ADTEK CS1-RL User manual

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
1 / 30
CS1-RL
LINEARLYLINESPEED/RPMINDICATOR
CS1-F
FREQUENCYINDICATOR
OPERATIONMANUAL
■
DESCRIPTION
CS1-RL(F) controller has been designed simple and low cost with high accuracy
measurement, display, control or communication (Modbus RTU mode) such as
pulse(Frequency) or AC Frequency.
The innovation feature is auto-range input from 0.01Hz~ 100KHz(~140KHz in option). T
he display
resolution will be auto-changed to show the highest according to input frequency.
They have been designed optional 1 of 3 kinds for 1 Relay, 1 Analogue or 1 RS485
port with flexible display function such as max/mini hold, PV hold relative PV…..etc that
very useful in testing equipment and others.Please refer to the detail description on pages
2/38~7/38.
■
FEATURES
●Accuracy: ± 0.005%; Display range: 0~99999; Auto-range with Decimal
Point auto changed according to input frequency.
●1 relay, 1 Analogue output or RS 485 communication port can be
selected one in option
●Relay for Hi / Lo energized with Start Delay / Hysteresis / Energized &
De-energized Delay / Relay Energized Latch…etc functions
●EMC, EMI, LVD Approved & RoHS
【
CS1-RL LINEARLY LINE SPEED / RPM CONTROLLER
】
●Measuring RPM / Linearly line speed / Frequency AUTO RANGE
0.01~100KHz / ~140KHz(optional) / Contact, NPN, PNP, Voltage pulse
can be switch on rear of meter.
【
CS1-F FREQUENCY CONTROLLER
】
●Measuring Frequency AUTO RANGE 0.01~100KHz /
~140KHz(optional) / Voltage pulse or sine wave(specify).
■
APPLICATIONS
Models
●CS1-RL Motor & Machinery / Testing Equipments for Measuring, Alarm or Communication with PC/PLC
On line testing station for appliance, check points of PCB as so on.
●CS1-F Switch Boards / Testing Equipments for Measuring
Functions
●Safety & Protection Hi/Lo alarm and latch(
hIhld
/
lOhld
)
●Testing & Measuring Front Key functiond for Maximum/Minimum hold(
maXhd
/
miNhd
), PV
hold(
pVhld
), Relative PV/Tare/∆PV(
reLpv
)
●Remote Monitoring
RS485 communication port, Display function(rs485)

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
2 / 30
■
FUNCTION DEFINE
■
Character Symbol
Factor function:
Settable range: 0.001~9.999
Display = Value of math with setting x Factor
The display can be proportioned by factor.
The typical application is compensation for gear
ratio.
Auto-range function:
Programmable:
auto
/
semi
/
manul
●
auto
(Auto range):The decimal point will be auto
changed according to the input frequency so that
keep the display in the highest resolution.
Ex.: RPM of Motor: 7200RPM,Encoder: 1000ppr
The meter setting
[pVtyp]
:
rpm
,
[ppr]
:
1000
,
[range]
:
auto
(7200rpm x 1000ppr) / 60 = 120.000kHz
Frequency range is from 0~120.000kHz
The table is between input and display as below,
Freq. Input Display
0Hz
0.0000
RPM
166.65Hz
9.9999
RPM
1666.5Hz
99.999
RPM (Auto change)
16.665kHz
999.99
RPM (Auto change)
16.666kHz
1000.0
RPM (Auto change)
120kHz
7200.0
RPM
The input goes down to
166.65Hz
9.9999
RPM (Auto change)
●
semi
(Semi-Auto range):The decimal point will
be auto changed according to the input frequency
to keep the display in the highest resolution, but it
must be under setting position of decimal point.
It’s possible to show “
ovfl
(overflow)”, if the input
frequency is too high to makeover the display
range.
Ex.: RPM of Motor: 7200RPM,Encoder: 1000ppr
as same as above,
The meter setting
[pVtyp]
:
rpm
;
[ppr]
:
1000
[range]
:
semi
;
[dp]
:
0.00
The table is between input and display as below,
Freq. Input Display
0Hz
0.0000
RPM
166.65Hz
9.9999
RPM (Auto change)
1666.5Hz
99.999
RPM (Auto change)
16.665kHz
999.99
RPM (Auto change)
16.666kHz
ovfl
RPM
120kHz
ovfl
RPM
The input goes down to
16.665kHz
999.99
RPM (Auto change)
A b C d E F G H i J K L M
a b c de f gh i j kl m
n o P q r S t U v W X y Z
no p qr s t u v w x y z
1 2 34 5 6 7 8 90 / .
1234567 8 90/.
■
Input Range & Mode
Input Range & Mode
The meter has been designed very wide input
range from 0.01Hz~100.00KHz(Option:
0.01Hz~140.00KHz) that can cover almost any
application for frequency measuring. User doesn’t
need to specify the input range.
Especially, they do not set the scale to relate
the input range. Users are just set the measuring
type(
pVtyp
) in
[input group].
The display of
meter will show the value that user wants to show
such as RPM, Linearly Line Speed or Frequency.
Please refer to the description of Display Function.
Input mode Switchable
NPN / PNP / Voltage Pulse / Mech. Contact
and amplitude can be switched by switches on
rear of meter.
11
12
14
15
13
Dip
Switch
7
8
9
10
5
6
3
4
DIP SW
1
2
3
4
5
NPN
ON
PNP
ON
M.C.
ON
ON
5V
P
12V
P
ON
24V
P
ON
D-S is on when it is in down site.
*The excitation supply of sensor can not be
changed. Please specify in ordering code.
■
Display Functions
Multi-Display function
Programmable:
lNspd
/
rpm
/
rps
/
hz
/
khz
The meter has desgined for mult-purpose. User
can set the display purpose in
[pVtyp]
of
[input
group]
such as
lNspd
(Linearly Line Speed),
rpm
(RPM),
rps
(RPS),
hz
(Hz),
khz
(kHz) that the meter will display according to the
input and setting to calculate. The meter will show
the relation parameters as below,
●
lNspd
: Pulse/rotation(
ppr
), Engineer Units
(
m/mn
/
cm/mn
/
yd/mn
/
ft/mn
),
Diameter of rotor
diamt
)
●
rpm
/
rps
: Pulse/rotation(
ppr
)
Auto change to
keep highest
resolution
Auto change to
keep highest
resolution

