CDVI KCIEN User manual

SVENSKA
SE
ENGLISH
EN
The installer’s choice
cdvigroup.com
cdvi.se
KCIEN
KCIENSBP
KCIEN/IRC
Illuminated weatherproof keypad - Self Contained
Vattentätt rostfritt kompaktkodlås med bakgrundsbelysning

ARD12 BS60
Recommended
power supplies
IP67
-25°C to +70°C
Certication CE
WEEE & RoHS
HIGH RESISTANCE
TO VANDALISM
EN
KCIEN - KCIENSBP - KCIEN/IRC
Illuminated Weatherproof Keypad - Self Contained
INSTALLATIONSMANUAL
INSTALLATION MANUAL
2www.cdvi.se
www.cdvigroup.com
1] PRODUCT PRESENTATION
Backlit.
Stainless steel.
Compact design.
Compact.
2 relays.
Surface mount.
Free voltage.
Installation with Torx®screws.
100 user codes.
Audible and visual feedback.
Dimensions (L x W x D): 140 x 80 x 20mm.
Input voltage:
- 12 V to 24V ac,
- 12 V to 48V dc.
Consumption: 40 to 100mA.
2] REMINDERS AND RECOMMENDATIONS
Recommended power supplies
- There are two suitable power supplies
for the encoded keypad:
ARD12 and BS60
- Separate power supply for control components.
Mounting recommendations
Mount the keypad on a at surface to avoid
any vandalism and to insure the best mounting.
Security advice
For security advice reasons, change the factory
default master code. When selecting a master code
and user code avoid simple codes (example : 3 4 5 6 7).
Back EMF protection
To secure the system from back electromagnetic
elds do not forget to mount the varistor
in parallel on the lock.
KCIEN
KCIENSBP

1 2
43
EN
KCIEN - KCIENSBP - KCIEN/IRC
Illuminated Weatherproof Keypad - Self Contained
INSTALLATION MANUAL
3
www.cdvi.se
www.cdvigroup.com
3] MOUNTING KIT
Place the back plate of the
KCIEN-KCIENSBP on the
wall then mark with a pen
the hole location then drill
the 2 mounting holes (drill
bit Ø5mm and 35MM hole
depth) and the hole wiring
access.
Insert the 2 plastic
anchors in the holes.
Mount the back plate with
the M4x30 screws.
4] MOUNTING INSTRUCTIONS
Once you have made sure that the mounting kit is complete and that you prepared the cables
of the KCIEN/KCIENSBP keypad then you can proceed and mount the product. Make sure that
you have all the appropriate tools (drill, screw drivers and a meter tape...) and follow the
mounting instructions of for the KCIEN/KCIENSBP keypad.
Fasten the KCIEN-KCIENSBP
keypad to the back plate
with the M5x8 TORX®
screw and the T20 TORX®
spanner hardware.
Insert the cable in the
hole access area of the
back plate.Then mount
the keypad on the
back plate, placing rst
the top in the hook and
then the bottom.
Varistor
Torx®screw
(M5x8)
T20 Torx®
Spanner
(M4x30)
mounting
screws
Plastic anchors
S5
KCIEN
KCIENSBP 11122

EN
KCIEN - KCIENSBP - KCIEN/IRC
Illuminated Weatherproof Keypad - Self Contained
INSTALLATIONSMANUAL
INSTALLATION MANUAL
4www.cdvi.se
www.cdvigroup.com
5] PROGRAMMING CHART
A5
Master code
A0
Illumination
duration
A1
Time Relay 1
A2
Time Relay 2
A4
Code length
2 x beeps
1 x beep 1 x beep1 x beep 1 x beep 1 x beep
1 x beep = OK
4 beeps = error
1 x beep = OK
4 beeps = error
1 x beep = OK
4 beeps = error
1 x beep = OK
4 beeps = error
1 x beep = OK
4 beeps = error
Press B to exit
from programming
01 - 99 sec
00 = Toggle
01 = Default
01 - 99 sec
00 = Toggle
01 = Default
4, 5 or 6 digits
5 = Default
All digits are valid
1 2 3 4 5 =
Default
2 beeps
KCIEN-KCIENSBP
10 - 99 sec
00 = Permanent
10 = Default
Enter the master
code twice

