GEM eSyDrive 567 User manual

GEMÜ 567 eSyDrive
Aseptic control valve with motorized eSyDrive actuator
Operating instructions
EN
further information
webcode: GW-567

All rights including copyrights or industrial property rights are expressly reserved.
Keep the document for future reference.
© GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG
23.11.2022
www.gemu-group.com2 / 60GEMÜ 567 eSyDrive

Contents
1 General information ............................................. 4
1.1 Information .................................................... 4
1.2 Symbols used ................................................ 4
1.3 Definition of terms ........................................ 4
1.4 Warning notes ............................................... 4
2 Safety information ............................................... 5
3 Product description ............................................. 5
4 Correct use .......................................................... 9
5 GEMÜ CONEXO .................................................... 9
6 Order data - eSyDrive ........................................... 10
7 Technical data ..................................................... 12
8 Dimensions .......................................................... 18
9 Manufacturer's information .................................. 39
9.1 Delivery .......................................................... 39
9.2 Packaging ...................................................... 39
9.3 Transport ....................................................... 39
9.4 Storage ........................................................... 39
10 Installation in piping ............................................ 39
10.1 Installation location ....................................... 39
10.2 Preparing for installation .............................. 39
10.3 Installation with clamp connections ............ 40
10.4 Installation with butt weld spigots ............... 40
11 Mounting ............................................................. 41
12 Electrical connection ........................................... 42
13 Commissioning .................................................... 45
13.1 Commissioning on the device ...................... 45
13.2 Commissioning via the eSy-Web web inter-
face ................................................................ 45
13.3 Commissioning via digital input ................... 45
14 Troubleshooting .................................................. 46
15 Inspection and maintenance ................................ 47
16 Removal from piping ............................................ 56
17 Disposal .............................................................. 56
18 Returns ................................................................ 56
19 Declaration of Incorporation according to
2006/42/EC (Machinery Directive) ....................... 57
20 Declaration of conformity according to 2014/68/
EU (Pressure Equipment Directive) ...................... 58
21 Declaration of conformity according to 2014/30/
EU (EMC Directive) ............................................... 59
GEMÜ 567 eSyDrivewww.gemu-group.com 3 / 60

www.gemu-group.com4 / 60GEMÜ 567 eSyDrive
1 General information
1 General information
1.1 Information
- The descriptions and instructions apply to the standard ver-
sions. For special versions not described in this document
the basic information contained herein applies in combina-
tion with any additional special documentation.
- Correct installation, operation, maintenance and repair work
ensure faultless operation of the product.
- Should there be any doubts or misunderstandings, the Ger-
man version is the authoritative document.
- Contact us at the address on the last page for staff training
information.
1.2 Symbols used
The following symbols are used in this document:
Symbol Meaning
Tasks to be performed
Response(s) to tasks
– Lists
1.3 Definition of terms
Working medium
The medium that flows through the GEMÜ product.
PD
PD = Plug Diaphragm
1.4 Warning notes
Wherever possible, warning notes are organised according to
the following scheme:
SIGNAL WORD
Type and source of the danger
Possible
symbol for the
specific
danger
Possible consequences of non-observance.
Measures for avoiding danger.
Warning notes are always marked with a signal word and
sometimes also with a symbol for the specific danger.
The following signal words and danger levels are used:
DANGER
Imminent danger!
▶Non-observance can cause death or
severe injury.
WARNING
Potentially dangerous situation!
▶Non-observance can cause death or
severe injury.
CAUTION
Potentially dangerous situation!
▶Non-observance can cause moderate
to light injury.
NOTICE
Potentially dangerous situation!
▶Non-observance can cause damage to
property.
The following symbols for the specific dangers can be used
within a warning note:
Symbol Meaning
Danger of explosion!
Corrosive chemicals!
Hot plant components!
Danger - high voltage!

