Nibe SMS 40 User guide

LEK
SMS 40
Installatörshandbok Kommunikationsmodul
för NIBEF1145,F1155,F1245,F1255,F1345, F370,
F470, F750, VVM 310, VVM 320, VVM 325,
VVM 500, SMO 40
SE
Installer manual Communications module
for NIBEF1145,F1155,F1245,F1255,F1345, F370,
F470, F750, VVM 310, VVM 320, VVM 325,
VVM 500, SMO 40
GB
Installateurhandbuch Kommunikationsmodul
fürNIBEF1145,F1155,F1245,F1255,F1345, F370,
F470, F750, VVM 310, VVM 320, VVM 325,
VVM 500, SMO 40
DE
Asentajan käsikirja Tiedonsiirtomoduuli
laitteille NIBEF1145,F1155,F1245,F1255,F1345,
F370, F470, F750, VVM 310, VVM 320, VVM 325,
VVM 500, SMO 40
FI
Manuel installateur Module de communication
NIBE F1145, F1155, F1245, F1255, F1345, F370,
F470, F750, VVM 310, VVM 320, VVM 325,
VVM 500, SMO 40
FR
031502
IHB 1449-6


Allmänt
Med SMS 40 kan du styra och övervaka din NIBE värme-
pump/inomhusmodul med en mobiltelefon via SMS-
meddelande. För att detta ska fungera måste SMS 40
förses med ett giltigt GSM-abonnemang.
Telefonen som används måste vara utrustad med stöd
för 2G. Kontantkort eller vanliga abonnemang fungerar
lika bra. Dock måste kontantkort fyllas på med jämna
mellanrum för att inte avaktiveras.
OBS!
Kontrollera att det går att skicka SMS med SIM-
kortet som ska användas.
Avaktivera ev. PIN-kod för SIM-kortet. Detta
kan göras i en mobiltelefon eller hos din leve-
rantör av abonnemang.
Innehåll
Apparatlåda1 st
Antenn (2,5 m)1 st
Väggfäste1 st
TÄNK PÅ!
Värmepumpens/inomhusmodulens program-
vara ska vara av senast rekommenderade ver-
sion eller ha versionsnummer högre än 3000.
Om inte, ladda ned senast rekommenderade
mjukvaruversion för er produkt till ett
USB-minne från http://www.nibeuplink.com
och installera denna.
Montering
SMS 40 kan placeras liggande på en plan yta eller
hängas på vägg. I de fall SMS 40 hängs på vägg an-
vänds det bipackade väggfästet.
LEK
LEK
OBS!
Vid väggmontage ska hålet för antennkabeln
vara riktat neråt för att förhindra att vatten
kommer in i SMS 40.
OBS!
SMS 40 ska inte monteras utomhus.
SMS 40 levereras med en antenn färdigmonterad från
fabrik. Antenndelen har en bit självhäftande tejp, som
kan användas till att fästa antennen på exempelvis ett
fönster om täckningen på installationsplatsen är dålig.
3
Svenska, Installatörshandbok - SMS 40
SE

Elinkoppling
OBS!
All elektrisk inkoppling skall ske av behörig
elektriker.
Elektrisk installation och ledningsdragning
skall utföras enligt gällande bestämmelser.
Värmepumpen/inomhusmodulen ska vara
spänningslös vid installation av SMS 40.
Anslutning av kommunikation
SMS 40
AA9-X1
Elschema finns i slutet av denna monteringsanvisning.
Bergvärmepumpar
Plint X1 på SMS-kortet (AA9) i SMS 40 ansluts till plint
X4:9-12 på ingångskortet (AA3) i värmepumpen/inom-
husmodulen.
Använd kabeltyp LiYY, EKKX eller likvärdig.
F1145/F1155
12V A B GND
12
1110987
AA3-X4
SMS40
F1145/F1155
AA9-X1
AA3-X4
F1245/F1255
12V A B GND
12
1110987
AA3-X4
AA9-X1
F1245/F1255
SMS40
AA3-X4
F1345
Plint X1 på SMS-kortet (AA9) i SMS 40 ansluts till plint
X6:4-7 i värmepumpen.
Använd kabeltyp LiYY, EKKX eller likvärdig.
6 74 5
F1345
Externt
12V A B GND
X6
SMS40
F1345
AA9-X1
LEK
X6
4
SE

