Trix H0 45 Series User manual

Modell der Güterzug-Dampflokomotive Baureihe 45
22946
F
D GB USA NL

2

3
Inhaltsverzeichnis Seite
Sicherheitshinweise 4
Wichtige Hinweise 4
Multiprotokollbetrieb 4
Schaltbare Funktionen 7
Parameter/Register 8
Betriebshinweise 24
Ergänzendes Zubehör 26
Wartung und Instandhaltung 28
Ersatzteile 32
Table of Contents Page
Safety Notes 9
Important Notes 9
Multi-Protocol Operation 9
Controllable Functions 12
Parameter/Register 13
Information about operation 24
Complementary accessories 26
Service and maintenance 28
Spare Parts 32
Sommaire Page
Remarques importantes sur la sécurité 14
Information importante 14
Mode multiprotocole 14
Fonctions commutables 17
Paramètre/Registre 18
Remarques sur l’exploitation 25
Accessoires complémentaires 26
Entretien et maintien 28
Pièces de rechange 32
Inhoudsopgave Pagina
Veiligheidsvoorschriften 19
Belangrijke aanwijzing 19
Multiprotocolbedrijf 19
Schakelbare functies 22
Parameter/Register 23
Opmerkingen over de werking 25
Aanvullende toebehoren 26
Onderhoud en handhaving 28
Onderdelen 32

4
Sicherheitshinweise
• DieLokdarfnurmiteinemdafürbestimmtenBetriebssys-
tem eingesetzt werden.
• Analogmax.15Volt=,digitalmax.22Volt~.
• DieLokdarfnurauseinerLeistungsquelleversorgt
werden.
• BeachtenSieunbedingtdieSicherheitshinweiseinder
Bedienungsanleitung zu Ihrem Betriebssystem.
• FürdenkonventionellenBetriebderLokmussdasAn-
schlussgleis entstört werden. Dazu ist das Entstörset
611 655 zu verwenden. Für Digitalbetrieb ist das Entstör-
set nicht geeignet.
• ACHTUNG! Funktionsbedingte scharfe Kanten und Spitzen.
• SetzenSiedasModellkeinerdirektenSonneneinstrah-
lung,starkenTemperaturschwankungenoderhoher
Luftfeuchtigkeitaus.
• VerbauteLED`sentsprechenderLaserklasse1nach
Norm EN 60825-1.
Wichtige Hinweise
• DieBedienungsanleitungunddieVerpackungsind
Bestandteile des Produktes und müssen deshalb aufbe-
wahrt sowie bei Weitergabe des Produktes mitgegeben
werden.
• FürReparaturenoderErsatzteilewendenSiesichbittean
IhrenTrix-Fachhändler.
• GewährleistungundGarantiegemäßderbeiliegenden
Garantieurkunde.
• Entsorgung:www.maerklin.com/en/imprint.html
• DervolleFunktionsumfangistnurunterDCCundunter
mfx verfügbar.
• Eingebaute,fahrtrichtungsabhängigeStirnbeleuchtung.
Im Digitalbetrieb schaltbar.
• Rauchsatznachrüstbar-auchfürdenAnalogbetrieb.
• ImAnalogbetriebstehennurdieRauch-,Fahr-undLicht-
wechselfunktionen zur Verfügung.
• BefahrbarerMindestradius360mm.
Multiprotokollbetrieb
Analogbetrieb
Der Decoder kann auch auf analogen Anlagen oder Gleis-
abschnitten betrieben werden. Der Decoder erkennt die
analoge Gleichspannung (DC) automatisch und passt sich
deranalogenGleisspannungan.EssindalleFunktionen,
die unter mfx oder DCC für den Analogbetrieb eingestellt
wurden aktiv (siehe Digitalbetrieb).
Digitalbetrieb
Der Decoder ist ein Multiprotokolldecoder. Der Decoder
kannunterfolgendenDigital-Protokolleneingesetztwerden:
mfx,DCCoderMM.
AdresseabWerk:DCC 03 / MM 45
Das Digital-Protokoll mit den meisten Möglichkeiten ist das
höchstwertige Digital-Protokoll. Die Reihenfolge der Digital-
ProtokolleistinderWertungfallend:
Priorität1:mfx
Priorität2:DCC
Priorität3:MM