EN
KCIEN - KCIENSBP - KCIEN/IRC
Illuminated Weatherproof Keypad - Self Contained
INSTALLATION MANUAL
5
www.cdvi.se
www.cdvigroup.com
5] PROGRAMMING CHART
A6
Reset
A7
Sub master
code 1
A8
Sub master
code 2
AA
Buzzer
(audible
feedback)
00-99
User codes
1 x beep 1 x beep1 x beep 1 x beep
Press A
Then B
2 Beeps
are emitted
1 x beep = OK
4 beeps = error
1 x beep = OK
4 beeps = error
1 x beep = OK
4 beeps = error 1 x beep = OK
2 digits
AB = Default
2 digits
13 = Default
0 = Buzzer
disabled
1 = Buzzer enabled
4, 5 ou 6 digit code
4 beeps = User
location: “Used”
1 beep = User
location: “Free”
KCIEN-KCIENSBP

Pink Grey
Magnetic lock
Strike
EN
KCIEN - KCIENSBP - KCIEN/IRC
Illuminated Weatherproof Keypad - Self Contained
INSTALLATIONSMANUAL
INSTALLATION MANUAL
6www.cdvi.se
www.cdvigroup.com
This product is supplied with a varistor.
It should be mounted on the terminal of electric release (electromagnetic lock, solenoid bolt, etc ...) controlled
by the device.If this device controls more than one electronic release, then each lock should be tted
with a varistor. The varistor controls the overload produced by the strike coil - back emf. It is recommended
to use a separate power supply when using a Shear Lock Magnet.
Outputs Description
Black
Input voltage 12V to 24V ac or 12V to 48V dc
Red
Input voltage 12V to 24V ac or 12V to 48V dc
Pink Relay 1 request to exit input
Purple Common
Dark green Clock switch (H1)
Green White Relay 2 N/C contact
Blue red Relay 2 common
Pink gray Relay 2 N/O contact
Orange Relay 1 N/C contact
Yellow Relay 1 common
Brown Relay 1 N/O contact
Light blue Request-to- enter input
Light green User code change
White Tamper switch output
Grey Tamper switch output
Power supply
12V to 24V ac
or 12V to 48V dc
White
Grey
Yellow
Orange
Brown
Green white
Electric strike
KCIEN
KCIENSBP
Back side
KCIEN
KCIENSBP
Front side Varistor
Blue red
Light green
Light blue
Pink
Purple
Dark green
Red
Black
Power control side
power supply
6] WIRING DIAGRAM
H2
H1
ST3
Resetting
memory

EN
KCIEN - KCIENSBP - KCIEN/IRC
Illuminated Weatherproof Keypad - Self Contained
INSTALLATION MANUAL
7
www.cdvi.se
www.cdvigroup.com
Description:
12V to 24V ac power supply
or 12V to 48V dc.
Illuminated 12 key keypad.
Non-volatil EPROM memory.
100 programmable codes
in 4, 5 or 6 digits.
2 form “C” contact N/O & N/C
6A/250V~.
Master code programmable
in 4, 5 or 6 digits.
Warning buzzer.
1 request - to - exit input.
Factory master code and code reset.
Code change by the user
Default values:
No codes.
Illumination time: 10 seconds.
Relay release time: 1 second.
Code length: 5-digits.
Master Code: 1 2 3 4 5.
Programming security-lag: 120s.
Code length for sub master code:
- Version 1 relay (Group 1) = Aand B,
- Version 2 relays (Group 2) = 1and 3.
One beep on switching on.
Audible signal correspondence:
- 1 short beep: Keypad powered
- 1 long beep: data computing
in programming or access granted.
- 2 beeps: Enter or Exit
from programming.
- 4 short beeps: data computing error.
Digits used and opening codes:
- The master code and the User codes
can be of 4 or 5-digit in length.
All the keypad keys can be used
to program a code. The master code
and the Pin code can be of 4, 5
or 6-digit code. The master code
can not be used as a PIN code
(User Pin code).
- Codes 0 0 0 0 0 0, 0 0 0 0 0
and 0 0 0 0 can only be used
to delete a user Pin code.
Control by push button:
- The connection of push button P1
is intended for controlling relay 1.
(the mode and the time-lag
can be programmed).
- Clock contact H1 enables use
of the outside button for free
opening. Clock contact H2 enables
use of all the keys as outside buttons.
If the clock contact is open, the keys
are used like normal digits.
If the clock contact is closed,
all the keys can be used for free access.
Consumption
(without the control elements)
With the 2 relays controlled
and permanent lighting:
- In 12V dc > 90mA max,
- In 12V ac > 70mA max,
- In 24V dc > 50mA max,
- In 24V ac > 40mA max.
A. Resetting the memory
1. Enter the master code twice.
- For the rst use, the factory
master code is: 1 2 3 4 5.
- Two beeps are emitted to conrm
entry in programming mode.
2. Then press A6.
- A short beep sounds is emitted.
- Press Aand B to conrm the resetting.
- Wait for a beep to be emitted
and for the lighting to go off.
- The master code is 1 2 3 4 5 again
and all the codes have been erased.
- The keypad is reinitialised.
- The keypad is no longer
in the programming mode and the default
values have been restored.
OR
1. Turn off the power supply.
Place a jumper at ST3
(See P. 6).
2. Turn the power supply on again.
Wait a few seconds, a beep is emitted.
3. The master code is 12345 again
and all the codes have been erased.
The default values have been restored.
B. Setting code length
1. Enter the master code twice.
- For the rst use, the factory
master code is: 1 2 3 4 5.
- Two beeps are emitted to conrm
entry in programming mode.
2. Press A4 to input the number of digits
in the codes.
- A short beep sounds is emitted.
- Enter 4, 5 or 6 for number of digits.
- A long beep sounds is emitted to conrm
the programming.
3. Press A5 to change the master code.
- A short beep sounds is emitted.
- Enter the 4, 5 or 6 digits of the new
master code.
- A long beep sounds is emitted to conrm
programming of the newmaster code.
4. Press B to exit from
the programming mode.
Two beeps sound are emitted to conrm
the return to the normal mode of operation.
4 beeps indicate a data computing error.