www.gemu-group.com 5 / 60 GEMÜ 567 eSyDrive
2 Safety information
The safety information in this document refers only to an indi-
vidual product. Potentially dangerous conditions can arise in
combination with other plant components, which need to be
considered on the basis of a risk analysis. The operator is re-
sponsible for the production of the risk analysis and for com-
pliance with the resulting precautionary measures and re-
gional safety regulations.
The document contains fundamental safety information that
must be observed during commissioning, operation and main-
tenance. Non-compliance with these instructions may cause:
- Personal hazard due to electrical, mechanical and chemical
effects.
- Hazard to nearby equipment.
- Failure of important functions.
- Hazard to the environment due to the leakage of dangerous
substances.
The safety information does not take into account:
- Unexpected incidents and events, which may occur during
installation, operation and maintenance.
- Local safety regulations which must be adhered to by the
operator and by any additional installation personnel.
Prior to commissioning:
1. Transport and store the product correctly.
2. Do not paint the screws and plastic parts of the product.
3. Carry out installation and commissioning using trained
personnel.
4. Provide adequate training for installation and operating
personnel.
5. Ensure that the contents of the document have been fully
understood by the responsible personnel.
6. Define the areas of responsibility.
7. Observe the safety data sheets.
8. Observe the safety regulations for the media used.
During operation:
9. Keep this document available at the place of use.
10. Observe the safety information.
11. Operate the product in accordance with this document.
12. Operate the product in accordance with the specifications.
13. Maintain the product correctly.
14. Do not carry out any maintenance work and repairs not de-
scribed in this document without consulting the manufac-
turer first.
In cases of uncertainty:
15. Consult the nearest GEMÜ sales office.
3 Product description
3.1 Construction
3.1.1 Construction
6
8
1
2
3
4
7
5
Item Name Materials
1 O-rings EPDM
2 Electrical connections
3 Actuator base 1.4301
4 Distance piece 1.4408
5 Valve body with leak de-
tection hole
1.4435
6 CONEXO RFID chip
7 Optical position indicator PESU
8 Cover with high visibility
LED, manual override and
on-site control
PESU
3 Product description

www.gemu-group.com6 / 60GEMÜ 567 eSyDrive
3 Product description
3.1.2 Buttons for on-site control
8
9
10
Fig.1: Position of the buttons
Item Name Function
8 DIP switch, "ON-
site" control
Switches the on-site
control on the device
on or off
9 "OPEN" button Moves actuator to the
open position
Resets the network
settings
10 "INIT/CLOSE" but-
ton
Moves actuator to the
closed position
Starting initialisation
3.1.3 LED displays
3.1.3.1 On-site status LEDs
LED MODE LED PWR
Fig.2: Position of the status LEDs
The user checks the following conditions directly on-site at
the valve using LED MODE and LED PWR:
Function LED MODE LED PWR
Yellow Blue Green Red
Automatic oper-
ation
Manual opera-
tion
Actuator
switched off
(OFF mode)
Manual opera-
tion (on-site)
Software update
alternating
On-site initialisa-
tion (buttons)
Remote initial-
isation (via Di-
gIn)

www.gemu-group.com 7 / 60 GEMÜ 567 eSyDrive
Function LED MODE LED PWR
Yellow Blue Green Red
Operation via
emergency
power supply
module
3.1.3.2 High visibility LEDs
11
11 11
11 11
11
Fig.3: Position of the high visibility LEDs
Item Name
11 High visibility LEDs
Function High visibility LED
Green Orange
OPEN position Position indicator
LEDs,
standard
OPEN position Position indicator
LEDs,
inversed
CLOSED position Position indicator
LEDs,
standard
CLOSED position Position indicator
LEDs,
inversed
Position unknown (e.g. 50%)
Initialisation
Function High visibility LED
Green Orange
alternating
Location function
3.2 Description
The GEMÜ 567 eSyDrive 2/2-way diaphragm globe valve is a
precise motorized control valve for sterile applications. The
GEMÜ eSyDrive hollow shaft actuator can be operated as an
actuator with integrated positioner or process controller. Flow
rates range from 80 l/h to 63 m³/h, depending on the version.
3.3 Function
The product controls or regulates (depending on version) a
flowing medium by being closed or opened by a motorized ac-
tuator.
The product has an optical position indicator as standard. The
optical position indicator indicates the OPEN and CLOSED po-
sitions.
3 Product description

