EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Arjo
  6. •
  7. Medical Equipment
  8. •
  9. Arjo Miranti User manual

Arjo Miranti User manual

Other manuals for Miranti

4

This manual suits for next models

3

Other Arjo Medical Equipment manuals

Arjo CARENDO Operating instructions

Arjo

Arjo CARENDO Operating instructions

Arjo MAXI SKY 600 Installation guide

Arjo

Arjo MAXI SKY 600 Installation guide

Arjo AtmosAir Velaris User manual

Arjo

Arjo AtmosAir Velaris User manual

Arjo Evenda EV-ACC12 User manual

Arjo

Arjo Evenda EV-ACC12 User manual

Arjo Maxi Air User manual

Arjo

Arjo Maxi Air User manual

Arjo MAXI MOVE Operating instructions

Arjo

Arjo MAXI MOVE Operating instructions

Arjo Century User manual

Arjo

Arjo Century User manual

Arjo MAXI MOVE User manual

Arjo

Arjo MAXI MOVE User manual

Arjo Flowtron ACS900 User manual

Arjo

Arjo Flowtron ACS900 User manual

Arjo Enterprise ENT-ACC05 User manual

Arjo

Arjo Enterprise ENT-ACC05 User manual

Arjo AtmosAir User manual

Arjo

Arjo AtmosAir User manual

Arjo Alpha Active 5 User manual

Arjo

Arjo Alpha Active 5 User manual

Arjo Flowtron Excel User manual

Arjo

Arjo Flowtron Excel User manual

Arjo MAXI MOVE User manual

Arjo

Arjo MAXI MOVE User manual

Arjo Maxi Sky 2 User manual

Arjo

Arjo Maxi Sky 2 User manual

Arjo Maxi Sky 2 PLUS User manual

Arjo

Arjo Maxi Sky 2 PLUS User manual

Arjo Enterprise ENT-ACC06 User manual

Arjo

Arjo Enterprise ENT-ACC06 User manual

Arjo Sara 3000 Installation guide

Arjo

Arjo Sara 3000 Installation guide

Arjo Auralis User manual

Arjo

Arjo Auralis User manual

Arjo Huntleigh Sonicaid Team3 USA User manual

Arjo

Arjo Huntleigh Sonicaid Team3 USA User manual

Arjo Dual-Loop Attachment Straps User manual

Arjo

Arjo Dual-Loop Attachment Straps User manual

Arjo AtmosAir 4000 Series User manual

Arjo

Arjo AtmosAir 4000 Series User manual

Arjo Alenti User manual

Arjo

Arjo Alenti User manual

Arjo AtmosAir Velaris User manual

Arjo

Arjo AtmosAir Velaris User manual

Popular Medical Equipment manuals by other brands

TekTone Tek-CARE160 Installation and operation manual

TekTone

TekTone Tek-CARE160 Installation and operation manual

NeuroMetrix Quell 2.0 user manual

NeuroMetrix

NeuroMetrix Quell 2.0 user manual

AMT XLR8 Quick reference guide

AMT

AMT XLR8 Quick reference guide

EDAN SONOTRAX Pro user manual

EDAN

EDAN SONOTRAX Pro user manual

Restorative Therapies RT300 Service guide

Restorative Therapies

Restorative Therapies RT300 Service guide

Gendex Expert DC installation manual

Gendex

Gendex Expert DC installation manual

Dexcowin ADX4000W user manual

Dexcowin

Dexcowin ADX4000W user manual

Libelium MySignals user manual

Libelium

Libelium MySignals user manual

Acelity V.A.C.ULTA 4 user manual

Acelity

Acelity V.A.C.ULTA 4 user manual

Caputron ActivaDose II tDCS quick start guide

Caputron

Caputron ActivaDose II tDCS quick start guide

Plinth 2000 93CDT Service manual

Plinth 2000

Plinth 2000 93CDT Service manual

GE SENOGRAPHE 800T Operator's manual

GE

GE SENOGRAPHE 800T Operator's manual

GE Definium 5000 Operator's manual

GE

GE Definium 5000 Operator's manual

Kanmed GE-1380 user manual

Kanmed

Kanmed GE-1380 user manual

Huntleigh FD1 Instructions for use

Huntleigh

Huntleigh FD1 Instructions for use

Stryker SPR Plus Operation manual

Stryker

Stryker SPR Plus Operation manual

Tobii Dynavox I-Series user manual

Tobii Dynavox

