SUTO D554 0031 Manual

English
Instruction and operation manual
Current meter

Dear Customer,
thank you for choosing our product.
The operating instructions must be read in full and carefully observed
before starting up the device. The manufacturer cannot be held liable
for any damage which occurs as a result of non-observance or non-
compliance with this manual.
Should the device be tampered with in any manner other than a
procedure which is described and specified in the manual, the warranty
is cancelled and the manufacturer is e empt from liability.
The device is destined e clusively for the described application.
SUTO offers no guarantee for the suitability for any other purpose.
SUTO is also not liable for consequential damage resulting from the
delivery, capability or use of this device.
2 Current meter

Table of contents
1. Safety instructions.......................................................................4
2. Application.................................................................................6
3. Features.....................................................................................6
4. Technical Data............................................................................6
4.1 General.................................................................................6
4.2 Electrical Data........................................................................6
4.3 Input-Signals.........................................................................6
4.4 Output-Signals.......................................................................6
4.5 Accuracy...............................................................................7
5. Installation ................................................................................7
5.1 Installation Procedure ............................................................7
5.2 Electrical connection .............................................................8
6. Modbus output ...........................................................................9
7. Disposal or waste......................................................................10
8. Warranty..................................................................................10
Current meter 3

1. Safety instructions
1. Safety instructions
Please check if this instruction manual accords to the
product type.
Please observe all notes and instructions indicated in this
manual. It contains essential information which have to be
observed before and during installation, operation and
maintenance. Therefore this instruction manual has to be read carefully
by the technician as well as by the responsible user / qualified
personnel.
This instruction manual has to be available at the operation site of the
device at any time. In case of any obscurities or questions, regarding
this manual or the product, please contact the manufacturer.
WARNIN !
Voltage used for supply!
Any contact with energized parts of the product, may
lead to a electrical shock which can lead to serious
injuries or even death!
•Consider all regulations for electrical installations.
•The system must be disconnected from any power supply during
maintenance work.
•Any electrical work on the system is only allowed by authorized
qualified personal.
WARNIN !
Permitted operating parameters!
Observe the permitted operating parameters, any
operation exceeding this parameters can lead to
malfunctions and may lead to damage on the
instrument or the system.
•Do not e ceed the permitted operating parameters.
•Make sure the product is operated in its permitted limitations.
•Do not e ceed or undercut the permitted storage and operation
temperature and pressure.
•The product should be maintained frequently, at least annually.
eneral safety instructions
4 Current meter

1. Safety instructions
•It is not allowed to use the product in e plosive areas.
•Please observe the national regulations before/during installation
and operation.
Remarks
•It is not allowed to disassemble the product.
•Always use spanner to mount the product properly.
ATTENTION!
Measurement values can be affected by malfunction!
The product must be installed properly and
frequently maintained, otherwise it may lead to
wrong measurement values, which can lead to
wrong results.
Storage and transportation
•Make sure that the transportation temperature of the device is
between -30°C... 70°C.
•For transportation it is recommended to use the packaging which
comes with the device.
•Please make sure that the storage temperature of the device is
between -30°C... 75°C.
•Avoid direct UV and solar radiation during storage.
•For the storage the humidity has to be < 95%, no condensation.
Current meter 5

2. Application
2. Application
The current meter is designed to measure 4... 20 mA signals within the
permissible operating parameters. These parameters can be found in
the technical data section.
The current meter is not developed to be used in e plosive areas. For
the use in e plosive areas please contact the manufacturer.
The current meter is mainly used in compressed air systems in
industrial environment.
3. Features
•Built-in resistor to simplify current measurement.
•Open wire detection for 4... 20 mA input.
•Wide operation temperature rage: -25°C... 75°C.
•provide modbus RTU interface.
4. Technical Data
4.1 eneral
Operating temperature -25°C... 75°C
Operating humidity ≤ 95 % (no condensation)
Dimensions 72 mm 123 mm 35 mm
Weight 150 g
4.2 Electrical Data
Power supply 10... 30 V DC, 1.3 W
4.3 Input-Signals
Analog input 8 4... 20 mA
4.4 Output-Signals
Interface RS-485 Modbus
6 Current meter

4. Technical Data
4.5 Accuracy
Accuracy ± 0.1 % (normal), ± 0.5 % (fast)
5. Installation
Please make sure that all components listed below are included in your
package.
Qty Description Item No.
1 Current meter D554 0031
1 Instruction manual No P/N
5.1 Installation Procedure
Installation of the current meter
DIN rail mounting
Current meter 7

6. Modbus output
Inde Channel description Format Length Modbus
address
1 Channel1 INT16 2 Byte 0
2 Channel2 INT16 2 Byte 1
3 Channel3 INT16 2 Byte 2
4 Channel4 INT16 2 Byte 3
5 Channel5 INT16 2 Byte 4
6 Channel6 INT16 2 Byte 5
7 Channel7 INT16 2 Byte 6
8 Channel8 INT16 2 Byte 7
Remark
•Function code: 4
7. Disposal or waste
Electronic devices are recyclable material and do not belong in the
household waste.
The device, the accessories and its packings must be disposed
according to your local statutory requirements. The dispose can also be
carried by the manufacturer of the product, for this please contact the
manufacturer.
8. Warranty
SUTO provides a warranty for this product of 24 months covering the
material and workmanship under the stated operating conditions from
the date of delivery. Please report any findings immediately and within
the warranty time. If faults occurring during the warranty time SUTO
will repair or replace the defective unit, without charge for labour and
material costs but there is a charge for other service such as transport
and packing costs.
E cluded from this warranty is:
•Damage caused by:
◦Improper use and non-adherence to the instruction manual.
◦Use of unsuitable accessories.
◦E ternal influences (e.g. damage caused by vibration, damage
10 Current meter

8. Warranty
during transportation, e cess heat or moisture).
The warranty is cancelled:
•If the user opens the measurement instrument without a direct
request written in this instruction manual.
•If repairs or modifications are undertaken by third parties or
unauthorised persons.
•If the serial number has been changed, damaged or removed.
Other claims, especially those for damage occurring outside the
instrument are not included unless responsibility is legally binding.
Warranty repairs do not e tend the period of warranty.
ATTENTION!
Batteries have a reduced warranty time of 12
month.
Current meter 11

SUTO iTEC GmbH SUTO iTEC Co., Ltd.
Werkstr. 2 Room 10, 6/F, Block B, Cambridge Plaza
79426 Buggingen 188 San Wan Road, Sheung Shui, N.T.
Germany Hong Kong
Tel: +49 (0) 7631 936889-0 Tel: +852 2328 9782
Fa : +49 (0) 7631 936889-19 Fa : +852 2542 1310
Website: http://www.suto-itec.com Website: http://www.suto-itec.com
All rights reserved © Modifications and errors reserved.
current_meter_im_en_2017-2
12 Current meter
Table of contents
Other SUTO Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Pivitec
Pivitec E16i quick start guide

Laser Technology
Laser Technology TruPulse 200L user manual

Knick
Knick Stratos Pro A2 COND Series quick start guide

ETS-Lindgren
ETS-Lindgren HI-1801 user manual

PCB Piezotronics
PCB Piezotronics 340A75 Installation and operating manual

PCE Instruments
PCE Instruments PCE-DFG X Series quick start guide