3.4 PD seal system without bypass
Seal material code 4 Seal material code 5
1234 5
Item Name Materials
1 Plug diaphragm PTFE
2 Support ring 1.4435 (316L)
3 O-ring FKM
4 Regulating cone 1.4435 (316L)
5 PTFE plug diaphragm with regulating cone
3.5 PD seal system with bypass
only for actuator size 2
5
3
2
4
1
Item Name Materials
1 Plug diaphragm FKM, PTFE PTFE
2 Support ring 1.4435 (316L)
3 O-ring FKM
4 Regulating cone 1.4435 (316L)
5 Bypass valve diaphragm
www.gemu-group.com8 / 60GEMÜ 567 eSyDrive
3 Product description

www.gemu-group.com 9 / 60 GEMÜ 567 eSyDrive
3.6 Installation position for optimized draining
in closed and open position in open position
Actuator horizontal Actuator horizontal or vertical
Control range
We recommend designing the valves in such a way that the
control range is within an opening stroke of 20% to 90% of the
control valve.
3.7 Product label
The product label is located on the actuator. Product label
data (example):
Design in accordance with order
data
Item number
Device-specific data
Year of manufacture
Traceability number Counting number
12103529 I0001
The month of manufacture is encoded in the traceability num-
ber and can be obtained from GEMÜ. The product was manu-
factured in Germany.
4 Correct use
DANGER
Danger of explosion!
▶Risk of death or severe injury
●Do not use the product in potentially
explosive zones.
WARNING
Improper use of the product!
▶Risk of severe injury or death
▶Manufacturer liability and guarantee will be void
●Only use the product in accordance with the operating
conditions specified in the contract documentation and in
this document.
The product is designed for installation in piping systems and
for controlling a working medium.
The product is not intended for use in potentially explosive
areas.
●Use the product in accordance with the technical data.
5 GEMÜ CONEXO
For electronic identification purposes, each replaceable com-
ponent contained in the product you have purchased is
equipped with an RFID chip (1). Where you can find the RFID
chip differs from product to product.
1
Fig.4: Actuator RFID chip
1
Fig.5: Diaphragm RFID chip
1
Fig.6: Valve body RFID chip
The CONEXO pen helps read out information stored in these
RFID chips. The CONEXO app or CONEXO portal is required to
view this information.
5 GEMÜ CONEXO

