the product indoors only.
–Use the product in a dry environment only.
–The product may generate high frequency interference, which may require
interference suppression measures in residential areas.
–Do not exceed the maximum permissible pressure of the medium. Also take
potential pressure peaks in the system into account.
–Store the product in a cool, dry environment protected from UV and corrosion.
Keep storage times short.
2.1.2 Media
–Media may escape in the event of leakage. Take suitable protective measures
for use and handling of the product.
–When using crystallising media, plan appropriate rinsing routines for the
product.
–Use only media that will not cause dangerous reactions if mixed.
–Use only media to which the materials used for the product are resistant.
Materials in contact with the medium è 10 Technical data.
–For evaluation of the media resistance è 1 Applicable documents.
2.1.3 Return to Festo
Hazardous substances can endanger the health and safety of personnel and
cause damage to the environment. To prevent hazards, the product should only be
returned if explicitly requested by Festo.
–Consult your regional Festo contact.
–Complete the declaration of contamination and attach it to the outside of the
packaging.
–Comply with all legal requirements for the handling of hazardous substances
and the transport of dangerous goods.
2.2 Intended use
The solenoid valve VYKB is intended for installation in laboratory devices. The
product is used to control gaseous and liquid media within the limits of the
technical data. The chemical resistance of the materials of the product in contact
with the media must be tested for every application. The user is responsible for
validating the application.
–Operate the product only with a suitable sub-base. Observe the product label-
ling on the sub-base.
2.3 Foreseeable misuse
–Do not bring the product into direct contact with foods or their ingredients.
–Do not use the product in medical equipment used to maintain or monitor
human life.
–Do not operate the product in reverse.
2.4 Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel have skills and
experience in dealing with electrical (open-loop) control technology.
3 Additional information
–Contact the regional Festo contact if you have technical problems
è www.festo.com.
–Accessories è www.festo.com/catalogue.
4Product overview
4.1 Function
The product is a directly actuated directional control valve with solenoid coil. If
the solenoid coil is supplied with power, the LED on the electrical sub-base lights.
Product Circuit symbol Function
VYKB-...-M22C-... 2/2-way valve, normally closed (2) è (1)
VYKB-...-M32-... 3/2-way valve, normally closed (2) è (1) and opened
(2) è (3)
Tab. 2: Circuit symbols
4.2 Configuration
The product is a modular design. The connecting cable, the seal and the sub-base
are available as accessories. The seal is included in the scope of delivery.
1
1
2
2
3
3
4
4
Fig. 1: Product design
1
Sub-base VABS-K2-...
2
Seal VAVC-K2-...
3
Connecting cable NEBV-HPG2-...
4
Solenoid valve VYKB
5 Assembly
5.1 Valve mounting
Requirements
–The medium lines are unpressurised and do not carry any medium.
–The medium lines are free of particles and fibres.
–The medium line ends are mounted.
–Dirt filters are installed in the medium line upstream from the product. Max.
particle size: 5 µm.
–The power supply is switched off.
Mechanical
• Mount the product with the accompanying screws. Observe the following
tightening torque:
