PI P-603 Series User manual

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 2 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Contents
About this Document 4
Symbols and Typographic Conventions ............................................................................................... 4
Other Applicable Documents............................................................................................................... 5
Downloading Manuals ......................................................................................................................... 5
Safety 5
Intended Use........................................................................................................................................ 5
Safety Precautions ............................................................................................................................... 6
Electrical Dangers .....................................................................................................................................6
Mechanical Dangers .................................................................................................................................8
Thermal Dangers ...................................................................................................................................... 9
Product Description 9
Model Overview................................................................................................................................... 9
Product View...................................................................................................................................... 10
Scope of Delivery................................................................................................................................ 10
Suitable Electronics............................................................................................................................ 10
Unpacking 11
Installation 12
Preventing the Risk of Electric Shock................................................................................................. 12
Preparing a P-603 with Stranded Wires for Connection to a Controller ........................................... 12
Mounting the P-603 and Mounting a Load........................................................................................ 12
Startup and Operation 13
Starting and Operating the P-603 ...................................................................................................... 13
Discharging the P-603 ........................................................................................................................ 14
Maintenance 14
Cleaning the P-603 ............................................................................................................................. 15
Customer Service 15
Technical Data 16
Specifications ..................................................................................................................................... 16

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 3 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Maximum Ratings .............................................................................................................................. 17
Ambient Conditions and Classifications............................................................................................. 18
Dimensions......................................................................................................................................... 19
Pin Assignment................................................................................................................................... 20
Old Equipment Disposal 21

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 4 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
About this Document
This user manual contains information necessary for the intended use of the P-603.
It assumes that the reader has a fundamental understanding of basic servo systems as well as
motion control concepts and applicable safety procedures.
Symbols and Typographic Conventions
The following symbols and typographic conventions are used in this user manual:
CAUTION
Dangerous situation
Failure to comply could lead to minor injury or cause damage to equipment.
Precautionary measures for avoiding.
NOTICE
Dangerous situation
Failure to comply could cause damage to equipment.
Precautionary measures for avoiding.
INFORMATION
Additional information that can affect your application.
Symbol/Label
Meaning
1.
2.
Action consisting of several steps with strict sequential order
Action consisting of one or more steps without relevant sequential order
List item
p. 5 Cross-reference to page 5
RS-232 Labeling of an operating element on the product (example: socket of the
RS-232 interface)
Warning sign on the product that refers to detailed information in the
documentation.

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 5 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Other Applicable Documents
The devices mentioned in this technical note are described in separate manuals.
Product
Document
E-610 piezo amplifier / servo controller
PZ70 user manual
PZ72 user manual
E-625 piezo servo controller
PZ167 user manual
E-831 piezo amplifier module
PZ191 user manual
PZ235 user manual
Downloading Manuals
INFORMATION
If a manual is missing or problems occur with downloading:
Contact our customer service department (p. 15).
Downloading manuals
1. Open the website www.pi.ws.
2. Search the website for the product number (e.g., P-603) or the product family (e.g.,
PiezoMove).
3. Click the corresponding product to open the product detail page.
4. Click the Downloads tab.
The manuals are shown under Documentation. Software manuals are shown under
General Software Documentation.
5. Click the desired manual and fill out the inquiry form.
The download link will then be sent to the email address entered.
Safety
Intended Use
The P-603 PiezoMove linear actuator is intended to be used in an environment which is free of
dirt, oil, and lubricants.
In accordance with its design, the P-603 is intended for the following applications:
Positioning of loads
Dynamic positioning
Vibration damping
Force generation

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 6 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
The P-603 is designed to be integrated into systems that meet the EN 61010-1 safety standard
and the EN 61326-1 EMC standard. The operator is responsible for electrical safety and
electromagnetic compatibility when integrating the P-603 into the overall system. The P-603
complies with the RoHS directive, i.e., the standards defined by EN 50581.
The motion of the P-603 takes place on one axis. The P-603.xSx versions are equipped with
position sensors.
The P-603 can only be used as intended in conjunction with suitable drive and control
electronics (p. 10) available from PI. The electronics are not included in the scope of delivery of
the P-603.
The electronics must provide the required operating voltages. To ensure proper performance of
the servo-control system (P-603.xSx only), the electronics must also be able to read out and
process the signals from the position sensors.
For information about the electronics refer to their separate documentation (p. 5).
Safety Precautions
Electrical Dangers
CAUTION
Dangerous voltage and residual charge in piezo actuators!
The P-603 can remain charged if its connecting cable is disconnected from the electronics
during operation. Touching the live parts of the P-603 can result in minor injury from electric
shock.
Do not disconnect the P-603 from the electronics during operation. If the P-603’s
connecting cable was accidentally disconnected from the electronics during operation,
discharge the P-603 appropriately (p. 14).
CAUTION
Dangerous voltage in piezo actuators during operation!
During operation, the piezo actuator of the P-603 carries voltages of up to 120 V. Touching the
P-603 can lead to minor injuries from electric shock.
Do not touch the P-603 during operation.
Before startup, insulate the piezo actuator of the P-603 electrically from the surrounding
mechanical system to prevent direct or indirect contact with live parts. Pay attention to the
clearances and creepage distances required for the operating voltage, and pay attention to
the standards applicable to your application.