Frånluftsvärmepumpar
Plint X1 på SMS-kortet (AA9) i SMS 40 ansluts till plint
X4:9-12 på ingångskortet (AA3) i värmepumpen/inom-
husmodulen.
Använd kabeltyp LiYY, EKKX eller likvärdig.
F370 / F470
12V A B GND
12
1110987
F370/F470
AA3-X4
AA9-X1
SMS40
AA3-X4
F750
12V A B GND
12
1110987
SMS40
F750
AA3-X4
AA9-X1
LEK
AA3-X4
Luft/vattenvärmepumpar
Inomhusmoduler
Plint X1 på SMS-kortet (AA9) i SMS 40 ansluts till plint
X4:9-12 på ingångskortet (AA3) i värmepumpen/inom-
husmodulen.
Använd kabeltyp LiYY, EKKX eller likvärdig.
VVM 310
12V A B GND
12
1110987
VVM 310
AA3-X4
AA9-X1
SMS40
Wilo
Wilo
VVM310
AA3-X4
VVM 320
12V A B GND
12
1110987
VVM 320
AA3-X4
AA9-X1
SMS40
VVM320
AA3-X4
VVM 325
12V A B GND
12
1110987
VVM 325
AA3-X4
AA9-X1
SMS40
AA3-X4
VVM325 VVM325
VVM 500
12V A B GND
12
1110987
VVM 500
AA3-X4
AA9-X1
SMS40
APH
VVM500
AA3-X4
5
SE

Styrmodul SMO 40
SMS 40 ansluts till ingångskortet (AA3) på SMO 40.
Använd kabeltyp LiYY, EKKX eller likvärdig.
12V A B GND
12
1110987
SMO40
AA3-X4
AA9-X1
SMS40
L N 1 1 0 2 3 4PE
1 2 3 4
LEK
AA3-X4
Flera tillbehör tillsammans med SMS 40
Ifall SMS 40 ska anslutas tillsammans med MODBUS 40,
måste MODBUS 40 vara första enheten inkopplad till
värmepumpen/inomhusmodulens anslutningsplint.
Inkoppling till och från SMS 40/MODBUS 40 sker i plint
AA9:X1.
Det går inte att koppla in fler än två enheter till värme-
pumpen/inomhusmodulen.
Värmepump/
Inomhusmodul
MODBUS 40/
SMS 40
Tillbehör2
Tillbehör_singular = translation hint, 2 =
value
SMS 40
SMS 40
B
A
+12V
GND
B
A
+12V
GND
Tillbehör2
Tillbehör1 Värmepump/Inomhusmodul
Tillbehör_singular = translation hint, 1&2 =
value
6
SE

Inställningar
LEK
Plats för SIM-
kort
Plats för batteri
Plats för SIM-kort
Montering av SIM-kort:
1. Skjut försiktigt hållaren åt sidan.
2. Fäll upp hållaren, placera sedan SIM-kortet i korthål-
larens lock.
Om du vill att SMS 40 ska kunna skicka SMS vid strömav-
brott ska du:
■Montera ett 9V batteri på kretskortet i SMS 40.
■Placera bygeln enligt bild nedan.
Bygel
Flyttas
TÄNK PÅ!
PIN-koden måste vara avaktiverad och om det
är ett kontantkort måste det finnas pengar på
kortet.
7
SE

Snabbstartguide
Programinställningen av SMS 40 kan göras via startgui-
den eller direkt i menysystemet.
1. Starta värmepumpen/inomhusmodulen och välj
SMS 40 i meny 5.2 "systeminställningar" (meny
5.2.4 "tillbehör" för NIBE F1345, VVM 310,
VVM 320, VVM 325 och VVM 500).
2. Gå till meny 4.1.4 i din värmepump/inomhusmodul
(meny 5.3.5 om din värmepump/inomhusmodul
har mjukvaruversion 2041 eller tidigare) och lägg
till de mobilnummer som ska ha tillgång till att
ändra och få status från värmepumpen/inomhus-
modulen. Mobilnummer ska vara med landskod
t.ex. +46XXXXXXXX.
3. Om du önskar få ett SMS-meddelande vid larm
bockar du i rutan till höger om telefonnumret.
sms 4.1.4
telefonnummer larmmottagare
OBS!
Angivna telefonnummer måste kunna ta emot
SMS-meddelande.
Ladda hem appen
Har mobiltelefonen operativsystemet Android går det
att använda den mobila applikationen ”NIBE Mobile
App”. Vid larm kan SMS 40 skicka SMS till inprogram-
merade mottagare och presentera det grafiskt.
1. Gå in på Android Market
2. Sök på NIBE Mobile App
3. Ladda hem
Eller scanna in qr-koden nedan med din Android-tele-
fon.
(kräver en scanner-programvara i telefonen).
8
SE

