• CAUTION: To reduce the risk of fire, connect only to a circuit provided with 50/60 amperes maximum branch circuit
overcurrent protection in accordance with the ANSI/NFPA 70 National Electrical Code™.
1.5 Code and Standard References
• This VersiCharge has been designated to meet the requirements in section of the National Electric Code (NEC®).
• UL Listing with Listing Number – Siemens VersiCharge devices are listed in UL file #E348556.
• Complies with the following UL Standards: UL , UL , UL/CSA C. No./NMX-J--ANCE, UL -/CSA
C. No../NMX-J--, UL -/CSA C. No../NMX-J-/-ANCE and UL /CSA C. No./NMX-J--ANCE.
EV interface compliant to SAE J- Level II.
• The residential models have been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The
commercial models have been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This
equipment generates, uses and can radiate radio frequency energy and may cause harmful interference to radio communications if
not installed and used in accordance with the instructions. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
• Personal Protection Equipment: Use of proper personal protection equipment, including, but not limited to, eye protection, shock
protection, gloves and other appropriate protection, is recommended when installing or servicing any electrical equipment.
• Charging Circuit Interrupting Device (CCID): The Siemens VersiCharge line of EV Charging Systems includes a CCID. The CCID is
required by UL Standard 2231 and is designed to detect ground faults within the system and disconnect power from the downstream
conductors when a fault is detected.
DANGER Explosion hazard. This equipment has arcing or sparking parts that should not be
exposed to flammable vapors. This equipment should be installed at least inches above floor
or ground level. Use extreme caution and follow instructions carefully.
•Arcing component in contactor: Siemens VersiCharge EV Charging Systems include a contactor that when opened or closed will
cause a short duration arc. The contactor is enclosed in an appropriate electrical enclosure but if an arc occurs in the presence
of flammable vapors, the vapors could ignite, creating an explosion. Store flammable vapors away from all electrical equipment
and if vapors are present allow sufficient time for ventilation before operating this equipment.
1.6 Product Labels
The following symbols appear on the product label and are described here:
This label indicates the risk of hazardous voltage and electric shock which will cause death, serious injury or substantial damage.
Turn off the power supplying this VersiCharge before working inside.