Product information
Indoor station for hands-free talking
ISW3030

2 07/2015
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Table of content
Scope of delivery...............................................................................................................3
Safety instructions.............................................................................................................3
Installation –protection measures....................................................................................3
Intended use.......................................................................................................................3
Max. number ISW3030 in 2-wire operation......................................................................3
Max. number ISW3030 in 3-wire operation......................................................................4
Indication and operating elements...................................................................................4
Device overview.................................................................................................................5
Technical data....................................................................................................................5
Short description...............................................................................................................6
Installation..........................................................................................................................6
Installation site .................................................................................................................6
Install the lower cover.......................................................................................................6
Connect the lines (2-wire technique)................................................................................7
Snapping-on the upper cover...........................................................................................7
Open the device...............................................................................................................7
Installation of extended functions.....................................................................................8
Connecting the lines..........................................................................................................8
Connecting lines...............................................................................................................8
Wiring diagram.................................................................................................................9
Connection diagram 2-wire technique..............................................................................9
Connection diagram 3-wire technique..............................................................................9
Commissioning................................................................................................................10
Settings.............................................................................................................................10
Pre-adjusted times .........................................................................................................10
2-wire/3-wire opration.....................................................................................................10
Ring tone selection.........................................................................................................11
Adjust volumes...............................................................................................................11
Configuration options .....................................................................................................12
Programming with the Service Device TCSK-01............................................................12
General information on the conduit in TCS audio systems.........................................12
Principle loop resistance.............................................................................................13
Measurement loop resistance.....................................................................................13
Repair................................................................................................................................14
Error detection and indication.........................................................................................14
Exchange of an indoor station –programming bell buttons............................................14
Cleaning............................................................................................................................15
Conformity........................................................................................................................16
Information on disposal ..................................................................................................16
Warranty...........................................................................................................................16
Service..............................................................................................................................16

07/2015 3
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Scope of delivery
1 x indoor station ISW3030: upper cover, lover cover
product information
instruction manual
Safety instructions
!
Notice! Mounting, installation, commissioning and repair of electrical devices have to
be carried out only by qualified eletricians! Thus the in standards and rules for the in-
stallation of systems must be observed!
When installing TCS:BUS systems the general safety regulations for telecommunication
systems after VDE 0800 must be observed. Inter alia:
separated guidance of heavy and low current lines,
minimum distance of 10 cm in case of common cable routing,
use of separator between heavy and low current lines in case of cable channels which
are used in common,
use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
already existing lines (modernisation) with differing cross sections can be used with
considering the loop resistance.
Installation –protection measures
!
By suitable requirements to protect against lightning it is imperative that the electric
tension of each 32 V DC is not exceeded at the connections a, b, P, E.
Intended use
ISW3030 are indoor stations for hands-free talking for the object area.
They can be used for the operation within TCS audio systems and combined audio /
video systems.
They are suitable for surface-mount.
Max. number ISW3030 in 2-wire operation
In case of using powers
supply and control unit
max. number
ISW3030
BVS20 or
NBV1000, 1 line
20
BVS100,
distributed on 3 lines
80
VBVS05, 1 line
30

4 07/2015
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Max. number ISW3030 in 3-wire operation
in case of using power
supply and control unit
Max. Anzahl
ISH3030
BVS20 or
NBV1000, 1 line
20
BVS100,
distributed on 3 lines
80
VBVS05, 1 line
90
BVS20 + NGV1011,
1 line
90
AS front-door station
VS power supply and control unit
IS indoor station
note: The max. number of front-door stations which
can be connected is limited. Details are described in
their product information!
BVS100 + NGV1011,
3 lines
270
Indication and operating elements
speech button
accepting a call, activate communication,
manually controlled duplex communication
end communication
call OFF button
press short: ring tone stopper
press for 8 sec: initiate ring tone selection
display call OFF
(red)
ON: call OFF is activated
error indication: both LEDs are flashing
ring tone selection: both LEDs are ON
○
control key
control function 8
ring tone selection internal call
Call display (green)
ON: call, communication is activated
Blinks 3 x: speech channel is busy
error indication: both LEDs are flashing
ring tone selection: both LEDs are ON
light switch button
switching lights
ring tone selection floor call (from the flat door)
door release button
open the door
trigger light switch function*
ring tone selection door call from front-door station
volume control for
voice output
ring tone
adjustable in 8 steps:
when voice communication is established
when no voice communication is established
* if light switch function is activated in the front.door station

