Quarter turn actuator DFPD-HD-...-RD English.............................
1 About this document
This document describes the use of the above-mentioned product. Certain aspects
of use connected to a hydraulic unit or handwheel control are described in other
documents and must be observed èChap. 1.1.
All available documents for the product èwww.festo.com/pk
1.1 Applicable documents
Document Table of contents
DFPD-HD-...-HW operating instructions Mounting, commissioning and operation of the
hydraulic unit
DFPD-HD-...-MW operating instructions Mounting, commissioning and operation of the
handwheel control
Fig. 1
2 Safety
 Take into consideration the legal regulations for the respective destination.
 Observe product labelling.
 Before carrying out mounting, dismantling, installation and maintenance work,
switch off the compressed air supply and vent the drive. Secure compressed air
supply against accidental restarting.
Return to Festo
Hazardous substances can endanger the health and safety of personnel and cause
damage to the environment. To prevent hazards, the product should only be
returned upon explicit request by Festo.
 Consult your regional Festo contact.
 Complete the declaration of contamination and attach it to the outside of the
packaging.
 Comply with all legal requirements for handling hazardous substances and
transporting dangerous goods.
3 Use for intended purpose
The DFPD-HD quarter turn actuator is intended to activate process valves, such as
ball valves and butterfly shut-off valves with a rotation angle from 0° (valve closed)
to 90°. The quarter turn actuator is suitable for controlling media-flow process
valves in fluid engineering systems.
 The product may only be used in its original status without unauthorized
modifications.
 Only use the product if it is in perfect technical condition.
 Observe the specifications on the product labelling.
Note
The operating torque of the drive must not be higher than the maximum per
missible torque listed in ISO 5211, with reference to the size of the mounting
flange and of the coupling.
Operating medium
 Only use compressed air in accordance with the specifications
èTechnicaldata.
 Only use unlubricated compressed air under normal conditions. Once the
product has been used with lubricated compressed air, it must continue to
beoperated with compressed air only.
4 Further information
– Accessories èwww.festo.com/catalogue
– Documents and literature èwww.festo.com/sp
5 Service
 Contact the regional Festo contact if you have technical questions
èwww.festo.com.
6 Product overview
The product label can be found on the gear unit.
6.1 Function
The DFPD-HD-...-RD is a double-acting quarter turn
actuator. The piston is moved by pressurizing and
exhausting the pneumatic cylinder.
The linear motion of the piston is transformed via a Scotch yoke system into
aswivel motion of the transmission shaft. The connected process valve records
the moment of reaction of the quarter turn actuator.
Fig. 2
6.2 Layout
2
34
78
5
6
1
6
9aJ aA
7
18 mounting threads
according to ISO 5211
2Parallel key groove
3Pneumatic cylinder
44 mounting threads – e.g.,
forsensor box
5Transmission shaft (internal) –
delivery “Valve open”
6Adjustable stop for end-position
adjustment
7Transport lug
8Gear units
9Mechanical position indication
aJ Supply port (4)
aA Supply port (2)
Fig. 3
7 Transport and storage
Warning
Danger of crushing!
The product without accessories weighs up to about 1500 kg, depending on the
product version.
Body parts can be crushed if the product falls.
 Use appropriate load handling equipment.
 Use the 3 transport lugs to life the quarter turn actuator (Fig. 3, 7).
 Loosen the quarter turn actuator before transporting the process valve.
Note
For variants with a hydraulic unit (DFPD-HD-...-HW): environmental damage due
to escaping oil.
 Store the product horizontally and avoid inclines.
 Observe environmental and storage conditions èTechnical data.
 To prevent contamination, close any pneumatic connections.
 Protect the coupling parts with grease or protective oil.
 To prevent damage to the coupling flange, store the quarter turn actuator on an
even wooden pallet.
 Store the product in a cool, dry, UV-protected and corrosion-protected
environment.
 In case of long-term storage: regularly check the function of the quarter turn
actuator.
 When shipping used products: comply with all legal requirements for handling
hazardous substances and transporting dangerous goods.
For return to Festo èChap. 2.
8 Mounting and installation
Note
Installation should only be conducted by qualified specialized personnel.
Note
Quarter turn actuators of the series DFPD-HD are intended for installation in
parallel with the line axis.
 If another mounting position is necessary, consult your regional Festo contact
èwww.festo.com.
Note
Quarter turn actuators with a hydraulic manual override are designed for a
horizontal mounting position only. In this position, the pump and reservoir as
mounted towards the top of the hydraulic cylinder.
8.1 Mounting
1. Clean the coupling flange.
2. Adjust the valve position according to the quarter turn actuator settings.
3. Lubricate the valve stem.
4. Place the quarter turn actuator on the switching shaft of the process valve.
5. Fasten the quarter turn actuator to the connecting flange of the process valve