5
Hinweis: Werden zwei oder mehrere Digital-Protokolle am
Gleiserkannt,übernimmtderDecoderautomatischdas
höchstwertige Digital-Protokoll; z.B. wird mfx & DCC erkannt
wird das mfx-Digital-Protokoll vom Decoder übernommen.
Einzelne Protokolle können über den Parameter CV 50
deaktiviert werden.
Hinweis:BeachtenSie,dassnichtalleFunktioneninallen
Digital-Protokollen möglich sind. Unter mfx und DCC können
einigeEinstellungenvonFunktionen,welcheimAnalog-
Betriebwirksamseinsollen,vorgenommenwerden.
Hinweise zum Digitalbetrieb
• DiegenaueVorgehensweisezumEinstellenderdiversen
Parameter entnehmen Sie bitte der Bedienungsanleitung
Ihrer Mehrzug-Zentrale.
• DerBetriebmitgegenpoligerGleichspannungim
Bremsabschnitt ist mit der werkseitigen Einstellung
nichtmöglich.IstdieseEigenschaftgewünscht,somuss
auf den konventionellen Gleichstrombetrieb verzichtet
werden(CV29/Bit2=0).
mfx-Protokoll
Adressierung
• KeineAdresseerforderlich,jederDecodererhälteine
einmalige und eindeutige Kennung (UID).
• DerDecodermeldetsichaneinerCentralStationoder
Mobile Station mit seiner UID automatisch an.
• NameabWerk:45 022 DB
Programmierung
• DieEigenschaftenkönnenüberdiegrascheOberäche
der Central Station bzw. teilweise auch mit der Mobile
Station programmiert werden.
• EskönnenalleCongurationVariablen(CV)mehrfach
gelesen und programmiert werden.
• DieProgrammierungkannentwederaufdemHaupt-oder
dem Programmiergleis erfolgen.
• DieDefaulteinstellungen(Werkseinstellungen)können
wieder hergestellt werden.
• Funktionsmapping:FunktionenkönnenmitHilfeder
Central Station 60212 (eingeschränkt) und mit der Central
Station 60213/60214/60215/60216/60226 beliebigen Funkti-
onstasten zugeordnet werden (siehe Hilfe in der Central
Station).

6
DCC-Protokoll
Adressierung
• MöglicheAdressen:Kurze,langeundTraktionsadresse
• Adressbereich:
1–127(kurzeAdresse,Traktionsadresse)
1 – 10239 (lange Adresse)
• JedeAdresseistmanuellprogrammierbar.
• KurzeoderlangeAdressewirdüberdieCVsausgewählt.
• EineangewandteTraktionsadressedeaktiviertdie
Standard-Adresse.
Programmierung
• DieEigenschaftenkönnenüberdieCongurationsVari-
ablen (CV) mehrfach geändert werden.
• DieCV-NummerunddieCV-Wertewerdendirekteinge-
geben.
• DieCVskönnenmehrfachgelesenundprogrammiert
werden (Programmierung auf dem Programmiergleis).
• DieCVskönnenbeliebigprogrammiertwerden.PoM
(Programmierung auf dem Hauptgleis PoM) ist nur bei
deninderCV-TabellegekennzeichnetenCVmöglich.
PoM muss von Ihrer Zentrale unterstützt werden (siehe
Bedienungsanleitung ihres Gerätes).
• DieDefaulteinstellungen(Werkseinstellungen)können
wieder hergestellt werden.
• 14bzw.28/126Fahrstufeneinstellbar.
• AlleFunktionenkönnenentsprechenddemFunktions-
mapping geschaltet werden.
• WeitereInformation,sieheCV-TabelleDCC-Protokoll.
Eswirdempfohlen,dieProgrammierungengrundsätzlichauf
dem Programmiergleis vorzunehmen.
Logische Funktionen
Anfahr-/Bremsverzögerung
• DieBeschleunigungs-undBremszeitkönnengetrennt
von einander eingestellt werden.
• DielogischeFunktionsabschaltungABVkannüberdas
Funktionsmapping auf jede beliebige Funktionstaste
gelegt werden.

7
Schaltbare Funktionen
DC/AC
MS I 1
MS II
CS I
CS II/III
Geräusch:Schienenstöße F16
Geräusch:Bahnhofsansage F17
Geräusch:Kohlefassen F18
Geräusch:Wassernachfüllen F19
Geräusch:Sanden F20
Geräusch:Führerstandsgespräch F21
Rangiergang F22
Funktionsabfolge:Heizer F23
Schaltbare Funktionen
DC/AC
MS I 1
MS II
CS I
CS II/III
Spitzensignal F0
Rauchgenerator 2F1
Betriebsgeräusch F2
Geräusch:Pfeifelang F3
ABV,aus F4
Geräusch:Bremsenquietschenaus F5
Führerstandsbeleuchtung F6
Geräusch:Rangierpff F7
Feuerschein - Feuerbüchse F8
Geräusch:Dampfablassen F9
Geräusch:Kohleschaufeln F10
Geräusch:Schüttelrost F11
Geräusch:Luftpumpe F12
Geräusch:Injektor F13
Geräusch:Wasserpumpe F14
1 TrixSystems
2 GehörtnichtzumLieferumfang.