Tobii Dynavox I-Series user manual

S-Capepod Evac Cocoon Step-by-step guide

S-Capepod

S-Capepod Evac Cocoon Step-by-step guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Removing visual residue
Position the hygiene lift over the bathtub
and lower it.
Miranti: Remove headrest, thigh support cushion,
patient security grip and safety belts.
Bolero: Remove mattress and safety belts.
Alenti: Remove backrest and safety belt.
Calypso: Remove seats, seat insert, backrest and
safety belt.
Place the accessories at the bottom of the bath tub.
Clean from visible residue using a cloth soaked in water or by
showering with water and scrubbing with a brush. Clean the
hygiene lift from the top and move downwards.
Clean all removed parts.
21 3
NOTE
The cleaning and disinfection procedure is illustrated with Miranti and an integrated disinfection
system as an example.
WARNING
To avoid eye and skin damage, always use protective glasses and gloves. If contact occurs rinse with
plenty of water. If eyes or skin becomes irritated, contact a physician. Always read the Instructions for
Use and the Safety Data Sheet (SDS) of the disinfectant.
To prevent cross-contamination, always follow the disinfection instructions in the Instructions for Use.
To avoid eye or skin irritation, never disinfect in the presence of a patient.
Continue with the steps on the next page
Clean and disinfect daily.
Clean and disinfect before next patient.
Accessories needed:
• Protective gloves
• Protective glasses
• Spray bottle with disinfectant (if integrated
disinfection system is not available)
• Spray bottle (or shower handle) with water
• Cloths - wet and dry
• Disposable towels
• Soft-bristled brush
• Long-handled, soft-bristled brush
QUICK REFERENCE GUIDE - CLEANING AND DISINFECTION
Miranti, Bolero, Alenti, Calypso
08.CE.06EN_1 • 06/2020 • Page 1/3
Cleaning
!
Wet a new cloth with water and
remove all traces of disinfectant
on other areas. The cloth should
occasionally be rinsed in running
water.
If all disinfectant cannot be removed, spray
with water on the affected part and wipe off
with disposable towel until all disinfectant is
removed.
910
Soak a cloth in disinfectant and
wipe all other areas.
8
Spray disinfectant on the hygiene lift and on all removed
parts.
Use a spray bottle with disinfectant or use the bath’s
integrated disinfection system.
Scrub thoroughly with a brush soaked in disinfectant, especially on
handles, hand control, hinges and the underside of the hygiene lift.
Shower with water (approx. 25 °C
(77 °F)) or spray with water and wipe with
a clean cloth.
56
7
Put on protective gloves and
glasses.
4
Read the separate
instructions for
disinfection system
and disinfectant
used
Continue with the steps on the next page
08.CE.06EN_1 • 06/2020 • Page 2/3
Disinfection
!
Let all parts dry.
If all disinfectant cannot be removed, spray
with water on affected parts and wipe off with
disposable towel until all disinfectant is removed.
Soak a cloth in disinfectant and wipe all other
areas.
Allow a disinfection time according to the instructions of
disinfectant.
Shower or spray with water and wipe with a clean
cloth to remove all traces of disinfectant from the
hygiene lift, chassis and all removed parts. The cloth
should occasionally be rinsed in running water.
Spray disinfectant on the hygiene lift and on all
removed parts.
11 12 13
14 15 16
?
08.CE.06EN_1 • 06/2020 • Page 3/3
ArjoHuntleigh AB
Hans Michelsensgatan 10
211 20 Malmö, Sweden
www.arjo.com