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
3 / 30
In the case of input, the
[dp]
should set
0.0
to display full range of RPM and to get higher
resolution in lower RPM.
●
manul
(Manual range):The decimal point will be
fixed according to the setting of
[dp].
The meter
will show
ovfl
(overflow), once the input goes
over the frequency that is relative 99999.
Ex.: RPM of Motor: 7200RPM,Encoder: 1000ppr
as same as above,
The meter setting
[pVtyp]
:
rpm
;
[ppr]
:
1000
[range]
:
manul
;
[dp]
:
0.00
The table is between input and display as below,
Freq. Input Display
0Hz
0.00
RPM
166.65Hz
9.99
RPM
1666.5Hz
99.99
RPM
16.665kHz
999.99
RPM
16.666kHz
ovfl
RPM
120kHz
ovfl
RPM
The input goes down to
16.665kHz
999.9
RPM
In the case of input, the
[dp]
should set
0.0
to display full range of RPM.
Time out function
Programmable:
auto
/
manul
In the case of low frequency, the meter can not to
identify that is low frequency and no input until the
next pulse input. Sometimes, it takes a long
period.
The meter builds in a time out function to cut out
the display to be “0”.
There are two modes
auto
/
manul
can be
programmed as below,
●
manul
(Manual): There is a period named
ito
(input time out) can be set from 0.0sec~999.9sec.
The display will be “0”, once the next pulse doesn’t
input during the setting time.
●
auto
(Auto): The display will be “0”, once the next
pulse doesn’t input during the time that gave by
formula of meter’s firmware. Gerenally, the auto
time out is 4 times of 1/ frequency of last input
frequency.
Max / Mini recording
In order to review & trace the drifting PV, the
meters will keep the values of maximum and
minimum in
[user level]
during power on.
The maximum and minimum can be reset by front
key function. Please refer to the operation on
description as below.
orange LED will be bright during power on, until
Maximum Hold or Minimum Hold for PV
When the
[dsply]
function in
[input group]
set
to be
maXhd
(Max. Hold) or
miNhd
(Mini. Hold), that
the meter will still display the values of PV in
maximum (or minimum) and the relative square
manual reset by front key in
[user level]
or
Down Key function has been done. The meter will
update immediately new maximum(minimum)
values after press Down Key to reset.
Please paste the sticker
M.H
on the right side of
orange square LED to identify the status of display.
Max. ( Mini.) Hold & Reset
Reset the Max
(Mini) Hold by
Down Key
O
N
Level
Trigger
Maximum Hold
Present
Value
maXh
[dsply]
Mrst
[dNkey]
PV(Present value) Hold
When the
[dNkey]
set to be
pVhld
(PV Hold)
function in
[input group]
, that display will be hold
& kept, and the relative green LED will be bright,
when user press Down Key, until press Down Key
again.
Please paste the sticker
PV.H
ECI
on the
right side of
green square LED to identify the status of display.
PV Hold & Reset
Edge
Trigger
[dNkey]
Present
Value
Reset Data
Hold by
Front Key
PV Hold
1
2
3
4
5
pVhld
Remote display by RS485 command
In past, The meter normally receive 4~20mA or
0~10V from AO card or BCD card of PLC. We
built-in a new solution by RS485 remote display
function which it can save costs of AO and wiring
connecting to PLC simultaneously.
When the
[dsply]
function set to be
rs485
, the
LED display no longer relative to the input signal
then the PV screen will show the data from RS485
command.
Low Cut
Settable range from -19999~+29999 counts.
The users can set a value here to cut the display
value to show "0".
●If the setting value is positive, it expressed the
PV will be 0 which it's within the range of
absolute value;
PV< l Setting value l, the display will be 0
EX: Low Cut is set for 0.50, if the display is from
-0.50~+0.50, that will be 0.
Fix decimal
point resolution