EN
KCIEN - KCIENSBP - KCIEN/IRC
Illuminated Weatherproof Keypad - Self Contained
INSTALLATIONSMANUAL
INSTALLATION MANUAL
8www.cdvi.se
www.cdvigroup.com
Example:
You have a 5-digit master code and 5-digit user
codes. You want to use 4-digit user codes.
When the number of digits in the master code
has effectively changed from 5 to 4, the user
codes become 4-digit codes at the same time.
E.g.: If your master code and user code is 1 2 3 6 9,
after the operation it will become 2 3 6 9.
If you want to switch from a master code (to one
of 5 digits follow the same procedure.
When changing from 4 to 5 digits, the gure “O”
will be added by default in front of the master
code and hence in front of the user codes.
Ex : The change from the master code 2 3 6 9
with 4 digits to one with 5 digits becomes 0 2 3 6 9.
We advise programming the codes
as 6 digits and then modifying
the code length.
C. CHANGING THE MASTER CODE
The master code is used only to enter
in programming mode.
1. Enter the master code twice.
- For the rst use the factory
master code is : 1 2 3 4 5.
- Two beeps sound are emitted to conrm
entry into the programming mode.
2. Press A5 to modify the master code.
- A short beep sounds is emitted.
- Enter the 4, 5 or 6 digits
of the new master code.
- A long beep sounds is emitted to conrm
that the master code is programmed.
3. Press B to exit from the programming mode.
Two beeps sound are emitted to conrm
the return to the normal mode of operation.
D.Adding, changing or deleting
a user code
Relay 1
Group 1 : From digit place 00 to digit place 59,
Relay 2
Group 2 : From digit place 60 to digit place 99.
1. Enter the master code twice.
- For the rst use the factory master code
is : 1 2 3 4 5.
- Two beeps sound are emitted to conrm
entry into the programming mode.
- Enter the master code twice:
Master code
Master code
2 beeps
2. Enter the user location
to be programmed (from 00 to 99).
- If the digit place is free, a short beep
sounds, enter the 4, 5 or 6 digits of the code.
- If the digit place is occupied, 4 beeps sound.
- Enter the 4, 5 or 6 digits of the code
or enter 0 0 0 0 0 0 or 0 0 0 0 0 or 0 0 0 0
to cancel the existing code.
- If the Pin code is already programmed
or is identical to the master code,
then 4 beeps are emitted.
- Codes 0 0 0 0 0 0 or 0 0 0 0 0
or 0 0 0 0 serve to cancel an existing
code and hence cannot be used
as an usual code.
3. Press B to exit from the programming mode.
- Two beeps sound are emitted to conrm
the return to the normal mode of operation.
E. Time outputs
1. Enter the master code twice.
- For the rst use, the factory
master code is: 1 2 3 4 5.
- Two beeps sound are emitted to conrm
entry into the programming mode.
2. Enter A0 for the key-in keypad time.
- One short beep sound is emitted.
- Enter the duration time in seconds.
E.g. : From 10 for 10 seconds to 99
for 99 seconds or enter 00 for a permanent
illumination. A long beep sounds to conrm
the programming.
3. Press A1 for output time of relay 1
-A short beep sounds is emitted.
- Enter the duration in seconds.
E.g.: 01 for 1 second up to 99 for 99 sec.
Enter 00 for a toggled output. One beep
is emitted to validate the time.
4. Press A2 for the output time of relay 2.
- A short beep sounds is emitted.
- Enter the time in seconds.

