Technical Note
LS270T0003, valid for LS-270
pmMSu, ASt, 9/27/2023
PI miCos GmbH, Freiburger Straße 30, 79427 Eschbach, Germany Page 3 / 8
Phone
+49 7634 5057-0, fax +49 7634 5057-99, e-mail info@pimicos.ws, www.pi.ws
1Material and Tools Required
Lint-free cloths
Acetone as a solvent
Drive screw lubricant: Klüber ISOFLEX NBU 15 (PI article number: K4920019)
Linear guide lubricant: Shell Alvania EP(LF) 2 grease
SW 5 and SW 2 hex keys
2Maintenance Cycles
2.1 Linear guide
Relubrication must take place every three months, but after 600 km at the latest.
The lubricant is applied to the linear guide with a grease gun using the grease nipples provided.
2.2 Drive screw
The drive screw requires relubrication ca. every two months based on the grease that seeps
from the wipers. (Under normal operating conditions, it is sufficient to relubricate every 200 to
300 operating hours.)
The lubricant is applied to the drive screw using a clean paintbrush or brush.
Lubricant is applied to the nut with a grease gun using the grease nipples provided.
3Relubrication
Making the Components Accessible for Lubrication
1. Move the slider to the end position towards the motor.
2. Disconnect all electrical connections so that the axis is voltage-free.
Do not change the position of the axis during cleaning. For example, if the axis is set up
vertically, the slider can move due to its intrinsic weight and cause injury.