6 Order data - eSyDrive
The order data provide an overview of standard configurations.
Please check the availability before ordering. Other configurations available on request.
Order codes
1 Type Code
Control valve 567
2 DN Code
DN 8 8
DN 10 10
DN 15 15
DN 20 20
DN 25 25
DN 32 32
DN 40 40
DN 50 50
DN 65 65
3 Body configuration Code
2-way angle body E
2-way angle body with bypass M
4 Connection type Code
Spigot
Spigot DIN 0
Spigot EN 10357 series A (formerly DIN 11850 series
2)/DIN 11866 series A
17
Spigot ASME BPE / DIN 11866 series C 59
Spigot ISO 1127/EN 10357 series C/DIN 11866 series B 60
Clamp
Clamp DIN 32676 series B 82
Clamp DIN 32676 series A 86
Clamp ASME BPE 88
5 Valve body material Code
1.4435 (316L), block material 41
1.4435 (BN2), block material, Δ Fe < 0.5% 43
6 Seal material Code
Actuator seal PTFE / seat seal FKM 4
Actuator seal PTFE / seat seal PTFE 5
Actuator seal PTFE / seat seal FKM / bypass seal EPDM
bypass diaphragm code 13
43
Actuator seal PTFE / seat seal FKM / bypass seal PTFE
bypass diaphragm code 54
45
Actuator seal PTFE / seat seal FKM / bypass seal EPDM
bypass diaphragm code 17
47
Actuator seal PTFE / seat seal PTFE / bypass seal PTFE
bypass diaphragm code 54
55
Actuator seal PTFE / seat seal FFKM F
Actuator seal PTFE / seat seal FFKM / bypass seal
PTFE
bypass diaphragm code 54
F5
7 Voltage/Frequency Code
24 V DC C1
8 Control module Code
OPEN/CLOSE, positioner and process controller L0
9 Control characteristic Code
Modified equal-percentage G
Linear L
10 Kv value Code
80l/h AA
100 l/h AB
160 l/h BC
250 l/h BD
400 l/h BE
630 l/h CF
1.0 m³/h CG
1.6 m³/h DH
2.6 m³/h EJ
4.1 m³/h G1
8.0 m³/h H2
12.5 m³/h J3
14.0 m³/h K4
18.0 m³/h K5
25.0 m³/h K6
32.0 m³/h M7
40.0 m³/h M8
50.0 m³/h N9
63.0 m³/h NK
11 Bypass actuator version Code
Pneumatically operated, normally closed, diaphragm
size 8,
11
Pneumatically operated, normally open, diaphragm size
8,
12
Manually operated, with seal adjuster, diaphragm size 8, S0
12 Surface Code
Ra ≤ 0.25 µm (10 µin.) for media wetted surfaces *),
in accordance with DIN 11866 HE5,
electropolished internal/external,
*) for inner pipe diameters < 6 mm, in the spigot Ra ≤
0.38 µm
1516
Ra ≤ 0.25 μm (10 µin.) for media wetted surfaces *),
in accordance with DIN 11866 H5,
mechanically polished internal,
*) for inner pipe diameters < 6 mm, in the spigot Ra ≤
0.38 μm
1527
Ra ≤ 0.4 µm (15 µin.) for media wetted surfaces,
in accordance with DIN 11866 H4,
mechanically polished internal
1536
6 Order data - eSyDrive
www.gemu-group.com10 / 60GEMÜ 567 eSyDrive

12 Surface Code
Ra ≤ 0.4 µm (15 µin.) for media wetted surfaces,
in accordance with DIN 11866 HE4,
electropolished internal/external
1537
Ra max. 0.51 µm (20 µin.) for media wetted surfaces,
in accordance with ASME BPE SF1,
mechanically polished internal
SF1
Ra max. 0.38 µm (15 µin.) for media wetted surfaces,
in accordance with ASME BPE SF4,
electropolished internal/external
SF4
Ra max. 0.51 µm (20 µin.) for media wetted surfaces,
in accordance with ASME BPE SF5,
electropolished internal/external
SF5
13 Actuator+interface Code
eSyDrive and analogue DA
14 Special version Code
Special version for 3A M
15 CONEXO Code
Without
Integrated RFID chip for electronic identification and
traceability
C
Order example without bypass
Ordering option Code Description
1 Type 567 Control valve
2 DN 15 DN 15
3 Body configuration M 2-way angle body with bypass
4 Connection type 17 Spigot EN 10357 series A (formerly DIN 11850 series 2)/DIN 11866
series A
5 Valve body material 41 1.4435 (316L), block material
6 Seal material 55 Actuator seal PTFE / seat seal PTFE / bypass seal PTFE
bypass diaphragm code 54
7 Voltage/Frequency C1 24 V DC
8 Control module L0 OPEN/CLOSE, positioner and process controller
9 Control characteristic G Modified equal-percentage
10 Kv value G1 4.1 m³/h
11 Bypass actuator version S0 Manually operated, with seal adjuster, diaphragm size 8,
12 Surface 1536 Ra ≤ 0.4 µm (15 µin.) for media wetted surfaces,
in accordance with DIN 11866 H4,
mechanically polished internal
13 Actuator+interface DA eSyDrive and analogue
14 Special version M Special version for 3A
15 CONEXO C Integrated RFID chip for electronic identification and traceability
6 Order data - eSyDrive
www.gemu-group.com 11 / 60 GEMÜ 567 eSyDrive

