The Flexo.Code impresses with its versatile application and
installation options. The innovative design lock offers the
possibility of individual time control with adjustable closure
duration and up to 999,999 code variants.
Like all locks in the Flexo range, the code variant allows both
recessed installation (flush fit) and retrofitting (retro fit). Thanks
to the possible one-, two- or three-point locking with latch
function, it adapts conveniently to any installation situation.
Important: Please observe all warnings and read through
the entire operating instructions before you begin with
the configuration.
Introduction
The latest version of this guide is available at:
www.burg.de
General
Flexo.Code
Introduction 2
General 2
Technical data 3
Scope of delivery 3
Optional accessories 3
Default settings 3
Features 3
Product dimensions 3
Functional description 4
Assembly flush fit 5
Assembly retro fit 6
Configuration 7
Operation 8
Battery replacement 8
Disposal and battery note 8
Content
B
ALED Btouchpad keys
Cclosure hole Dbattery compartment
Ebattery Fknob
Ghousing
A
D
EF GC
C

Flexo.Code | 01-2023 Rev. 01 | English | 3
Dimension Ø 50 mm
Battery VARTA11/2 AA (2x)
Locking cycles1 30,000
Working temperature -20° C to 55° C
rel. humidity: 10% - 85%
No. of code combinations 999,999
Code length 4 or 6 digits
Mode Multi User Mode,
Private Mode
Material Housing: plastic
Cam: steel
Mounting dimension 16 mm x 19 mm
Locking direction Left (90°), door hinge: DIN right
Lock attachment M19 nut (1x)
Cam type B
Max. door thickness 22 mm
Factsheet
Technical Data
Front view Back view
ergonomic handling and high-quality design
external battery access and battery replacement
time-controlled unlocking and locking
easy to retrofit, e.g. for replacement of mechanical locks
adjustable cam (in 90° steps)
Features
Optional Accessories
anti-twist protection (W-MSZ-01)
opening pin
Flexo.Ring + fixing nut
Product Dimensions
Front view
Side view
retro fit flush fit
5
123
4
789
0
6
50 mm
43 mm
38,4 mm
50 mm
15 mm
50 mm
Master Code 934716
Mode Multi User Mode
Code length 4 digits
Locking Manually
LED locking indication On
Code confirmation Off
Default Settings
Scope of Delivery
1x locking system
1x cam fixing screw2M6 x 12 mm
1x M19 nut
cam type B
for single packaging:
1x length 53 mm, without crank (1-36 RIH-501 G)
1x length 40 mm, crank 3 mm (1-36 RIH-514 K)
1x length 40 mm, cranking 6 mm (1-36 RIH-515 K)
for industry packaging: order related
1 The lock is approved for VARTA brand batteries. The use of other
batteries may result in a reduced number of possible locking cycles.
2 The use of a screw with a different length may cause damage to
the lock.

Flexo.Code | 01-2023 Rev. 01 | English | 4
Mode: Fixed Assigned Authorization (Private Mode)
In this mode, a code is pre-set with which the lock can be
operated. This mode is suitable for user groups where user
rights do not have to change permanently, e.g. in an office
cabinet. To close, the user enters a stored code. The lock is
opened by entering this or another stored code. Up to 50 codes
can be stored. A code that has not been stored is rejected by the
lock.
Mode: Multi User Authorization (Multi User Mode)
This mode is suitable for constantly changing users who only use
the compartment temporarily or once, e.g. in a sports facility.
Codes are valid for a single locking process and are deleted by
the lock when the compartment is reopened so that a new code
can be used. The locking bolt remains open until a new code
locks the lock again. Before locking, the door must be closed
(slightly pressed). The user enters a code of choice (4 or 6 digits)
to close. The green LED starts flashing. The lock is opened by
entering the same code.
Code Confirmation (Multi User Mode)
To lock the lock, the code must be entered twice. The lock only
locks after the second entry. The second entry is made after the
green LED flashes briefly. A simple code entry is sufficient to
open the lock. This function can be turned on or off.
Master Code
The Master Code authorizes the programming of the lock. In
addition, the Master Code can unlock the lock independently
of the set mode (emergency opening) and terminate the block
mode. In Multi User Mode, the code used for locking is deleted
after the Master Code is entered.
Note: We recommend programming a private Master Code
before putting the lock into operation.
LED Locking Indication
The lock indicates the locked state by flashing the red LED every
second. This function can be turned on or off.
Automatic Locking (Private Mode)
The lock locks automatically after three seconds after unlocking.
The door does not have to be closed for this. The latch function
allows the door to be closed by pressing slightly even with the
lock locked. This function can be turned on or off.
Functional Description
Functional Description RTC
The Flexo.Code also has an integrated software real-time
clock (RTC) that can be used to program time-related functions.
The functions and the defined times must be specified when
ordering.
Automatic Locking / Unlocking at a certain time
The lock locks and unlocks automatically at a defined time. The
times can be set separately for each day of the week.
Programming is carried out by BURG.
Time Window Usage
The lock can only be operated within the individually defined
time-of-use period. The lock cannot be operated outside this
period. The times can be set separately for each day of the
week. Programming is carried out by BURG.
Closure Duration
The closure duration defines the maximum period for which a
lock may be locked from the time of locking. After expiry of the
locking period, the lock opens automatically. Programming is
carried out by BURG.
Battery Warning
If the battery capacity falls below a certain limit, the red LED
lights up for three seconds after the code has been entered. If
the critical level is reached, the lock can no longer be locked or
can only be opened with the Master Code.
Note: We recommend changing the battery already after the
first warning.
Block Mode
After three consecutive failed opening attempts, the lock locks
for 45 seconds. During this period, no action is possible on the
lock. The locking time is indicated by the red LED flashing every
second. The locking mode can be cancelled by entering the
Master Code.

