CAUTION!
Before connecting any device at the installation site, verify input voltage using a multimeter. Many power supplies and
low voltage transformers operate at higher levels than listed. Any input voltage exceeding 10% of the solenoid rating
may cause severe damage to the unit and will void the warranty.
Preparing the Strike
1. Attach the faceplate to the strike body using the #12-24 x 3/8" Body Mounting screws as illustrated
on Page 3.
2. IF using the LCBMA (Latchbolt & Locking Cam Monitor), See Image below for wiring instructions.
NOTE:
The strike body ships as either a 12 or 24 volt
unit and is not field selectable.
3. VERIFY the available voltage is +/- 10% of the rated voltage of the strike body.
Preparing the Strike
4. PREPARE frame using the dimensional reference on Page 4.
5. TEST FIT the electric strike in the door frame.
6. IF there is not enough clearance between the exit device and the door strike, THEN REMOVE the
spacer plate as shown on Page 3.
Finishing the Installation
7. CONNECT the Plug in Connector to the electric strike and CONNECT wires from the Plug in
Connector leads to the power source.
8. INSTALL the electric strike unit in jamb cutout, using the provided #12-24 x 1/2" faceplate mounting
screws
9. ADJUST the strike horizontally as shown on Page 3. to accommodate any door silencers or smoke
seals
Monitoring Switches
Latchbolt Monitor (LBM)
White:
Orange:
Green:
COM
N/O
N/C
Locking Cam Monitor (LCM)
Brown:
Blue:
Yellow:
COM
N/O
N/C
* When secured