8
CV Bedeutung Wert DCC ab Werk
1 Adresse 1 - 127 3
2 PoM Minimalgeschwindigkeit 0 - 255 5
3 PoM Anfahrverzögerung 0 - 255 45
4 PoM Bremsverzögerung 0 - 255 45
5 PoM Maximalgeschwindigkeit 0 - 255 213
8 Werkreset/Herstellerkennung 8 131
13 PoM Funktionen F1 - F8 im Analogbetrieb 0 - 255 0
14 PoM FunktionenF9-F15undLichtimAnalogbetrieb 0 - 255 1
17 ErweiterteAdresse(obererTeil) CV29,Bit5=1 192
18 ErweiterteAdresse(untererTeil) CV29,Bit5=1 128
19 Traktionsadresse 0 - 255 0
21 PoM FunktionenF1-F8beiTraktion 0 - 255 0
22 PoM FunktionenF9-F15undLichtbeiTraktion 0 - 255 0
29 PoM
Bit0:UmpolungFahrtrichtung
Bit1:AnzahlFahrstufen14oder28/128*
Bit2:DCCBetriebmitBremsstrecke(keinAnalogbetriebmöglich)
Bit5:kurze/langeAdresse
0 / 1
0 / 2
0 / 4
0 / 32
0,1,2,3,4,5,6,7,
32,34,35,36,37,
38,39 6
50 PoM
Alternative Protokolle (DCC kann sich selber nicht deaktivieren)
Bit0:AnalogACaus=0/AnalogACein=1
Bit1:AnalogDCaus=0/AnalogDCein=1
Bit2:fx(MM)aus=0/fx(MM)ein=1
Bit3:mfxaus=0/mfxein=1
0 / 1
0 / 2
0 / 4
0 / 8
0 - 15 15
63 PoM Lautstärke 0 - 255 255
* FahrstufenamLokdecoderundamSteuergerätmüssenübereinstimmen,essindsonstFehlfunktionenmöglich.

9
• ThefullrangeoffunctionsisonlyavailableunderDCC
and mfx.
• Built-inheadlightsthatchangeoverwiththedirectionof
travel.Theycanbeturnedonandoffindigitaloperation.
• Asmokegeneratorcanberetrottedtothelocomotive-
also for analog operation.
• Onlythesmoke,running,andlightchangeoverfunctions
are available in analog operation.
• Minimumradiusforoperationis360mm/14-3/16“.
Multi-Protocol Operation
Analog Operation
Thisdecodercanalsobeoperatedonanaloglayoutsorar-
easoftrackthatareanalog.Thedecoderrecognizesalter-
nating current (DC) and automatically adapts to the analog
track voltage. All functions that were set under mfx or DCC
for analog operation are active (see Digital Operation).
Digital Operation
Thedecodersaremulti-protocoldecoders.Thesedecoders
canbeusedunderthefollowingdigitalprotocols:mfx,DCC
or MM.
Addresssetatthefactory:DCC 03 / MM 45
Thedigitalprotocolwiththemostpossibilitiesisthehighest
orderdigitalprotocol.Thesequenceofdigitalprotocolsin
descendingorderis:
Priority1:mfx
Priority2:DCC
Priority3:MM
Safety Notes
• Thislocomotiveisonlytobeusedwiththeoperating
system it is designed for.
• Analogmax.15voltsDC,digitalmax.22voltsAC.
• Thislocomotivemustneverbesuppliedwithpowerfrom
more than one power pack.
• Pleasemakenoteofthesafetynotesintheinstructions
for your operating system.
• Thefeedertrackmustbeequippedtopreventinter-
ferencewithradioandtelevisionreception,whenthe
locomotiveistoberuninconventionaloperation.The
611 655 interference suppression set is to be used for this
purpose.Theinterferencesuppressionsetisnotsuitable
for digital operation.
• WARNING! Sharp edges and points required for operation.
• Donotexposethemodeltodirectsunlight,extreme
changesintemperature,orhighhumidity.
• TheLEDsinthisitemcorrespondtoLaserClass1accor-
ding to Standard EN 60825-1.
Important Notes
• Theoperatinginstructionsandthepackagingareacom-
ponent part of the product and must therefore be kept as
well as transferred along with the product to others.
• PleaseseeyourauthorizedTrixdealerforrepairsor
spare parts.
• Thewarrantycardincludedwiththisproductspecies
the warranty conditions.
• Disposing:www.maerklin.com/en/imprint.html

