CDVI CDV4791 User manual


2
2Easy 1 User Video Entry Kit
CDV4791/2

Camera Lens
BUS
PL
S1+ S2+ S-
1 2
ON
Rain Cover
2Easy 1 User Video Entry Kit
CDV4791/2
2.1: Terminal Descriptions
2: CDV91/92 Parts and Functions
3
Main Connection Port

160-165cm
1
2
1 2 3 4
2.2: Installation & Adjustments
Mounting Without Rain Cover
2Easy 1 User Video Entry Kit
CDV4791/2
160-165cm
1
2
1 2 3 4
Mounting With Rain Cover
4

name label
1 2
ON
2Easy 1 User Video Entry Kit
CDV4791/2
5
From the rear of the metal section of the CDV91/92 unclip the plastic cover to open the transparent
name plate, insert a name label and replace the plastic cover.
The PC6A is a power/bus combiner unit, which is designed for the CDV 2Easy 2 wire
system to supply power for the external station, internal monitor and other accessories on
the bus. It can operate as a normal power/bus combiner or auxiliary PSU. The features are
as follows:
• Universal AC input/full range
• Multi protection: short circuit, overload, over voltage
• Integrated with DT-DPS(power separator), Additional
DT-DPS is not needed.
• Support up to 4~8 monitors(depend on models)
• DIN Rail Mounting
3.1:Description:
3: CDV-PC6A Parts and Functions
Fitting The Name Label

2Easy 1 User Video Entry Kit
CDV4791/2
LED
CN
1 2 3
BUS(IM) BUS(DS)
N LPG L
100~240 Vac
PG NLL
PG: Earth ground terminal.
N: AC input terminal.
L: AC input terminal.
LED: Power indicator, on when power connected.
CN: Bus control terminal.
BUS(IM): Indoor monitor connection terminal.
BUS(DS): Door station connection terminal.
6
Open the AC cover:
1. Push the cover base towards
the centre with your fingers;
2. Lift up and pull out the cover.
After connecting the AC cable, it is
advised to replace the cover.
Note:
1. The AC cable is not included in the
package, it must comply to the specific
requirements of country where installed.
CN
1 2 3
BUS(IM)
Connect to monitor Connect to door staiton
BUS(DS)
AC Input
100~240Vac
N L
PG L
*
2. Pins 1&2 should be short-circuited
with a C3-3P link(included in the package)
if the unit operates as a standard power
combiner. If operating as an auxiliary
power combiner, the link should be
removed.
2:Terminal Descriptions:

4: CDV47 Parts and Functions
145~160 cm
Terminal description
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches
SW+
SW-
RING
GND
NC
1 2 3 4 5 6
ON DIP
L1,L2: Bus line terminal (green Connector).
NC: Reserved
SW+,SW-: Doorbell call button connection
port.
DIP switches: Total 6 bits can be
•Bit 1~Bit5: User Code (Address) setting.
•Bit6 : Set to ON if the monitor is at the
end of the line or operates with DBC4A.
Otherwise, set to OFF.
Ring,GND: Extra buzzer connection port.
2Easy 1 User Video Entry Kit
CDV4791/2
7

CLOSE
SETTINGS
PHONE
TCETEDNOITOMTHGIL
SMS
MEDIA
CALL RECORD
CALL SCENARIO
INTERCOM
Current date and time
Status bar
LOGO
Main Menu
00:10 DS-1
REC
The Main menu is the starting point for using all the applications on the monitor. The Main
menu can be customised to display a chosen logo.
Touch anywhere of the screen on monitor in standby mode, the Main menu will appear as fol-
lows:
MONITOR
Touch to view doorstation camera
Touch t o ent er
intercom options.
Touch to view Device
information.The logo
can be customized.
Touch to enter
set up page.
Touch to set up the divert
number or activate the divert
function.
Touch to activate the
light function via RLC.
Touch to enter motion
detection options.
Touch to turn off the screen
and set the monitor in standby
mode.
Touch to activate Mute,Left
message and Divert call
functions.
Touch to view calling in/calling
out records or missed calls .
Touch to write messages or
review the received/sent
messages.
Touch to play recorded images
or video from door stations.
In communication with a door station
Displays door station ID
during call.
Shows status of talk, unlock etc.
Displays talk time.
Flashes while recording.
Review messages left by visitor.
View information from memory/SD
card.
5 direction pad button,
To enable pan, tilt &
zoom of the picture.
Note: The 5 direction pad operates only with CDV97 door station.
2Easy 1 User Video Entry Kit
CDV4791/2
8

