10
Name and Function of Parts
Front Panel
aRed tally light
Turns on when a red tally signal is received. When the CALL
button on the video camera, the MSU-1000 Master Setup Unit,
or the RCP-3000/1000 series Remote Control Panel is
pressed, the light turns off if lit or turns on if not lit.
A supplied number plate can be attached (see following
diagram).
bYellow tally light
Turns on when a yellow tally signal is received.
cGreen tally light
Turns on when a green tally signal is received.
dCCU number display
Displays the camera number specified in the menu of the CCU
for a system connection.
A number is not displayed when this unit is used as an
extension unit.
eMENU control block
DISP/MENU lever and indicator: Used to display the status
and menu. The indicator lights up when the menu is
displayed.
CANCEL/ENTER lever: Used to cancel/enter settings when
the menu is displayed.
Control knob (rotary encoder): Used to switch pages when
the status screen is displayed. Used to move the cursor
within a page and to change the setting of the selected
item when the menu is displayed.
Pushing the control knob has the same function as setting
the CANCEL/ENTER lever to ENTER.
fNETWORK Indicators
When the SKC-IP45AF (option) is installed: Displays the
status of NMI-LAN.
1: Corresponds to SLOT 1 NMI LAN 1 to 2.
2: Corresponds to SLOT 2 NMI LAN 1 to 2.
3: Corresponds to SLOT 3/4 NMI LAN 1 to 2.
Green: Normal state
Flashing green: Network synchronization process is in
progress.
Off: SFP+ module is not installed.
IP Live System Manager has been disconnected.
IP Live System Manager connection is being
established.
Flashing red: Not locked to network synchronization
signal. Signal reception is unavailable.
When the SKC-4001 (option) is installed: Displays the
status of network genlock.
Low-speed flashing: PTP master not detected
High-speed flashing: Genlock initiation in progress
On: Genlock state
Off: Network genlock setting disabled
gStatus display indicators
REF IN (green): Indicates operation is synchronized to
REFERENCE input signal.
UNLOCK (red): Indicates operation is not synchronized to
input reference signal.
When connected to a CCU, REF IN and UNLOCK indicate
the lock status for the CCU.
RCP/MSU: Displays the network system connection status.
On: Indicates that an external control device (MSU-1000
Master Setup Unit or RCP-3000/1000 series Remote
Control Panel) is connected when the CNS MODE
setting in <CNS SETTINGS> is set to BRIDGE.
Flashing: Indicates that an external control device (MSU-
1000 Master Setup Unit or RCP-3000/1000 series
Remote Control Panel) is not connected successfully
when the CNS MODE setting in <CNS SETTINGS> is
set to BRIDGE.
Off: Indicates that the LAN cable is not connected or
network system connection parameters have not been
set when the CNS MODE setting in <CNS
SETTINGS> is set to BRIDGE.
The indicator is always off when CNS MODE is set to
LEGACY.
POWER
CAM BPU CCU
MENU
ENTER
DISP
REF IN
UNLOCK
COM ERROR
RCP/MSU
FAN STOP
SW
MENU LOCK
OFF ON
CANCEL
NETWORK
231
OPTICAL
CONDITION
MENU
USB connector (for service personnel)
DISP/MENU lever and indicator
CANCEL/ENTER lever
Control knob