manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lamp
  6. •
  7. Door Opening System
  8. •
  9. Lamp AZ-AT230-HL Instruction Manual

Lamp AZ-AT230-HL Instruction Manual

This manual suits for next models

1

Other Lamp Door Opening System manuals

Lamp HDSN-30K User manual

Lamp

Lamp HDSN-30K User manual

Lamp FD35EV User manual

Lamp

Lamp FD35EV User manual

Lamp FM150PRO User manual

Lamp

Lamp FM150PRO User manual

Lamp HC-30L User manual

Lamp

Lamp HC-30L User manual

Lamp SLUN-N User manual

Lamp

Lamp SLUN-N User manual

Lamp FD30EX User manual

Lamp

Lamp FD30EX User manual

Lamp FD80-H User manual

Lamp

Lamp FD80-H User manual

Lamp FD30-F User manual

Lamp

Lamp FD30-F User manual

Lamp FD50-H User manual

Lamp

Lamp FD50-H User manual

Lamp FD50-H User manual

Lamp

Lamp FD50-H User manual

Lamp FD30EX User manual

Lamp

Lamp FD30EX User manual

Lamp FD50-H User manual

Lamp

Lamp FD50-H User manual

Lamp KF28 User manual

Lamp

Lamp KF28 User manual

Lamp AZ-GD231 User manual

Lamp

Lamp AZ-GD231 User manual

Lamp FD35EV User manual

Lamp

Lamp FD35EV User manual

Lamp FD30-F User manual

Lamp

Lamp FD30-F User manual

Lamp FD50-H User manual

Lamp

Lamp FD50-H User manual

Lamp KF111-H User manual

Lamp

Lamp KF111-H User manual

Lamp HCZ-80 User manual

Lamp

Lamp HCZ-80 User manual

Lamp XL-GC07D-CR User manual

Lamp

Lamp XL-GC07D-CR User manual

Lamp LDD-S User manual

Lamp

Lamp LDD-S User manual

Lamp MonoFlat FAD-5 User manual

Lamp

Lamp MonoFlat FAD-5 User manual

Lamp FD35EV User manual

Lamp

Lamp FD35EV User manual

Lamp FD80-AFH User manual

Lamp

Lamp FD80-AFH User manual

Popular Door Opening System manuals by other brands

Mobeye Call-Key MCK100 installation manual

Mobeye

Mobeye Call-Key MCK100 installation manual

SALICE Lapis Assembly instructions

SALICE

SALICE Lapis Assembly instructions

Cal-Royal N-F77CVR Installation instruction

Cal-Royal

Cal-Royal N-F77CVR Installation instruction

Scrigno OPEN1000 Assembly manual

Scrigno

Scrigno OPEN1000 Assembly manual

BFT WIND RMB 130B 200 installation manual

BFT

BFT WIND RMB 130B 200 installation manual

Alecto ADI-250 user manual

Alecto

Alecto ADI-250 user manual

Besam Swingmaster MP Installation, adjustment and maintenance instructions

Besam

Besam Swingmaster MP Installation, adjustment and maintenance instructions

Assa Abloy SARGENT 1431 Series instructions

Assa Abloy

Assa Abloy SARGENT 1431 Series instructions

GAL MOVFR Quick setup

GAL

GAL MOVFR Quick setup

Häfele Finetta T 70 VF manual

Häfele

Häfele Finetta T 70 VF manual

AGS D-PL Instructions for fitting, operating and maintenance

AGS

AGS D-PL Instructions for fitting, operating and maintenance

Stanley MA900ñ Installation and owner's manual

Stanley

Stanley MA900ñ Installation and owner's manual

WITTUR Hydra Plus UD300 Instruction handbook

WITTUR

WITTUR Hydra Plus UD300 Instruction handbook

Alutech TR-3019-230E-ICU Assembly and operation manual

Alutech

Alutech TR-3019-230E-ICU Assembly and operation manual

Pamex KT-INP35 Installation instruction

Pamex

Pamex KT-INP35 Installation instruction

MPC ATD ACTUATOR 50 ATD-313186 Operating and OPERATING AND INSTALLATION Manual

MPC

MPC ATD ACTUATOR 50 ATD-313186 Operating and OPERATING AND INSTALLATION Manual

Chamberlain T user guide

Chamberlain

Chamberlain T user guide

Dorma MUTO COMFORT M DORMOTION 50 Mounting instruction

Dorma

Dorma MUTO COMFORT M DORMOTION 50 Mounting instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
TOUCHLESS MULTI-PURPOSE LID AZ-AT
Installation instructions
PARTS DESCRIPTION
DIMENSION DRAWING
Thank you for using our product. Before installation, please read this manual
thoroughly to ensure correct installation.
Please keep this manual at hand for future reference.
Description Quantity
Flap lid body 1
Sticker (warning) 1
Sticker(Open) 1
Wiringclips 3
Cover cap 4
Screw jig 1
●The lid opens automatically when the sensor detects a presence.
●The sensing distance of the sensor can be adjusted from 0 to 300 mm by
adjusting the knob on the back.
TOOLS NEEDED FOR INSTALLATION
FOR YOUR SAFETY AND CORRECT INSTALLATION
