ADTEK CS3S VA User manual

Voltage/Current Indicator
FEATURE
TECHNICAL SPECIFICATION
Rev 1.2
2017-01-09
CS3S VA-
CS3S VA-
CS3S VA- 1/3
Current
Front Panel
Installation
Dimensions
Operating key Unit lable
Display area
The meter should be installed in a location that does not over
the maximum operating temperature and humidity
and provides good air circulation
Ordering Information
CS3S VA- Input type Input Range AUX Power.
Input Type
D
CODE
A
T
DC
AC
True RMS
Input Range
CODE
CODE AUX.Power
CODE
A1
A2
A3
A4
A5
A6
0~199 9 A. µ
0~1 999mA.
0~19.99mA
0~199.9mA
0~1.999A
0~50.0mV
0~199 9mV.
0~1 999V.
0~19 99V.
0~199 9V.
0~300V
0~1.000A
VA
V1
V2
V3
V4
V5
DC 5V
DC 12V
DC 24V
DC 48V
AC 85 264V~
~DC100 300V
D5
D12
D24
D48
ADH
Current
Voltage
AC 85 264V~
~DC 100 300V
DC
ADH
22.5
5
Input Range
FIX HOLDER
2 PCS
FRONT VIEW
PANEL CUT-OUT
Connection Diagram
Terminal blocks:
SIGNAL
INPUT
Current/Voltage
AUX.POWER
0~199 9 A. µ
0~1 999mA.
0~19.99mA
0~199.9mA
0~1.999A
0~50.0mV
0 1 A. µ
0 001mA.
0 01mA.
0 1mA.
0 001A.
0 1mV.
≦ Ω1K
≦100Ω
≦ Ω10
≦ Ω1
≦.Ω0 05
≧ Ω5M
0~199 9mV.
0~1 999V.
0~19 99V.
0~199 9V.
0~300V
0 1mV.
0 001V.
0 01V.
0 1V.
1V
≧ Ω5M
≧ Ω1M
≧ Ω1M
≧ Ω1M
≧ Ω2M
DC
AC
0 60.0mV~ 0 1mV. ≧ Ω5M
0~1mA
0 100.0mV~
Measuring Range Resolution Input resistance Measuring type
Voltage
0~60.0mV
VB
0~100.0mV
VC
0 001mA. ≦200Ω
0 1mV. ≧ Ω5M
A7 0~1mA
0~1.000A 0 001A. ≦.Ω0 05
CS3S VA-
Operating Key
Parameters
Operating keys : Left (Escape) / key / Down key / Enter(Function) keyUP
In setting page,the screen will return to measuring screen after do not press any key over 2 minutes, or press
and hold 2 seconds
Enter/Function
key
Shift key
Up key
Down key
Function Index
(1) In any page press for into,
,(2) In function index page press for setting (3) Setting Confirmed and save
(1) Press and hold 2 seconds to go back
previous page
(2) In setting page press and hold 2 seconds to go back previous page and,
without save
(3) In number setting press for shift the setting position,
( )1 Press for back to previous function index (2) In parameters setting press for item select,
(3) In number setting press for increase number,
(1)Press for go to next function index
(2) In parameters setting press for item select,
(3) In number setting press for decrease number,
Parameter Explanation Range
aIlo
aIhi
pVdp
lOsc
hIsc
pVzro
pVspn
PSclr
lOcut
avg
mVavg
DFilt
AILO
AIHI
PVDP
LOSC
HISC
PVZRO
PVSPN
PSCLR
LOCUT
AVG
MVAVG
DFILT
Analogue input low limit setting
Decimal point setting of PV
Low scale setting
High scale setting
PV fine adjustment of zero
Clear fine adjustment of zero/span
Low cut setting
Average setting for reading
Moving average setting for reading
Digital filter setting for reading