Kontakt med SMS 40
SMS-kommando
SMS 40 skickar ett SMS vid strömavbrott, när värmepumpen/inomhusmodulen startar efter ett strömavbrott samt
vid bestående larm. Dessa meddelanden skickas endast till larmmottagare (meny 4.1.4, meny 5.3.5 om din värme-
pump/inomhusmodul har mjukvaruversion 2041 eller tidigare).
TÄNK PÅ!
Kommandon som skickas till/från SMS 40 ska alltid skrivas som ett ord, t.ex "?solar".
SMS 40 kan ta emot och skicka följande kommandon till värmepumpen/inomhusmodulen:
BeskrivningSvarKommando
Driftlägedrift: auto/endast tillsats?status
Temperatur (förskjutning av värmekurva i system utan rumsgivare)reg1: -10-+10
Temperatur (förskjutning av värmekurva i system utan rumsgivare),
klimatsystem 21)
reg2: -10-+10
Temperatur (förskjutning av värmekurva i system utan rumsgivare),
klimatsystem 31)
reg3: -10-+10
Temperatur (förskjutning av värmekurva i system utan rumsgivare),
klimatsystem 41)
reg4: -10-+10
Temperatur (inställning av rumstemperatur i system med rumsgiva-
re)
rumst1: 5-30
Temperatur (inställning av rumstemperatur i system med rumsgiva-
re), klimatsystem 21)
rumst2: 5-30
Temperatur (inställning av rumstemperatur i system med rumsgiva-
re), klimatsystem 31)
rumst3: 5-30
Temperatur (inställning av rumstemperatur i system med rumsgiva-
re), klimatsystem 41)
rumst4: 5-30
Tillfällig lyx (varmvatten)tlvv: till/från
Fläkthastighet. 0=normal fläkthastighet2), 3+1), 4+1)
vent: 0/1/2/3/4
Semesterinställningsem: till/från
Kompressorstatus2), 3)
status: kör/från?komp
Antal kompressorstarter2), 3)
antal starter: nn
Total drifttid, kompressor och elpatron?2), 3)
total drifttid: nn
Total drifttid, varmvatten2), 3)
- av vilken varmvatten: nn
Kompressorstatus per kylmodul (EP14 respektive EP15)4)
status: kör/från?kompm/?komps1
– ?komps8 Kompressorstatus per utedel (EB10X)7)
Antal kompressorstarter per kylmodul (EP14 respektive EP15)4), 7)
antal starter: nn
Total drifttid, kompressor per kylmodul (EP14 respektive EP15)4), 7)
total drifttid: nn
Total drifttid, varmvatten per kylmodul (EP14 respektive EP15)4), 7)
- av vilken varmvatten: nn
Antal kompressorer som producerar värme4), 7)
värme: nn?akomp
Antal kompressorer som laddar varmvatten4), 7)
varmvatten: nn
Antal kompressorer som laddar pool 14+1), 7+1)
pool: nn
Antal kompressorer som laddar pool 24+1), 7+1)
pool 2: nn
Framledningstemperaturfram: nn?temp
Returledningstemperaturretur: nn
Utomhustemperaturute: nn
Inomhustemperatur. Om rumsgivaren inte är installerad/aktiverad
visas -
inne: nn
Beräknad framledningstemperaturberfram:nn
GradminuterGM: nn
Inkommande köldbärartemperatur3), 4)
KBin: nn
9
SE