7 Technical data
7.1 Medium
Working medium: Corrosive, inert, gaseous and liquid media which have no negative impact on the physical and
chemical properties of the body and diaphragm material.
7.2 Temperature
Media temperature: Without bypass -10 — 160 °C
With bypass -10 — 100 °C
Observe pressure/temperature diagram
Sterilization temperature: Seat seal FKM, FFKM without bypass,
(code 4, F)
160 °C 1), steam max. 30 min 2)
Seat seal PTFE without bypass, (code 5) 160 °C 1), steam max. 30 min 2)
Seat seal FKM, FFKM
bypass diaphragm material EPDM,
(code 43, F3)
150 °C 3), max. 30 min
Seat seal FKM, FFKM
bypass diaphragm material PTFE/EPDM,
PTFE laminated, (code 45, F5)
150 °C 3), max. 30 min
Seat seal FKM, FFKM
bypass diaphragm material EPDM,
(code 47, F7)
150 °C 3), max. 30 min
Seat seal PTFE
bypass diaphragm material PTFE/EPDM,
PTFE laminated, (code 55)
150 °C 3), max. 30 min
1) The sterilization temperature is only valid for steam (saturated steam) or superheated water.
2) Longer sterilization times or continuous operation on request.
3) If the sterilization temperatures listed above are applied to the EPDM diaphragms for longer periods of time,
the service life of the diaphragms will be reduced. In these cases, maintenance cycles must be adapted ac-
cordingly. This also applies to PTFE diaphragms exposed to high temperature fluctuations. The mainten-
ance cycles must be adapted accordingly.
Ambient temperature: -10 — 60 °C
Storage temperature: 0 — 40 °C
7.3 Pressure
Operating pressure: 0 — 10 bar
Pressure/Temperature diagram
11
10
9
8
7
6
5
4
3
2
1
-20 -10 0 20 40 60 80 100 120 140 160130
Temperature [°C]
Operating pressure [bar]
www.gemu-group.com12 / 60GEMÜ 567 eSyDrive
7 Technical data

Leakage rate: Control valve
Seat seal Standard Test procedure Leakage rate Test medium
FKM, PTFE DIN EN 60534-4 1 VI Air
Kv values:
100
80
60
40
20
100
80604020
0
L
G
0
Kv value [%]
Stroke [%]
Code 17, 60, 82 and 86
AG Seal ma-
terial
code
Control
character-
istic
Kv value DN 8 DN
10
DN
15
DN
20
DN
25
DN
32
DN
40
DN
50
2 4, 43, 45,
47, F, F5
GAA, LAA 80l/h X X X - - - - -
GAB, LAB 100 l/h X X X - - - - -
GBC, LBC 160 l/h X X X - - - - -
GBD, LBD 250 l/h X X X - - - - -
GBE, LBE 400 l/h X X X - - - - -
GCF, LCF 630 l/h X X X - - - - -
GCG, LCG 1.0 m³/h - X X - - - - -
5, 55 GDH, LDH 1.6 m³/h - X X - - - - -
GEJ, LEJ 2.6 m³/h - - X - - - - -
GG1, LG1 4.1 m³/h - - X - - - - -
3 5 GH2, LH2 8.0 m³/h - - - X X - - -
GJ3, LJ3 12.5 m³/h - - - - X - - -
4 5 GK4, LK4 14.0 m³/h - - - - - X X -
GK5, LK5 18.0 m³/h - - - - - X X -
GK6, LK6 25.0 m³/h - - - - - X X -
GM7, LM7 32.0 m³/h - - - - - - X -
GM8, LM8 40.0 m³/h - - - - - - X -
5 5 GN9, LN9 50.0 m³/h - - - - - - - X
GNK, LNK 63.0 m³/h - - - - - - - X
GEMÜ 567 eSyDrivewww.gemu-group.com 13 / 60
7 Technical data