10
Note: If two or more digital protocols are recognized in the
track,thedecoderautomaticallytakesonthehighestvalue
digitalprotocol.Forexample,ifmfx&DCCarerecognized,
the mfx digital protocol is taken on by the decoder. Individual
protocols can be deactivated with Parameter CV 50.
Note: Please note that not all functions are possible in all
digitalprotocols.Severalsettingsforfunctions,whichare
supposedtobeactiveinanalogoperation,canbedone
under mfx and DCC.
Notes on digital operation
• Theoperatinginstructionsforyourcentralunitwillgive
you exact procedures for setting the different parame-
ters.
• Thesettingdoneatthefactorydoesnotpermitoperation
with opposite polarity DC power in the braking block.
Ifyouwantthischaracteristic,youmustdowithout
conventionalDCpoweroperation(CV29/Bit2=0).
mfx Protocol
Addresses
• Noaddressisrequired;eachdecoderisgivenaone-
time,uniqueidentier(UID).
• ThedecoderautomaticallyregistersitselfonaCentral
Station or a Mobile Station with its UID.
• Namesetatthefactory:45 022 DB
Programming
• Thecharacteristicscanbeprogrammedusingthe
graphic screen on the Central Station or also partially
with the Mobile Station.
• AlloftheCongurationVariables(CV)canbereadand
programmed repeatedly.
• Theprogrammingcanbedoneeitheronthemaintrackor
the programming track.
• Thedefaultsettings(factorysettings)canbeproduced
repeatedly.
• Functionmapping:Functionscanbeassignedto
any of the function buttons with the help of the
60212 Central Station (with limitations) and with the
60213/60214/60215/60216/60226 Central Station (See help
section in the Central Station).

11
DCC Protocol
Addresses
• Possibleaddresses:short,long,andm.u.address
• Addressrange:
1–127(shortaddress,m.u.address)
1 – 10239 (long address)
• Everyaddresscanbeprogrammedmanually.
• AshortoralongaddressisselectedusingtheCVs.
• Amultipleunitaddressthatisbeinguseddeactivatesthe
standard address.
Programming
• Thecharacteristicscanbechangedrepeatedlyusingthe
CongurationVariables(CV).
• TheCVnumbersandtheCVvaluesareentereddirectly.
• TheCVscanbereadandprogrammedrepeatedly.(Pro-
gramming is done on the programming track.)
• TheCVscanbeprogrammed,asyoudesire.PoM(Pro-
gramming on the layout track) is only possible with those
CVs marked in the CV table. PoM must be supported
by your central controller (see the instructions for your
controller).
• Thedefaultsettings(factorysettings)canbeproduced
repeatedly.
• 14or28/126speedlevelscanbeset.
• Allofthefunctionscanbecontrolledaccordingtothe
function mapping (see CV description).
• SeetheCVdescriptionfortheDCCprotocolforadditional
information.
We recommend that in general programming should be
done on the programming track.
Logic Functions
Acceleration / Braking Delay
• Theaccelerationandbrakingtimescanbesetseparately
from each other.
• ThelogicalfunctionshutoffforABV(Acceleration/
Braking Delay) can be assigned to any function button by
means of function mapping.

12
Controllable Functions
DC/AC
MS I 1
MS II
CS I
CS II/III
Soundeffect:Railjoints F16
Soundeffect:Stationannouncements F17
Soundeffect:Fillingcoal F18
Soundeffect:ReplenishWater F19
Soundeffect:Sanding F20
Soundeffect:Cabconversation F21
Lowspeedswitchingrange F22
Functionsequence:reman F23
Controllable Functions
DC/AC
MS I 1
MS II
CS I
CS II/III
Headlights F0
Smoke generator 2F1
Operating sounds F2
Soundeffect:Longwhistleblast F3
ABV,off F4
Soundeffect:Squealingbrakesoff F5
Engineer‘s cab lighting F6
Soundeffect:Switchingwhistle F7
Glowfromrebox F8
Soundeffect:Blowingoffsteam F9
Soundeffect:Coalbeingshoveled F10
Soundeffect:Rockergrate F11
Soundeffect:Airpump F12
Soundeffect:Injector F13
Soundeffect:Waterpump F14
1 TrixSystems
2Not included in delivery scope.

