manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Gira
  6. •
  7. Accessories
  8. •
  9. Gira GEDU 10 Guide

Gira GEDU 10 Guide

This manual suits for next models

5

Other Gira Accessories manuals

Gira 5142 00 Operator's manual

Gira

Gira 5142 00 Operator's manual

Gira 0873 00 User manual

Gira

Gira 0873 00 User manual

Gira 5068 00 User manual

Gira

Gira 5068 00 User manual

Gira 5471 00 User manual

Gira

Gira 5471 00 User manual

Gira 5466 02 User manual

Gira

Gira 5466 02 User manual

Gira 5111 00 User manual

Gira

Gira 5111 00 User manual

Gira 5472 02 User manual

Gira

Gira 5472 02 User manual

Gira EDA 3902 F User manual

Gira

Gira EDA 3902 F User manual

Gira Observer 110 User manual

Gira

Gira Observer 110 User manual

Gira 5112 00 Operator's manual

Gira

Gira 5112 00 Operator's manual

Gira KNX/EIB User manual

Gira

Gira KNX/EIB User manual

Gira 1025 00 User manual

Gira

Gira 1025 00 User manual

Gira KNX 5011 00 User manual

Gira

Gira KNX 5011 00 User manual

Gira 1493 00 User manual

Gira

Gira 1493 00 User manual

Gira 5461 02 User manual

Gira

Gira 5461 02 User manual

Gira 0551 4 Series User manual

Gira

Gira 0551 4 Series User manual

Gira 5472 02 User manual

Gira

Gira 5472 02 User manual

Gira CO2-Sensor User manual

Gira

Gira CO2-Sensor User manual

Gira System 55 Pushbutton sensor 4 Standard User manual

Gira

Gira System 55 Pushbutton sensor 4 Standard User manual

Gira 1117 00 User manual

Gira

Gira 1117 00 User manual

Gira Touch sensor 2 User manual

Gira

Gira Touch sensor 2 User manual

Gira 1170 Series User manual

Gira

Gira 1170 Series User manual

Gira 234902 User manual

Gira

Gira 234902 User manual

Gira 5069 00 User manual

Gira

Gira 5069 00 User manual

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

GIRA
Info Antenna outlet socket GEDU 10 / 15 / 20
Instructions for Installation
Antenna outlet socket GEDU 10 / 15 / 20 04/98 Page 1 of 4
Antenna outlet socket GEDU 10 Art. Nr.: 0041 00
Antenna outlet socket GEDU 15 Art. Nr.: 0042 00
Antenna outlet socket GEDU 20 Art. Nr.: 0927 00
Description
For community antenna systems, CATV and SAT systems.
Two equivalent outputs (socket and plug) acc. to IEC 169-2 (DIN 45 325).
Any connection of radio receivers, TV-sets and SAT-receivers is possible.
Meets the specification 1 R 8-15 and the drafts DIN V VDE 0855.
Shielding rate
up to 470 MHz ≥75 dB
470 - 1000 MHz ≥65 dB
1000 - 2400 MHz ≥55 dB
Suitable as loop-wired and terminal socket (see Fig. 7, page 4).
Simplified connecting and easy mounting of the coaxial cables by clamp opened lateral.
For connecting of mini coax cables and coax cables with outer conductor diameter up to 5.5 mm.
Mounting
12cm
20cm
15 82
Fig.: 1
1. The antenna outlet sockets can be installed in flush
mounting boxes of 58 mm Ø.
Provide the coaxial cables with a reserve of approx.
12 and 20 cm inside the flush mounting box.
Strip the cable ends (Fig. 1).
1
2
K
Fig.: 2
2. Open the clamp K entirely by passing position cup to
position d. In position dK is arrested.
(Fig. 2).
GIRA
Info Antenna outlet socket GEDU 10 / 15 / 20
Instructions for Installation
Antenna outlet socket GEDU 10 / 15 / 20 04/98 Page 2 of 4
Fig.: 3
3. Install the coaxial cables acc. to Fig. 3.
S
Fig.: 4
4. Loosen the contact screws S far enough for putting-in
the centre conductor between white and black plastic
part (Fig. 4).
Fig.: 5
5. Fix the centre conductors with the contact screws S (Fig.
5).
Close the clamp K and fasten.
Fig.: 6
6. Insert the antenna outlet socket into the flush mounting
box and fix with the two expanding claws Sk (Fig. 6).
7. Completely assemble the antenna outlet socket.
GIRA
Info Antenna outlet socket GEDU 10 / 15 / 20
Instructions for Installation
Antenna outlet socket GEDU 10 / 15 / 20 04/98 Page 3 of 4
Examples of application
Optimal cascading Standard
GEDU 10
GEDU 10
GEDU 15
GEDU 15
GEDU 15
GEDU 20
GEDU 20
GEDU 20 GEDU 20
GEDU 20
GEDU 20
GEDU 15
GEDU 15
GEDU 15
GEDU 10
GEDU 10
GEDU 15
GEDU 15
GEDU 15
GEDU 15
GEDU 15
GEDU 15
GEDU 15
GEDU 15
Technical data
Frequency range f / MHz AM / RC1)
4-30
VHF I-III / SC2)
47-470
UHF IV / V
470-862
SAT
950-2050
SAT
2050-2400
Throughpass attenuation GEDU 10
GEDU 15
GEDU 20
dB
dB
dB
2,8
1,0
0,8
2,2
0,8
0,6
2,4
0,8
0,8
3,2
1,4
1,1
4,2
1,8
1,4
Output attenuation GEDU 10
GEDU 15
GEDU 20
dB
dB
dB
11,5
14,5
20
10
14,5
20
10
14,5
20
10
15
20,5
11,5
15,5
21
Directional attenuation GEDU 10
GEDU 15
GEDU 20
dB
dB
dB
35
30
40
40
40
44
36
40
40
22
30
30
20
26
30
Decoupling internal GEDU 10
GEDU 15
GEDU 20
dB
dB
dB
40
18
18
42
24
24
38
24
24
32
24
22
30
24
20
Decoupling between 2 sockets GEDU 10
GEDU 15
GEDU 20
dB
dB
dB
40
44
60
50
54
64
46
54
60
32
44
50
32
42
50
1) RC = Reverse channel range 2) SC= Special channels
GIRA
Info Antenna outlet socket GEDU 10 / 15 / 20
Instructions for Installation
Antenna outlet socket GEDU 10 / 15 / 20 04/98 Page 4 of 4
Fig.: 7
Loop-wired socket
When connecting incoming and outgoing trunk lines please
consider the direction marking arrows.
Fig.: 8
When used as a terminal socket (last socket in trunk line),
the terminal resistor R 77 (Gira - Bestell-Nr.: 040 00) is to be
connected in the place of an outgoing cable.
Acceptance of guarantee
We accept the guarantee in accordance with the corresponding legal provisions.
Please return the unit postage paid to our central service department giving a brief description
of the fault:
Gira
Giersiepen GmbH & Co. KG
Service Center
Dahlienstrasse 12
D-42477 Radevormwald
The CE sign is a free trade sign addressed exclusively to the authorities and does not include
any warranty of any properties.
Gira
Giersiepen GmbH & Co. KG
Postfach 1220
D-42461 Radevormwald
Telefon: +49 / 21 95 / 602 - 0
Telefax: +49 / 21 95 / 602 - 339
Internet: www.gira.de