PCP - 04 TIME RELAY
INSTRUCTION MANUAL
Zakład Mechaniki i Elektroniki
ZAMEL sp.j.
J.W. Dzida, K. Łodzińska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: [email protected]
APPERANCE
FEATURES
DESCRIPTION
ی 8 operating modes,
ی Relay state and time counting indica-
tor – LED,
ی Triggered by means of power supply
voltage or control input in dependence
of set operating mode,
ی High accuracy of time measure,
ی Relay output – one changeover
contact, 5 A maximum load,
ی Casing designed for mounting in
a junction box.
The PCP-04 multifunction relay is de-
signed for timing function implementation
in automatics and control systems. Both
power supply voltage and control input
trigger the relay. The PCP-04 relay is
capable of operating in 8 independent op
modes which may be triggered by means
of either power supply voltage or external
trigger impulse (from either L or N wires).
It is possible to adjust time within very
wide range. The device is tted with the
relay state indicator – the LED. It is pos-
sible to mount the device in the 60 mm
junction box.
TECHNICAL DATA
PCP- 04
Power terminals: L (black), N (blue)
Rated voltage: 230 V ~
Rated voltage tolerance: -15 ÷ +10 %
Rated frequency: 50 / 60 Hz
Rated current: 15,5 mA
External trigger terminal: IN (triggered from L or N line)
Trigger current: 510 μA
Op modes quantity: 8
t time adjustment range: 0,1 s ÷ 10 days (servo + continuous)
Time measure accuracy: 0,2 %
Relay state and time measure indicator: red LED
Relay contacts parameters:
1NO5 A / 250 V AC1 1250 VA (voltage
contact)
Connection terminals / leads quantity: 4
Connection wire section: 1 mm2
Operating temperature: -20 ÷ +60 oC
Operating position: optional
Casing fastening: 60 mm junction box
Casing IP: IP20 (PN-EN 60529)
Protection class: II
Overvoltage category: II
Pollution level: 2
Dimensions: 50 x 50 x 15 mm
Weight: 30 g
Standard conformity: PN-EN 60730-1
PN-EN 60730-2-7
PN-EN 61000-4-2,3,4,5,6,11
Load / time measure indicator
Load power supply lead (P)
Power lead (L)
Operating mode selection
Trigger lead (IN)
ON-time setting
Time range selection
Power lead (N)
b
r
o
w
n
r
e
d
b
l
a
c
k
b
l
u
e
The timer should be
connected to a single-
phase system accordin-
gly to current standards.
The device connections
will be described in this
manual. Only qualied electricians are
allowed to assembly, connect and ad-
just the timer. It is necessary to read this
manual before the timer mounting. Do
not disassembly the timer casing or you
will lose any warranty rights and expo-
se yourself to the electric shock hazard.
Before mounting operation make sure
of disconnecting the connection wires
from the electric network. The timer
should be carried, stored and used in
an appropriate way. Do not mount the
timer in case of any device parts lack,
damage or deformation. In case of mal-
function please notify the manufacturer.
CAUTION
ASSEMBLY
CONNECTIONS
CASING DIMENSIONS
PRODUCT FAMILY
The PCP-04 time relay is a member
of the PCX product family.
1. Disconnect the electric network by
means of an appropriate cut-off,
current-limiting circuit-breaker or
separator.
2. Check if there is no any voltage
between power leads by means of
an appropriate gauge.
3. Mount the PCP-04 device in the 60
mm junction box.
4. Connect wires according the electri-
cal diagram.
5. Connect power supply circuit.
6. Select the op mode by means of the
MODE switch.
7. Select time by means of the TIME
handwheel and the RANGE switch,
where t= TIME x RANGE.
OPERATION
LOAD
Power supply voltage trigger:
U
A
tt
DELAYED SWITCH-ON – t time will be measured after power supply
voltage has been switched ON. When the t time is over, the relay will
be ON. The op mode will be triggered again after power supply voltage
switching OFF and ON again.
U
t t
B
DELAYED SWITCH-OFF – the relay will be ON just after power supply
voltage switching ON and the t time will be measured. When the t time