07/2015 5
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Device overview
Technical data
supply voltage: +24 V ±8 % (power supply and control unit)
housing: plastics (colors as listed in catalogue)
dimensions (in mm): H 180 x W 100 x D 23
weight 185 g
acceptable ambient temperature: -5 ...+ 40 °C
degree of protection: IP30
input current stand-by 2-wire operation: I(a) = 1 mA
3-wire operation: I(a) = 0.2 mA, I(P) = 0.8 mA
max. input current: I(Pmax) = 75 mA
microphone
call display (green)
display call OFF (red)
call OFF button
light switch button
control key
loudspeaker
door release button
volume control
speech button

6 07/2015
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Short description
hands-free talking, manually controlled duplex communication can be activated
large, deteched, blue door release button
large speech button
light switch button
control key (ex works with control function 8)
call OFF-button for ring tone mute with optical display
optical display of door calls via LED (green)
optical display of a busy line when voice communication is established (LED green)
ring tones can be adjusted by the resident, selection of 13 ring tones in improved quality
voice volume and ring tone volume can be adjusted manually
acoustic call distinction between 2 front-door stations (via configuration software con-
figo™), flat door (floor door) and internal call
one parallel call can be activated (via Service Device TCSK-01 or configo™)
audio privacy function and automatic call cut-off (after 2 min)
lower cover with plugged-in screw terminal can be pre-installed and equipped alterna-
tively with a door telephone
optical and acoustic error indication
can be functional extended by mounting place for call relays and a radio signal device
can be activated/controlled
energy efficient with a low standby consumption of only 0.025 W
automatic hands-free talking (call acceptance) after internal call can be activated / deac-
tivated
Installation
Installation site
The indoor station is to be installed with a guar-
anteed minimum distance to walls or other ob-
stacles:
aside 5 cm and below 10 cm.
Install the lower cover
For placing the connection cables without
any problems, a flush-mounted socket must
be installed behind the device.
Position the flush-mounted socket below the
cable conduit.
Install the lower cover with three screws.
TIPP: Avoid tearing of the straps:
For fixing the straps do not use counter-head screws or
flat washers!

07/2015 7
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Connect the lines (2-wire technique)
Minimize the length of the lines above the
lower cover to place the lines without any
problems and do not clamp the lines when
snapping-on the upper cover.
Connect the lines according to the label-
ling: a b E P (from the bottom to the top),
floor push button at a –E.
See wiring diagram on page 9.
Snapping-on the upper cover
Set on the upper cover at both adjustment
increment of the lower cover (1).
Snap-in the upper cover below with slight
pressure (2)
Open the device
There is a rectangular release opening at the underside
of the device. Insert a small screwdriver straight and
with slight pressure into this opening.
The upper cover can be removed at the underside (1).
Lift the upper cover out of the two upper adjustment
increments (2).
1
2
1
2
floor push button

8 07/2015
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Installation of extended functions
TRE1
radio transmitter board
FFS3100
The extended functions (and the antenna) have to be fixed with adhesive pads in the
indoor station (see also product information of the corresponding extended function).
Connecting the lines
Connecting lines
permitted cross-section (diameter)
0.08 … 0.82 mm2(Ø 0.32 … 1.0 mm)
max. number of wires per terminal contact
each 2 x 0.8 mm, 3 x 0.6 mm
!
Further wires have to be connected via auxiliar terminals!
!
Use only connecting lines with the same diameter in one terminal contact.