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
4 / 30
Low Cut set to be +0.50
Low Cut is set for 0.50, if the PV is
from -0.50~+0.50, that display will be 0.
PV according
to input signal
Present
Value
Low cut
function
0.50
-0.50
)50
[lOcut]
●If the setting value is negative, it expressed the
PV will be X which it's under the setting value;
PV< Setting value, the display will be X(Setting
value).
EX: Low Cut is set for -0.01, if the display is <
-0.01, and all the display will be -0.01.
Low Cut set to be -0.10
-0.10
Low cut
function
Low Cut is set for -0.10, if the PV is
under (< = -0.10), that display will be -0.10.
Present
Value
PV according
to input signal
-)10
[lOcut]
Digital Fine Adjustment
Settable range from 0~99999 ;
Users can get "Fine Adjustment PV" by front key
on the meter for higher points, and if the user want
to show the current input signals that “Just Key-In”
the value.
Especially, the
[pVspn]
is not only in span of PV,
but also any higher point for
[pVspn]
. The meter
will be linearization automatively for full scale.
The adjustment can be cleared in function
[Sclr]
.
Original display: 1750.0/30Hz
Digital fine adjust.: input 22Hz / 1320.0
New span from1750.0 to1800.0
SCALE
0Hz
30Hz
15Hz
175)0
87%00
)0000
180)0
22Hz
132)0
INPUT
*Please make sure that the
[pVspn]
should be
over 50% of input range. That may be made
bigger error in span, if the interval is too narrow.
Remark: The higher average setting will impact
the
response time of Relay and Analogue
output slower.
The meter’s sampling is 15cycle/sec. If the
[ avg]
(Average) set to be
3
, the meter will
express the sampling 3 readings and calculating
the average then update the display once. At
meantime, the display update will be 5 times/sec.
Average set to be 3
Sample 1
Sample 2
Sample 3
Sample 4
Sample 5
Sample 6
…….
Display Update Value =
(Sample 1 + Sample 2 + Sample 3)/3
Display Update Value =
(Sample 1 + Sample 2 + Sample 3)/3
Digital filter
Settable range from 0(None)/1~99 times.
The digital filter can reduce the influence of
spark noise caused by magnetic of coil.
If the values of samples are over digital filter
band(fix in firmware and about 5% of stable reading)
3 times (Digital Filter set to be 3) continuously, the
meter will admit the samples and update the new
reading. Otherwise, it will be as treat as a noise
and skip the samples.
Digital Filter set to be 3
Digital Filter Band
The values of samples are
two times only, so that the
reading will admit the
samples.
Digital Filter Function
The values of samples are
over the filter band and three
times, so that the reading will
accept the samples, and
update the reading.
Digital Filter Function
Present
Value
■
Front Key Functions
Users can set the
down key of front panel to
be the functions such as Relative PV(Tare)
reLpv
/ PV Hold
pVhld
/ Reset for maxi(mini) hold
Mrst
/
Reset for relay energized latch
rYrst
.
Ex. The
[dNkey]
function set to be
reLpv
in
[input group]
. When user presses
Key, the
PV will show relative value until press
Key
again.
■
Relay Functions
CS1 series offer the 1 relay output with flexible
and versatile functions. They can be programmed
in
[relay group].
Please refer to the description
as following;
Relay energized mode Hi / Lo / Hi.HLd / Lo.HLd
Hi:Relay will be energized when PV > Set Point
(Fig.1-)
Lo:Relay will be energized when PV < Set Point
(Fig.1-)
■
Reading Stable Functions
Average Display update
Settable range: 1~99 times;
Jittery Display caused by the noise or unstable
signal. User can set number to average the
readings to get smoothly display.

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
5 / 30
Hi / Lo Relay Energized
Fig.1
Hi Setting
Hi Relay Energized
ON
Lo Setting
Lo Relay Energized
ON
hi
lo
[ry1.sp]
[ry1.sp]
[ry1.md]
Hi.HLd (Lo.HLd)
The relay energized and latched function is for
electrical safety and human protection.
For example, a current meter installed for over
current alarm of motor. Generally, over current of
motor caused by over load, mechenical dead lock,
aging of insulation and so on. In the case of alarm
of meter, if the user doesn't figue out the real
reason and re-start the motor. It may damage the
motor. The function is desgined that must be
manual reset the alarm after checking out and
solving the issue. It's very important idea for
electrical safety and human protection.
If the PV Higher (or lower) than set-point, the relay
will be energized and latch until manual reset by
from key in
[user level]
.
Hi(Lo) Energized Latch & Reset
Hi.HLd(High latch)
Relay Energized
ON
Reset the relay Hold
by Front Key
ON
Level Trigger
Hi Setting
hIhld
[ry1.md]
rYrst
[ dNkey]
[ry1.sp]
Start delay band and Start delay time
The functions have benn desgined for,
1.To avoid alarm for the starting current of
inductive motor(6 times of rated current).
2.If the
ry_.md
relay energized mode has been set
to be
lo
(Lo) or
lOhld
(Lo & latch), the relay
will be energized, when the meter is power on
and no input due to the "0" display. User can set
a band and delay time to inhibit the energized of
relay.
Start band:(Fig.2-
)
Settable range from 0~9999 Counts
Start delay time: (Fig.2-
)
Settable range from
0.0(second)~9(minutes)59.9(seconds);
Start Delay
Fig.2
Start Delay Time
Start Band
Hi Setting
Relay
Energized
ON
Inhibit
Inhibit
[ rYsb]
[ry1.sp
[ rYsd]
Hysteresis(Fig.3-
)
Settable range from 0~9999 Counts
The function is to avoid the relay on and off
frequently, when the display value is swing near by
the set point. The typical application is to control a
compressor. User can set a band to prevent the
relay on and off frequently.
Relay energized delay(Fig.3-
)
Settable range from
0.0(second)~9(minutes)59.9(seconds);
The function is to avoid the miss action caused by
noise. Sometime, the display value will swing
caused by spark of contactor. User can set a
period to delay the relay energized.
Relay de-energized delay(Fig.3-
)
Settable range from
0.0(second)~9(minutes)59.9(seconds)
Energized / De-energized Delay
& Hysteresis
Fig.3
Energized delay time
ON
Hysteresis
De-energized
delay time
Hi Setting
Relay
Energized
[ry_.sp]
[ry_.hy]
[ry_.rd]
[ry_.fd]
■
Analogue Output Functions
Please specify the output type either a 0~10V
or 4(0)~20mA in ordering. The output low and high
can be programmable which it's related to various
display values. Reverse slope output is possible by
reversing point positions.
[ aOls]
Settable range: -19999~+99999;
Setting the Display value Low to versus output
range Low(as like as 4mA in
A4-20
).
[ aOhs]
Settable range: -19999~+99999;
Setting the Display value High to versus output
range High(as like as 20mA in
A4-20
)
SCALE
Default: [aOls]: 0.00, [aOhs]: 100.00
Change to [aOls]: 50.00, [aOhs]: 19(99
OUTPUT
)00
0.00%
100.00%
50.00%
10)00
5)00
19(99
[aOhs]
[aOls]
*The range between
[ aOhs]
and
[ aOls]
should
be over 20% of span minimum
; otherwise, it will
reflect the less resolution of analogue output.

