WMF 950 S planning information
Conditions for usage and installation
Any necessary on-site preparatory work for electricity, water and drainage connections at the customer‘s premises
is to be arranged by the machine owner / operator. The work must be carried out
by authorised installation technicians in compliance with general, country-specific and local regulations.
Dimensions and
empty weight
Width
Height
Depth
Clearance height
Weight
303 mm
562 mm
528 mm
75 –155 mm
Approx. 22 kg
Water supply Water supply line
Inlet temperature
Water drain tube
(optional)
3/8 inch hose connector with mains tap, and filter with 0.08 mm mesh
size, on site. At least 0.2 MPa (2 bar) flow pressure at 2 l/min
(standard). Maximum 0.6 MPa (6 bar). If the on-site flow pressure
exceeds 0.6MPa (6 bar) a pressure reducer must be connected upstream
which must be set to a maximum of 0.6 Mpa. For fixed water operation
the connection items included in the accessories must be used. Do not
use old hose sets.
Maximum 35 °C.
Tube a minimum of DN 19, minimum downward slope
of 2 cm/m
For use at
altitude above
NN
< 2000 m
Electrical data Nominal power rating 2.6 –2.8 kW
Power supply 220–240 V 50 / 60 Hz (1 / N / PE), country specific power supply
available
Degree of protection IP X0
Protection Class I
Installation
Clearance
For operating, service, and safety reasons the machine should be installed with a clearance from
the building or non-WMF components of not less than 50 mm at the sides and 60 mm at the
back. A minimum working space of 800 mm in front of the coffee machine is recommended.
Clearance of at least 200 mm above the product hopper is recommended. The height of the
installation surface above the floor is at least 850 mm. If the coffee machine connections are to
be run downwards through the counter, please make space for the lines, which can reduce the
usable space below the machine.
If the coffee machine is operated with a water filter the additional space under the machine
depending on the filter size has to be considered. For further information see filter instructions.
Caution: Auxiliary units can only be installed on the right side of the machine (seen from the
operating side)
Ventilation If ventilation possibility is limited sufficient ventilation need to be provided e.g machine on feet
extension, active ventilation, additional ventilation slots/ openings in counter area. Ventilation
slots must not be covered. Under certain circumstances a forced ventilation on site is necessary to
ensure heat dissipation.
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF GmbH | WMF Platz 1 |73312 Geislingen (Steige)