Utgående köldbärartemperatur3), 4)
KBut: nn
Varmvattentemperaturvv: nn
Status på laddpump för sol-tillbehör1)
pump: kör/från?solar
Solfångartemperatur1)
BT53: nn
Soltanktemperatur, slinga1)
BT54: nn
Soltanktemperatur, topp2+1)
BT55: nn
Status på tillsatsenstatus: blockerad/från/nn kW2),
3), 5)/ nn (antal steg)4)
?ts
Tidfaktor på tillsatsen2), 3), 4), 5), 7)
tidfaktor: nn
Total drifttid, varmvatten6)
- av vilken varmvatten: nn
BeskrivningSvarParameterKommando
Ändra driftläge?status0/1!drift
Auto/endast tillsats
Tillfällig lyx, varmvatten. 0/3/6/12 timmar.?status0/3/6/12!tlvv
Temperatur (förskjutning av värmekurva i system utan
rumsgivare)
?status-10-+10!reg1
Temperatur (förskjutning av värmekurva i system utan
rumsgivare), klimatsystem 21)
?status-10-+10!reg2
Temperatur (förskjutning av värmekurva i system utan
rumsgivare), klimatsystem 31)
?status-10-+10!reg3
Temperatur (förskjutning av värmekurva i system utan
rumsgivare), klimatsystem 41)
?status-10-+10!reg4
Temperatur (inställning av rumstemperatur i system med
rumsgivare)
?status5-30!rumst1
Temperatur (inställning av rumstemperatur i system med
rumsgivare), klimatsystem 21)
?status5-30!rumst2
Temperatur (inställning av rumstemperatur i system med
rumsgivare), klimatsystem 31)
?status5-30!rumst3
Temperatur (inställning av rumstemperatur i system med
rumsgivare), klimatsystem 41)
?status5-30!rumst4
aktivering/avaktivering av semesterinställning?status1/0!sem
Återställer larm!larm
Ändra fläkthastighet. 0=normal fläkthastighet2), 3+1), 4+1)
0/1/2/3/4!vent
1) Tillbehör krävs
2) Gäller F370, F470 och F750
3) Gäller F1145/F1155 och F1245/F1255
4) Gäller F1345
5) Gäller VVM 310, VVM 320, VVM 325 och VVM 500
6) Gäller F750
7) Gäller SMO40
Exempel
För att kontrollera vilket driftläge som är valt skickas SMS-meddelandet: ?status
För att aktivera "Tillfällig lyx, varmvatten" i 12 timmar skickas SMS-meddelandet: !tlvv 12
Dessa båda kommandon besvaras med ett statusmeddelande.
10
SE

Felsökning
SMS 40 har inte kontakt med GSM-nätet
SMS 40 svarar inte på SMS-kommandon och en symbol
för saknad kontakt med GSM-nätet syns i värmepum-
pens/innemodulens meny 4.1.4 (meny 5.3.5 om din
värmepump/innemodul har mjukvaruversion 2041 eller
tidigare).
sms 4.1.4
telefonnummer larmmottagare
■Kontrollera att SIM-kortet är korrekt monterat.
■Flytta antennen till en bättre plats.
■Kontrollera att PIN-koden är avaktiverad
SMS 40 har inte kontakt med värmepum-
pen/innemodulen
■Larm i värmepumpens/innemodulens display.
■Se avsnitt Komfortstörning i manualen för värme-
pumpen/innemodulen.
■Felaktigt anslutna kablar mellan SMS 40 och värme-
pump/innemodul.
Inget svar på SMS-meddelande
■Telefonnumret är inte registrerat i värmepumpens/in-
nemodulens meny 4.1.4 (meny 5.3.5 om din värme-
pump/innemodul har mjukvaruversion 2041 eller ti-
digare).
Tekniska uppgifter
Tekniska data
12 VDC 45-80 mAMärkspänning
850/900/1800/1900(MHz)GSM
625 06 77RSK nr
067 073Art nr
108 x 154 x 39(mm)Mått
11
SE

General
With SMS 40 you can control and monitor your NIBE
heat pump/indoor module using a mobile telephone
via SMS messaging. For this to work, SMS 40 must be
equipped with a valid GSM subscription.
The telephone used must support 2G. A pay as you go
card or a normal subscription work equally well. How-
ever a pay as you go card must be regularly refilled to
ensure continued use.
NOTE
Check that SMSs can be sent with the SIM card
to be used.
Deactivate if necessary. PIN for SIM card. This
can be done in a mobile telephone or by your
service provider.
Contents
Unit box1 x
Antenna (2,5 m)1 x
Wall bracket1 x
Caution
The heat pump/indoor module software must
be the most recently recommended version
or have a version number higher than 3000.
If not, download the latest recommended
software version for your product to a USB
memory from http://www.nibeuplink.com
and install it.
Mounting
SMS 40 can be positioned lying on a flat surface or wall-
mounted. Where SMS 40 is wall-mounted, use the
supplied wall bracket.
LEK
LEK
NOTE
When wall mounting, the hole for the antenna
cable must be pointing downwards to prevent
water from entering SMS 40.
NOTE
SMS 40 must not be installed outdoors.
SMS 40 is supplied with a factory installed antenna.
The antenna section has a piece of self-adhesive tape
that can be used to secure the antenna, for example
to a window if coverage in the installation location is
poor.
12
English, Installer manual - SMS 40
GB