13
* Thespeedlevelsonthelocomotivedecoderandonthecontrollermustagreewitheachother;otherwise,
you may have malfunctions.
CV Discription DCC Value Factory-Set
1 Address 1 - 127 3
2 PoM Minimum Speed 0 - 255 5
3 PoM Acceleration delay 0 - 255 45
4 PoM Braking delay 0 - 255 45
5 PoM Maximum speed 0 - 255 213
8 Factory Reset / Manufacturer Recognition 8 131
13 PoM Functions F1 - F8 in analog operation 0 - 255 0
14 PoM Functions F9 - F15 and lights in analog operation 0 - 255 1
17 Extended address (upper part) CV29,Bit5=1 192
18 Extended address (lower part) CV29,Bit5=1 128
19 Multiple Unit Address 0 - 255 0
21 PoM Functions F1 - F8 on Multiple Unit 0 - 255 0
22 PoM Functions F9 - F15 and lights on Multiple Unit 0 - 255 0
29 PoM
Bit0:Reversingdirectionoftravel
Bit1:Numberofspeedlevels14or28/128*
Bit2:DCCoperationwithabrakingarea(noanalogoperation
possible)
Bit5:short/longaddress
0 / 1
0 / 2
0 / 4
0 / 32
0,1,2,3,4,5,6,
7,32,34,35,36,
37,38,39 6
50 PoM
Alternative Protocols (DCC cannot deactivate itself)
Bit0:AnalogACoff=0/AnalogACon=1
Bit1:AnalogDCoff=0/AnalogDCon=1
Bit2:fx(MM)off=0/fx(MM)on=1
Bit3:mfxoff=0/mfxon=1
0 / 1
0 / 2
0 / 4
0 / 8
0 - 15 15
63 PoM Volume 0 - 255 255

14
Remarques importantes sur la sécurité
• Lalocomotivenepeutêtreutiliséequ‘aveclesystème
d‘exploitation indiqué.
• Analogiquemax.15Volt=,digitalmax.22Volt~.
• Lalocomotivenepeutpasêtrealimentéeélectriquement
par plus d‘une source de courant à la fois.
• Ilestimpératifdetenircomptedesremarquessurla
sécurité décrites dans le mode d‘emploi de votre système
d‘exploitation.
•
Pour l’exploitation de la locomotive en mode convention-
nel,lavoiederaccordementdoitêtredéparasitée.Acet
effet,utiliserlesetdedéparasitageréf.611655.Lesetde
déparasitage ne convient pas pour l’exploitation en mode
numérique.
•
ATTENTION! Pointes et bords coupants lors du fonctionne-
ment du produit.
• Nepasexposerlemodèleàunensoleillementdirect,
à de fortes variations de température ou à un taux
d‘humidité important.
• LesDELinstalléescorrespondentàlaclasselaser1
selon la norme EN 60825-1.
Information importante
• Lanoticed‘utilisationetl’emballagefontpartieintégrante
duproduit;ilsdoiventdoncêtreconservéset,lecas
échéant,transmisavecleproduit.
• Pourtouteréparationouremplacementdepièces,adres-
sezvousàvotredétaillant-spécialisteTrix.
• Garantielégaleetgarantiecontractuelleconformément
aucerticatdegarantieci-joint.
• Elimination:www.maerklin.com/en/imprint.html
• L’intégralitédesfonctionsestdisponibleuniquementen
exploitation DCC et mfx.
• Feuxdesignalisations‘inversantselonlesensdemar-
che; feux commutables en exploitation digital.
• Installationultérieured’ungénérateurdefuméepossible
- également pour exploitation analogique.
•
Enmoded’exploitationanalogique,seuleslesfonctions
relativesàlafumée,laconduiteetl’inversiondesfeuxsont
disponibles.
• Rayonminimald’inscriptionencourbe360mm.
Mode multiprotocole
Mode analogique
On peut aussi faire fonctionner le décodeur sur des instal-
lationsoudessectionsdevoieanalogiques.Ledécodeur
identieautomatiquementlatensiondevoieanalogique
(DC).Touteslesfonctionsquiontétéparamétréepourle
mode analogique sous mfx ou sous DCC sont actives (voir
mode numérique).
Mode numérique
Lesdécodeursontdesdécodeurmultiprotocole.Le
décodeurpeutêtreutiliséaveclesprotocolesnumériques
suivants:mfx,DCC,MM
Adresseencodéeenusine:DCC 03 / MM 45