Product Thread size Tightening torque [Nm]
VYKB-F10 M2 0.16 … 0.2
VYKB-F12 M3 0.27 … 0.33
5.2 Mounting of medium connection
• Mount the fittings on the sub-base. Observe the following tightening torque:
Thread size Tightening torque [Nm]
M6, 1/4-28 UNF 1.5 … 1.8
6 Installation
6.1 Fluid installation
1 2 3
4
Fig. 2: Fluid connections
1
only 3/2-way valve: channel (3) "N/O"
2
Channel (2) "COM"
3
Channel (1) "N/C"
4
Seal
6.2 Electrical installation
WARNING
Risk of Injury due to Electric Shock.
• For the electric power supply, use only PELV circuits that ensure a reliable
electric disconnection from the mains network.
•Observe IEC 60204-1/EN 60204-1.
• The unit must be powered by a power source that fulfils the requirements of an
energy-limited circuit in accordance with IEC 61010-1/EN 61010-1.
–Note polarity (red cable = +).
–Observe maximum cable length of 10 m.
–Insert the plug.
7 Commissioning
Requirements
–The product is fully mounted and connected.
Commissioning the product
1. Switch on the media supply.
2. Switch on the power supply.
3. Check the product for leakage.
8 Maintenance
–Inspect the product regularly from the outside for leakage and function.
–Clean the outside of the product as required with a soft dry cloth.
9 Disassembly
1. Switch off the power supply.
2. Depressurise the valve and medium line and allow them to cool.
3. Drain the medium line and valve completely. Collect the discharged media in a
suitable container.
4. Disassemble the valve. Do not pull on the cable. Unlock the locking lug when
removing the plug.
10 Technical data
VYKB -F10 -F12
Technical data, general
Design Rocker valve with diaphragm seal
Installation location use only indoors
Mounting position any
Degree of protection IP40
Flow direction non-reversible
Information on materials Contains paint-wetting impairment substances1)
Min. grid dimension with
block mounting
[mm] 11 13
Load
Vibration severity level 2 in accordance with IEC 60068
Shock severity level 2 in accordance with IEC 60068
Temperature range
Medium [°C] 0 … 50
Environment [°C] 0 … 50
Storage [°C] −20 … +70
Port
fluidic Flange with additional sub-base VABS; 1/4-28 UNF; M6
Electrical Connecting cable NEBVHPG2-PN0.3NLE2
VYKB -F10 -F12
Technical data, fluidic
Medium –liquid media
–gaseous media
Max. contamination level of
the medium
[µm] 5
Materials in contact with the
medium
PEEK, EPDM, FFKM, FKM PEEK, EPDM
Pressure of medium [MPa] −0.075 … +0.1 −0.075 … +0.3
Flow rate Kv [m³/h] 0.034 0.0558
Internal volume [µl] 35 60
Technical data, electrical
Nominal operating voltage
VYKB-...-5 [V DC] 12 +10 %, −5 %
VYKB-...-1 [V DC] 24 ±10 %
Max. switching frequency [Hz] 2
Duty cycle [%] 100
Overvoltage category II
Contamination level 2 2
Max. power consumption
Inrush current
VYKB-...-5 [W] 3.7 5.2
VYKB-...-1 [W] 3.7 4.5
Holding current [W] 1 1
Inrush current
VYKB-...-5 [mA] 308 433
VYKB-...-1 [mA] 154 188
Holding current
VYKB-...-5 [mA] 83 84
VYKB-...-1 [mA] 42 42
1) PWIS = paint-wetting impairment substances
Tab. 3: Technical data
Type of severity level (SL)
Vibration load
Frequency range [Hz] Acceleration [m/s2]Deflection [mm]
SL1 SL2 SL1 SG2 SL1 SL2
2 … 8 2 … 8 – – ±3.5 ±3.5
8 … 27 8 … 27 10 10 – –
27 … 58 27 … 60 – – ±0.15 ±0.35
58 … 160 60 … 160 20 50 – –
160 … 200 160 … 200 10 10 – –
Shock load
Acceleration [m/s2]Duration [ms] Shocks per direction
SL1 SL2 SL1 SL2 SL1 SL2
±150 ±300 11 11 5 5
Continuous shock load
Acceleration [m/s2]Duration [ms] Shocks per direction
±150 6 1000
Tab. 4: Type of severity level (SL)