Electrical connection
NOTE
All electrical connections must be carried out
by an authorised electrician.
Electrical installation and wiring must be car-
ried out in accordance with the stipulations in
force.
The heat pump/indoor module must not be
powered when installing SMS 40.
Connecting communication
SMS 40
AA9-X1
The wiring diagram is at the end of these installation
instructions.
Ground-source heat pumps
Terminal block X1 on the SMS card (AA9) in SMS 40 is
connected to terminal block X4:9-12 on the input card
(AA3) in the heat pump/indoor module.
Use cable type LiYY, EKKX or similar.
F1145/F1155
12V A B GND
12
1110987
AA3-X4
SMS40
F1145/F1155
AA9-X1
AA3-X4
F1245/F1255
12V A B GND
12
1110987
AA3-X4
AA9-X1
F1245/F1255
SMS40
AA3-X4
F1345
Terminal block X1 on the SMS card (AA9) in SMS 40 is
connected to terminal block X6:4-7 in the heat pump.
Use cable type LiYY, EKKX or similar.
6 74 5
F1345
Externt
12V A B GND
X6
SMS40
F1345
AA9-X1
LEK
X6
13
GB

Exhaust air heat pumps
Terminal block X1 on the SMS card (AA9) in SMS 40 is
connected to terminal block X4:9-12 on the input card
(AA3) in the heat pump/indoor module.
Use cable type LiYY, EKKX or similar.
F370 / F470
12V A B GND
12
1110987
F370/F470
AA3-X4
AA9-X1
SMS40
AA3-X4
F750
12V A B GND
12
1110987
SMS40
F750
AA3-X4
AA9-X1
LEK
AA3-X4
Air/water heat pumps
Indoor modules
Terminal block X1 on the SMS card (AA9) in SMS 40 is
connected to terminal block X4:9-12 on the input card
(AA3) in the heat pump/indoor module.
Use cable type LiYY, EKKX or similar.
VVM 310
12V A B GND
12
1110987
VVM 310
AA3-X4
AA9-X1
SMS40
Wilo
Wilo
VVM310
AA3-X4
VVM 320
12V A B GND
12
1110987
VVM 320
AA3-X4
AA9-X1
SMS40
VVM320
AA3-X4
VVM 325
12V A B GND
12
1110987
VVM 325
AA3-X4
AA9-X1
SMS40
AA3-X4
VVM325 VVM325
VVM 500
12V A B GND
12
1110987
VVM 500
AA3-X4
AA9-X1
SMS40
APH
VVM500
AA3-X4
14
GB

Control module SMO 40
SMS 40 is connected to the input board (AA3) on SMO
40.
Use cable type LiYY, EKKX or similar.
12V A B GND
12
1110987
SMO40
AA3-X4
AA9-X1
SMS40
L N 1 1 0 2 3 4PE
1 2 3 4
LEK
AA3-X4
Several accessories with SMS 40
If SMS 40 is to be connected together with MODBUS 40,
MODBUS 40 must be the first unit connected to the
heat pump/indoor module terminal block.
Connection to and from SMS 40/MODBUS 40 occurs
in terminal block AA9:X1.
No more than two units can be connected to the heat
pump/indoor module.
Heat pump/
Indoor module
MODBUS 40/
SMS 40
Accessory 2
Tillbehör_singular = translation hint, 2 =
value
SMS 40
SMS 40
B
A
+12V
GND
B
A
+12V
GND
Accessory 2
Accessory 1 Heat pump/Indoor module
Tillbehör_singular = translation hint, 1&2 =
value
15
GB

