manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ResMed
  6. •
  7. Respiratory Product
  8. •
  9. ResMed VPAP Auto User manual

ResMed VPAP Auto User manual

Other manuals for VPAP Auto

2

This manual suits for next models

1

Other ResMed Respiratory Product manuals

ResMed Mirage Activa LT User manual

ResMed

ResMed Mirage Activa LT User manual

ResMed Swift FX User manual

ResMed

ResMed Swift FX User manual

ResMed Quattro Air User manual

ResMed

ResMed Quattro Air User manual

ResMed AirFit F30 User manual

ResMed

ResMed AirFit F30 User manual

ResMed Quattro FX NV User manual

ResMed

ResMed Quattro FX NV User manual

ResMed Ultra Mirage User manual

ResMed

ResMed Ultra Mirage User manual

ResMed Nasal Pillows System Swift LT User manual

ResMed

ResMed Nasal Pillows System Swift LT User manual

ResMed Flow Generator S8 Elite System User manual

ResMed

ResMed Flow Generator S8 Elite System User manual

ResMed AirFit N30i User manual

ResMed

ResMed AirFit N30i User manual

ResMed Ultra Mirage User manual

ResMed

ResMed Ultra Mirage User manual

ResMed Mirage NV Full Face Mask Series 2 User manual

ResMed

ResMed Mirage NV Full Face Mask Series 2 User manual

ResMed Mirage Quattro User manual

ResMed

ResMed Mirage Quattro User manual

ResMed VPAP VPAP Adapt SV System User manual

ResMed

ResMed VPAP VPAP Adapt SV System User manual

ResMed Quattro Air User manual

ResMed

ResMed Quattro Air User manual

ResMed AirTouch N20 Assembly instructions

ResMed

ResMed AirTouch N20 Assembly instructions

ResMed Hospital Full Face Mask User manual

ResMed

ResMed Hospital Full Face Mask User manual

ResMed Pixi User manual

ResMed

ResMed Pixi User manual

ResMed C16389 User manual

ResMed

ResMed C16389 User manual

ResMed Quattro Air NV Installation and operating instructions

ResMed

ResMed Quattro Air NV Installation and operating instructions

ResMed Silent Papillon MAP Series User manual

ResMed

ResMed Silent Papillon MAP Series User manual

ResMed AutoSet User manual

ResMed

ResMed AutoSet User manual

ResMed Non-Vented Full Face Mask Hospital Mask User manual

ResMed

ResMed Non-Vented Full Face Mask Hospital Mask User manual

ResMed Mirage Quattro 61836/2 User manual

ResMed

ResMed Mirage Quattro 61836/2 User manual

ResMed VPAP Adapt Technical manual

ResMed

ResMed VPAP Adapt Technical manual

Popular Respiratory Product manuals by other brands

Omron COMP A-I-R NE-C801 instruction manual

Omron

Omron COMP A-I-R NE-C801 instruction manual

CERES nosko nebulizer kit manual

CERES

CERES nosko nebulizer kit manual

Dr.Frei NE-SM1 user manual

Dr.Frei

Dr.Frei NE-SM1 user manual

North 5400 series instruction manual

North

North 5400 series instruction manual

John Bunn Neb-u-Lite LX2 user manual

John Bunn

John Bunn Neb-u-Lite LX2 user manual

DeVilbiss UltraNeb user manual

DeVilbiss

DeVilbiss UltraNeb user manual

Sperian Panther Hip-Pac P9684 Series Operation manual

Sperian

Sperian Panther Hip-Pac P9684 Series Operation manual

Dräger X-plore 6570 quick start guide

Dräger

Dräger X-plore 6570 quick start guide

3M 8000 Series quick start guide

3M

3M 8000 Series quick start guide

Respironics SideStream HS860 Instructions for use

Respironics

Respironics SideStream HS860 Instructions for use

Sundstrom SR 500 Instructions for use

Sundstrom

Sundstrom SR 500 Instructions for use

JARDIBRIC KPBRU20 instructions

JARDIBRIC

JARDIBRIC KPBRU20 instructions

Ombra 63506 Instructions for use

Ombra

Ombra 63506 Instructions for use

Lotus M-9520A quick start guide

Lotus

Lotus M-9520A quick start guide

Philips Respironics EE Leak 1 AF541 Instructions for use

Philips

Philips Respironics EE Leak 1 AF541 Instructions for use

EVOLU Nano AiR MINI user manual

EVOLU

EVOLU Nano AiR MINI user manual

Ambu SPUR II Instructions for use

Ambu

Ambu SPUR II Instructions for use

MSA AUER 3S-PF manual

MSA AUER

MSA AUER 3S-PF manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

VPAP™Auto is a compact bilevel device designed to deliver effective therapy as naturally
and comfortably as possible. VPAP Auto combines the clinically proven AutoSet™
algorithm with the supreme comfort of ResMed’s Easy-Breathe™technology to make