Kv values: Code 59 and 88
AG Seal mater-
ial code
Control
character-
istic
Kv value DN 15 DN 20 DN 25 DN 40 DN 50 DN 65
2 4, 43,
45, 47,
F, F5
GAA, LAA 80l/h X X - - - -
GAB, LAB 100 l/h X X - - - -
GBC, LBC 160 l/h X X - - - -
GBD, LBD 250 l/h X X - - - -
GBE, LBE 400 l/h X X - - - -
GCF, LCF 630 l/h X X - - - -
GCG, LCG 1.0 m³/h X X - - - -
5, 55 GDH, LDH 1.6 m³/h X X - - - -
GEJ, LEJ 2.6 m³/h - X - - - -
GG1, LG1 4.1 m³/h - X - - - -
3 5 GH2, LH2 8.0 m³/h - - X - - -
4 5 GK4, LK4 14.0 m³/h - - - X X -
GK5, LK5 18.0 m³/h - - - X X -
GK6, LK6 25.0 m³/h - - - X X -
GM7, LM7 32.0 m³/h - - - - X -
GM8, LM8 40.0 m³/h - - - - X -
5 5 GN9, LN9 50.0 m³/h - - - - - X
GNK, LNK 63.0 m³/h - - - - - X
Kv values - Bypass (only available in AG2)
Code DN8 DN10 DN15 DN20
0, 17, 86 1.5 m3/h 1.8 m3/h 2.1 m3/h -
60, 82 1.8 m3/h 2.1 m3/h 2.1 m3/h -
59, 88 - - 1.8 m3/h 2.1 m3/h
AG = actuator size
Kv values determined acc.to DIN EN 60534.
www.gemu-group.com14 / 60GEMÜ 567 eSyDrive
7 Technical data

7.4 Product compliance
Pressure Equipment Dir-
ective:
2014/68/EU
Machinery Directive: 2006/42/EC
EMC Directive: 2014/30/EU
Technical standards used:
Interference resistance DIN EN 61000-6-2 (Nov. 2019)
DIN EN 61326-1 (industry)
Interference emission Actuator size 2, 3
DIN EN 61000-6-4
Interference emission class: Class A
Interference emission group: Group 1
Actuator size 4, 5
DIN EN 61800-3
Category: C3
The product is intended for operation in industrial envir-
onments.
Food: Regulation (EC) No. 1935/2004*
Regulation (EC) No. 10/2011*
FDA*
USP* Class VI
* depending on version and/or operating parameters
7.5 Mechanical data
Protection class: IP 65 acc. to EN 60529
Weight: Actuator
Actuator size 2 2.86 kg
Actuator size 3 4.56 kg
Actuator size 4 11.52 kg
Actuator size 5 14.44 kg
Body
Actuator size 2 1.6 kg
Actuator size 3 2.8 kg
Actuator size 4 4.3 kg
Actuator size 5 7.6 kg
Actuating speed: Actuator size 2 adjustable, max. 6 mm/s
Actuator size 3 adjustable, max. 6 mm/s
Actuator size 4 adjustable, max. 4 mm/s
Actuator size 5 adjustable, max. 4 mm/s
7.6 Duty cycle and service life
Service life: Control operation - Class C acc. to EN 15714-2 (1,800,000 start-ups and 1200 start-ups per hour).
Open/Close duty – Minimum 1,000,000 switching cycles at room temperature and permissible duty
cycle.
Duty cycle: Control operation - Class C acc. to EN 15714-2.
Open/Close duty - Continuous duty
GEMÜ 567 eSyDrivewww.gemu-group.com 15 / 60
7 Technical data