Settings
LEK
Space for
SIM card
Space for battery
Space for SIM
card
Installing SIM card:
1. Carefully slide the holder to one side.
2. Fold up the holder, then place the SIM card into the
card holder cover.
If you want SMS 40 to send SMSs in the event of a
power cut, carry out the following:
■Install a 9V battery on the circuit board in SMS 40.
■Position the jumper according to the image below.
Jumper
Moved
Caution
The pin code must be deactivated and if it is
pay as you go there must be credits on the
card.
16
GB

Quick start guide
Program setting of SMS 40 can be performed via the
start guide or directly in the menu system.
1. Start the heat pump/indoor module and select
SMS 40 in menu 5.2 "system settings" (menu 5.2.4
"accessories" for NIBE F1345, VVM 310, VVM 320,
VVM 325 and VVM 500).
2. Go to menu 4.1.4 in your heat pump/indoor mod-
ule (menu 5.3.5 if your heat pump/indoor module
has software version 2041 or earlier) and add the
mobile numbers that are to have access to change
and receive status information from the heat
pump/indoor module. Mobile numbers must in-
clude country code e.g. +46 XXXXXXXX.
3. If you wish to receive a SMS-message in the event
of the alarm mark the box to the right of the tele-
phone number.
sms 4.1.4
phone number alarm receiver
NOTE
Telephone numbers provided must be able to
receive SMS messages.
Download the app
If the mobile telephone also has the Android operating
system the mobile application ”NIBE Mobile App” can
be used”. In the event of an alarm, SMS 40 can send
an SMS to the programmed recipient and present it
graphically.
1. Enter Android Market in the web browser
2. Search on NIBE Mobile App
3. Download
Or scan in the qr code below using your Android-tele-
phone.
(requires scanner software in the phone).
17
GB

Contact with SMS 40
SMS commands
SMS 40 sends an SMS in the event of a power cut, when the heat pump/indoor module starts after a power cut and
in the event of a constant alarm. These messages are only sent to the alarm recipient (menu 4.1.4, menu 5.3.5 if your
heat pump/indoor module has software version 2041 or earlier)
Caution
The command that is sent to/from SMS 40 must always be written as one word, for example "?solar".
SMS 40 can receive and send the following commands to the heat pump/indoor module:
DescriptionAnswerCommand
Operating statusopmode: auto/add. heat only?status
Temperature (offsetting the heat curve in systems without room
sensors)
reg1: -10-+10
Temperature (offsetting heat curve in systems without room sensor),
climate systems 21)
reg2: -10-+10
Temperature (offsetting heat curve in systems without room sensor),
climate systems 31)
reg3: -10-+10
Temperature (offsetting heat curve in systems without room sensor),
climate systems 41)
reg4: -10-+10
Temperature (setting the room temperature in systems with room
sensors)
roomt1: 5-30
Temperature (setting the room temperature in systems with room
sensors), climate system 21)
roomt2: 5-30
Temperature (setting the room temperature in systems with room
sensors), climate system 31)
roomt3: 5-30
Temperature (setting the room temperature in systems with room
sensors), climate system 41)
roomt4: 5-30
Temporary lux (hot water)tluxhw: on/off
Fan speed. 0 = normal fan speed2), 3+1), 4+1)
vent: 0/1/2/3/4
Holiday settinghol: on/off
Compressor status2), 3)
status: runs/off?comp
Number of compressor starts2), 3)
number of starts: nn
Total run time compressor and immersion heater?2), 3)
total operating time: nn
Total run time hot water2), 3)
- of which hot water: nn
Compressor status per cooling module (EP14 respectively EP15)4)
status: runs/off?compm/?comps1
– ?comps8 Compressor status =through outdoor section (EB10X)7)
Number of compressor starts per cooling module (EP14 respectively
EP15)4), 7)
number of starts: nn
Total run time, compressor per cooling module (EP14 respectively
EP15)4), 7)
total operating time: nn
Total run time, hot water per cooling module (EP14 respectively
EP15)4), 7)
- of which hot water: nn
Number of compressors that produce heat4), 7)
heating: nn?acomp
Number of compressors that charge hot water 4), 7)
hot water: nn
Number of compressors that charge pool 14+1), 7+1)
pool: nn
Number of compressors that charge pool 24+1), 7+1)
pool 2: nn
Supply temperatureflow: nn?temp
Return tempreturn: nn
Outdoor temperatureoutd: nn
Indoor temperature. If the room temperature sensor is not in-
stalled/activated, the following appears -
indoor: nn
18
GB

