
NOTE as stated above, the gas regulator should be opened slowly until
the burner ignites. If opened too quickly, particularly when the engine is
cold or if the gas tank has just been filled, it is possible that the flame may
not travel back into the boiler flue but stay in the smokebox. If this should
happen, the burner will sound quite different to normal and the blue flame
will be visible in the smokebox if viewed down the chimney from a safe
height. Should this happen, turn off the gas immediately or damage may
result and then re-light it. If the problem persists and it is not possible to
ignite the burner correctly, then a dirty jet should be suspected and
cleaned as detailed in the Gas System Troubleshooting Section.
For the first couple of minutes keep the burner on low. This is important,
as until it warms up, the flame will be a little unstable and turning it up too
much could cause it to go out. Also, with a completely full tank, liquid gas
could be drawn off instead of vaporised gas, which can also extinguish
the flame.
After a couple of minutes, the gas control valve can be opened more to
speed up steam raising. Open the gas regulator slowly to about one full
turn. The full range of adjustment (closed to fully open) is achieved within
the first full rotation of the gas regulator knob any more is unnecessary.
RUNNING THE LOCOMOTIVE
When full working pressure has been reached (between 35 and 40psi),
the safety valve will start to blow off steam. Steam generation can be
controlled by the gas valve in the right hand cab doorway. If the safety
valve blows off frequently during running, then too much steam is being
produced which wastes water and gas. Turning down the burner will
decrease the amount of steam created. Conversely, if steam pressure is
not maintained during a run, then the burner should be turned up. After a
few minutes of running it may be noticed that the gas pressure through
the burner has increased. This is due to the gas tank becoming warmer
and so increasing the gas pressure. Simply turn the gas down –this may
need to be performed several times during a run. The art of balancing
steam generation to the operational requirement by the adjustment of the
gas control valve will quickly be learned.
The gas tank has a duration of about 25 minutes, though this will vary
depending on gas valve setting. The boiler should not be allowed to run
dry, and the gas tank capacity is such that the gas should run out before
the water. When the gas is fully used up, the steam pressure in the boiler
will be seen to gradually drop until the loco comes to a halt. Should the
9