7.7 Electrical data
7.7.1 Supply voltage
Actuator size 2 Actuator size 3 Actuator size 4, 5
Voltage Uv = 24 V DC ± 10%
Rating Max. 28 W Max. 65 W Max. 120 W
Reverse battery protection Yes
7.7.2 Analogue input signals
7.7.2.1 Set value
Input signal: 0/4 - 20 mA; 0 – 10 V DC (selectable using software)
Input type: passive
Input resistance: 250 Ω
Accuracy/linearity: ≤ ±0.3% of full flow
Temperature drift: ≤ ±0.1% / 10°K
Resolution: 12 bit
Reverse battery protec-
tion:
No
Overload proof: Yes (up to ± 24 V DC)
7.7.2.2 Process actual value
Input signal: 0/4 - 20 mA; 0 – 10 V DC (selectable using software)
Input type: passive
Input resistance: 250 Ω
Accuracy/linearity: ≤ ±0.3% of full flow
Temperature drift: ≤ ±0.1% / 10°K
Resolution: 12 bit
Reverse battery protec-
tion:
No
Overload proof: Yes (up to ± 24 V DC)
7.7.3 Digital input signals
Digital inputs: 3
Function: selectable using software
Voltage: 24 V DC
Logic level "1": >14 V DC
Logic level "0": < 8 V DC
Input current: typ. 2.5 mA (at 24 V DC)
www.gemu-group.com16 / 60GEMÜ 567 eSyDrive
7 Technical data

7.7.4 Analogue output signals
7.7.4.1 Actual value
Output signal: 0/4 - 20 mA; 0 – 10 V DC (selectable using software)
Output type: Active (AD5412)
Accuracy: ≤ ±1% of full flow
Temperature drift: ≤ ±0.1% / 10°K
Load resistor: ≤ 750 kΩ
Resolution: 10 bit
Overload proof: Yes (up to ± 24 V DC)
Short-circuit proof: Yes
7.7.5 Digital output signals
7.7.5.1 Switching outputs 1 and 2
Design: 2x make contact, potential-free
Switching voltage: max. 48 V DC / 48 V AC
Switch rating: max. 60 W / 2A
Switch points: Adjustable 0 - 100 %
7.7.5.2 Switching output 3
Function: Signal fault
Type of contact: Push-Pull
Switching voltage: Supply voltage
Switching current: ≤ 0.1 A
Drop voltage: Max. 2.5 V DC at 0.1 A
Overload proof: Yes (up to ± 24 V DC)
Short-circuit proof: Yes
Pull-Down resistance: 120 kΩ
7.7.6 Communication eSy-Web
Interface: Ethernet
Function: Parameterisation via web browser
IP address: 192.168.2.1 alterable via web browser
Subnet screen: 255.255.252.0 alterable via web browser
The actuator and the PC must be in the same network to use the web server. The IP address of the actuator is entered in the
web browser and the actuator can then be parametrised. In order to use more than one actuator, a definitive IP address must be
assigned to each actuator in the same network.
GEMÜ 567 eSyDrivewww.gemu-group.com 17 / 60
7 Technical data

7.7.7 Communication Modus TCP
Interface: Modbus TCP
IP address: 192.168.2.1 alterable via web browser
Subnet screen: 255.255.252.0 alterable via web browser
Port: 502
Supported function
codes:
Code Dezimal Code Hex Function
3 0x03 Read Holding Registers
4 0x04 Read Input Registers
6 0x06 Write Single Register
16 0x10 Write Multiple Registers
23 0x17 Read/Write Multiple Registers
7.7.8 Behaviour in the event of an error
Function: In the event of an error the valve moves to the error position.
Notes: Moving to the error position is only possible with full power supply. This behaviour is not a
safety position. The valve must be operated with a GEMÜ 1571 emergency power supply module
(see accessories) to ensure the function in case of voltage loss.
Error position: Closed, open or hold (adjustable via eSy-web web interface).
8 Dimensions
8.1 Actuator dimensions
B1
B2
A1
ØB
CT *
B3
A
DN Actuator
size
A A1 ØB B1 B2 B3
8 - 20 2 263.7 44.0 68.0 126.0 160.0 190.0
www.gemu-group.com18 / 60GEMÜ 567 eSyDrive
8 Dimensions