with 8 threaded pins.
6. Tighten the nuts of the threaded pin crosswise
Tightening torque èFig. 4
Flange type F25 F30 F35
Tightening torques [Nm] 160 320 1100
Fig. 4
8.2 Pneumatic installation
 Observe the operating instructions of the process valve.
 Test the correct function of the pneumatic control.
Port Effect
2Air supply; always actuated
4Return stroke
Fig. 5
9 Commissioning
Note
Commissioning should only be carried out by qualified personnel.
Prerequisites
– The drive is fully mounted and connected.
1. Check operating conditions and limit values èTechnical data.
2. Switch on the compressed air supply.
3. Check the quarter turn actuator for leakage.
4. First check the direction of rotation of the quarter turn actuator and reaction of
the process valve at a low travel speed.
9.1 Adjusting the end position – “Valve closed” position
The “Valve closed” position is adjusted using the adjusting screw on the end flange
of the pneumatic cylinder.
1
2
3
4
5
6
Fig. 6
1. Put the quarter turn actuator in the “Valve closed” position 1.
2. Switch off the compressed air supply.
3. Remove the cover of the stop bolt 2 and sealing disc 3.
4. Loosen the stop nut 5together with the sealing disc 6.
5. To reduce the rotation angle, screw in the stop adjusting screw 4.
To increase the rotation angle, unscrew the stop adjusting screw 4.
6. Tighten the stop nut 5. Make sure that the sealing disc 6 is centred on the
stop nut and lies in the recess of the flange.
7. Switch on the compressed air supply.
8. To check the adjustment, run through a complete cycle.
9. Put the cover of the stop bolt 2and sealing disc 3into place again.
9.2 Adjusting the end position – “Valve open” position
The “Valve open” position is adjusted using the adjusting screw on the end flange
of the gear unit.
5
4
3
2
1
6
Fig. 7
1. Put the quarter turn actuator in the “Valve open” position 1.
2. Switch off the compressed air supply.
3. Remove the cover of the stop bolt 2 and sealing disc 3.
4. Loosen the stop nut 5together with the sealing disc 6.
5. To reduce the rotation angle, screw in the stop adjusting screw 4.
To increase the rotation angle, unscrew the stop adjusting screw 4.
6. Tighten the stop nut 5. Make sure that the sealing disc 6 is centred on the
stop nut and lies in the recess of the flange.
7. Switch on the compressed air supply.
8. To check the adjustment, run through a complete cycle.
9. Put the cover of the stop bolt 2and sealing disc 3into place again.
10 Operation
 Comply with operating conditions.
 Observe the permitted limit values.
Note
Use lubricated compressed air for continuous operation under extreme
conditions. The oil must be chemically inert and must not carbonise. After the
initial use of lubricated compressed air, it is required in continued operation.
11 Fault clearance
 In case of malfunctions, consult your regional Festo contact.
12 Service
When used as intended, the product is maintenance-free.
Festo recommends the following periodic inspections:
Interval Inspection
Annually Correct function of the quarter turn actuator by
repeatedly opening and closing the valve
(rotation angle = 90°)
Every six months Visual inspection (during operation)
Quarterly Correct function of the quarter turn actuator during
operation
Fig. 8
13 Dismantling
Note
Disassembly only by qualified specialized personnel.
Warning
Danger of crushing!
The product without accessories weighs up to about 1500 kg, depending on the
product version.
Body parts can be crushed if the product falls.
 Use appropriate load handling equipment.
 Use the 3 transport lugs to life the quarter turn actuator (Fig. 3, 7).
 Loosen the quarter turn actuator before dismantling the process valve.
Warning
Risk of injury due to uncontrolled movements.
 Depressurise the pipeline before dismantling the quarter turn actuator.
1. Disconnect the quarter turn actuator from the compressed air supply.
2. Loosen the pneumatic connections.
3. Loosen the mounting screws of the quarter turn actuator.
4. Lift the quarter turn actuator off the process valve.
14 Disposal
 Observe the local regulations for environmentally friendly disposal.
 Dispose of the product in an environmentally friendly manner. When doing this,
also take residual media into account (potential recycling of hazardous waste).
15 Technical data
DFPD
Operating medium Compressed air in accordance with
ISO8573-1:2010 [7:4:4] 1)
Note on the operating medium Lubricated operation possible
(required in further operation)
Ambient temperature [°C] –20…+80
Rotation angle [°] 0…90
Mounting position Parallel to line axis
(DFPD-HD-...-HW horizontal only)
Pneumatic port G½, G1
Standard connection to the process valve ISO 5211
CE marking (see declaration of conformity
èwww.festo.com/sp)
As per EU Explosion Protection Directive
(ATEX)
To EC Machinery Directive
Operating conditions
Operating pressure [bar] 3…8.5
Nominal operating pressure [bar] 5.0
End position adjustment range 0° [°] ± 5
End position adjustment range 90° [°] ± 5
Degree of protection IP66M, IP67M
Materials
Housing Steel
Cap Steel
Pneumatic cylinder Steel (nickel-plated)
Piston rod Steel (chrome-plated)
Piston Steel
Guide rod Steel
Stop adjusting screw Steel
Seal NBR, polyurethane
Ceiling paintjob Polyurethane
1) Note: Pressure dew point at least 10 °C below the outside temperature.
Fig. 9