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 7 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
CAUTION
Risk of electric shock if the protective earth conductor is not connected!
The system into which the P-603
is integrated (e.g., housing or surrounding mechanical system)
must be connected to a protective earth conductor. If the protective earth conductor is not or
not properly connected, touching the system in which the piezo actuator was incorporated can
lead to minor injury from electric shock in the case of a malfunction.
Before startup, connect the overall system to a protective earth conductor in accordance
with the applicable standards.
Do not remove the protective earth conductor during operation.
If the protective earth conductor has to be temporarily removed (e.g., for modifications),
reconnect the overall system to the protective earth conductor before starting it up again.
NOTICE
Destruction of the piezo actuator by electric flashovers!
The use of the P-603 in environments that increase the electrical conductivity can lead to the
destruction of the piezo actuator by electric flashovers. Electric flashovers can be caused by
moisture, high humidity, liquids and conductive materials such as metal dust. In addition,
electric flashovers can also occur in certain air pressure ranges due to the increased
conductivity of the air.
Avoid operating the P-603 in environments that can increase the electric conductivity.
Only operate the P-603 within the permissible ambient conditions and classifications
(p. 18).
NOTICE
Destruction of the piezo actuator by continuously high voltage!
The constant application of high voltage to piezo actuators can lead to leakage currents and
flashovers that destroy the ceramic.
If the P-603 is not used, but the controller is to remain switched on to ensure temperature
stability:
Set the piezo voltage to 0 V on the controller.

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 8 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Mechanical Dangers
NOTICE
External push or pull forces!
External push or pull forces acting on the moving part (p. 10) in the direction of motion can
cause damage to the P-603.
The maximum permissible forces depend on the model:
P-603.1xx:
Do not exceed the maximum push force of 40 N on the moving part.
Do not exceed the maximum pull force of 20 N on the moving part.
P-603.3xx:
Do not exceed the maximum push force of 35 N on the moving part.
Do not exceed the maximum pull force of 13 N on the moving part.
P-603.5xx:
Do not exceed the maximum push force of 30 N on the moving part.
Do not exceed the maximum pull force of 10 N on the moving part.
In dynamic operation, take special care not to exceed the maximum push/pull forces.
NOTICE
Mechanical overload due to high torques!
High torques can damage the P-603 and lead to loss in accuracy.
When mounting the P-603 onto a surface:
Do not exceed a torque of 0.7 Nm for the mounting holes in the mounting interface
(p. 10).
When fixing a load to the P-603:
Do
not
exceed a torque of
0.5 Nm
for the mounting holes in the moving part (p. 10).
NOTICE
Uncontrolled oscillation!
Oscillations can cause irreparable damage to the P-603. Oscillations are indicated by a
humming and can result from the following causes:
The load and/or dynamics of operation differ too much from the calibration settings.
The P-603 is operated near to its resonant frequency.
If you notice oscillations, stop the P-603 immediately.

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 9 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
NOTICE
Damage after reconnecting due to a charged P-603!
The P-603 can remain charged if its connecting cable is disconnected from the electronics
during operation. Reconnecting a charged P-603 to electronics during operation can cause a
mechanical impulse that will damage the P-603.
Do not disconnect the P-603 from the electronics during operation.
If the P-603’s connecting cable was accidentally disconnected from the electronics during
operation, switch off the electronics before reconnecting.
Thermal Dangers
CAUTION
Burning from hot surface!
The surface of the P-603 and the surrounding area can heat up during operation. Touching the
P-603 and surrounding parts can result in minor injuries from burning.
Make sure that the hot P-603 and its surrounding parts cannot be touched.
NOTICE
Heating up of the P-603 during operation!
The heat produced during dynamic operation of the P-603 can affect your application.
Install the P-603 so that your application is not affected by the dissipating heat.
Product Description
Model Overview
Model Travel range Sensor Connection to electronics
P-603.101
100 µm
-
Stranded wires
P-603.1S1
100 µm
SGS
Stranded wires
P-603.1S2
100 µm
SGS
LEMO
P-603.301
300 µm
-
Stranded wires
P-603.3S1
300 µm
SGS
Stranded wires
P-603.3S2
300 µm
SGS
LEMO
P-603.501 500 µm - Stranded wires
P-603.5S1
500 µm
SGS
Stranded wires
P-603.5S2
500 µm
SGS
LEMO