Flexo.Code | 01-2023 Rev. 01 | English | 5
Place the fastening nut on the lock from behind. Tighten
the nut with a socket wrench (SW22).
Place the latch and fasten it with the Torx screw (Torx 30)
provided.
Then check whether the deadbolt gets sufficient hold on
the strike plate or the rebate when closed. The latch should
be able to be turned to its end position without pressure or
resistance when the locking system is closed.
Mounting dimensions
The dimensions for the installation hole on the outside of
the door applies to installation in fronts made of wood,
HPL and steel.
Assembly Flush Fit
Prepare the installation hole on the door front according to
the installation dimensions described below.
Note: If you require a template (step file) for milling,
punching or laser cutting, please contact your BURG
representative.
From the front, insert the Flexo.ring into the installation
hole on the outside of the door and hold it in this position.
Check whether the Flexo.ring is fully seated on the outside
of the door. Make sure that the mounting hole on the
inside is in the correct position. Screw the fastening nut to
the Flexo.ring from behind. Tighten the nut hand-tight.
Insert the lock body from the outside of the door into the
opening of the Flexo.Ring. Make sure that the BURG logo
on the front of the knob is at the top.
1
2
3
4
5
6
Note: The adjacent drawings
are not to scale and are not
suitable as a template for mil-
ling. For a template (step file),
please contact your contact
person at BURG.
45mm
¯47mm

Flexo.Code | 01-2023 Rev. 01 | English | 6
Place the cam and fasten it with the Torx screw (Torx 30)
provided.
Then check whether the deadbolt gets sufficient hold on
the strike plate or the rebate when closed. The latch should
be able to be turned to its end position without pressure or
resistance when the locking system is closed.
Note: Closing can be optimally adjusted by means of an
adaptable striking plate. For more information, please get
in touch with your contact at BURG.
Mounting dimensions
The dimensions for the installation hole on the outside of
the door applies to installation in fronts made of wood,
HPL and steel.
Assembly Retro Fit
Prepare the installation hole on the door front according to
the installation dimensions described below. Note that an
adapted two-stage recess may have to be milled for fronts
made of wood and MDF. This recess is not required for
metal fronts.
Note: If you require a template (step file) for milling,
punching or laser cutting, please contact your BURG
representative.
Insert the lock body into the installation hole from the
outside of the door. Make sure that the BURG logo on the
front of the knob is at the top.
Place the fastening nut on the lock from behind. Tighten
the nut with a socket wrench (SW22).
1
2
3
4
5
16mm
¯19mm
Note: The adjacent drawings
are not to scale and are not sui-
table as a template for milling.
For a template (step file), please
contact your contact person at
BURG.