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
6 / 30
High Limited for Analog Output
Settable range: 0.00~110.00% of output High;
User can set the high limit of output to avoid
destroying the receiver or protection system.
Set Scaling: [lOsc]: )00, [hIsc]: 19(99;
Output: [aOls]: 5)00 (Display value Low),
[aOhs]: 15)00 (Display value High);
[aOlmt]: 8)00%( of Output Range)
0.00%
100.00%
50.00%
OUTPUT
Ao.LMt: 80.00%
80.00%
SCALE
19(99
[hIsc]
)00
[lOsc]
10)00
5)00
[aOls]
15)00
[aOhs]
[aOlmt]
Fine Zero & Span Adjustment for Analog Output
Users can get Fine Adjustment of analogue output
by front key on the meter.
Please connect standard
meter to the terminals of analo
gue output. To press
the front key(up or down key) of meter for adjusting
and checking the output.
[aOzro]
: Fine Zero Adjustment for Analog
Output;
Settable range: -38011~27524;
[aOspn]
: Fine Span Adjustment for Analog
Output;
Settable range: -38011~27524;
■
RS 485 Communication
CS1 series can be used as Remote Terminal
Unit (RTU) for monitoring and controlling in a
SCADA (Supervisor Control And Data Acquisition)
system.
Protocol: ModBus RTU Mode
Baud Rate: Programmable 1200/2400/4800/
9600/19200/38400
Data Bits: 8 bits
Stop Bits: Programmable 1 bit or 2 bits
Parity: Programmable Even / Odd / None
Divice Number: Settable 1~255
Remote Display function
CS1 series has been built in an innovation function
call remote display function.
In past, The meter normally receive 4~20mA or
0~10V from AO card or BCD card of PLC. We
support a new solution by RS485 remote display
function so that can save cost of AO
and wiring into
PLC.
CS1 APPLICATION FOR REMOTE DISPLAY FROM RS485 COMMAND
RS 485 Modbus RTU Mode (up to 38400bps)
RS485 wiring 1.2KM maximum
Terminate Resistor:
RL1
COM
CI11
ENT/FN
◄
▲
▼
Kg
M.H
M.H
RL1
COM
CI11
ENT/FN
◄
▲
▼
RPM
M.H
M.H

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
7 / 30
■
ORDERING INFORMATION
CS1−RL−
Input
Mode
Input
Level
−
Optional
Output
−
Excitation
Supply
−
Aux. Power
CODE
INPUT MODE
CODE
OPTIONAL OUTPUT
CODE
EXCIT. SUPPLY
CODE
AUX. POWER
C
00
Contact
N
None
E05
DC 5V
A
AC 115/230 V
N
NPN
R1
1Relay
E12
DC 12 V
P
PNP
E24
DC 24 V
ADH*
AC/DC 85~264V
V
Voltage pulse
V
0(1) ~ 5 V
0 ~ 10 V
ADL*
AC/DC 20~90V
05
5V pulse
12
12V pulse
I
0 ~ 10 mA
0(4)~20 mA
Theexcitation supplyhas to
match the input mode.The
standardisDC12Vfor12Vp
*ADH* will be available
at Jan. 2008
24
24V pulse
8
RS485
O
xx
Specify
Relay, Analogue Outputor
RS485 Port can be selected
one only.
* It means
RoHS
version.
Input mode and level
can be changed by
dip switches on rear
of meter
OPTION 4
CS1−F−
Input
Mode
Input
Level
−
Optional
Output
−
Excitation
Supply
−
Aux.
Powered
CODE
INPUT
CODE
OPTIONAL OUTPUT
CODE
EXCITATION
CODE
AUX. POWER
V
Voltage pulse
N
None
N
None
A
AC 115/230 V
05
5V pulse
R1
1 Relay
E05
DC 5V
12
12V pulse
V
0(1) ~ 5 V / 0 ~ 10 V
E12
DC 12 V
ADH
AC/DC 85~264V
24
24V pulse
I
0 ~ 10 mA / 0(4)~20 mA
E24
DC 24 V
ADL*
AC/DC 20~90V
S
36
30~600V Sine
RS485
NA
*AC input
O
xx
Specify
* ADH* will be available at
Jan. 2008
Relay, Analogue Outputor RS485
Port can be selected one only
* It means RoHS
version.
OPTION 4
OPTION
■
INSTALLATION
Please check the specification, wire diagrams and functions on the lable of the meter before
installation.
■
Dimensions & Panel Cut Out
■
Installation
96.0
48.0
92.0
+0.2
44.0
+0.2
PANEL CUT-OUT
FRONT VIEW
Unit: mm
8.0
12.0
60.0
Dimensions: 96mm x 48mm x 72mm
Panel Cutout: 92mm x 44mm (advise)
1.0~8.0 mm
FIX HOLDER:
72 mm(L) / W M3
R
COM
ENT/FN
?
?
?
PANEL CUT-OUT:
92
+0.2
(W) x 44
+0.2
(H) mm

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
8 / 30
■
Wiring Diagram
Connector
10A 300Vac, M2.6, 16~22AWG,
Max torque: 5Kg-cm
Please use cord end terminal.
2.0mm max
Please check the voltage of
power supplied first, and then
connect to the specified
terminals. Herein,
recommended that power
supplied to the meter with
protection by a fuse or circuit
breaker.
For input, RS485 wiring,
Herein recommended to use
twin with shielding wire.
RS485 Communication Port
RS485 Port
4
5
6
A
B
Max. Distance: 1200M
Terminate Resistor
(at latest unit):
120~300ohm/0.25W
(typical: 150ohm)
【
CS1-RL RPM/Linearlly Line Speed/Freq.Controller
】
【
CS1-F Frequency Controller
】