Other manuals for DFPD-Series

5

This manual suits for next models

1

Other Festo Controllers manuals

Festo CMMS-ST-C8-7-G2 Guide

Festo

Festo CMMS-ST-C8-7-G2 Guide

Festo CMMP-AS-***-M3 Series User manual

Festo

Festo CMMP-AS-***-M3 Series User manual

Festo SPC200 Series User manual

Festo

Festo SPC200 Series User manual

Festo CMMP-AS-C5-3A-M0 Guide

Festo

Festo CMMP-AS-C5-3A-M0 Guide

Festo VPPM C1 Series User manual

Festo

Festo VPPM C1 Series User manual

Festo SPC11 Series Instructions and recipes

Festo

Festo SPC11 Series Instructions and recipes

Festo FEC-FC640 User manual

Festo

Festo FEC-FC640 User manual

Festo CDSA-D1-VX User manual

Festo

Festo CDSA-D1-VX User manual

Festo CMMP-AS-***-M0 Series Operating and installation instructions

Festo

Festo CMMP-AS-***-M0 Series Operating and installation instructions

Festo ELCC-TB User manual

Festo

Festo ELCC-TB User manual

Festo CPX-E-CEC EP Series User manual

Festo

Festo CPX-E-CEC EP Series User manual

Festo SPC200 Series User manual

Festo

Festo SPC200 Series User manual

Festo MPP-3-1/8 User manual

Festo

Festo MPP-3-1/8 User manual

Festo LRP-1/4 Series User manual

Festo

Festo LRP-1/4 Series User manual

Festo SFC-DC-VC-3-E-H0-CO Reference guide

Festo

Festo SFC-DC-VC-3-E-H0-CO Reference guide

Festo CECX-X-C1 Series User manual

Festo

Festo CECX-X-C1 Series User manual

Festo VPPI S1D Series User manual

Festo

Festo VPPI S1D Series User manual

Festo CMMS-ST-C8-7-G2 User manual

Festo

Festo CMMS-ST-C8-7-G2 User manual

Festo EGSP Series User manual

Festo

Festo EGSP Series User manual

Festo 32 MPA User manual

Festo

Festo 32 MPA User manual

Festo LF-M Series User manual

Festo

Festo LF-M Series User manual

Festo CPX-CMAX Operating and installation instructions

Festo

Festo CPX-CMAX Operating and installation instructions

Festo CMMD-AS series User manual

Festo

Festo CMMD-AS series User manual

Festo CMSX-...-C-U-F1 series User manual

Festo

Festo CMSX-...-C-U-F1 series User manual

Popular Controllers manuals by other brands

GCE druva PPLH0FT Instructions for use

GCE druva

GCE druva PPLH0FT Instructions for use

Enttec S-PLAY user manual

Enttec

Enttec S-PLAY user manual

Reefe RPC22HM Operation Guide & Instruction Manual

Reefe

Reefe RPC22HM Operation Guide & Instruction Manual

Cito System PC/104 user manual

Cito System

Cito System PC/104 user manual

Horst HT MC11 instruction manual

Horst

Horst HT MC11 instruction manual

Isimet DLA Series Installation, Operations, Start-up and Maintenance Instructions

Isimet

Isimet DLA Series Installation, Operations, Start-up and Maintenance Instructions

Sun21 MAX-M2024 user manual

Sun21

Sun21 MAX-M2024 user manual

MDT Technologies SCN-RTRGW.02 Technical manual

MDT Technologies

MDT Technologies SCN-RTRGW.02 Technical manual

Tekmar House Control 401 Quick setup guide

Tekmar

Tekmar House Control 401 Quick setup guide

CDVI SOLAR2R installation manual

CDVI

CDVI SOLAR2R installation manual

Sun Yeh Electrical OME Series Operation manual

Sun Yeh Electrical

Sun Yeh Electrical OME Series Operation manual

Deep Sea Electronics Plc 8620 Installation instructions and instructions for use

Deep Sea Electronics Plc

Deep Sea Electronics Plc 8620 Installation instructions and instructions for use

Siemens 3RE4 instructions

Siemens

Siemens 3RE4 instructions

SOMFY animeo LON 1860277 installation guide

SOMFY

SOMFY animeo LON 1860277 installation guide

Eaton RMQ-Titan M22 Series Instruction leaflet

Eaton

Eaton RMQ-Titan M22 Series Instruction leaflet

wattio GATE manual

wattio

wattio GATE manual

Bosch Rexroth IndraDrive MPH-02 Functional description

Bosch

Bosch Rexroth IndraDrive MPH-02 Functional description

KROHNE DW 18 Series Supplementary instructions

KROHNE

KROHNE DW 18 Series Supplementary instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.