15
Leprotocolenumériqueoffrantlespossibilitéslesplus
nombreuses est le protocole numérique à bit de poids
fort.Lahiérarchisationdesprotocolesnumériquesest
descendante:
Priorité1:mfx
Priorité2:DCC
Priorité3:MM
Indication : Si deux ou plus de deux protocoles numériques
sontreconnussurlavoie,ledécodeurchoisitautomatique-
mentleprotocolenumériqueleplussignicatif.Entreles
protocolesmfx&DCCparexemple,ledécodeurchoisira
le protocole numérique mfx. Vous pouvez désactiver les
différents protocoles via le paramètre CV 50.
Indication : remarquez que toutes les fonctions ne peuvent
pasêtreactionnéesdanstouslesprotocolesnumériques.
SousmfxetsousDCC,ilestpossibledeprocéderà
quelquesparamétragesdefonctionsdevantêtreactives
dans le cadre de l’exploitation analogique.
Remarques relatives au fonctionnement en mode digital
• Encequiconcernelaprocédurederéglagedesdivers
paramètres,veuillezvousréféreraumoded‘emploide
votre centrale de commande multitrain.
• L’exploitationaveccourantcontinudepolaritéinverse
dans les sections de freinage n’est pas possible avec
leréglaged’usine.Sicettepropriétéestdésirée,ilfaut
alors renoncer à l’exploitation conventionnelle en cou-
rantcontinu(CV29/Bit2=0).
Protocole mfx
Adressage
• Aucuneadressen’estnécessaire,ledécodeurreçoittou-
tefoisuneidenticationuniqueetnonéquivoque(UID).
• AvecsonUID,ledécodeurindiqueautomatiquement
à une station centrale ou à une station mobile qu’il est
connecté.
• Nomencodeeenusine:45 022 DB
Programmation
• Lescaractéristiquespeuventêtreprogramméespar
l’intermédiaire de la couche graphique de la station cen-
trale,voireenpartieaussiaumoyendelastationmobile.
• Touteslescongurationsvariables(CV)peuventêtrelues
etprogramméesdefaçonréitérée.
• Laprogrammationpeutêtreréaliséesoitsurlavoie
principale,soitsurlavoiedeprogrammation.
• Lesparamétragespardéfaut(paramétragesusine)
peuventêtrerétablis.
• Mappagedesfonctions:lesfonctionspeuventêtre
affectées à de quelconques touches de fonction au
moyen de la station centrale (60212) (restreinte) et avec
la station centrale 60213/60214/60215/60216/60226 (voir
Aide au niveau de la station centrale).

16
Protocole DCC
Adressage
• Adressepossibles:Courtes,longuesetadressesdetraction
• Catégoried’adresse:
1à127(adressescourtes,adressesdetraction)
1 à 10239 (adresses longues)
• Chaqueadresseestprogrammablemanuellement.
• L’adressebrèveoulongueestchoisieparl’intermédiaire
des CVs.
• Uneadressedetractionutiliséedésactivel’adresse
standard.
Programmation
• Lescaractéristiquespeuventêtremodiéesdefaçon
réitéréeparl’intermédiairedesvariablesdeconguration
(CVs).
• Touteslescongurationsvariables(CV)peuventêtrelues
etprogramméesdefaçonréitérée.
• Laprogrammationpeutêtreréaliséesoitsurlavoie
principale,soitsurlavoiedeprogrammation.
• LesCVpeuventêtreprogramméeslibrement.LaPoM
(programmation sur la voie principale) est possible
uniquement pour les CV signalées dans le tableau des CV.
LaPoMdoitêtrepriseenchargeparvotrecentrale(voir
la notice d’utilisation de votre appareil).
• Lesparamétragespardéfaut(paramétragesusine)
peuventêtrerétablis.
• 14voire28/126cransdemarchesontparamétrables.
• Touteslesfonctionspeuventêtrecommutéesenfonction
du mappage des fonctions (voir le descriptif des CVs).
• Pourtouteinformationcomplémentaire,voirletableau
desCVs,protocoleDCC.
Ilestrecommandé,deréaliserlaprogrammation,fonda-
mentalement,surlavoiedeprogrammation.
Fonctions logiques
Temporisation d’accélération et de freinage (TAF)
• Lestempsd’accélérationetdefreinagepeuventêtre
dénisindépendammentl’undel’autre.
• LadésactivationdelafonctionlogiqueTAFpeutêtre
affectée à n’importe quelle touche de fonction via le
mappage de fonctions.