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
9 / 30
■
OPERATIONS
■
Front Panel
RL1
COM
CI11
ENT/FN
?
?
?
~A
Comm. status
Relay status
Indication
Operation Key
Front Key
function status
Engineer Unit
Display screen
M.H
Max. Hold status
M.H
Mini. Hold status
Numeric Screens
0.8”(20.0mm) red high-brightness LED for 5 digital
present value.
I/O Status Indicators
Relay Energized: 1 square red LED
RL1
display once Relay 1 has been energized;
RS485 Communication: 1 square orange LED
COM
will flash when the meter is receive or send
data, and
COM
flash quickly means the data
transient quicker.
Max/Mini Hold indication: 2 square orange LEDs
CO
M.H
displayed: To display function which
expressed it has been selected in Maximum or
Minimum Hold function.
Stickers:
Each meter with a sticker to describe what are the
functions and engineer label enclosure.
Functions stickers
Relay energized:
Hi
Hi Energized
Lo
Lo Energized
Hi.H
Hi Energized & Latch
Lo.H
Lo Energized & Latch
Front key functions:
PV Hold
Tare
Digital Input
Maximum or Minimum Reset
Reset fo Relay Latch
Engineer Label: over 80 types.
Operating Key: 4 keys for
Enter(Function) /
Shift(Escape) /
Up key /
Down key
Pass Code:
Settable range:0000~9999;
User must key-in the exactly pass cord for access
to
[
Programming Level
]
. Otherwise, the meter
will return to measuring page. If user forget the
pass code, please contact with your service
window.
Function Lock: There are 4 levels
programmable.
none
(None): no lock at all. User can access to all
level for checking and setting.
user
(User Level): User Level lock. User can
access to User Level for checking, but can not
setting.
eng
(Programming Level): Programming level
lock. User can access to programming level for
checking, but can not setting.
all
(ALL):
All lock. User can access to all level for
checking but can not setting.
Front Key Function
The
Key can be set to be function as like as
Relative PV(Tare) / PV Hold / Reset for
maxi(mini) hold / Reset for relay energized
latch.
Ex. The
[dNkey]
function set to be
reL.pv
in
[input group]
. When user presses
Key, the
PV will show relative value until press
Key
again.

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
10 / 30
■
Error Masage
BEFORE POWER ON, PLEASE CHECK THE SPECIFICATION AND CONNECTION AGAIN.
SELF-DIAGNOSIS AND ERROR CODE:
DISPLAY
DESCRIPTION
REMARK
ovfl
Display is positive-overflow (Signal is over
display range)
(Please check the input signal)
-ovfl
Display is negative-overflow (Signal is under
display range)
(Please check the input signal)
ovfl
ADC is positive-overflow (Signal is higher than
input 120%)
(Please check the input signal)
-ovfl
ADC is negative-overflow (Signal is lower than
input -120%)
(Please check the input signal)
eep
fail
EEPROM occurs error
(Please send back to manufactory for
repaired)
aiCng
pv
Calibrating Input Signal do not process
(Please process Calibrating Input
Signal)
aic
fail
Calibrating Input Signal error (Please check Calibrating Input Signal)
aoCng
pv
Calibrating Output Signal do not process
(Please process Calibrating Output
Signal)
aoc
fail
Calibrating Output Signal error
(Please check Calibrating Output Signal)
■
Operating Key:
*Please access to the Engineer Level to check and set the parameters when users start to run the meter
Operating Key: 4 keys for
Enter(Function) /
Shift(Escape) /
Up key /
Down key
The meter has desgined operation similar as PC's
and
Enter
. In any page, press
key means
"enter" or "confirm setting", and press
key means "escape(
Esc
)" or "shift".
In Engineer Level, the screen will return to Measuring Page after do not press any key over 2 minutes, or
press
for 1 second.
Function Index
Setting Status
(=
)
Enter/Fun key (1) In any page, press
to access
the level or function index
(2) From the function index to
access setting status
(3) Setting Confirmed, save to EEProm and go
to next
function index
(=
)
Shift key (1) In measuring page, press
for 1 second to access user
level.
(2) In function index, press
for 1
second to go back upper level.
(3) In function group index, press
for 1 second to go back
measuring page
(4) In seting status, press
to Shift the setting
position.
(5) In seting status, press
for 1 second to abort
setting and go back this function index.
(=
)
Up key (1) In function index, press
to
go back to previous function
index
(2) In setting status for function, press
to select
function
(3) During number Setting, press
can roll the digit
up
(=
)
Down key (1) In Function Index Page, press
will go to the next Function
Index Page.
(2) In setting status for function, press
to select
function
(3) During number Setting, press
can roll the digit
down.

CS1-RL(F) – Operating Manual(EN) – 2013-01-04
11 / 31
■OPERATING DIAGRAM:
Power on
88888
Self-diagnosis
cs!rl
Model number
cs!rl
:RPM/Linearly
Line speed/
Frequency
cs!f: Frequency
0−0−1
16*88
pv
This page will show
out,when
[dsply]
set
to be
rs485
.
pv
:Present Value
0−3
min
)00
min
:PV minimum
storage
0−6
cs@rl
ver!4
cs@rl
:Model
number
ver!4
:Firmware
version
ver!4
Firmware version
ver!4
: Version 1.4
0−1
ry!sp
10)00
ry!sp
:Relay 1
set-point setting
-19999~+29999
0−4
max
19(99
max
:PV maximum
storage
0−0−1
16*88
pv
Cyclic to first page
16*88
Measuring Page
Press
1sec.
Press
1sec.
0−2
rYrst
no
rYrst
:Reset for
energized latch of
relay
yes
/
no
0−5
Mrst
no
Mrst
:Reset for
minimum and
maximum storage
yes
/
no
Pcode
enter
Enter the password
get into
Programming Level
Password
Default:1000
input
group
INPUT GROUP
relay
group
RELAY GROUP
ao
group
ANALOGUE
OUTPUT GROUP
rs485
group
RS485 GROUP
USER LEVEL
Press
1 second can back to Measuring Page
NO
Press
1 second can back to Measuring
PROGRAMMING LEVEL
YES