This manual suits for next models

1

Other Festo Control Unit manuals

Festo VEAB Series User manual

Festo

Festo VEAB Series User manual

Festo CPX-CM-HPP Parts list manual

Festo

Festo CPX-CM-HPP Parts list manual

Festo CPX-AP-I-8DI-M12-5P Parts list manual

Festo

Festo CPX-AP-I-8DI-M12-5P Parts list manual

Festo CAMC-G-S3 User manual

Festo

Festo CAMC-G-S3 User manual

Festo ZSB-1/8-B User manual

Festo

Festo ZSB-1/8-B User manual

Festo VZQA-C-M22C-6-GG-V2V4E-1 User manual

Festo

Festo VZQA-C-M22C-6-GG-V2V4E-1 User manual

Festo CAPC-F1-E-M12 User manual

Festo

Festo CAPC-F1-E-M12 User manual

Festo CPX-E-4IOL User manual

Festo

Festo CPX-E-4IOL User manual

Festo CPX-E-EP User manual

Festo

Festo CPX-E-EP User manual

Festo CDVI5.0 User manual

Festo

Festo CDVI5.0 User manual

Festo HMPL-20 Series User manual

Festo

Festo HMPL-20 Series User manual

Festo CMGA Series User manual

Festo

Festo CMGA Series User manual

Festo VZQA-C-M22U User manual

Festo

Festo VZQA-C-M22U User manual

Festo SPC200-SMX-1 Parts list manual

Festo

Festo SPC200-SMX-1 Parts list manual

Festo CTEU-CO Parts list manual

Festo

Festo CTEU-CO Parts list manual

Festo Soft Stop SPC11 Series User guide

Festo

Festo Soft Stop SPC11 Series User guide

Festo CPX-E-PN User manual

Festo

Festo CPX-E-PN User manual

Festo LFR-D Series User manual

Festo

Festo LFR-D Series User manual

Festo MH1 Series Parts list manual

Festo

Festo MH1 Series Parts list manual

Festo HSP-AE-IO Series Reference guide

Festo

Festo HSP-AE-IO Series Reference guide

Festo VUVG 1T1L Series User manual

Festo

Festo VUVG 1T1L Series User manual

Festo Compact Performance CP-FB6-E Parts list manual

Festo

Festo Compact Performance CP-FB6-E Parts list manual

Festo MS6N-SV Installation instructions

Festo

Festo MS6N-SV Installation instructions

Festo VZWM-L-M22C User manual

Festo

Festo VZWM-L-M22C User manual

Popular Control Unit manuals by other brands

Allen-Bradley Series B user manual

Allen-Bradley

Allen-Bradley Series B user manual

Smarteh LPC-2.CX1 user manual

Smarteh

Smarteh LPC-2.CX1 user manual

Flashcut CNC 401A Hardware guide

Flashcut CNC

Flashcut CNC 401A Hardware guide

SEW-Eurodrive BMV operating instructions

SEW-Eurodrive

SEW-Eurodrive BMV operating instructions

ICM Controls ICM275 installation instructions

ICM Controls

ICM Controls ICM275 installation instructions

Infineon TLE9262-3BQX manual

Infineon

Infineon TLE9262-3BQX manual

RS EDP-CM-1113 Getting started guide

RS

RS EDP-CM-1113 Getting started guide

Hispacold Ecomaster Comfort MH-083 manual

Hispacold

Hispacold Ecomaster Comfort MH-083 manual

Comunello QUAD - 24V - 2M Installation and user manual

Comunello

Comunello QUAD - 24V - 2M Installation and user manual

PT Coupling Maxi-Dry Disassembly instructions

PT Coupling

PT Coupling Maxi-Dry Disassembly instructions

Nibe SMO S40 user manual

Nibe

Nibe SMO S40 user manual

Teracom TCW122B-CM user manual

Teracom

Teracom TCW122B-CM user manual

Metal Work HDM user manual

Metal Work

Metal Work HDM user manual

Bosch MP 100 Installation instruction

Bosch

Bosch MP 100 Installation instruction

Emerson Bettis XTE3000 Installation, operation and maintenance manual

Emerson

Emerson Bettis XTE3000 Installation, operation and maintenance manual

Marcum Technologies RT-9 quick start guide

Marcum Technologies

Marcum Technologies RT-9 quick start guide

Lenze E82ZAFCC210 Mounting instructions

Lenze

Lenze E82ZAFCC210 Mounting instructions

GMI D5099S instruction manual

GMI

GMI D5099S instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.