5.2 Electric Lock Connection
5.2.1 Door Lock Controlled with Internal Power
Note:
1. Electronic lock of Power-on-to-unlock
type should be used.
2. The door lock is limited to 12V, and
holding current must be less than 250mA.
3. The door lock control is not timed from
Exit Button(EB).
4. The Unlock Mode Parameter of Monitor
must be set to 0 (by default).
EB
*
LOCK
PL S+S-
1 2 3
BUS
1 2 3
5.2.2 Door Lock Controlled with Dry Contact
Note:
3. Setup the Unlock Mode of Monitor
for different lock types.
LOCK
Take off the Jumper
POWER
SUPPLY
BUS PL S+S-
1. The external power supply must be
used accordance to the lock current.
2. The jumper must be removed
before connecting.
•Power-on-to-unlock(fail secure):Unlock Mode=0 (by default)
•Power-off-to-unlock(fail safe):Unlock Mode=1
5. When it connected to a fail secure electronic
lock,set the jumper position to 2-3.
6. When it connected to a fail safe lock,
set the jumper position to 1-2.
For connection to a fail secure lock, the jumper
position is 2-3.
For connection to a fail safe lock, jumper
position is1-2.