manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Aseptico
  6. •
  7. Dental Equipment
  8. •
  9. Aseptico ADU-07A Administrator Guide

Aseptico ADU-07A Administrator Guide

This manual suits for next models

1

Other Aseptico Dental Equipment manuals

Aseptico ADC-08 User manual

Aseptico

Aseptico ADC-08 User manual

Aseptico ALU-40LED-CF Manual

Aseptico

Aseptico ALU-40LED-CF Manual

Aseptico ADU-12DCEB Task Force Deluxe Manual

Aseptico

Aseptico ADU-12DCEB Task Force Deluxe Manual

Aseptico AEU-14CF User manual

Aseptico

Aseptico AEU-14CF User manual

Aseptico AEU-26OS Manual

Aseptico

Aseptico AEU-26OS Manual

Aseptico ADU-17A2 Express Air 2 Manual

Aseptico

Aseptico ADU-17A2 Express Air 2 Manual

Aseptico VCT AEU-925 Manual

Aseptico

Aseptico VCT AEU-925 Manual

Aseptico ADC-01 AseptiChair User manual

Aseptico

Aseptico ADC-01 AseptiChair User manual

Aseptico ADC-02CF User manual

Aseptico

Aseptico ADC-02CF User manual

Aseptico ADU-03ST Manual

Aseptico

Aseptico ADU-03ST Manual

Aseptico ALU-40LED Manual

Aseptico

Aseptico ALU-40LED Manual

Aseptico ADC-01C User manual

Aseptico

Aseptico ADC-01C User manual

Aseptico AEU-525CF Transport III Troubleshooting guide

Aseptico

Aseptico AEU-525CF Transport III Troubleshooting guide

Aseptico AEU-7000L-70V Manual

Aseptico

Aseptico AEU-7000L-70V Manual

Aseptico Task Force Deluxe Manual

Aseptico

Aseptico Task Force Deluxe Manual

Aseptico AMC-20CF Manual

Aseptico

Aseptico AMC-20CF Manual

Aseptico ADU-17A Manual

Aseptico

Aseptico ADU-17A Manual

Aseptico Command Air ADC-08CF User manual

Aseptico

Aseptico Command Air ADC-08CF User manual

Aseptico AEU-5000 Manual

Aseptico

Aseptico AEU-5000 Manual

Aseptico ADC-08-RED Manual

Aseptico

Aseptico ADC-08-RED Manual

Aseptico AMC-15 Manual

Aseptico

Aseptico AMC-15 Manual

Aseptico AEU-25 Manual

Aseptico

Aseptico AEU-25 Manual

Aseptico ADC-01P-RED AseptiChair User manual

Aseptico

Aseptico ADC-01P-RED AseptiChair User manual

Aseptico ADU-03ST Manual

Aseptico

Aseptico ADU-03ST Manual

Popular Dental Equipment manuals by other brands

3M ESPE Pentamix Lite operating instructions

3M ESPE

3M ESPE Pentamix Lite operating instructions

ENBIO Enbio S user manual

ENBIO

ENBIO Enbio S user manual

Vatech EzRay Air VEX-P300 user manual

Vatech

Vatech EzRay Air VEX-P300 user manual

KaVo GENTLEpower LUX Contra-angle 25 LP Technician's Instructions

KaVo

KaVo GENTLEpower LUX Contra-angle 25 LP Technician's Instructions

DENTSPLY SmartLite Focus Instructions for use

DENTSPLY

DENTSPLY SmartLite Focus Instructions for use

LM ProPower CombiLED quick guide

LM

LM ProPower CombiLED quick guide

Owandy Radiology RX-AC user manual

Owandy Radiology

Owandy Radiology RX-AC user manual

mectron Piezosurgery Cleaning and sterilization manual

mectron

mectron Piezosurgery Cleaning and sterilization manual

Belmont CREDIA G1 operating instructions

Belmont

Belmont CREDIA G1 operating instructions

Planmeca Sovereign Classic user manual

Planmeca

Planmeca Sovereign Classic user manual

Bego Fornax T operating instructions

Bego

Bego Fornax T operating instructions

Renfert SYMPRO Operating and safety instructions

Renfert

Renfert SYMPRO Operating and safety instructions

Nevadent NZPS 3 A1 operating instructions

Nevadent

Nevadent NZPS 3 A1 operating instructions

Dentatus Nyström instruction manual

Dentatus

Dentatus Nyström instruction manual

OMS DUKE EASY Instruction handbook

OMS

OMS DUKE EASY Instruction handbook

OMS LINEA PATAVIUM Instruction handbook

OMS

OMS LINEA PATAVIUM Instruction handbook

BRYANT DENTAL Ignis Gesture A-494322 manual

BRYANT DENTAL

BRYANT DENTAL Ignis Gesture A-494322 manual

Renfert Basic classic instruction manual

Renfert

Renfert Basic classic instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

OPERATION
INSTRUCTION MANUAL
ADU-07A ECONO AIR SYSTEM
Your new Aseptico ADU-07A Econo Air System is one of the finest handpiece control systems
available to the professional. This economic system provides dental operatories, hygienists’
rooms or satellite offices with three automatically activated handpiece controls — simply lift the
handpiece from its holder to activate.
.Congratulations!
This system is engineered to provide many years of reliable service. Please read the instructions
provided in this manual to receive the best and longest service from your Aseptico equipment.
INSTALLATION:
Before you install your ADU-07A unit, locate a
suitable mounting surface that has access to a
clean, filtered air and water supply.