CS1-RL(F) – Operating Manual(EN) – 2013-01-04
12 / 31
Password
Default:1000
input
group
INPUT GROUP
input
group
RELAY GROUP
ao
group
ANALOGUE
OUTPUT GROUP
rs485
group
RS485 GROUP
A−1
pVtyp
lNspd
pVtyp
: PV type
selection
lNspd
/
rpm
/
rps
/
hz
/
khz
B−1
rYsb
0
rYsb
: Start band of
relay energized
0~9999 digits
D−1
aOtyp
A4-20
aOtyp
: Analogue
output type and
range selection
V0-10
/
V0-5
/
V1-5
/
A0-20
/
A4-20 / A0-10
E−1
adres
1
adres
: Device
number of the meter
1~255
A−2−1
ppr
1
This function will be
shown, once user
select
lnspd
/
rpm
or
rps
in [
pVtyp
]
ppr
: Pulse/rotation setting
1~99999
B−2
rYsd
)0)0
rYsd
: Start delay
time for relay
energized
0:00.0~9(m):59.9(s)
D−2
aOls
)00
aOls
: The low point
is relative to
analogue output low
-19999~+29999
E−2
baud
9600
baud
: Baud rate
1200
/
2400
/
4800
/
9600
/
19200
/
38400
A−2−2
Eunit
m/mn
This function will be
shown, once user
select
lnspd
in
[
pVtyp
]
Eunit
: Engineer unit of
linearly line speed
m/mn
/
cm/mn
/
yd/mn
/
ft/mn
B−3
ry!md
hi
ry!md
: Relay 1
energized mode
off
/
lo
/
hi
/
lOhld
/
hIhld
/
do
D−3
aOhs
10)00
aOhs
: The high
point is relative to
analogue output
high -19999~+29999
E−3
prity
NstB2
prity
: Parity
Nstb.1
/
Nstb.1
/
odd
/
even
A−2−3
diamt
)1000
This function will be
shown, once user
select
lnspd
in
[
pVtyp
]
diamt
: Diemeter of
rotor
0.0001~+9.9999(M)
B−4
ry!hy
0
ry!hy: Relay 1
hysteresis
0~5000counts
D−4
aOzro
)00
aOzro: Fine zero
adjustment for
analogue low ouput
-38011~+27524
A−3
pVdp
)00
pVdp
: Decimal point
seting
0
/
)0
/
)00
/
)000
/
0.0000
B−5
ry!rd
)0)0
ry!rd: Relay 1
energized delay time
0:00.0~9(m):59.9(s)
D−5
aOspn
)00
aOspn
: Fine span
adjustment for
analogue high ouput
-38011~+27524
Next Page
Next Page
Next Page
PROGRAMMING LEVEL
Press
1 second can back to

CS1-RL(F) – Operating Manual(EN) – 2013-01-04
13 / 31
A−4
factr
!0000
factr
: Factor of
display value
0.001~+9.999
B−6
ry!fd
)0)0
ry!fd
: Relay 1
de-energized delay
time
0:00.0~9(m):59.9(s)
D−6
ZSclr
none
ZSclr
: Clear the
fine zero/span
adjustment for
analogue output
none
/
pVzro
/
pVspn
/
both
A−5
pVspn
0
pVspn
: Fine high point
adjustment for PV
display
-19999~+29999
D−7
aOlmt
11)00
aOlmt
: Analgue
output high limit
0.00~110.00%
A−6
Sclr
no
Sclr
: Clear fine high
points adjustment for
PV display
yes
/
no
A−7
dsply
pv
dsply
: Display function
for PV screen
pv
/
min.Hd
/
maXhd
/
rs485
A−8
lOcut
)00
lOcut
: Low cut the PV
-19999~+29999
A−9
itOmd
auto
itOmd
: Input time out
mode
auto
/
manul
A−10
ito
)0
This function will be
shown, once user
select
manul
in [
itOmd
]
ito
: The time of input
time out
0.0sec~999.9sec
A−11
range
auto
range
: Display range
mode
auto
/
semi
/
manul
※
When by the
RS485 read present
value(PV),can only
choose
manul
A−12
avg
5
avg
: Average update
for PV
1(None)~99times
Next Page

CS1-RL(F) – Operating Manual(EN) – 2013-01-04
14 / 31
A−13
Dfilt
0
Dfilt
: Digital filter
0(None)/1~99times
A−14
dNkey
none
dNkey
: Down key
function
none
/
reLpv
/
pVhld
/
Mrst
/
rYrst
A−15
Pcode
0000
Pcode
: Password
setting for access to
programming level
0000~9999
A−16
Flock
none
Flock
: Function level
lock
none
/
user
/
eng
/
all

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
15 / 30
■Operating Steps:
■User Level
INDEX
FUNCTION DESCRIPTION
PARAMETERS & SETTING
SET
POWER
ON
Please check the specification and
wiring diagrams firstly.
*****
Self-diagnosis (LED All bright)
cs!rl
Model
cs!rl
: RPM/Linearlly Line Speed/ Frequency
cs!f
: Frequency
ver!4
Firmware version
168*8
Measuring Page
Press
for 1 second to access
[
User
Level
]
0−0−1
pv
168*8
This page will show out, when
[dsply]
(step A-7) function has not set
to be
pv
.
pv(Pv): Present Value;
Press
for 1 second return
to Measuring Page
0−1
ry!sp
100)0
100)0
200)0
ry!sp
(rY1.SP):Relay 1 Set-point
◘Please confirm the energized mode of
relay 1 before setting.
Settable range: 0~99999
Shift
Up
Down
Enter
0−2
rYrst
no
no
yes
rYrst
(rY.rSt): Reset for energized
latch
of Relay;
If the
[ry1.md]
(step B-3) set to be
hIhld
or
lOhld
, and the present value(PV)
reach to the condition of relay energising,
the relay will be energized and latching.
At mean time, user can reset the relay
latching in here.
Programmable:
yes
/
no
yes
(Yes): reset the relay
latching.
no
(No): abort to reset the
relay latching.
&
Selection
Enter
◘Be careful, the relay has been
energizing and latching, if the
PV still reach to the condition
of relay energized, enven
user had set here to reset the
relay latching.
0−3
min
)0
min
(Min): the Minimum value of PV
saving;
The meter will save the minimum of PV
during power on, until reset in [
Mrst](step
0-5). It will save newest minimum PV after
reset.
Review only
0−4
max
299(9
max
(Max): the Maximum value of PV
saving;
The meter will save the maximum of PV
during power on, until reset in
[ Mrst]
(
step
0-5). It will save newest maxi
mum PV after
reset.
Review only
Next Page