MAX
MIN
M.RST
Maximum value
Maximum and Minimum value reset
Model name and version
max
min
m.rst
Rev 1.2
2017-01-09
2 3/
CS3S VA-
DC AC / True RMS
0.00~100.00%
0.00~100.00%
0 0.0 0 00 0 000、 、 .、.
-1999~9999
-1999~9999
- ~1999 9999
- ~1999 9999
NONE PVZRO PVSPN BOTH、 、 、
- ~1999 9999
1~99 time
1~10 time
0(None /1 99 time) ~
Read only
YES / NO
VA
0.00~100.00%
0.00~100.00%
0 0.0 0 00 0 000、 、 .、.
0000~9999
0000~9999
0000 9999~
0000 9999~
0000 9999~
1~99 time
1~10 time
0(None /1 99 time) ~
YES / NO
VA
init INIT Meter initialize 7170 7170
Pcode PCODE Pass code setting 0000~9999 0000~9999
NONE PVZRO PVSPN BOTH、 、 、
type TYPE
Parameters Setting
Read only
Read only
Read only
Analogue input high limit setting
PV fine adjustment of span
Minimum value
CS3S VA-
Power On
enter
Pcode
aIlo
0.00
aIhi
100.00
Analogue
input low
limit setting
0 00 100 00. ~ .
Analogue
input high
limit setting
0 00 100 00. ~ .
pVdp
0
lOsc
0
Decimal point
setting of PV
0 0 0、.、
0 00 0 000. 、.
Low scale
setting
- ~1999 9999
hIsc
9999
pVzro
0
pVspn
0
High scale
setting
- ~1999 9999
PV fine
adjustment of
zero
- ~1999 9999
PV fine
adjustment of
span
- ~1999 9999
PSclr
none
lOcut
0
Clear fine
adjustment of
zero/span
none pvzro、
pvspn both、
Low cut
setting
- ~1999 9999
avg
5
mVavg
1
Average setting
for reading
1~99 time
Moving average
setting for
reading
1~10 time
DFilt
0
Pcode
0000
max
0
Digital filter setting
for reading
0 None)/1~99 time(
Pass code
setting
0000 9999~
Maximum
value
min
0
Mrst
no
Maximum and
Minimum value
reset
yes no、
va
ver1.1
init
0000
Model name
and version
Meter initialize
7170
Minimum
value
aIlo
0.00
aIhi
100.00
Analogue
input low
limit setting
0 00 100 00. ~ .
Analogue
input high
limit setting
0 00 100 00. ~ .
pVdp
0
losc
0
Low scale
setting
0000 9999~
hIsc
9999
pVzro
0
pVspn
0
High scale
setting
0000 9999~
PV fine
adjustment of
zero
0000 9999~
PV fine
adjustment of
span
0000 9999~
PSclr
none
lOcut
0
Low cut
setting
0000 9999~
avg
5
mVavg
1
DFilt
0
Pcode
0000
max
0
Digital filter setting
for reading
0 None)/1~99 time(
Pass code
setting
0000 9999~
Maximum
value
min
0
Mrst
no
Maximum and
Minimum value
reset
yes no、
ver1.1
init
0000
Model name
and version
Meter initialize
7170
Minimum
value
Rev 1.2
2017-01-09 CS3S VA- 3/3
D C I n p u t
88888. . . .
CS3 5.
ver1.1
Correct ?
Self-diagnosis
Model name
Model version
0
Measuring page
Input pass code
Default 1000:
Press 2 seconds back to Measuring Page
NO
YES
Decimal point
setting of PV
0 0 0、.、
0 00 0 000. 、.
Clear fine
adjustment of
zero/span
none pvzro、
pvspn both、
Average setting
for reading
1~99 time
Moving average
setting for
reading
1~10 time
va
va
Model name
D C I n p u t A C I n p u t
Operating Diagram

