Yale nexTouch Technical specifications

Retrofitting or modifying this product may impact fire rating, safety features and warranty.
Consult with code specifications to ensure compliance with all codes and ratings.
nexTouch™ Keypad Access Exit Trim Lock
Touchscreen and Push Button
Installation and Programming Instructions
WARNING
This product can expose
you to lead which is
known to the state of
California to cause cancer
and birth defects or other
reproductiveharm.For
more information go to
www.P65warnings.ca.gov.
08/2018
80-8470-0900-000 04-21
Part of ASSA ABLOY

Before You Begin
280-8470-0900-000 04-21
Part of ASSA ABLOY
AA
AA
AA
AA
Optional
Network Module
template
#3 & #2
1/2"3/4"
Left Hand
Reverse Right Hand
Reverse
Face a door swinging open
toward you.
If it swings open to the right, it is
a right hand reverse door. If it
swings opens to the left, it is a left
hand reverse door.
Exterior
Outswinging Door
Interior
Optional
Privacy DPS Switch
Fire
Guard
Tools Needed

3
1
80-8470-0900-000 04-21
Part of ASSA ABLOY
Prepare Door
Drill holes 1/2 way thru
door then complete
from other side to
prevent splitting.
DPS Option
for Privacy Function
Wood Door:
3/8" Dia. Thru to
Hole in Door Face
*Metal Door:
3/4" Dia. Thru to
Hole in Door Face
*Metal Door Installations
Supplied plastic collar
MUST be installed for DPS
to function properly.
template
Door Position Switch Option
O
optional
Privacy DPS Switch
With Door Position Switch installed and
door closed, all keypad functions can be
disabled by Privacy Button.

2
80-8470-0900-000 04-21
Part of ASSA ABLOY
Test Cylinder
Test cylinder by turning key counter-clockwise to unlock trim.
If there is any binding then cylinder is not at correct depth
and needs to be threaded further into escutcheon.
If using cylinder other than 1-1/8", a new collar must
be used that is sized appropriately for cylinder length.
Install Cylinder
Tighten
counter-clockwise
to secure lock.
Use key to thread
cylinder. Pull key
out of cylinder to
first blade cut for
best operation.
X
4

3
There is a
spring inside
spindle. Be
sure to keep
spring for
reassembly.
Set screw should be
located on same
side as lever arm.
1
2
2
1
1
2
1
2
Change Hand of Trim (if necessary)
Right Hand ReverseLeft Hand Reverse
Tighten nut then
loosen just enough
that spindle tab
aligns with top of
hole.
Be sure spring
is inside spindle.
Spindle
Tab
Nut
580-8470-0900-000 04-21
Part of ASSA ABLOY

6
4Install Outside Trim Assembly
#10-32 x 1" OHPMS
x2
80-8470-0900-000 04-21
Part of ASSA ABLOY
Do not take
apart outside
assembly.
Do not tighten
screws until
exit device
installation -Step 5.
2 hinge side screws
hold outside trim
assembly until exit
device is installed.
All 4 screws MUST
be used for proper
installation.
1
2
Exit Device
Mounting
Holes

7
5
80-8470-0900-000 04-21
Part of ASSA ABLOY
Test Mechanical Lock Function by
Key, Lever and Keypad
Install Exit Device
x2
#10-32 x 1" PHMS
Tighten all screws.
3
4
Refer to exit device installation instructions
for details of device installation.

8
6
80-8470-0900-000 04-21
Part of ASSA ABLOY
Install Strike and Optional DPS
x3
#10-24 PFHMS
Refer to exit device installation instructions
for details of strike installation.
3-1/2"
DPS Option
for Privacy Function
*Metal Frame:
3/4" Dia. x 1"
See Instructions with DPS Kit
*Supplied plastic collar MUST
be installed for DPS to
function properly.
Frame
Strike must be centered with exit device bolt. For
proper engagement, door should remain latched
and not rattle when pushed, pulled or shaken in/out.

2
Inside of Door
Optional
DPS
1
9
7
80-8470-0900-000 04-21
Part of ASSA ABLOY
x1
#10-32 x 1-1/2"
THPMS
Install Inside Mounting Plate
x2
#8 x 3/8" PRH
Sheet Metal
OR
#8 x 1/2" PHWS
Wood
x2

10
8
80-8470-0900-000 04-21
Part of ASSA ABLOY
Attach Cables to Inside Lock
Optional
DPS
Connection
Motor
Connection
Keypad
Connection
Reset
Button
External
Power

11 80-8470-0900-000 04-21
Part of ASSA ABLOY
9Install Inside Lock
x3
#8-32 x 5/16" PHMS
Avoid crimping
cables!
Do not tighten
screws until lock is
flat against plate
without excessive
pressure.

