manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Siemens
  6. •
  7. Security System
  8. •
  9. Siemens FT2009-U1 User manual

Siemens FT2009-U1 User manual

This manual suits for next models

1

Other Siemens Security System manuals

Siemens PCA2005-A1 User manual

Siemens

Siemens PCA2005-A1 User manual

Siemens DMS8000 Technical manual

Siemens

Siemens DMS8000 Technical manual

Siemens 3SX3235 User manual

Siemens

Siemens 3SX3235 User manual

Siemens NCC-G16 User manual

Siemens

Siemens NCC-G16 User manual

Siemens FS-RD2 User manual

Siemens

Siemens FS-RD2 User manual

Siemens FXS901 User manual

Siemens

Siemens FXS901 User manual

Siemens CP-48 Instruction Manual

Siemens

Siemens CP-48 Instruction Manual

Siemens CERBERUS  PYROTRONICS ADB-3 User manual

Siemens

Siemens CERBERUS PYROTRONICS ADB-3 User manual

Siemens FDM225 User manual

Siemens

Siemens FDM225 User manual

Siemens FDS221-W User manual

Siemens

Siemens FDS221-W User manual

Siemens IGS6-10 User manual

Siemens

Siemens IGS6-10 User manual

Siemens HMS-S User manual

Siemens

Siemens HMS-S User manual

Siemens HFPO-11 User manual

Siemens

Siemens HFPO-11 User manual

Siemens MM8000 Quick setup guide

Siemens

Siemens MM8000 Quick setup guide

Siemens SIMATRIX NEO 2GF2211-8EA Instruction manual

Siemens

Siemens SIMATRIX NEO 2GF2211-8EA Instruction manual

Siemens Cerberus PACE Guide

Siemens

Siemens Cerberus PACE Guide

Siemens milltronics MFA 4P User manual

Siemens

Siemens milltronics MFA 4P User manual

Siemens IC60 User manual

Siemens

Siemens IC60 User manual

Siemens SIPASS SK5 Installation and operation manual

Siemens

Siemens SIPASS SK5 Installation and operation manual

Siemens MM8000 Quick setup guide

Siemens

Siemens MM8000 Quick setup guide

Siemens FDM221 User manual

Siemens

Siemens FDM221 User manual

Siemens SISTORE AX4 User manual

Siemens

Siemens SISTORE AX4 User manual

Siemens FDM273-O Guide

Siemens

Siemens FDM273-O Guide

Siemens FDM223-Ex User manual

Siemens

Siemens FDM223-Ex User manual

Popular Security System manuals by other brands

Polon-Alfa 4000 Installation and maintenance manual

Polon-Alfa

Polon-Alfa 4000 Installation and maintenance manual

Nexcom NViS 14162 Series user manual

Nexcom

Nexcom NViS 14162 Series user manual

Eminent EM8670 Quick install

Eminent

Eminent EM8670 Quick install

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

urmet domus

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

SmartPool YardGuard YG03 manual

SmartPool

SmartPool YardGuard YG03 manual

DSC PC5964 Mounting instructions

DSC

DSC PC5964 Mounting instructions

Secure USAB-1 operating instructions

Secure

Secure USAB-1 operating instructions

B&B 480 SERIES Operation & maintenance manual

B&B

B&B 480 SERIES Operation & maintenance manual

ADEMCO VISTA-20P Series Installation and setup guide

ADEMCO

ADEMCO VISTA-20P Series Installation and setup guide

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

FRIEDLAND MA10 Installation and operating instructions

FRIEDLAND

FRIEDLAND MA10 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

A6V10456393_enUS_c
Siemens Industry, Inc.
2016-06-16 Building Technologies Division
FT2009-U1 / FT2009-R1
LED Annunciator-32 Zone
Product Manual
Characteristic
l2 × 32 LEDs for 32 zones alarm/supervisory/trouble event display
lDisplay of system fault and ground fault from the entire system
lCommunication with panel through UFP (individual address)
lExternal 24V DC power source required from an UL listed/recognized for fire use,
regulated, power limited power supply
lIn total, up to 8 UFP type devices connected to a fire control panel
lManually activate / deactivate NAC’s
lAcknowledge and reset events from the entire system