is over the relay will be OFF. The operating mode will be triggered again
after power supply voltage switching OFF and ON again.
U
tt t ttt
C
CYCLIC SWITCHING (starts from the OFF state) – t time will be measured
after power supply voltage has been switched ON. When the t time is over, the
relay is ON. Then the relay will be switched alternatively in t time cycles. The
operating mode will be OFF when power supply is OFF.
External impulse trigger:
S
D
t t
TIME IMPULSE TRIGGERED WITH RISING EDGE – when supplied, the
module will switch ON the relay when trigger impulse rising edge comes.
Then the preset time will be measured. When t time is over, the relay will
be OFF. Trigger impulse duration is irrelevant.
S
t t
E
TIME IMPULSE TRIGGERED WITH TRAILING EDGE – when supplied,
the module will switch ON the relay when trigger impulse trailing edge
comes. Then the preset time will be measured. When t time is over, the
relay will be OFF. Successive trigger impulse decays during t time dura-
tion will not cause time counting reset (non-retriggerable circuit).
S
tt
F
ttt
DELAYED SWITCHING ON / OFF – when supplied, the module will not
switch ON the relay and will start t time measure when trigger impulse
rising edge comes. When t time is over, the relay will be ON t time will be
counted once again when trigger impulse trailing edge comes. When t
time is over, the relay will be OFF. If the impulse duration is shorter than
t time, the relay will be ON for t time only.
S
tt
G
t
BISTABLE RELAY WITH TIME LIMIT – when supplied, the module will
switch ON the relay and start t time measure when trigger impulse rising
edge comes. The relay will be switched OFF when the next trigger impul-
se rising edge comes or after t time has been over if the trigger impulse do
not come. The impulse duration is irrelevant for the circuit operation.
S
H
t tt t
t
TIME IMPULSE TRIGGERED WITH RISING EDGE WITH DELAYED
SWITCH OFF (retrigerrable) – when supplied, the module will switch ON
the relay when trigger impulse rising edge comes. When trigger impulse
trailing edge comes, t time will be measured and when the time is over, the
relay will be OFF. Successive trigger impulse trailing edge will cause t time
counting reset and measure from the beginning (retrigerrable).
Multiplier:
0,1 s 1 s 10 s 1min.
10 min. 1 hour 10 hours 1day
MODE
MODE
MODE
MODE
MODE
MODE
MODE
MODE
RANGE
RANGE
RANGE
RANGE
RANGE
RANGE
RANGE
RANGE
375 W 180 W
90 W 150 W
L/N
b
r
o
w
n
r
e
d
b
l
a
c
k
b
l
u
e
24 VAC/DC power supply
Device version:
01 - mode: delayed ON
02 - mode: delayed OFF
03 - mode: cyclic changeover
04 - few op modes
10 - 10 modes,two periods
adjustment
Casing type:
M - single-module
(double-module for 10 ver.)
P - for junction box
Device type
WARRANTY
The product warranty is for a period of 24 months
Dealer signature & stamp, purchase date
1. ZMIE ZAMEL SP. J. assures 24 months guarantee for the product.
2. The manufacturer’s guarantee does not cover any of the following actions:
a) mechanical damage during transport, loading / unloading or under other circumstances,
b) damage caused by incorrect product mounting or misuse,
c) damage caused by unauthorised modications made by the PURCHASER or any third parties to the product or any other devices
needed for the product functioning,
d) damage caused by Act of God or any other incidents independent of the manufacturer.
3. The PURCHASER shall lay any claims in writing to the dealer or ZMIE ZAMEL SP. J.
4. ZMIE ZAMEL SP. J. is liable for processing any claim according to current Polish legislation.
5. ZMIE ZAMEL SP. J. shall process the claim at its own discretion: product repair, replacement or money return.
6. The manufacturer’s guarantee is valid in the Republic of Poland.
7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or
otherwise are not affected by this warranty.