Other ADTEK Measuring Instrument manuals

ADTEK CS2-SG User manual

ADTEK

ADTEK CS2-SG User manual

ADTEK CS2-SG User manual

ADTEK

ADTEK CS2-SG User manual

ADTEK CS1-SG User manual

ADTEK

ADTEK CS1-SG User manual

ADTEK CPM-12D User manual

ADTEK

ADTEK CPM-12D User manual

ADTEK CS2-MC User manual

ADTEK

ADTEK CS2-MC User manual

ADTEK MWH-10 User manual

ADTEK

ADTEK MWH-10 User manual

ADTEK MWH-10A User manual

ADTEK

ADTEK MWH-10A User manual

ADTEK CPM-12B User manual

ADTEK

ADTEK CPM-12B User manual

ADTEK CM1 Series User manual

ADTEK

ADTEK CM1 Series User manual

ADTEK MW-5 User manual

ADTEK

ADTEK MW-5 User manual

ADTEK AEM-DRK User manual

ADTEK

ADTEK AEM-DRK User manual

ADTEK CPM-12D User manual

ADTEK

ADTEK CPM-12D User manual

ADTEK AEM-DRB User manual

ADTEK

ADTEK AEM-DRB User manual

ADTEK NED User manual

ADTEK

ADTEK NED User manual

ADTEK CS1 Series User manual

ADTEK

ADTEK CS1 Series User manual

ADTEK CS3S-TR User manual

ADTEK

ADTEK CS3S-TR User manual

ADTEK CS1-PR User manual

ADTEK

ADTEK CS1-PR User manual

ADTEK CM1-TC User manual

ADTEK

ADTEK CM1-TC User manual

ADTEK CPM-12A User manual

ADTEK

ADTEK CPM-12A User manual

ADTEK CPM-10 User manual

ADTEK

ADTEK CPM-10 User manual

ADTEK CS1-RL User manual

ADTEK

ADTEK CS1-RL User manual

ADTEK AFM-8A User manual

ADTEK

ADTEK AFM-8A User manual

ADTEK CS2-VA User manual

ADTEK

ADTEK CS2-VA User manual

ADTEK CPM-80 Series User manual

ADTEK

ADTEK CPM-80 Series User manual

Popular Measuring Instrument manuals by other brands

METREL EurotestXE instruction manual

METREL

METREL EurotestXE instruction manual

Extech Instruments RPM33 user guide

Extech Instruments

Extech Instruments RPM33 user guide

UEi DL389B instruction manual

UEi

UEi DL389B instruction manual

turck IM21-14Ex-CDTRi manual

turck

turck IM21-14Ex-CDTRi manual

KMC Controls rc allen instruments RCA 2610-P Series Installation & operation guide

KMC Controls

KMC Controls rc allen instruments RCA 2610-P Series Installation & operation guide

sauter SN instruction manual

sauter

sauter SN instruction manual

Keysight U8903A How to Do

Keysight

Keysight U8903A How to Do

ATIM ACW/SF8-WL-I user guide

ATIM

ATIM ACW/SF8-WL-I user guide

AEMC 1026 user manual

AEMC

AEMC 1026 user manual

TESTO 550 quick start guide

TESTO

TESTO 550 quick start guide

Adam Pumps DI-FLOW IN-LINE Diesel Use and maintenance manual

Adam Pumps

Adam Pumps DI-FLOW IN-LINE Diesel Use and maintenance manual

JUMO B 90.7023.1 operating instructions

JUMO

JUMO B 90.7023.1 operating instructions

horiba D-72 instruction manual

horiba

horiba D-72 instruction manual

Campbell Weatherpak M product manual

Campbell

Campbell Weatherpak M product manual

palintest Lumiso Pooltest Expert quick start guide

palintest

palintest Lumiso Pooltest Expert quick start guide

Squirrel CORVID user manual

Squirrel

Squirrel CORVID user manual

MADDALENA microCLIMA ULTRA Installation and operating instructions

MADDALENA

MADDALENA microCLIMA ULTRA Installation and operating instructions

Keysight N9030B Installation note

Keysight

Keysight N9030B Installation note

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.