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
16 / 30
0−5
Mrst
no
no
yes
Mrst
(M.rSt): reset the saved value of
Maximum & Minimum;
The values of maximum and minimum can
be reset in here. It will save newest
maximum and minimum after reset.
Programmable:
yes
/
no
yes
(Yes): to reset the saved
value of maximum and
minimum.
no
(No): abort to reset the
saved values of maximum
and minimum.
&
Selection
Enter
0−6
cs!rl
ver!4
Model of the meters
cs!rl
: RPM/Linearlly Line Speed/ Frequency
cs!f
: Frequency
ver!4
(Ver 1.4): Firmware version
Review only
It will be announced in our
website www.adtek.com.tw,
when it had been versions
updated.
0−0−1
pv
168*8
Return to the first page
Press
for 1 second to back to
Measuring Page in any page.
Programming Level
INDEX
FUNCTION DESCRIPTION
PARAMETERS & SETTING
SET
168*8
MEASURING PAGE
enter
Pcode
Default:1000
0000
1000
Enter the pass code to access
Programming Level
If user wants to change the
pass code, please go to step
A-15 to set. Please remind the
new pass code.
Pass Code
INPUT
GROUP RELAY
GROUP ANALOGUE
OUTPUT
GROUP
RS485
GROUP
PRESS
TO ACCESS
PRESS
TO ACCESS
PRESS
TO ACCESS
PRESS
TO ACCESS
YES
Press
for 1 second to back Measuring Page
NO

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
17 / 30
Input Group
INDEX
FUNCTION DESCRIPTION
PARAMETERS & SETTING
SET
input
group
INPUT GROUP INDEX PAGE In following pages, press
for 1 second to back INPUT
GROUP INDEX PAGE.
A−1
pVtyp
lNspd
lNspd
rpm
pVtyp
: PV type selection
The meter has desgined for
mult-purpose. User can set the display
purpose in
[pVtyp]
of
[input group]
such as
lNspd
(Linearly Line Speed),
rpm
(RPM),
rps
(RPS),
hz
(Hz),
khz
(kHz). The meter will show the
relation parameters as below,
Programmable:
lNspd
:Linearly Line Speed;
rpm
:RPM(Rotation/Minute)
rps
:RPS(Rotation/Second)
hz
:Hz(Frequency)
khz
:kHz(Frequency)
&
Selection
Enter
A−2−1
ppr
1
1
9999
This function will be shown, once
user
selects
rpm
/
rps
or
lNspd
in
[pVtyp]
ppr
: Pulse/rotation setting
Settable range: 1~9999
Shift
Up
Down
Enter
A−2−2
Eunit
m/mn
m/mn
yd/mn
This function will be shown, once
user
selects
lNspd
in
[pVtyp]
Eunit
: Engineer Unit of linearly line
speed
Programmable:
m/mn
/
cm/mn
/
yd/mn
/
ft/mn
m/mn
(M/min): Meter/Minute
cm/mn
(CM/min): Centimeter/Minute
yd/mn
(Yd/min): Yard/Minute
ft/mn
(Ft/min): Feet/ Minute
&
Selection
Enter
A−2−3
diamt
)1000
)1000
(9999
This function will be shown, once
user
selects
lNspd
in
[pVtyp]
diamt
:Diemeter of rotor
Settable range:
0.0001~9.9999M
Shift
Up
Down
Enter
A−3
pVdp
0
0
)0000
pVdp
: Decimal Point setting;
There are two meanning as below,
1.The setting of decimal point is for
set-point of relay energized level
, when
user sets to be
auto
in
[range]
function.
2.The setting of decimal point is for
display value and set-point of relay
energized level, when user sets to be
manul
or
semi
in
[range]
function.
Programmable:
0
/
)0
/
)00
/
)000
/
)0000
&
Selection
Enter
A−4
factr
!000
!000
(999
factr
: Factor of display value
Display = Value of math with setting x
Factor
The display can be proportioned by
factor.The typical application is
compensation for gear ratio.
Settable range: 0.001~9.999
Shift
Up
Down
Enter
Next Page