Calculated flow line temperaturecalcf:nn
Degree minutesDM: nn
Incoming brine temperature3), 4)
Bin: nn
Outgoing brine temperature3), 4)
Bout: nn
Hot water temp.hw: nn
Status of charge pump for solar accessories1)
pump: runs/off?solar
Solar panel temperature1)
BT53: nn
Solar tank temperature, coil1)
BT54: nn
Solar tank temperature, peak2+1)
BT55: nn
Status of additionstatus: blocked/off/nn kW2), 3),
5)/ nn (number of steps)4)
?as
Time factor on addition2), 3), 4), 5), 7)
time factor: nn
Total run time hot water6)
- of which hot water: nn
DescriptionAnswerParameterCommand
Change operating mode?status0/1!op
Auto/add. heat only
Temporary lux, hot water. 0/3/6/12 hours.?status0/3/6/12!tlhw
Temperature (offsetting the heat curve in systems without
room sensors)
?status-10-+10!reg1
Temperature (offsetting heat curve in systems without room
sensor), climate systems 21)
?status-10-+10!reg2
Temperature (offsetting heat curve in systems without room
sensor), climate systems 31)
?status-10-+10!reg3
Temperature (offsetting heat curve in systems without room
sensor), climate systems 41)
?status-10-+10!reg4
Temperature (setting the room temperature in systems with
room sensors)
?status5-30!roomt1
Temperature (setting the room temperature in systems with
room sensors), climate system 21)
?status5-30!roomt2
Temperature (setting the room temperature in systems with
room sensors), climate system 31)
?status5-30!roomt3
Temperature (setting the room temperature in systems with
room sensors), climate system 41)
?status5-30!roomt4
activating/deactivating holiday settings?status1/0!vac
Resets alarm!alarm
Changed fan speed. 0= normal fan speed2), 3+1), 4+1)
0/1/2/3/4!vent
1) Accessories are required
2) Applies to F370 F470 and F750.
3) Applies to F1145/F1155 and F1245/F1255
4) Applies to F1345
5) Applies to VVM 310, VVM 320, VVM 325 and VVM 500
6) Applies to F750
7) Applies to SMO40
Example
To check the selected operating mode, the following SMS message is sent: ?status
To activate "Temporary lux, hot water" for 12 hours, the following SMS message is sent: !tlhw 12
Both commands are answered with a status message.
19
GB

Troubleshooting
SMS 40 has no contact with the GSM net-
work
SMS 40 does not reply to the SMS command and a
symbol for lost connection to G network appears in
heat pump/indoor module menu 4.1.4 (menu 5.3.5 if
your heat pump/indoor module has software version
2041 or earlier).
sms 4.1.4
phone number alarm receiver
■Check that the SIM card is correctly installed.
■Move the antenna to a better location.
■Check that the PIN has been deactivated.
SMS 40 has no contact with the heat
pump/indoor module
■The alarm in the heat pump/indoor module display.
■See section Disturbances in comfort in the manual
for the heat pump/indoor module.
■Incorrectly connected cables between SMS 40 and
heat pump/indoor module.
No reply to the SMS message
■The telephone number is not registered in heat
pump/indoor module menu 4.1.4 (menu 5.3.5 if your
heat pump/indoor module has software version 2041
or earlier).
Technical data
Technical specifications
12 VDC 45-80 mARated voltage
850/900/1800/1900(MHz)GSM
067 073Part No.
108 x 154 x 39(mm)Dimensions
20
GB
Other manuals for SMS 40
4
Table of contents
Languages:
Other Nibe Control Unit manuals
Popular Control Unit manuals by other brands

ITRON
ITRON EquaScan hMIURFV2 Assembly instruction

Hydac
Hydac FCU 8000 Series Operating and maintenance instructions

Domestia
Domestia DMA-004-004 user manual

Lucent Technologies
Lucent Technologies Stinger Guide

Allen-Bradley
Allen-Bradley 1794-OA8K installation instructions

Neat
Neat INKA Technical handbook

Linear Technology
Linear Technology DC1573A Demo Manual

System Sensor
System Sensor M210EA-CZR installation instructions

Sonel
Sonel OR-1 operating manual

Sandpiper
Sandpiper HDF4-A Service & operating manual

Allen-Bradley
Allen-Bradley ControlLogix ControlNet Scanner Module Installation instructions manual

UTICOR
UTICOR TOUGH UT3 Series manual