Other Zamel Relay manuals

Zamel Exta PBM-03 User manual

Zamel

Zamel Exta PBM-03 User manual

Zamel EXTA PBP-01 User manual

Zamel

Zamel EXTA PBP-01 User manual

Zamel Exta PCM-02/U User manual

Zamel

Zamel Exta PCM-02/U User manual

Zamel PCM-02/24V User manual

Zamel

Zamel PCM-02/24V User manual

Zamel Exta PBM-07 User manual

Zamel

Zamel Exta PBM-07 User manual

Zamel exta PB Series User manual

Zamel

Zamel exta PB Series User manual

Zamel PCM-08 User manual

Zamel

Zamel PCM-08 User manual

Zamel EXT10000084 User manual

Zamel

Zamel EXT10000084 User manual

Zamel EXTA PBM-03 User manual

Zamel

Zamel EXTA PBM-03 User manual

Zamel exta PCM-09 User manual

Zamel

Zamel exta PCM-09 User manual

Zamel PNM-32 User manual

Zamel

Zamel PNM-32 User manual

Zamel exta PPM - 05 User manual

Zamel

Zamel exta PPM - 05 User manual

Zamel EXTA PCM-11 User manual

Zamel

Zamel EXTA PCM-11 User manual

Zamel Exta PBM-04/U User manual

Zamel

Zamel Exta PBM-04/U User manual

Zamel PCM-04/24V User manual

Zamel

Zamel PCM-04/24V User manual

Zamel exta PCM-01 User manual

Zamel

Zamel exta PCM-01 User manual

Zamel EXTA PBM-02 User manual

Zamel

Zamel EXTA PBM-02 User manual

Zamel exta PBM-07 User manual

Zamel

Zamel exta PBM-07 User manual

Zamel exta PNM-10 User manual

Zamel

Zamel exta PNM-10 User manual

Zamel PBM-01 User manual

Zamel

Zamel PBM-01 User manual

Zamel PCM-07/U User manual

Zamel

Zamel PCM-07/U User manual

Zamel EXTA PCP-06 User manual

Zamel

Zamel EXTA PCP-06 User manual

Zamel PNM-10 User manual

Zamel

Zamel PNM-10 User manual

Popular Relay manuals by other brands

Siemens SIPROTEC 7SJ81 manual

Siemens

Siemens SIPROTEC 7SJ81 manual

Bender IOM441-S manual

Bender

Bender IOM441-S manual

LOVATO ELECTRIC LVM25 manual

LOVATO ELECTRIC

LOVATO ELECTRIC LVM25 manual

LOVATO ELECTRIC TMM1 NFC user manual

LOVATO ELECTRIC

LOVATO ELECTRIC TMM1 NFC user manual

Basler H12345678 R U instruction manual

Basler

Basler H12345678 R U instruction manual

GE P642 Technical manual

GE

GE P642 Technical manual

Hobby Components SmartRFy HCMODU0145 manual

Hobby Components

Hobby Components SmartRFy HCMODU0145 manual

Ampcontrol MAG-153 user manual

Ampcontrol

Ampcontrol MAG-153 user manual

Kobold NE-5048 operating instructions

Kobold

Kobold NE-5048 operating instructions

Revo S3PH user manual

Revo

Revo S3PH user manual

ABB TD-5 Instruction leaflet

ABB

ABB TD-5 Instruction leaflet

MerCs ME-ELR-DD user manual

MerCs

MerCs ME-ELR-DD user manual

Siemens SIRIUS 3TK2827 operating instructions

Siemens

Siemens SIRIUS 3TK2827 operating instructions

Velleman VM129 user guide

Velleman

Velleman VM129 user guide

Pickering 40-110 user manual

Pickering

Pickering 40-110 user manual

Contrel ELR-4 instruction manual

Contrel

Contrel ELR-4 instruction manual

ASO SK 32-31 operating manual

ASO

ASO SK 32-31 operating manual

Schweitzer Engineering Laboratories SEL-787 instruction manual

Schweitzer Engineering Laboratories

Schweitzer Engineering Laboratories SEL-787 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.