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 10 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Product View
Figure 1: Overview of the P-603 actuator
Scope of Delivery
Product number
Description
P-603
PiezoMove OEM linear actuator according to order (p. 9)
P603T0001 User manual for P-603 (this document)
Suitable Electronics
Product number
Description
Suitability
E-610
Piezo amplifier / servo controller
All P-603 models
E-625
Piezo servo controller
P-603.xSx (models with sensor)
E-831 Piezo amplifier module P-603.x01 (models without sensor)
To order, contact our customer service department (p. 15).
Direction of
external forces
Pull
Push
Moving part, the load is
fixed here
Mounting interface, the actuator is
mounted onto a surface here
PICMA® piezo actuator
Base body

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 11 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Unpacking
NOTICE
Damage due to pull forces on the connecting cable or stranded wires!
Pull forces on the connecting cable or stranded wires can damage the P-603.
Avoid pull forces on the connecting cable or stranded wires.
NOTICE
Destruction of the piezo actuator due to contamination!
Contamination on the surface of the piezo actuator of the P-603 can result in the destruction of
the piezo actuator by electric flashovers during operation.
When handling the P-603, wear powder-free nitrile or latex gloves.
Prevent the P-603 from coming into contact with conductive liquids (e.g., finger sweat) and
conductive materials (e.g., metal dust).
If the piezo actuator of the P-603 has been accidentally contaminated, contact our
customer service department (p. 15).
NOTICE
Destruction of the piezo actuator by mechanical overload!
Mechanical forces can damage the piezo actuator of the P-603.
Avoid impacts that affect the P-603.
Do
not
drop the P-603.
Unpacking the P-603
1. Unpack the P-603 with care.
2. Compare the contents with the scope of delivery according to the contract and the
delivery note.
3. Inspect the contents for signs of damage. If any parts are damaged or missing, contact
our customer service department immediately.
4. Keep all packaging materials in case the product needs to be returned.

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 12 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Installation
Preventing the Risk of Electric Shock
The P-603 actuator does not feature a separate protective earth connection, but must be installed
in a way that a risk of electric shock is prevented.
You have the following options:
Mount the actuator onto an electrically conductive surface that is connected to a
protective earth conductor.
Connect the actuator to a protective earth conductor via its mounting interface.
Install the actuator such that it is electrically insulated according to protection class II.
When you choose the first or the second option:
1. Pay attention to the applicable standards for mounting the protective earth conductor.
2. Make sure that the contact resistance is <0.1 Ω at 25 A at all connection points relevant
for mounting the protective earth conductor.
3. Install touch protection (e.g., housing, insulation) to prevent direct or indirect contact
with live parts.
Preparing a P-603 with Stranded Wires for Connection to a
Controller
When you prepare a P-603 actuator with stranded wires for connection to a controller, pay
attention to the assignment of the stranded wires as specified in “Color coding of stranded wires”
(p. 21).
Mounting the P-603 and Mounting a Load
Figure 2: Mounting interface and moving part
Moving part, the load is
fixed here
Mounting interface, the actuator is
mounted onto a surface here

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 13 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Requirements
You have read and understood the safety precautions (p. 6).
You have provided a suitable underlying surface for mounting the P-603:
-The surface is connected to a protective earth conductor (p. 12).
-The surface has two suitable through holes. Refer to “Dimensions” (p. 19) for
details.
-The holes for the screws are sufficiently conductive to ensure that the protective
earth conductor functions properly.
-The flatness of the surface is ≤40 µm.
You have discharged the P-603 (p. 14).
Tools and accessories
Two M2.5 screws of suitable length (p. 19) for mounting the actuator onto a surface
Two M2.5 screws of suitable length (p. 19) for mounting a load to the actuator
Suitable tools
Mounting the P-603 and mounting a load
1. Only mount the P-603 onto a surface using the mounting holes intended for this purpose
(refer to Figure 2, p. 12).
Maximum torque: 0.7 Nm
2. Only fix a load to the P-603 using the mounting holes intended for this purpose (refer
to Figure 2, p. 12).
Maximum torque: 0.5 Nm
Startup and Operation
Starting and Operating the P-603
Requirements
You have read and understood the safety precautions (p. 6).
Starting and operating the P-603
Follow the instructions in the user manual for the electronics used for startup and
operation of the P-603.