1. Remove the chassis back from the front by
unscrewing the 6-32 x 1/4 holding screws.
2. Use the mounting holes on the back of the
chassis as a marking template and secure
the chassis back to a flat vertical surface.
Then reattach the front of chassis to the
mounted back. (Fig. 1)
3. Locate the 1/4" grey air supply line and the
blue water supply line exiting from beneath
the ADU-07 console. Connect the grey air
supply line to a clean regulated 60-90 PSI
compressed air supply. Connect the blue
water supply line to a clean regulated
water source such as the tap water supply
or a remote self-contained water system.
(Fig. 2).
Figure 1 - Chassis Mounting
BLUE
TO WATER SUPPLY
TO COMPRESSED
AIR SUPPLY
GREY
Figure 2 - Water & Air Connections
WATER FLOW
ON/OFF
SWITCH
Figure 3 - Foot Control
UNIT OPERATION:
1.Handp eces (sold separately) - Connect
the proper highspeed and lowspeed
handpieces to their appropriate connectors.
Lift handpiece from holder to automatically
activate. Depress foot control for
operation.
2. 3-Way A r/Water Syr nge - Depress the
right button for air operation, and the left
button for water operation. Depressing
both buttons will create a mist. The syringe
features quick-change autoclavable tips:
To remove a tip, press the locking ring
surrounding the tip socket and pull the
used tip straight out of the socket (Fig. 5).
To insert a new tip, press locking ring and
push tip into socket as far as it will go.
Release ring and gently tug on tip before
using to ensure that tip is securely locked
into socket.
Syr nge T p Ster l zat on:
1) Remove contaminated syringe tip.
2) Remove all visible signs of
contamination before autoclaving.
3) Autoclave tip at 132° C (270° F) for ten
minutes.
4) Sterilize between each patient use.
NOTE: Since only the tips can be
autoclaved, it is recommended that the
air/water syringe be bagged with a
disposable, single-use plastic sleeve
between each patient use.
OPERATION FUNCTIONS:
(See Fig res 3 & 4)
1. Handp ece Selectors - Automatically
activates highspeed or lowspeed
handpieces when lifted from their holders.
2. Pressure Guage - Provides visual
indication of drive air pressure for the
handpiece in use.
3. Dr ve A r Pressure Controls - Adjusts
drive air pressure to the highspeed and
lowspeed handpieces. Turn controls
clockwise (with small slot-head
screwdriver) to decrease pressure;
counterclockwise to increase pressure.
4. A r/Water Syr nge - Delivers air, water, or
a combination mist. Supplied with
autoclavable tips.
5. Water Flow Controls - Adjusts water
coolant flow to the highspeed handpieces.
6. Foot Control w/Water On/Off Sw tch -
Wet/dry type foot control provides drive air
pressure to the active handpiece. Apply
light foot pressure to any part of the foot
control cover. Toggle Sw tch provides
on/off control of water coolant flow to
highspeed handpieces (Fig. 3).
PRESSURE
GUAGE
DRIVE AIR
PRESSURE
CONTROLS
HIGHSPEED
HANDPIECE
SELECTORS
LOWSPEED
HANDPIECE
SELECTOR
WATER FLOW
CONTROLS
(Underneath
Console)
AIR/WATER
S RINGE
Figure 4 - Console
Figure 5 - Tip Removal & Installation
DEPRESS
LOCKING RING
P/ : 420424
Rev. D
ECO: 14684
03/2019
PRI TED I  THE U.S.A.
P.O. Box 1548 Woodinville, WA 98072
8333 216th Street SE Woodinville, WA 98072
(425) 487-3157 (800) 426-5913
www.aseptico.com • [email protected]
Aseptico warrants its products against defects in material or workmanship
for a period of two (2) years, from date of original invoice. Some
handpieces are warranted for one year under the same conditions. Other
handpieces and expendable components, such as air turbines and light
bulbs, are covered by shorter warranty periods, or have no warranty.
Aseptico's sole obligation under product warranty is (at its sole option and
discretion) to repair or replace any defective component or product in part
or whole. Aseptico shall be the sole arbiter of such action.
In the event of alleged defect under warranty, the purchaser is to notify
Aseptico's Customer Service Department promptly. Customer Service will
provide instructions, usually directing that the product be returned for
service. Shipment to Aseptico and the cost thereof is always the
responsibility of the purchaser.
Accidental misuse, inappropriate installation, or failure to perform directed
maintenance voids the warranty. Deliberately defacing, modifying, or
removing the serial number voids the warranty.
Aseptico does not assume, under this warranty, any risks or liabilities
arising from the clinical use of its products, whether or not such use
involves coincidental utilization of products manufactured by others.
WARRANTY:.