ABOUT THE PRODUCT
Item No A B W H C P D
AZ-AT230-HL 234 160 319 266.5 49 95 184.7
AZ-AT310-HL 310 220 395 340 64 140 244.7
CUTOUT DIMENSIONS
●AC Adaptor (sold separately)
●Screws (not provided)
Choose the suitable length according to the material to be mounted.
Recommended screw : Tapping screw Nominal 3 ・・・・ ・4 pcs
A
10
100
Auto-opening
angle: 80゚
C P
4×
I3.5holes
for fixing screws
when flap at 90°(D)
W
H
B
382.4
+1
0
4×R6
Max.
324
+1
0
140
54
147.5
4×R6
Max.
248.5
+1
0
142
9539
Mounting
screw holes
AZ-AT230-HL
AZ-AT310-HL
153.2
+0.5
0
132.5
+0.5
0
Mounting
screw holes
Cut out: Backside view
Cut out: Backside view
45°
0°
300
Front
Side
200
200
45°
300
25°
15°
Sensing range
Caution:If not followed, injury or damage may result.
This product is designed to function when installed vertically as shown below. Horizontal, slanted or upside down installation will result in improper
function and may lead to injury.
To avoid any risk of accidental injury, ensure that the product is securely fastened to a support with adequate strength.
Do not use this product for any purpose that is outside of the specifications of this manual.
Do not use outside or anywhere it will be exposed to water. It may cause failure.
Do not use in places where strong radio waves are generated. It may cause malfunction.
Ambient temperature range is 0 to 40゚C
The closing speed of the lid may vary according to ambient temperature. If the product is stored below zero degrees allow it to reach room
temperature before use.
Due to the characteristics of the sensor, the sensing distance varies depending on the object.
Prohibited
Warning
Caution Required
Meaning of symbols
2
❶Insert the plug of the
AC adapter here.
❸Adjust the sensing distance with this knob
Clockwise: Increase up to 300 mm
Anti-clockwise: Decrease to 0 mm (No sensing)
❹Use the wiring clips so that the wire does not interfere
with the contents of the waste container.
Recommended screw: Pan head tapping screw I3
❷Hold your hand
over the sensor.
Cover cap
Installation procedure
 Mounting of Main Body
1
2Wiring and Adjustment of Sensing Distance
4Pasting the stickers
3Putting on the Cover Caps
5Troubleshooting
6In case of power outage
The lid can be opened manually just like a normal lid system. The soft close is available.
Trouble Solution
No sensing
※1
Make sure that the plug of the AC adapter is connected correctly.
If there is an object in the sensing range of the sensor, move it.
Adjust the sensing distance with the knob ( 󱳝-❸).
Too sensitive
※1
Adjust the sensing distance with the knob ( 󱳝-❸).
LED lights red Check that no objects in the front or back of the lid are clogged with
dust.
Lid doesn't
close fully
Make sure that there is no dust caught in the lid. If that doesn't
ZRUNWXUQWKHSRZHURႇDQGWKHQRQDJDLQ
Lid doesn't
open fully
Check that the back of the lid is not clogged with dust and that
cables are not entangled.
Waste container
❶Fit the main
body to the hole.
❷Insert the screw jig. ❸Fasten with tapping
screw I3 (not provided).
❹Remove the jig.
SUGATSUNE KOGYO CO.,LTD  
Tokyo, JAPAN
Phone: +81 (0)3 3866 2260 E-mail:[email protected]
SUGATSUNE KOGYO (UK) LTD  
Reading, UK
Phone: +44 118 9272 955
 
E-mail:[email protected]
SUGATSUNE EUROPE GmbH  
Dusseldorf, GERMANY
Phone: +49 211 53812900
 
E-mail:[email protected]
SUGATSUNE SHANGHAI Co., LTD  
Shanghai, CHINA
Phone: +86 21 3632 1858  E-mail:[email protected]
Guangzhou, CHINA  
Phone: +86 20 6639 3552  E-mail:[email protected]
SUGATSUNE KOGYO INDIA PRIVATE LIMITED  
Mumbai, INDIA
Phone: +91 22 28314490/91 E-mail:[email protected]
SUGATSUNE AMERICA, INC  
California, USA
Phone: +1 310 329 6373 E-mail:[email protected]
Chicago, USA  
Phone: +1 312 461 1081
E-mail:[email protected].
SUGATSUNE CANADA, INC.  
Phone: +1 514 312 5267
E-mail:[email protected]
2021.10 1447-3
Near the sensor
Conspicuous
place on the
entire front lid or
the main body
with waste
※1

'XHWRWKHQDWXUHRIWKHVHQVRUOLJKWUHÀHFWLYHREMHFWVEULJKWFRORXUVRUVKLQ\REMHFWV
ZLOOLQFUHDVHWKHVHQVLQJGLVWDQFHZKHUHDVREMHFWVZKLFKDUHQRWUHÀHFWLYHGDUNFRORXUV
or non-shiny objects) will decrease the sensing distance.