The zones (input lines) can perform the following functions in the system:
00 - exit/entry - the violation of which, when in the armed mode, will start countdown of the
entry delay time and will enable the delay for INTERIOR DELAY type zones
(violation of an INTERIOR DELAY zone without prior violation of the ENTRY/EXIT
zone will trigger an alarm immediately). Upon violation, a “zone violation” code is
sent to the report station (it is possible to skip sending this message), and, after
counting down the "entry delay time" and triggering the alarm - a “zone alarm”
code. The "entry delay" countdown can be signaled in the keypad. It is possible to
define automatically bypassing zones if no ENTRY/EXIT zone is violated during
the exit delay time”. Because of its additional functions, this zone type cannot be
used as a common zone for both partitions.
01 - delayed - when violated in the armed mode, it starts delay countdown, after which an
alarm is triggered. It will not occur if the zone is disarmed before completion of the
delay countdown. Upon violation, a “zone violation” code is sent to the report
station, after counting down the entry delay time and triggering the alarm - a “zone
alarm” code. The delay is not signaled in the keypads.
02 - interior delayed - when violated in the armed mode after previous violation of the
ENTRY/EXIT zone, it behaves like a DELAY zone. When violated in the armed
mode without previous violation of the ENTRY/EXIT zone, it behaves like an
INSTANT zone.
03 - instant - when violated in the armed mode, it immediately triggers an alarm and sends
a ”zone alarm” message to the monitoring station.
04 - day/night - when violated in the armed mode, it behaves like an INSTANT zone, while
when disarmed, it will signal violation in the keypad (unless function is disabled –
FS20, second set, option 3) and send a “zone violation” code to the station.
05 - counting L1 - when violated in the armed mode, it increases the status of the first of
three violation counters (a “zone violation” code is sent to the station), until the
number of violations specified for that counter is exceeded (programming in FS7).
Then the violation triggers an alarm (a ”zone alarm” code is sent to the report
station). By default, the count-up time is set at 30 seconds. It is possible to
program another counter count-up time (FS-123). If the preset number of
violations is not reached within this time, it will be reset. The next zone violation
will start the add-up procedure all over again. The violations are added up starting
from zero, and the count-up time starts upon the first violation after resetting the
counter. The "counting L1" function can be assigned to more than one zone, in
that case violations of those zones will be summed up. The zone will trigger an
alarm upon exceeding the programmed number of violations added up by a given
counter. Alarm can also be triggered after resetting the counting zone counter, if
the zone associated with the given counter is still violated.
06 - counting L2 - operation identical as for the "counting L1", but changes the status of the
second of the three counters.
07 - counting L3 - operation identical as for the "counting L1", but changes the status of the
third of the three counters.
08 - 24H audible - armed all the time, irrespective of whether the partition it is assigned to is
armed, or not. Each violation of this zone will trigger alarm on the BURGLARY
ALARM type outputs, in the keypad and will send a “zone alarm” code. It makes
possible to create tamper circuits and panic buttons.
09 - 24H auxiliary - armed all the time, irrespective of whether the partition it is assigned to
is armed, or not. Each violation of this zone will trigger an alarm in the keypad and
will send a “zone alarm” code. It is intended for connecting detectors such as gas
or flood sensors, etc.