EN
KCIEN - KCIENSBP - KCIEN/IRC
Illuminated Weatherproof Keypad - Self Contained
INSTALLATION MANUAL
9
www.cdvi.se
www.cdvigroup.com
E.g.: 01 for 1 second up to 99 for 99 seconds.
Enter 00 for a toggled output. One beep
is emitted to validate the time.
5. To exit from the programming mode,
press B.
Two beeps sound to conrm the return
to the normal mode of operation.
4 beeps signal an input error.
F. Resetting the master code
- In normal operation, place a jumper at ST3.
- Wait for a beep to sound.
- Remove the jumper.
- The master code is again 1 2 3 4 5 6
in 6 digits, 1 2 3 4 5 in 5 digits or 1 2 3 4
in 4 digits.
G. Changing the code by the user
To authorize a user to modify its own User
code connect together the light green
and the purple wires
1. Enter the old user code.
The relay is activated and a beep
is emitted.
2. Enter the 2-digit sub master code
(default sub master code A and B).
A beep is emitted to authorise
the modication.
3. Enter the new user code.
2 beeps are emitted to conrm
the new code.
4. Check the new user code to be sure
ofthemodication.
H.Setting a sub master code
1. Enter the master code twice.
- For the rst use the factory
master code is : 1 2 3 4 5.
- Two beeps sound are emitted to conrm
entry into the programming mode.
2.PressA7toinputmodicationdigits
for group 1 user codes.
- A short beep sounds is emitted.
- Enter the two digits of the modications.
- A long beep sounds are emitted
to conrm the programming.
3.PressA8toinputmodicationdigits
for group 2 user codes.
- A short beep sounds is emitted.
- Enter the two digits of the modications.
- A long beep sounds to conrm
programming.
4. Press B to exit from the programming mode.
Two beeps sound are emitted to conrm
the return to the normal mode of operation.
I. Programming the audible signal
- The audible signal is always audible
during programming.
- It is also audible on a command to open,
following the recognition of a code.
- By default, when the opening code
is entered, no “key” beep is audible.
- It is possible to authorise key beeps
by proceeding as follows:
1. Enter the master code twice.
- For the rst use the factory
master code is : 1 2 3 4 5.
- Two beeps sound are emitted to conrm
entry into the programming mode.
2. Press AA.
- One beep is emitted.
- Press 0to disable the audible signal
during a keypress.
- Press 1to enable the audible signal
during a keypress.
- A beep is emitted to conrm the new
setting.
3. Press B to exit from the programming mode.
Two beeps sound are emitted to conrm
the return to the normal operating mode.

EN
KCIEN - KCIENSBP - KCIEN/IRC
Illuminated Weatherproof Keypad - Self Contained
INSTALLATIONSMANUAL
INSTALLATION MANUAL
10 www.cdvi.se
www.cdvigroup.com
User code table.
User
location Code Name
Forename
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
User
location Code Name
Forename
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
User
location Code Name
Forename
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
KCIEN-KCIENSBP 1 Relay
Group 1: User location 00 to 59. KCIEN-KCIENSBP 2 Relays
Group 2 : User location 60 to 99.
REMINDER
Other manuals for KCIEN
2
This manual suits for next models
2
Table of contents
Languages:
Other CDVI Intercom System manuals

CDVI
CDVI CDV-91 User manual

CDVI
CDVI CDV4791 User manual

CDVI
CDVI 2Easy CDV4796KP-DX User manual

CDVI
CDVI CDV-4791S-DXB User manual

CDVI
CDVI CDV-DDP-F User manual

CDVI
CDVI CDV4791S-DX User manual

CDVI
CDVI CD97-4ID User manual

CDVI
CDVI 2EASY CDV-96KP User manual

CDVI
CDVI 2EASY CDV-850IP User manual

CDVI
CDVI CDV96KP User manual