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 14 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Discharging the P-603
The P-603 must be discharged in the following cases:
Before installation
When the P-603 is not in use but the electronics remains switched on to ensure
temperature stability
Before demounting (e.g., before cleaning and transporting the P-603 and for
modifications)
If the connecting cable of the P-603 is accidentally disconnected from the electronics
during operation
Requirements
You have read and understood the safety precautions (p. 6).
Tools and accessories
If the P-603 is not connected to the electronics:
Only for P-603 without connector:
10 kΩ discharge resistor (not included in scope of delivery), the touchable parts must be
adequately insulated for the actuator's operating voltage range (p. 17)
Only for P-603 with connector:
Electronics from PI
Discharging a P-603 connected to the electronics
Set the piezo voltage to 0 V on the electronics.
Discharging a P-603 not connected to the electronics
If the P-603 does not have a connector:
1. Ensure adequate protection against touching live parts.
2. Short-circuit the stranded wires of the P-603 for at least a few seconds using a 10 kΩ
discharge resistor.
If the P-603 has a connector:
Connect the voltage connector of the P-603 to the switched off PI electronics, which
have an internal discharge resistor, for at least a few seconds.
Maintenance
The P-603 is maintenance-free.

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 15 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Cleaning the P-603
Requirements
You have discharged the P-603 (p. 14).
You have disconnected the P-603 from the electronics.
Cleaning the P-603
Touch the piezo actuator only with powder-free nitrile or latex gloves.
Use pH-neutral cleansers only.
Do not use acetone and do not use water for cleaning.
When necessary, clean the base body (not the actuator!) of the P-603 with a lint-free
cloth that is dampened with a mild cleanser (e.g., isopropanol or ethanol).
Customer Service
For inquiries and orders, contact your PI sales engineer or send us an email (service@pi.de).
If you have any questions concerning your system, provide the following information:
−Product and serial numbers of all products in the system
−Firmware version of the controller (if applicable)
−Version of the driver or the software (if applicable)
−Operating system on the PC (if applicable)
If possible: Take photographs or make videos of your system that can be sent to our
customer service department if requested.
The latest versions of the user manuals are available for download (p. 5) on our website.

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 16 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Technical Data
Specifications
P-603.1S1
P-603.1S2
P-603.3S1
P-603.3S2
P-603.5S1
P-603.5S2
P-603.x01
Open-loop
versions
Unit
Active axes Z Z Z Z
Motion and positioning
Integrated sensor SGS SGS SGS –
Travel range at -20 to 120 V,
open loop
120 380 550 as P-603.xS1 µm
Travel range, closed loop 100 300 500 – µm
Resolution, open loop, 180 g 2 3 5 as P-603.xS1 nm
Resolution, closed loop, 180 g 10 20 25 – nm
Linearity error, closed loop 0.2 0.2 0.2 – %
Unidir. Repeatability, 10%,
1 Sigma
7 10 20 – nm
Mechanical properties –
Stiffness in motion direction 0.3 0.14 0.06 as P-603.xS1 N/µm
Resonant frequency, no load 900 410 300 as P-603.xS1 Hz
Resonant frequency, under
load, 180 g
160 110 80 as P-603.xS1 Hz
Push/pull force capacity in
motion direction
40 / 20 35 / 13 30 / 10 as P-603.xS1 N
Drive properties
Piezo ceramic PICMA® P-885 PICMA® P-885 PICMA® P-885 as P-603.xS1
Electrical capacitance 1.5 3.1 3.7 as P-603.xS1 µF
Miscellaneous
Operating temperature range -20 to 80 -20 to 80 -20 to 80 as P-603.xS1 °C
Material Stainless steel Stainless steel Stainless steel as P-603.xS1
Dimensions 33.5 mm ×
21 mm × 6 mm
52 mm × 21 mm ×
6 mm
62 mm × 21 mm ×
6 mm
as P-603.xS1
Mass S1 version: 0.03
S2 version: 0.04
S1 version: 0.04
S2 version: 0.05
S1 version: 0.05
S2 version: 0.06
as P-603.xS1 kg
Cable length 0.5 0.5 0.5 as P-603.xS1 m