12
10
11 Install Batteries & Cover
Install Module (optional)
"Welcome to
Yale"
Network or Yale Accentra Key Module
Optional Network or Yale
Accentra Key module must
be installed BEFORE
batteries.
80-8470-0900-000 04-21
Part of ASSA ABLOY
The Yale Accentra Key module
enables access with physical
(cards and fobs) and mobile
credentials ONLY. Creation and use
of User PIN codes are disabled.

13
12
80-8470-0900-000 04-21
Part of ASSA ABLOY
Congratulations, you've installed the Yale nexTouch™ Exit Trim Lock!
Continue to customize your product.
Install Exit Device Cover
Test Electronic Lock Function by Keypad
See Programming
Instructions to create
Master PIN code
before testing. Enter
PIN code and press
to test.

Programming Instructions
Speaker
Inside Lock
Privacy
Button
Indicator
Light
14
Low Battery Indicator
(Touchscreen)
Keypad
9 Volt Battery
Override Terminal
Lockout Mode Indicator
(Touchscreen)
Unlock Indicator
(Touchscreen)
Lock Activation
On Touchscreen
models touch Yale
logo to wake lock
Lock Activation
On Push Button
models touch check
mark to wake lock
80-8470-0900-000 04-21
Part of ASSA ABLOY

1Creating Master PIN Code
Creating a Master PIN Code must be performed upon installation or after resetting the lock to factory
default. Programming and use of lock is not possible until this step has been successfully completed.
15 80-8470-0900-000 04-21
Part of ASSA ABLOY
Enter 4-8 digit
Master PIN Code.
Press
Press
"Registered."
"Completed."
"Register Master
Code. Press the gear
key to continue."
Press
(Touchscreen)
Press
(Push Button)
"Enter a 4-8 digit
PIN code. Press the
gear key to continue."

Creating User PIN Codes
2aMaster PIN code must be created first.
*Max User Codes = 500
16
The Yale Accentra Key module enables access with physical (cards and fobs) and
mobile credentials ONLY. Creation and use of User PIN codes are disabled.
80-8470-0900-000 04-21
Part of ASSA ABLOY
Enter Master
PIN code
Press
Press
Press
"Press 1 to
register a code."
"Register User code.
Press the gear key to
continue." Press
Press
"PIN code registration.
Enter a 4-8 digit PIN code.
Press the gear key
to continue."
"Menu Mode,
enter number."
Press
(Touchscreen)
Press
(Push Button)
"Register User code.
Press the gear key to
continue."

2bCreating User PIN Codes con't
17 80-8470-0900-000 04-21
Part of ASSA ABLOY
Press
Adding more User Codes:
Enter 4-8 digit PIN code
Press
To end programming:
Press
"Registered.
Press the check key to
complete. Press the gear
key to continue."
Enter 4-8 digit PIN code
followed by
"Completed."
"Registered.
Press the check key to
complete. Press the gear
key to continue."

3Locking & Unlocking Door with
Registered Master or User PIN Code
4
18
The Yale Accentra Key module enables access with physical (cards and fobs) and
mobile credentials ONLY. Creation and use of User PIN codes are disabled. Master
PIN code is only used for programming and configuring lock with Yale Accentra
Multi-Family configuration app and will not unlock door.
80-8470-0900-000 04-21
Part of ASSA ABLOY
Enter PIN Code
Press
Press
(Touchscreen)
Press
(Push Button)
DPS
installation is
required for
this feature.
Privacy must
be 'Enabled'
from feature
menu.
Locking Door with Privacy Button

Resetting Lock to Factory Default
19 80-8470-0900-000 04-21
Part of ASSA ABLOY
1. Remove battery cover with supplied hex wrench.
2. Remove three (3) screws from inside lock to release lock from bracket plate.
3. Remove network module if installed.
4. Reset button is on back of inside lock. Cables may stay connected. (See illustration for location of
reset button.)
5. Press reset button for 3 seconds.
6. While continuing to press reset button, temporarily remove one (1) AA battery.
7. Reinstall battery.
8. Release reset button and wait approximately 15 seconds. Speaker will announce "Welcome to Yale.”
9. Reinstall inside lock.
10. If utilizing a network module, remove batteries. Insert network module. Reinstall batteries.
Inside Lock
When lock is reset to factory defaults all user
codes (including the Master PIN code*) are
deleted and all programming features are reset to
original default settings (see Factory Settings).
Master PIN Code creation is the only option
available and must be performed prior to any other
programming of the lock.
Button
Reset
Screw Location
Screw
Location

