manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. teko
  6. •
  7. Security Sensor
  8. •
  9. teko Astra-531 PIR Installation instructions

teko Astra-531 PIR Installation instructions

Other teko Security Sensor manuals

teko Astra-531 Ver.PIR User manual

teko

teko Astra-531 Ver.PIR User manual

teko Astra-551 User manual

teko

teko Astra-551 User manual

teko Astra-621 User manual

teko

teko Astra-621 User manual

teko Astra-5131 User manual

teko

teko Astra-5131 User manual

teko Astra-531 AC Installation instructions

teko

teko Astra-531 AC Installation instructions

teko Astra-R TRC User manual

teko

teko Astra-R TRC User manual

teko Astra-642 User manual

teko

teko Astra-642 User manual

teko Astra-531 DC Installation instructions

teko

teko Astra-531 DC Installation instructions

teko Astra-3321 User manual

teko

teko Astra-3321 User manual

teko Astra-612 User manual

teko

teko Astra-612 User manual

teko Astra-9 User manual

teko

teko Astra-9 User manual

teko Astra-9 Installation instructions

teko

teko Astra-9 Installation instructions

teko Astra-5 Ver.A User manual

teko

teko Astra-5 Ver.A User manual

teko Astra-361 Installation instructions

teko

teko Astra-361 Installation instructions

teko Astra-517 ver.P User manual

teko

teko Astra-517 ver.P User manual

teko Astra-551 User manual

teko

teko Astra-551 User manual

teko Astra-7 ver.A User manual

teko

teko Astra-7 ver.A User manual

teko Astra-5131 User manual

teko

teko Astra-5131 User manual

teko Astra-GB Installation instructions

teko

teko Astra-GB Installation instructions

teko Astra-43A User manual

teko

teko Astra-43A User manual

teko Astra-3731 User manual

teko

teko Astra-3731 User manual

teko Astra-621 RF User manual

teko

teko Astra-621 RF User manual

teko Astra-A ILS User manual

teko

teko Astra-A ILS User manual

teko Astra-5131 User manual

teko

teko Astra-5131 User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Astra-531 Ver.PIR
(Surface Lens)
Optic-Electronic PIR Motion
Detector
User Instruction*
Sales:
Controlex GmbH
Philosophenweg 31-33
47051 Duisburg,Germany
+49 (0) 203/393 91 188
info@controlex.eu
www.controlex.eu
Warranty service and
technical support:
TEKO-TD
Prospekt Pobedy str. 19
420138 Kazan, Russia
+7(843) 261-55-75
[email protected]z
www.teko.biz
Made in Russia
Rev. 531-ikv1_0_instr_EN
1 FUNCTION
Detector is intended to detect unauthorized
access into closed protected area, and to
generate an alarm notification by opening of
signaling relay contacts.
2 DETECTION ZONE
3 SPECIFICATIONS
Range of detected
moving speed, m/s.................from 0,3 up to 3,0
Power supply voltage, V.............from 8 up to 15
Current consumption, mA, max......................18
Overall dimensions, mm.....................62×37×29
Operating Conditions
Temperature range, °С..............от - 20 до + 50
Relative air humidity, %...........up to 95 at + 35 °С
Withoutmoisturecondensation
4 DELIVERY SET
Delivery set contains holders and fasteners
(bracket - 1pcs., dowel –2 pcs., screw –2
pcs.), jumper –2 pcs.
5 OPERATING MODE
Operating mode
Plug
name
Jumper
position
High detectability
of PIR-channel
Normal
detectability
of PIR-channel
PIR
“Alarm memory”
ON
“Alarm memory”
OFF
Mem
TEST-pass
-
See par. 9
6 INSTALLATION LOCATION
1) Recommended installation height is 5 m max.
2) Installation on ceiling, on a wall, in window
openings and between window frames is al-
lowed.
3) Alarm loop and power supply wires should
be located far from power cables.
To eliminate false alarm hazards
It is recommended to close all doors, air-vents,
switch off fans, air-conditioners and other
sources of intense air flows in the room during
protection period.
Not recommended installation locations
7 INSTALLATION PROCEDURE
1) Remove cover
2) Remove PCB
3a) Installation on the
wall
3b) Installation using
bracket
Detector base should be positioned strictly
as per figure!
4) Replace PCB and
perform wiring
(see par.8)
5) Perform TEST-pass
(see par.9)
8 WIRING
Perform wiring to detector`s terminals in
accordance with control panel operating
manual.
RELAY –terminals for detector connection to
alarm loop;
TMP –detector tampering control terminals;
GND, +12V –power supply terminals.
9 TEST-PASS
1) Remove jumpers from PIR and Mem plugs.
2) Power detector ON. LED starts flash during
60 sec.
3) Close detector.
4) To detect sensitive zones carry out TEST-
pass in the secured zone with the speed of 0,3
and 3 m/s.
On detection (indicator is lighted for 2s) one
should stop, mark this position, then make step
back and continue moving. Repeat TEST-pass
inversely.
10 WARRANTY
The operation warranty period is 5 years from the date
of operation start-up but no longer than 5 years 6
months from the date of manufacturing subject to the
requirements of Operating Manual.
*For more detailed information refer to detector
Operating Manual available for free from
www.controlex.eu.
Hooks