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 17 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
P-603.1S1
P-603.1S2
P-603.3S1
P-603.3S2
P-603.5S1
P-603.5S2
P-603.x01
Open-loop
versions
Unit
Voltage connection S1 versions: Bare
stranded wires
S2 versions:
LEMO (low
voltage)
S1 versions: Bare
stranded wires
S2 versions:
LEMO (low
voltage)
S1 versions: Bare
stranded wires
S2 versions:
LEMO (low
voltage)
as P-603.xS1
Sensor connection S1 versions: Bare
stranded wires
S2 versions:
LEMO (strain
gauge sensor)
S1 versions: Bare
stranded wires
S2 versions:
LEMO (strain
gauge sensor)
S1 versions: Bare
stranded wires
S2 versions:
LEMO (strain
gauge sensor)
–
Recommended electronics E-610, E-625 E-610, E-625 E-610, E-625 E-610, E-831
The resolution of the system is only limited by the noise of the amplifier and measuring technology because PI piezo
actuators are free of friction.
Ask about customized versions.
Maximum Ratings
P-603 PiezoMove linear flexure actuators are designed for the following operating data:
Model
Maximum operating
voltage
Maximum operating
frequency (unloaded)1
Maximum power
consumption2
P-603.101 -20 to 120 V 300 Hz 6 W
P-603.1S1
-20 to 120 V
6 W
P-603.1S2
-20 to 120 V
6 W
P-603.301
-20 to 120 V
135 Hz
8 W
P-603.3S1
-20 to 120 V
8 W
P-603.3S2
-20 to 120 V
8 W
P-603.501
-20 to 120 V
100 Hz
10 W
P-603.5S1
-20 to 120 V
10 W
P-603.5S2
-20 to 120 V
10 W
1To ensure stable operation, the maximum operating frequency is defined as approximately 1/3 of
the mechanical resonant frequency.
2The heat generated by the piezo actuator during dynamic operation limits the value for maximum
power consumption.
Details can be found online:
https://www.physikinstrumente.com/en/technology/piezo-technology/properties-piezo-
actuators/electrical-operation/

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 18 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Ambient Conditions and Classifications
Pay attention to the following ambient conditions and classifications for the P-603:
Area of application
For indoor use only
Maximum altitude
2000 m
Air pressure
1100 hPa to 0.1 hPa
Relative humidity
Highest relative humidity 80 % for temperatures up to 31 °C
Decreasing linearly to 50 % relative humidity at 40 °C
Storage temperature -20°C to 80°C
Transport temperature
-25°C to 85°C
Overvoltage category
II
Degree of pollution
1
The P-603 is intended for installation in devices that fulfil the following classifications:
Protection class I
Degree of protection
according to IEC 60529
IP20

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 19 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Dimensions
Dimensions in mm. Note that a comma is used in the drawings instead of a decimal point.
Model A C D Unit
P-603.1S1 / .1S2 / .101 33.5 3.5 5.5 mm
P-603.3S1 / .3S2 / .301 52 3.5 5.6 mm
P-603.5S1 / .5S2 / .501 62 4.5 6.2 mm
Figure 3: Dimensions of the P-603 (.x01 models without sensor)

User Manual
P603T0001, valid for P-603
CBo, 1/11/2021
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 20 / 21
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Pin Assignment
Sensor connector
P-603.xS2 only
Figure 4: Sensor connector, LEMO FFA.0S.304.CLAC32, front view
Pin
Function
1
Reference (5 V)
2
Sensor -
3
Sensor +
4
GND
PZT connector
P-603.xS2 only
Figure 5: PZT connector, LEMO FFA.00.250.CTAC15, front view (left)
Pin
Function
Inner contact
PZT + (-20 to 120 V)
Connector shell
PZT - (GND)
This manual suits for next models
9
Table of contents
Other PI Controllers manuals
Popular Controllers manuals by other brands

rauland
rauland 2524 ChronoCom Operation manual

SMC Networks
SMC Networks AS 0 2F Series Operation manual

Synergy Global Technology
Synergy Global Technology RAC281 user manual

Central Boiler
Central Boiler FireStar Operation manual

Desert Aire
Desert Aire CM3500 Series Installation and operation manual

DeWalt
DeWalt DXCM019-0343 manual