Definitions
20 80-8470-0900-000 04-21
Part of ASSA ABLOY
All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except
Master) PIN code access.
When attempting to enter a code while unit is in Lockout, there will be an audible
lock response. The touchscreen keypad will display a RED locked padlock. (Main Menu selection #6.)
Automatic Re-lock Time: After a successful unlock, unit will re-lock automatically after 5 seconds or for a
duration selected in Advanced Lock Settings. (Main Menu selection #3 then #1)
Eco Mode: When enabled, Eco Mode puts unit in low power mode extending life of battery.
Inside Indicator Light: This light will blink red when the trim is locked.
Language Setting Mode: Choose English (1), Spanish (2) or French (3) for lock's voice prompts. (Main Menu
selection #5)
Low Battery: When battery power is low, the Low Battery Warning indicator is a flashing red battery icon on the
touchscreen keypad and the Yale logo will flash red on the push button keypad. If battery power is completely
lost, use 9Volt battery override. To use 9V battery override apply 9V battery, in either direction, to terminals on
the touchscreen for backup power option. Activate the touchscreen and enter your pin code to unlock door.
Master PIN Code: The Master PIN code is used for programming and for feature settings. It must be created
prior to programming lock.
The Master PIN code will also unlock/lock the lock except when Accentra Key
Module is installed.
Network Module Setting: With optional Network Module installed, this setting becomes available (Main Menu
selection #7) and allows the lock to connect with a network controller.
One Touch Locking:
When unit is unlocked, activating the lock will lock unit (during Automatic Re-lock
duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is not in use (disabled), any valid
PIN code will re-lock the lock. (Main Menu selection #3 then #3.)
Passage PIN Code: When used to unlock, lock will remain unlocked/open. Lock cannot be locked/secured
until Passage code is entered again.
Privacy Button to Lock Door:
If Automatic Re-lock is disabled, a short 1 second press of this button will lock
the door.
Privacy Mode: With optional Door Position Switch installed, Privacy Mode enabled thru Menu Mode and door
closed, all keypad functions can be disabled with a 3 second press of the Privacy Button. Privacy Mode is
disabled by default. Enable Privacy Mode thru Main Menu selection #3 then #4. With door closed, press and
hold the privacy button until voice prompt indicates Privacy Mode is enabled. Privacy Mode duration ends
when door is opened and voice prompt indicates Privacy Mode is disabled.
Shut Down Time: Unit will shut down for sixty (60) seconds and not allow operation after wrong code entry
limit (5 attempts) has been met. When unit is in Shut down, keypad will be flashing.
Tamper Alert: Audible alarm sounds if attempting to forcibly remove outside lock from door.
User PIN Code: The User code operates the lock. Maximum number of user codes is 500.
Volume Setting Mode: The volume setting for PIN code verification is set to HIGH (1) by default; otherwise it
can be set to Low (2) or Silent (3) for quiet areas. (Main Menu selection #4)
Wrong Code Entry Limit: After five (5) unsuccessful attempts at entering a valid PIN code, lock will not accept
a PIN code for duration of shut down time. The touchscreen keypad will flash and a red lock symbol will be at
bottom of keypad. The push button keypad will flash and Yale icon will flash blue for shut down period. Keypad
will be available after shut down time is complete.
Other manuals for nexTouch
4
Table of contents
Other Yale Door Lock manuals

Yale
Yale Doorman User manual

Yale
Yale Keyfree Connected User manual

Yale
Yale YDR3110 User manual

Yale
Yale YDG413A User manual

Yale
Yale Doorman User manual

Yale
Yale GATEMAN YDM 3109 User manual

Yale
Yale Doorman User manual

Yale
Yale Assure Lock Lever Touchscreen YRL226 User manual

Yale
Yale 630F User manual

Yale
Yale YDM 3111 User manual

Yale
Yale D100 Series User manual

Yale
Yale YDR 3111 User manual

Yale
Yale Real Living YRD156 Technical specifications

Yale
Yale Conexis L1 User manual

Yale
Yale MORTISE 8800 SERIES User manual

Yale
Yale 5400 Series User manual

Yale
Yale Real Living Technical specifications

Yale
Yale 7110 User manual

Yale
Yale YDM4109 User manual

Yale
Yale SCP400 Series User manual