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
18 / 30
A−5
pVspn
0
00000
20000
pVspn
(Pv.SPn): Fine high point
Adjustment for PV display;
For Span of PV, users can get the "Fine
Adjustment" by front key. It's an
easy way
to “Just Key-In” the value that the user
want to show in the current input signal.
Especially, the
[pVspn]
is not only in
span of PV, but also any higher point for
[pVspn]
. The meter will linearizate
for full
scale.
Settable range: 0~99999
Shift
Up
Down
Enter
Original display: 1750.0/30Hz
Digital fine adjust.: input 22Hz / 1320.0
New span from1750.0 to1800.0
SCALE
0Hz
30Hz
15Hz
175)0
87%00
)0000
180)0
22Hz
132)0
INPUT
A−6
Sclr
no
no
yes
Sclr
(S.CLr): Clear Fine High points
Adjustment for PV display; Programmable:
no
/
yes
no
(No): Do not clear the fine
High adjustment.
yes
(YES): To clear the fine
High adjustment.
&
Selection
Enter
A−7
dsply
pv
pv
maXh
dsply
(dSPLY): Display Function for
PV screen
When the
[dsply]
function set to be
rs485
, At meantime, the display is no
longer express the input signal. The PV
screen
will show the number from RS485
command & data. The data(number) will
be same as PV that it will compare with
set-point, analogue output and ECI
functions so that is to control analogue
output, relay energized and so on.
Programmable:
pv
/
miNhd
/
maXhd
/
rs485
pv
(PV):shows PV
miNhd
(Mini.H): Minimum Hold of
PV
maXhd
(MAX.H): Maximum Hold of
PV
rs485
(RS485): Remote displayed
from RS485 command of
master.
&
Selection
Enter
A−8
lOcut
0
00000
00100
lOcut
(Lo.CUt): Low Cut the PV
If the setting value is positive, it means
the PV is in the range of absolute value
will be 0;
PV≤ I Setting value I
, the display will be 0.
If the setting value is negative, it
expressed the PV will be X which it's
under the setting value;
PV< Setting value, the display will be
X(Setting value).
Settable range: -19999~+29999
Shift
Up
Down
Enter
Low Cut set to be +0.50
Low Cut is set for 0.50, if the PV is
from -0.50~+0.50, that display will be 0.
PV according
to input signal
Present
Value
Low cut
function
0.50
-0.50
)50
[lOcut]
Low Cut set to be -0.10
-0.10
Low cut
function
Low Cut is set for -0.10, if the PV is
under (< = -0.10), that display will be -0.10.
Present
Value
PV according
to input signal
-)10
[lOcut]
Next Page

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
19 / 30
A−9
itOmd
auto
auto
manul
itOmd
: Input Time Out Mode;
In the case of low frequency, the meter
can not to identify that is low frequency
and no input until the next pulse input.
Sometimes, it takes a long period.
The meter builds in a time out function to
cut out the display to be “0”.
Programmable:
auto
/
manul
auto
(Auto): The display will be
“0”, once the next pulse
doesn’t input during the time
that gave by formula of
meter’s firmware. Gerenally,
the auto time out is 4 times of
last frequency of input.
manul
(Manual): There is a
period named
ito
(input
time out) can be set from
0.0sec~999.9sec. The display
will be
“0”, once the next pulse
doesn’t input during the
setting time.
&
Selection
Enter
A−10
ito
)0
)0
%0
This function will be shown, once user
set to be
manul
in
[itOmd]
function
ito
: the time of Input Time Out;
Settable range:
0.0 sec~999.9sec
Shift
Up
Down
Enter
A−11
range
auto
auto
manul
range
: Display Range Mode
※When by the RS485 read present
value(PV), can only choose
manul
Programmable:
auto
/
semi
/
manul
auto
(Auto range):The decimal
point will be auto changed
according to the input
frequency so that keep the
display in the highest
resolution.
semi
(Semi-Auto range):The
decimal point will be auto
changed according to the input
frequency to keep the display
in the highest resolution, but it
must be under setting position
of decimal point. It’s possible
to show “
ovfl
(overflow)”, if
the input frequency is over the
display range.
manul
(Manual range):The
decimal point will be fixed
according to the setting of
[dp].
The meter will show
ovfl
(overflow), once the
input goes over the frequency
that is relative 99999.
&
Selection
Enter
Next Page

CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
20 / 30
A−12
avg
5
05
99
avg
(AvG): Average update for PV
Jittery Display caused by the noise or
unstable signal. User can set number to
average the readings to get smoothly
display.
The meter’s sampling is 15 cycles/sec. If
the
[ avg]
(Average) set to be the
3
,
which means the meter is sampling 3
readings, and calculating the average to
update display once. At meantime, the
display update will be 5 times/sec.
Settable range:
1(no function)~99 times
Shift
Up
Down
Enter
A−13
Dfilt
0
00
99
Dfilt
(d.FiLt): Digital filter
The digital filter can reduce the magnetic
noise or EMI in the field.
If the values of samples are over digital
filter band(fix in firmware and about 5% of
stable reading) 3 times (Digital Filter set to
be 3) continuously, the meter
will admit the
samples and update the new reading.
Otherwise, it will be as treat as a noise
and skip the samples.
Settable range:
0(no function)/1~99 times.
Shift
Up
Down
Enter
A−14
dNkey
none
none
pVhld
dNkey
(dn.key): Down key function
Users can set the
down key of front
panel to be the functions as like as
Relative PV(Tare) / PV Hold / Reset for
maxi(mini) hold / Reset for relay
energized latch.
Programmable:
none
(None):No function
pVhld
(PV.HLd):PV Hold
reLpv
(Rel.PV):Relative PV(∆PV) /
Tare
Mrst
(M.rSt):Reset for Maximum
or Minimum Hold.
rYrst
(rY.rSt):Reset for Relay
energized & latch.
Up
Down
Enter
A−15
Pcode
0000
1000
9999
Pcode
(P.CodE): Pass Code setting for
access to programming level
Please remind and write down the new
pass code so that access to programming
level.
Settable range: 0000~9999
Shift
Up
Down
Enter
A−16
Flock
none
none
all
Flock
(F.LoCk): Function level Lock
There are 4 levels programmable for lock
that the function is to avoid mis-setting.
Programming:
none
(None): no lock at
all. User
can access to user level for
checking and setting.
user
(User Level): User level
lock. User can access to user
level for checking, but can not
setting.
eng
(Programming Level):
Programming level lock. User
can access to programming
level for checking, but can not
setting.
all
(All Level): All lock. User
can access to all level for
checking, but can not setting.
&
Selection
Enter
This manual suits for next models
1
Table of contents
Other ADTEK Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Miele
Miele 07485101 installation instructions

Franklin Electric
Franklin Electric CELLGUARD CGBC-350-HWD install guide

M-system
M-system 40LV instruction manual

eta
eta E63.171 instruction manual

Shenzhen
Shenzhen CTB20A quick start guide

PCB Piezotronics
PCB Piezotronics M352C17/M010AC Installation and operating manual