lSelf test function
lFlat, elegant housing
UFP
FT2008
LampTest
Reset
Acknowledge
Silenced
Trouble
GroundFault
Power
FT2008-U1
AudiblesOn
LampTest
Reset
Acknowledge
Silenced
Trouble
GroundFault
Power
FT2008-U1
AudiblesOn
FT2009
24V DC
FT2007 built-in 24V DC 24V DC
firealarmresources.com
2
Siemens Industry, Inc. A6V10456393_enUS_c
Building Technologies Division 2016-06-16
LEDs & buttons & key switch
LEDs:
No. Color Status Functions
1Red /
Yellow
On Red: indicate alarm event or NAC activation event
from the zone.
Yellow: indicate supervisory event from the zone.
2Yellow On Indicate trouble event from the zone.
3Green On The LED annunciator power.
4Yellow On Indicate trouble event from the entire system.
Also indicate FT2009 communication failure.
(supervised at fire control panel).
5Yellow On Indicate ground fault event from the entire system.
6Red On Audibles are active.
7Yellow On Audibles are silenced.
8Yellow Flash Event waiting to be acknowledged.
Off All events are acknowledged.
9Yellow On The panel can be reset.
Off The panel is reset.
Buttons:
No. Button Functions
10 Audibles On /
Silenced
Silence / Un-silence the NAC’s in the event.
11 Acknowledge Acknowledge events.
12 Reset Resets the fire control panel to quiescent condition.
13 Lamp Test Test the LEDs and local buzzer.
Key switch: The key switch is used for control of button operation.
Lock key position Function
Buttons locked.
Buttons unlocked.
Lamp Test
Reset
Acknowledge
Silenced
Trouble
Ground Fault
Power
FT2009-U1
Audibles On
1
2
3
4
5
6
7
8
9
10
11
12
13
firealarmresources.com
3
Siemens Industry, Inc. A6V10456393_enUS_c
Building Technologies Division 2016-06-16
DIP switch & EOL jumper
S601 Dip-Switch for address setting
X209 EOL jumper for setting terminal resistor
X203 / X204 Connection to UFP, power supply and grounding
Dip-switch:
8-digit Dip-switch is used for the FT2009 address setting and baud rate setting. The
first 1-4 digits are for setting FT2009 address, the 7-8 digits are for setting UFP
communication baud rate. The 5 and 6 digits are reserved for future use.
Address
DIP switch
Baud Rate
DIP switch
1 2 3 4 7 8
1On Off Off Off 9600 bps Off Off
2 Off On Off Off 19200 bps On Off
3On On Off Off 38400 bps Off On
4Off Off On Off 57600 bps On On
5On Off On Off
6Off On On Off
7On On On Off
8Off Off Off On
Connect to fire control panel FC901/FC2005, 19200 bps is required.
EOL jumper: EOL jumper is used for setting terminal resistor of UFP.
Jumper IN Terminal resistor is connected.
Jump OUT Terminal resistor is not connected.
S601
X209 X203
X204
firealarmresources.com
Issued by
Siemens Industry, Inc.
Building Technology Division
8 Fernwood Road
Florham Park, NJ 08932
Tel. +1 973-593-2600
www.sbt.siemens.com/FIS
@2016 Siemens Industry, Inc.
Technical specifications and availability subject to change without notice.
Doc No. A6V10456393_enUS_c
Edition 2016-06-16
Dimensions
In: inch
Technical data
Operating voltage 24V DC Nominal / 18.8…27.2V DC
Operating current (quiescent) 25 mA
Activation current 105 mA
Operating temperature 32…120.2 °F
Storage temperature 14…+140 °F
Humidity ≤93 % rel.
Communication protocol UFP
Connection terminals 14…18 AWG
Color Black / Red
Operating location Indoor / dry
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may
cause undesired operation.
Details for ordering
Type Material No. Part No. Designation Weight
FT2009-U1 S54400-A145-A1 101592281 LED annunciator-32 Zone, black 3.748 lb
FT2009-R1 S54400-A146-A1 101592282 LED annunciator-32 Zone, red 3.748 lb
·For Canadian applications, the “FT2009-U1”/“FT2009-R1” is deemed supplementary and can be used for display
only. It must be housed in a ULC-S527 approved, locked, enclosure.
·Not approved for UL/ULC MNS applications.
11.417
7.362
1.949
firealarmresources.com