Flexo.Code | 01-2023 Rev. 01 | English | 7
Configuration
Observe the following notes before you start the
configuration:
Each configuration step is started by pressing the hook key
twice and the corresponding digit.
Each configuration step is completed with the green LED
flashing twice.
The next configuration step can only be started after the
the green LED flashes twice.
If the red LED flashes 8 times in quick succession, the
configuration step was not carried out correctly.
1Mode Selection
a) Private Mode
Enter Master Code 1Master Code
Set mode 50
Note: To assign the private codes, please go to point
3a „Set the code“.
b) Multi User Mode (default)
Enter Master Code 1Master Code
Set mode 51
Note: After changing the mode, all functions are reset to the
default settings. This does not apply to the Master Code.
2Set Code Length
Enter Master Code 1Master Code
Select number of digits 0x
4 digits: x = 4
6 digits: x = 6
Note: After changing the number of digits, all codes stored in
Private Mode are deleted.
3Set Functions
a) Configuration in Private Mode
Set code
Enter Master Code 1Master Code
Set code 3xxxx (xx)
Note: Up to 50 private codes can be stored. Depending on the
set code length, these must be 4 or 6 digits long..
Delete the code
Enter Master Code 1Master Code
Delete code 9xxxx (xx)
Note: Enter the code you want to delete.
Automatic locking
Enter Master Code 1Master Code
Activate 61
Deactivate 60
b) Configuration in Multi User Mode
Code confirmation
Enter Master Code 1Master Code
Activate 21
Deactivate 20
c) Set General Functions
Set private Master Code
Enter current Master Code 1Master Code
Enter new Master Code 7xxx xxx
Note: The Master Code must be 6 digits long.
LED locking indication
Enter Master Code 1Master Code
Activate 81
Deactivate 80
Operation
1Operation in Private Mode
Lock enter code
Unlock enter code
2Operation in Multi User Mode
Lock enter code
Unlock enter code
Note: If the code confirmation is set, the code must be entered
twice when locking.

Flexo.Code | 01-2023 Rev. 01 | English | 8
Entry the Master Code
The Master Code can unlock the lock, authorizes the
configuration or terminate the block mode regardless of the set
mode. Observe the following note when entering the Master
Code:
Always start entering the Master Code by pressing the hook
key twice and the digit 1.
Enter Master Code 1Master Code
Note: In Multi User Mode, the code used for locking is deleted
after entering the Master Code.
Disposal and Battery Note
Image rights: cover, wood texture, Torsakarin / 123rf
EU Directive 2012/19/EU regulates the proper take-back,
treatment and recycling of used electronic equipment.
Every consumer is required by law to dispose of batteries,
accumulators or electrical and electronic equipment („waste
equipment“) powered by batteries or accumulators separately
from household waste, as they contain harmful substances
and valuable resources. Disposal can be done at a collection or
take-back point approved for this purpose, e.g. a local recycling
center. Waste equipment, batteries or rechargeable batteries are
accepted there free of charge and recycled in an environmentally
friendly and resource-saving manner.
Waste equipment, used batteries or rechargeable batteries can
also be returned to us. The return must be sufficiently stamped to
the address below.
The following symbol on the waste electrical equipment,
batteries or accumulators indicates that they must not be
disposed of with household waste:
Caution when using batteries!
The battery may explode or release flammable gases if it is
mishandled, destroyed, or the wrong type of battery is used. Do
not recharge the battery, disassemble it, expose it to extremely
high temperatures or throw it into a fire.
On batteries containing harmful substances, you will find
indications in the form of abbreviations for the ingredients
cadmium (Cd), mercury (Hg) and lead (Pb) in each case.
BURG F.W. Lüling KG
Volmarsteiner Str. 52
58089 Hagen (Germany)
+49(0)2335 6308-0
info@burg.de
www.burg.de
Battery Replacement
1. Push the opening pin into the closure hole at the bottom
of the lock. Move the pin slightly counterclockwise and
pull the knob forward.
2. Open the battery cover and replace the batteries.
Insert the new batteries according to the symbols ( + / - ).
Note: The surface of the batteries must be free of residues
and fingerprints, otherwise malfunctions may occur. If the
surface is dirty, it must be cleaned with a dry cloth.
3. Close the battery cover, push the knob back onto the lock
and turn the housing back until it locks into place.
Note: The lock is approved for VARTA brand batteries. The
use of other batteries may result in a reduced number of
possible locking cycles.
Table of contents
Other Burg Lock manuals

Burg
Burg B-Smart-Lock Combipad User manual

Burg
Burg TwinPad User manual

Burg
Burg Intro.Code User manual

Burg
Burg Combipad User manual

Burg
Burg Combipad User manual

Burg
Burg Intro.Code User manual

Burg
Burg Intro.Code User manual

Burg
Burg sPinLock 510 User manual

Burg
Burg B-Smart-Lock Corona User manual

Burg
Burg sPinLock 420 User manual

Burg
Burg Master Pro User manual

Burg
Burg Master User manual

Burg
Burg sPinLock 410 User manual

Burg
Burg m.options sPinLock 200 User manual

Burg
Burg B-Smart-Lock MASTER Instruction Manual

Burg
Burg Master Pro User manual

Burg
Burg Corona User manual

Burg
Burg H4C.20Z207 User manual

Burg
Burg sPinLock 200 User manual

Burg
Burg KeyPad Outdoor IP54 User manual