17
Fonctions commutables
DC/AC
MS I 1
MS II
CS I
CS II/III
Bruitage:jointsderail F16
Bruitage:Annonceengare F17
Bruitage:Approvisionnementen
charbon F18
Bruitage:Eau,remiseàniveau F19
Bruitage:Sablage F20
Bruitage:Conversationdansleposte
de conduite F21
Vitesse de manœuvre
F22
Suitefonctions:Chauffeur F23
Fonctions commutables
DC/AC
MS I 1
MS II
CS I
CS II/III
Fanal F0
Générateur de fumée 2F1
Bruit d’exploitation F2
Bruitage:sifetlongueur F3
ABV,désactivé F4
Bruitage:Grincementdefreins
désactivé F5
Eclairage de la cabine de conduite F6
Bruitage:Sifetpourmanœuvre F7
Lueursdanslefoyer F8
Bruitage:Échappementdelavapeur F9
Bruitage:Pelletageducharbon F10
Bruitage:Grilleàsecousses F11
Bruitage:Compresseur F12
Bruitage:Injecteur F13
Bruitage:Pompeàeau F14
1 TrixSystems
2Ne fait pas partie de la fourniture.

18
CV Affectation DCC Valeur Parm. Usine
1 Adresse 1 - 127 3
2 PoM Vitesse minimale 0 - 255 5
3 PoM Temporisationd‘accélération 0 - 255 45
4 PoM Temporisationdefreinage 0 - 255 45
5 PoM Vitesse maximale 0 - 255 213
8Réinitialisationd’usine/identicationdufabricant 8 131
13 PoM Fonctions F1 - F8 en mode analogique 0 - 255 0
14 PoM Fonctions F9 - F15 et éclairage en mode analogique 0 - 255 1
17 Adresse étendue (partie supérieure) CV29,Bit5=1 192
18 Adresse étendue (partie inférieure) CV29,Bit5=1 128
19 Adresse traction 0 - 255 0
21 PoM Fonctions F1 - F8 pour traction 0 - 255 0
22 PoM Fonctions F9 - F15 et éclairage traction 0 - 255 0
29 PoM
Bit0:Inversiondusensdemarche
Bit1:Nombredecransdemarche14ou28/128*
Bit2:ExploitationDCCavecsectiondefreinage(exploitation
analogique impossible)
Bit5:Adressecourte/longue
0 / 1
0 / 2
0 / 4
0 / 32
0,1,2,3,4,5,6,
7,32,34,35,36,
37,38,39 6
50 PoM
Autresprotocoles(DCCnepeutpassedésactiverlui-même)
Bit0:AnalogiqueCAhorsfonction=0/analogiqueCAenfonction=1
Bit1:AnalogiqueCChorsfonction=0/analogiqueCCenfonction=1
Bit2:fx(MM)horsfonction=0/fx(MM)enfonction=1
Bit3:mfxhorsfonction=0/mfxenfonction=1
0 / 1
0 / 2
0 / 4
0 / 8
0 - 15 15
63 PoM Volume 0 - 255 255
* Pourévitertoutdysfonctionnement,lescransdemarchesurledécodeurdelocodoiventimpérativement
coïncider avec ceux de l’appareil de commande.

19
Veiligheidsvoorschriften
• Delocmagalleenmeteendaarvoorbestemdbedrijfssys-
teem gebruikt worden.
• Analoogmax.15Volt=,digitaalmax.22Volt~.
• Delocmagnietvanuitmeerdanéénstroomvoorziening
gelijktijdig gevoed worden.
• Leesookaandachtigdeveiligheidsvoorschrifteninde
gebruiksaanwijzing van uw bedrijfssysteem.
• Voorhetconventionelebedrijfmetdelocdientde
aansluitrail te worden ontstoort. Hiervoor dient men de
ontstoor-set 611 655 te gebruiken. Voor het digitale bedrijf
is deze ontstoor-set niet geschikt.
• OPGEPAST! Functionele scherpe kanten en punten.
• Stelhetmodelnietblootaanindirectezonnestraling,
sterke temperatuurwisselingen of hoge luchtvochtigheid.
• IngebouwdeLED’skomenovereenmetdelaserklasse1
volgens de norm EN 60825-1.
Belangrijke aanwijzing
• Degebruiksaanwijzingendeverpakkingzijneenbe-
standdeel van het product en dienen derhalve bewaard
en meegeleverd te worden bij het doorgeven van het
product.
• VoorreparatiesenonderdelenkuntzichtotUwTrix
handelaar wenden.
• Vrijwaringengarantieovereenkomstighetbijgevoegde
garantiebewijs.
• Afdanken:www.maerklin.com/en/imprint.html
• Devolledigetoegangtotallefunctiesisalleenmogelijk
met DCC of met mfx bedrijf.
• Ingebouwde,rijrichtingsafhankelijkefrontverlichtingisin
het digitaalsysteem schakelbaar.
• Rookgeneratornadienintebouwen-ookvooranaloog
bedrijf.
• Inanaloogbedrijfzijnalleenroken-,rijden,enlichtwisse-
ling als functie beschikbaar.
• Minimaleteberijdenradius:360mm.
Multiprotocolbedrijf
Analoogbedrijf
De decoder kan ook op analoge modelbanen of spoortra-
jecten gebruikt worden. De decoder herkent de analoge
gelijkspanning (DC) automatisch en past zich aan de
analoge railspanning aan. Alle functies die onder mfx of DCC
voorhetanalogebedrijfzijningesteld,wordengeactiveerd
(zie digitaalbedrijf).
Digitaalbedrijf
De Decoder is een multiprotocoldecoder. De decoder kan
onderdevolgendedigitaleprotocolleningezetworden:mfx,
DCC,MM.
Vanafdefabriekingesteld:DCC 03 / MM 45
Het digitaalprotocol met de meeste mogelijkheden is het
primaire digitaalprotocol. De volgorde van de digitaalproto-
collenisafnemendinmogelijkheden:
Prioriteit1:mfx
Prioriteit2:DCC
Prioriteit3:MM