breathing easier for patients with obstructive sleep apnea (OSA), noncompliant CPAP
users, and those who require additional pressure support. Packaged in ResMed’s
compact and convenient S8™design, VPAP Auto is ideal for travel or home use.
VPAP™Auto
VPAP Auto with Easy-Breathe . . . the next level in bilevel.
Quiet comfort with Easy-Breathe
Featuring Easy-Breathe, ResMed’s new
comfort technology, VPAP Auto offers
nearly silent therapy and greater pressure
stability so patients sleep comfortably
throughout the night. VPAP Auto uses
the smooth pressure delivery of the
VPAP Adapt SV™and synchronizes with
the patient’s normal respiration so that
breathing feels more natural and
comfortable.
Simple setup
VPAP Auto’s carefully selected default
settings and auto-adjusting VAuto mode
mean one-touch setup is all that is needed
for many patients.
Proven technology, effective treatment
VAuto mode uses AutoSet technology to
automatically adjust to a patient’s pressure
needs as they vary throughout the night.
With ResMed’s clinically proven AutoSet
algorithm, VPAP Auto is able to detect
flow limitation and act preemptively to
prevent apneic and snoring events.
Equipped with three modes (VAuto, S and
CPAP), VPAP Auto is the most versatile
device available and is compatible with the
S8 ResLink,
™HumidAire 3i,
™ResScan,
™
S8 ResTraxx™and ResControl II.
™
ResMed Corp Poway, CA, USA +1 858 746 2400 or 1 800 424 0737 (toll free), ResMed Ltd Bella Vista, NSW, Australia +61 (2) 8884 1000 or 1 800 658 189 (toll free). Offices in Austria, Brazil, Finland, France, Germany,
Hong Kong, Japan, Malaysia, Mexico, Netherlands, New Zealand, Singapore, Spain, Sweden, Switzerland, United Kingdom (see website for details). ResControl, ResLink, ResScan, ResTraxx, S8, TiControl, VPAP Adapt
SV and Vsync are trademarks of ResMed Ltd. AutoSet, HumidAire and VPAP are trademarks of ResMed Ltd and registered in U.S. Patent and Trademark Office. ©2007 ResMed. 1012117/2 07 12
Global leaders in sleep and respiratory medicine www.resmed.com
PRODUCT CODES
VPAP Auto 26301
HumidAire 3i 33906
TECHNICAL SPECIFICATIONS
Performance
Operating pressure range: 3 to 20 cm H2O
Maximum single fault pressure: 30 cm H2O
Dynamic pressure characteristics
VAuto mode: 4 to 20 cm H2O (Pressure support: 0 to 10 cm H2O)
S mode: IPAP: 5 to 20 cm H2O; EPAP: 3 to 20 cm H2O
CPAP mode: 4 to 20 cm H2O
Sound pressure level
< 24 dB (tested in accordance with the requirements of ISO 17510-1:2002)
Data storage
Data includes usage, leak, pressure, AHI, AI, tidal volume, respiratory rate
and minute ventilation
Via LCD menu: 365 sessions of summary data
Via ResLink: 365 sessions of summary data, 30 sessions of detailed data
Via ResScan Data Card: 180 sessions of summary data, two sessions of
detailed data
Dimensions (L x W x H): 4.4" x 6.5" x 5.7" (112 mm x 164 mm x 145 mm)
Weight: 2.9 lb (1.3 kg)
Power supply
Input range 100–240V, 50–60Hz, 40VA (typical power consumption),
< 100VA (maximum power consumption)
Environmental conditions
Operating temperature: 41°F to 97°F (+5°C to +36°C)
Operating humidity: 10–95% non-condensing
Electromagnetic Compatibility
Product complies with all applicable electromagnetic compatibility
requirements (EMC) for residential, commercial and light industry
environments according to IEC 60601-1-2.
Air filter
Two-layered, powder-bonded, polyester non-woven fiber
IEC 60601-1 classification
Class II (double insulated), Type CF
Note: The manufacturer reserves the right to change these specifications
without notice.
VPAP AUTO FEATURES SUMMARY
Modes of operation
• VAuto
• S (Spontaneous)
•CPAP
Product features
• Simplified standard setting menu
• Vsync™automatic leak management
• TiControl™(Ti max/min)
• Adjustable breath trigger/cycle
• Adjustable exhalation comfort
• 12V DC input (via converter)
• Auto-adjusting bilevel pressures
• Compact S8 design
• AutoSet technology
• Smooth pressure delivery
Heated humidification
• Optional, fully integrated
Data storage
• Usage and Treatment Summary (day, week, month, six-month, year)
• Usage profile
• Summary data storage
• Detailed data storage
• Remote settings adjustment
Data transfer
• Direct download to PC
• ResLink via SmartMedia card
• ResScan Data Card