Installation and Technical Information
BEGA
Accessories
Please refer to the appropriate
accessory installation sheet for
further instruction when applicable.
Replacement Parts
Luminaire Base
Wiring Box
Adapter Plate
Figure 1:
Figure 2:
Set Screws
Surface wall with shielded light source 33 539
Tools Required:
2mm hex key
11/32” Nut driver
Phillips medium screwdriver
Small Flathead screwdriver
Protection Class: IP64
Weight: 1.0 lb.
Dimensions
A: 3 ”
B: 5-1/8 ”
C: 3 1/4 ”
Relamping/Maintenance
Loosen (2) 2mm set screws under luminaire and
remove outer casting with lens. Clean luminaire and
lens using only solvent-free cleansers. Replace lens
and outer casing, making sure that the gasket is
seated properly.
Lamp: 3.2W LED
Description
Lens
Lens gasket
Driver (120-277V) (X1)
LED module (3000K) (X1)
LED module (4000K) (X1)
Part No
140787
831223
75911
LED-0684/830
LED-0684/830
Notice to Installer for 33 539:
1. See page 2 for specic product safety warnings.
2. Mounts directly to a standard single-gang recessed wiring box (by others) using
adaptor plate (supplied).
3. In conformance with UL Standard 1598, a silicone based sealant must be used
between luminaire and supporting wall.
IMPORTANT:
SILICONE RTV MUST BE APPLIED ON BOTH SIDES OF THE ADAPTOR PLATE
TO ENSURE AGAINST WATER INTRUSION.
33 539 - Installation:
1. Using a small athead screwdriver, loosen (2) set screws under luminaire and
remove outer casting with lens. [Figure 1]
2. Feed luminaire wires through luminaire base and adaptor plate wireway hole.
3. Make supply wiring and luminaire wiring connections in the wiring box:
MAIN VOLTAGE SUPPLY WIRE TO BLACK LUMINAIRE WIRE
NEUTRAL (COMMON) SUPPLY WIRE TO WHITE LUMINAIRE WIRE
4. Place a bead of silicone RTV around the outer edge of the back side of the
adaptor plate that will come in contact with the nished wall
(exterior applications only).
5. Attach adaptor plate to single-gang wiring box using (2) wiring box screws.
6. Apply silicone RTV to outside edge of luminaire base and mount luminaire base
to adaptor plate using (2) screws (provided).
IMPORTANT: Note position of orientation arrow on luminaire base and install
accordingly.
7. Replace outer casting and tighten (2) set screws, making sure the gasket is
seated properly.
In the interest of product improvement, BEGA reserves the right to make technical changes without notice.
BEGA 1000 Bega Way, Carpinteria, CA 93013 (805)684-0533 Fax (805)566-9474 www.bega-us.com © Copyright BEGA-US 2019 33 539
07/15/2019
1 of 2