07/2015 9
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Wiring diagram
Connection diagram 2-wire technique
Connection diagram 3-wire technique

10 07/2015
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Commissioning
Install the devices of the system voltage-free and completely.
Proof the a-, b- and P-wire against each other on short-circuit.
Switch on the main voltage.
Hint:
If the floor push button is not working, proof, if it is connected to the a-wire of the power
supply and control unit.
Settings
Pre-adjusted times
communication time
max. 2 min
flashing period of the green LED, if the voice
channel is busy after the voice communication
is established
2 sec
3 x flashing
internal standby time, if the device is calling or
is called
around
30 sec
2-wire/3-wire opration
The jumper J1 is adjusted for the 2-wire
operation in delivered state.
2-wire operation (delivered state)
Put the jumper J1 at both contacts for the
3-wire operation.
3-wire operation
J1

07/2015 11
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Ring tone selection
For 4 different incoming calls (door calls from 2 front-door stations, floor call, internal call)
the ring tones can be chosen.
1
End voice communication. Press call OFF button for around 8 sec.
Both LEDs are ON and an acknowledgement tone sounds, the ring tone selection
is activated.
By pressing the following buttons a ring tone can be selected. You can chose be-
tween 13 tones.
2a
select door ring tone
of the front-door sta-
tion*
Press the door release button as often as the required ring
tone sounds. The ring tone selected last, will be stored.
2b
select door ring tone
of the floor door
Press the light switch button as often as the required ring
tone sounds. The ring tone selected last, will be stored.
2c
select internal call to-
ne
Press the control key as often as the required ring tone
sounds. The ring tone selected last, will be stored.
3
Press call OFF button short.
In case that no button is pressed for around. 8 sec, the device ends the ring tone
selection automatically. Both LEDs go out and an acknowledgement tone sounds,
the ring tone selection is deactivated.
* The ring tone is identical for all front-door stations and can be selected only identically for all.
To select a second ring tone it is necessary to activate the call distinction by changing the audio AS limit.
Changing the audio AS limit is only possible with the configuration software configo™.
Adjust volumes
Each adjustable in 8 steps
volume of voice
Turn ring tone volume control when a voice communication is es-
tablished (adjustment ex works: volume step 4 from 8)
volume ring tone
Turn the ring tone volume control when there is no voice connec-
tion (adjustment ex works: volume step 6 from 8)
A signal tone is reflecting the adjusted volume when turning the volume control of the
ring tone.
If the setting is finished, the adjusted ring tone will be reflected in the adjusted volume.

12 07/2015
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Configuration options
function
manually
TCSK-01
configoTM
from version 1.3.3
ring tone volume
x
–
-
voice volume
x
–
-
selecting ring tones for door calls,
internal calls and floor calls
x
–
x
ring tone for door call 2
–
–
x
parallel allocation
–
x
x
change audio AS border
–
–
x
block ring tone output
x
–
–
block ring tone selection
x
reset to factory settings
–
–
x
Programming with the Service Device TCSK-01
The indoor station is acting like a device for manually controlled duplex communication.
Use the commands „8“ for configuring (see product information Service Device TCSK-
01).
Ser. no. = the serial number of the new indoor station that should be configured
ParSNo.= the serial number of the indoor station, to which the new configured indoor station is allocated
General information on the conduit in TCS audio systems
The conduit is determined by structural conditions and is only limited by its length
.
Note when choosing the cables: the loop re-
sistance can amount max. 20 Ω(table)
In compliance to the max. permitted loop re-
sistance the wire cross-section can be doubled,
that means, that for one wire two lines can be
used (illustration). The lines have to be twisted.
In case of using shielded cables: connect the
shielding with each other and put i tone-sided on
mass (b-wire) in the power supply
Optional strand or star formed wiring

07/2015 13
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Table: loop resistances
cable length in m
cable diameter
0.6 mm
0.8 mm
loop resistance in Ω
10
1.28
0.71
20
2.55
1.43
30
3.83
2.14
40
5.10
2.86
50
6.38
3.57
60
7.65
4.29
70
8.93
5.00
80
10.20
5.71
90
11.48
6.43
100
12.76
7.14
150
19.13
10.71
200
25.51
14.29
250
17.86
300
21.43
Principle loop resistance
Measurement loop resistance
None of the devices (AS, IS or FE) should never be
located more than 20 Ohm away from the power
supply and control unit (VS).
Switch off the 230 V / 50 Hz of the VS.
Install the a-b short-circuit at VS.
Other devices do not disturb the measurement,
they can be connected.
Measure the resistance at a/b of the last IS or
AS.
20 Ohm:
max. 160 m distance AS/IS-VS by 0.6 mm diameter
max. 300 m distance AS/IS-VS by 0.8 mm diameter
AS front-door station
VS power supply and control unit
IS indoor station
FE extended function
a, b short-
circuit here