20
Opmerking: Als er twee of meer digitale protocollen op
derailswordenherkend,danneemtdedecoderautoma-
tisch het hoogwaardigste protocol over; bijv. word mfx &
DCCherkend,danwordthetmfxsignaaldoordedecoder
overgenomen. De verschillende protocollen kunnen via de
parameter CV 50 gedeactiveerd worden.
Opmerking: let er op dat niet alle functies in alle digitaal-
protocollen mogelijk zijn. Onder mfx of DCC kunnen enkele
instellingen,welkeinanaloogbedrijfwerkzaammoetenzijn,
ingesteld worden.
Aanwijzingen voor digitale besturing
• Hetopdejuistewijzeinstellenvandediverseparame-
ters staat beschreven in de handleiding van uw digitale
Centrale.
• Hetbedrijfmettegengepooldegelijkspanningindeafrem-
sectie is met de fabrieksinstelling niet mogelijk. Indien deze
eigenschapwenselijkis,danmoetwordenafgezienvan
hetconventioneelgelijkstroombedrijf(CV29/Bit2=0).
mfx-protocol
Adressering
• Eenadresisnietnodig,elkedecoderheefteenéénmalig
en éénduidig kenmerk (UID).
• DedecodermeldtzichvanzelfaanbijhetCentralStation
of Mobile Station met zijn UID.
• Naamafdefabriek:45 022 DB
Programmering
• Deeigenschappenkunnenm.b.v.hetgraschescherm
op het Central Station resp. deels ook met het Mobile
Station geprogrammeerd worden.
• Alleconguratievariabelen(CV)kunnenvakergelezen
en geprogrammeerd worden.
• Deprogrammeringkanzowelophethoofdspooralsop
het programmeerspoor gebeuren.
• Dedefault-instellingen(fabrieksinstelling)kunnenweer
hersteld worden.
• Functiemapping:functieskunnenmetbehulpvanhet
Central Station 60212 (met beperking) en met het
Central Station 60213/60214/60215/60216/60226 aan elke
gewenste functietoets worden toegewezen (zie het
helpbestand in het Central Station).
This manual suits for next models
1
Table of contents
Languages:
Other Trix Toy manuals

Trix
Trix BR 798 User manual

Trix
Trix 1018.0, OBB User manual

Trix
Trix BR 218 User manual

Trix
Trix BR 984-5 User manual

Trix
Trix minitrix V80, BR 280 User manual

Trix
Trix Minitrix 16904 User manual

Trix
Trix ET 56 User manual

Trix
Trix h0 PtL 2/2 User manual

Trix
Trix BR 41 User manual

Trix
Trix Mak G1000BB User manual

Trix
Trix BR 23 User manual

Trix
Trix VT98 DB User manual

Trix
Trix h0 EP 3/6 User manual

Trix
Trix Ce 6/8 II Series User manual

Trix
Trix BR 141 / E 41 User manual

Trix
Trix BR 74 User manual

Trix
Trix BR 212 User manual

Trix
Trix ER 20 EVB User manual

Trix
Trix BR 141 / E 41 User manual

Trix
Trix 103 101-2 User manual