DN Actuator
size
A A1 ØB B1 B2 B3
20 - 25 3 351.5 83.0 82.0 132.0 172.0 250.0
32 - 50 4 411.5 124.0 134.0 157.0 224.0 296.0
50 - 65 5 433.0 124.0 134.0 157.0 224.0 296.0
Dimensions in mm
* CT = A + H1 (see body dimensions)
8.2 Body dimensions
8.2.1 Spigot without bypass code 0
H2
E
L
c
c
s
d
s
d
LE
H1
CZ
Z
AG DN Connection type code 0 1)
Material code 41 2), 43 2)
Seat
size
(code)
L□E c Øz LE H1 H2 cz Ød s
2 15 A 45.0 75.0 20.0 2.0 44.0 21.0 40.5 6.5 18.0 1.5
B45.0 75.0 20.0 4.0 44.0 21.0 39.5 5.5 18.0 1.5
C45.0 75.0 20.0 6.0 44.0 21.0 38.5 4.5 18.0 1.5
D45.0 75.0 20.0 8.0 44.0 21.0 41.0 3.5 18.0 1.5
E45.0 75.0 20.0 10.0 44.0 21.0 40.0 2.5 18.0 1.5
G45.0 75.0 20.0 15.0 44.0 21.0 37.5 0.0 18.0 1.5
3 20 H 55.0 95.0 25.0 20.0 54.0 26.0 50.0 0.0 22.0 1.5
25 H 55.0 95.0 25.0 20.0 54.0 26.0 50.0 2.5 28.0 1.5
GEMÜ 567 eSyDrivewww.gemu-group.com 19 / 60
8 Dimensions

AG DN Connection type code 0 1)
Material code 41 2), 43 2)
Seat
size
(code)
L□E c Øz LE H1 H2 cz Ød s
J55.0 95.0 25.0 25.0 54.0 26.0 47.5 0.0 28.0 1.5
Dimensions in mm
AG = actuator size
1) Connection type
Code 0: Spigot DIN
2) Valve body material
Code 41: 1.4435 (316L), block material
Code 43: 1.4435 (BN2), block material, Δ Fe < 0.5%
8.2.2 Spigot without bypass code 17
H2
E
L
c
c
s
d
s
d
LE
H1
CZ
Z
AG DN Connection type code 17 1)
Material code 41 2), 43 2)
Seat
size
(code)
L□E c Øz LE H1 H2 cz Ød s
2 8 A 45.0 75.0 20.0 2.0 47.5 17.5 40.5 3.0 10.0 1.0
B45.0 75.0 20.0 4.0 47.5 17.5 39.5 2.0 10.0 1.0
C45.0 75.0 20.0 6.0 47.5 17.5 38.5 1.0 10.0 1.0
10 A 45.0 75.0 20.0 2.0 46.5 18.5 41.5 4.0 13.0 1.5
B45.0 75.0 20.0 4.0 46.5 18.5 40.5 3.0 13.0 1.5
C45.0 75.0 20.0 6.0 46.5 18.5 39.5 2.0 13.0 1.5
D45.0 75.0 20.0 8.0 46.5 18.5 38.5 1.0 13.0 1.5
15 A 45.0 75.0 20.0 2.0 43.5 21.5 44.5 7.0 19.0 1.5
B45.0 75.0 20.0 4.0 43.5 21.5 43.5 6.0 19.0 1.5
C45.0 75.0 20.0 6.0 43.5 21.5 42.5 5.0 19.0 1.5
www.gemu-group.com20 / 60GEMÜ 567 eSyDrive
8 Dimensions
Table of contents
Other GEM Control Unit manuals