Mounting
The reversing valve (QN10) is always installed between
the heat source and the hot water accumulator/rest
of the system. In the starting mode, without control
voltage, the reversing valve must be open to the rest
of the system. When control voltage is applied the re-
versing valve opens to the hot water accumulator.
Installing the valve motor
Example installation:
1. Ensure that the depression, in the shaft (1a) and
the shaft on the valve (1b), are at 12 o'clock with
the port up. In this example ▲ and ■ are open while
● to begin with is closed.
2. Ensure that the knob on the motor is turned all the
way to the left.
3. Turn the knob to the right to close ▲ and open ●.
180°
1. 2.
LEK
LEK
LEK
LEK
LEK
LEK
The symbols are marked on the terminals.
Changing the direction of rotation
NOTE
Electrical installation and service must be car-
ried out under the supervision of a qualified
electrician. Cut the current with the circuit
breaker before carrying out any servicing.
Electrical installation and wiring must be car-
ried out in accordance with the stipulations in
force.
Change the direction of rotation on the valve motor
as necessary.
1. Slacken off the screws and cap on the valve motor.
180°
1. 2.
LEK
LEK
LEK
LEK
LEK
LEK
2. Pull out the pins, turn them 90 ° and put them back.
9