14 07/2015
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Repair
Error detection and indication
Errors will be indicated optical and acoustic: error tone for one time and constant flashing
of the operation indication. When pressing any button, the error tone sounds again. The
optical error indication stays active until the error is resolved.
error causes
display
error
mode
error tone
elimintaion
a- and P-wire interchanged
or short-circuited
both
LEDs
are
flashing
change a- and P-wire or eliminate short-circuit,
device is going into sleep mode again
a-wire: not connected or
not supplied
connect the a-wire or proof power supply,
device is going into sleep mode again
Button stucks
(press longer than 15 sec)
remove button at the device or floor push button,
device is going into sleep mode again
Exchange of an indoor station –programming bell buttons
Basic principle
All devices at the TCS:BUS have got an unique serial number.
Programming a bell button means that the serial number of an indoor station is allocat-
ed to the bell button of a front-door station and is stored within the EEPROM of the
front-door station.
Ensure that the new indoor station is connected to the TCS:BUS and the mains voltage
is switched on (the operation LED at the power supply and control unit is ON) and fur-
ther, that the access to the flat is granted during the programming.
This instruction describes the case that a serial number is allocated to a bell button and
no programming lock is set. To deactivate a programming lock you need a Service De-
vice TCSK-01or the configuration software configo™.
1
Initiate
power supply and control unit
press shortly LED blinks
Programming mode of the system is ON

07/2015 15
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
2
Delete a buttona)
Press until the delete melody sounds 1)
release
3
Programming via voice communication
or
establish voice communication
to the front-door station 2)
press button shortly.
... until a ring tone sounds at the front-
door and indoor station 1)
4
End programming
press shortly LED is ON
Programming of the system is OFF *)
a) Not necessary, if the bell buttons have not been programmed, cf. product information of the front-door station.
1) If there sounds a Progsperr tone instead, the front-door station got a programming lock.
The programming lock can be deactivated only with the Service Device TCSK-01 or the configuration software
configo™.
2) New developed front-door stations (from 2009 on)respond to that with positive acknowledgement, if the serial number
of the indoor station was received (see product information of the front-door station).
*) device specific indication modes of the front-door station see product information of the font-door station
Cleaning
!
Avoid water from entering the device!
Do not use any abrasive detergents!
Clean the device with a dry or slightly wet cloth.
Remove stronger stains with a standard plastic cleaner.

16 07/2015
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes.
Mail: hotline@tcsag.de ISW3030-0140 UK 2 A
Conformity
Download the declarations of conformity from www.tcsag.de, Downloads, trade in-
formation.
Information on disposal
The adjoining symbol shows that the device has to be disposed separately from
domestic waste. The materials used are recyclable. Please do help protecting our
environment and dispose the device via a collection point for electronic scrap.
Dispose the parts of the packaging in collecting tanks for cardboard and paper
resp. plastics.
Warranty
We offer a simplified processing in case of warranty for electrician.
Note our conditions of sale and delivery, a www.tcsag.de, Downloads, trade infor-
mation and also included in our actually price list.
Please contact us: [email protected].
Service
Please send your questions and inquiries to
headquarters
TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, 39307 Genthin | Germany
Tel.: +49 (0) 3933/879910, FAX: +49 (0) 3933/879911, www.tcsag.de
Table of contents
Other TCS Intercom System manuals

TCS
TCS ISW3330 User manual

TCS
TCS Tasta Series Instruction manual

TCS
TCS IVH4222-0140 User manual

TCS
TCS Carus Origo User manual

TCS
TCS ISH3022 User manual

TCS
TCS CAI2002-0140 User manual

TCS
TCS IVW3012-0110 User manual

TCS
TCS AMI Series User manual

TCS
TCS ISW3230-0140 User manual

TCS
TCS SKYLINE:TEN BASIC User manual

TCS
TCS AMI1090 Series User manual

TCS
TCS AMI Series User manual

TCS
TCS IMM2500 User manual

TCS
TCS ECOOS:FIVE User manual

TCS
TCS Carus Origo CAI2010 User manual

TCS
TCS ISH3030-0140 User manual

TCS
TCS AVD Series User manual

TCS
TCS SKYLINE:TEN BASIC User manual

TCS
TCS PUK Series User manual

TCS
TCS AVC11010-0010 User manual