eInput No. User Code Input No. User Code Input No. User Cod
2Easy 1 User Video Entry Kit
CDV4791/2
User code (address) for the monitor:
4. Touch “ “ key to exit.
Cursor
Keypad type
abc- Alphabet keypad
123-Number keypad
Edit box
Delete the last character
Save setting
Exit current page
INSTALLER SETUP 123
_
00-31
Space key
Insert a space.
Move the cursor.
1.In the address setting page, select Manual Input Address setting mode, then touch icon,
a keypad will be displayed.
2.Enter the code by touching the digital number.
3.Touch “OK” key to save, code setting complete.
Switch the keypad
between alphabet
and numerical.
Manual Input Address
The address can also be entered manually .
•A total of 32 numbers can be set, from 00~31.
•When multiple monitors are installed in one apartment, the monitors should be set to
thsame user code and the master/slave mode should be set on the monitor. (Details refer
to the section of Setting Slave Monitor)
9

Touch the screen anywhere on monitor
in standby mode, the main menu page
will be shown as follows:
Setting the Slave address:
2Easy 1 User Video Entry Kit
CDV4791/2
INSTALLER SETUP 123
_
? + OK: Help Menu
@ + OK: Address Setting Menu
Master/Slave can also be set directly as follows:
Touch the keys“@ and ok” to open Address Setting menu. Refer to the following:
•Select Master/Slave setting option,
touch / icon to scroll to next
option,settings will saved
immediately.
Entering installer setup
00:10 DS-1
About
Local Address 00.00
Video Standard AUTO
System Verson 00.01.00
Display Driver 1.0
Font 1.0
UI 1.0
INSTALLER SETUP 123
_
? + OK: Help Menu
@ + OK: Address Setting Menu
•On main menu page, touch [Logo] icon to enter the About page.
•When the screen shows the About page, press UNLOCK button on front panel and
hold for 2 seconds.
Refer to the following:
•A keypad is shown.
A maximum of 4 monitors can be connected in one apartment (call button),one
master monitor together with 3 slave monitors, the address must be set
correctly.(Note: one monitor to be set as master monitor - address 00)
The code of 8000 is used to set the master monitor.
The code of 8001 is used to set the first slave monitor .
The code of 8002 is used to set the second slave monitor .
The code of 8003 is used to set the third slave monitor .
10

Unlock time:
Setting the slave monitor video on:
How to set the unlock parameter:
Unlock mode:
2Easy 1 User Video Entry Kit
CDV4791/2
Code 8010 is used to set the unlock mode to 0
Code 8011 is used to set the unlock mode to 1
The unlock time can be changed at any time, it can be set from 1 to 99 seconds.The codes
from 8401 to 8499 are used to set the unlock time to 1~ 99 seconds.
ceiv a (subject to cable type).
• Click the item again to cancel.
• Click “ Slave Panel On When Being Called” item,when “ “ symbol is displayed in the
frame , the setting is activated.
The above setting can also be set directly from the menus in the same field as Master/Slave.
Setting monitor time
* 30s is the default monitor time.
In default mode, when receive a calling the master and slave monitors will ring at the
same time, however the master monitor will display the image while the slave monitors
will not. This setting can be changed to allow all the slave monitors to display video from
the panel at the same time when receiving a call, enter the code number of 8006 on each
slave monitor. (Note: it is not recommended to have more than 2 monitors setto on when
using cat5/6 cable).
Monitor Time the time out period when a door station has been selected to be viewed
from a monitor, it can be changed at any time. The time can be to set to 30s, 40s, 50s,
1min, 2min, 3min,4min, 5min, 6min, 7min, 8min, 9min or 10min.
1.On main menu page, touch settings icon ->[More...].
2.Select Monitor Time Set item.
3.Touch / icon to adjust the levels. Settings will perform immediately.
There are two unlock modes: 1.power-on- to-unlock(fail secure):unlock mode =0 (default)
2.power-off-to-unlock(fail safe):unlock mode = 1.
11

The maximum cable distance of the wiring is limited. Using different cables will also affect
the maximum distance available from the 2Easy system.
5: Schematics & Wiring
2Easy 1 User Video Entry Kit
CDV4791/2
12
When Monitor quantity < 20
Cable Usage A B C
Twisted cable 2x0.75 mm260 60 30
Twisted cable 2x1 mm280 80 40
When Monitor quantity > 20
Cable Usage A B C
Twisted cable 2x1 mm270 30 20
Twisted cable 2x1.5 mm270 50 30
B
A
C
DBC4A
monitor
monitor
monitor
with two or four monitors
100~240VAC
BUS(IM) BUS(DS)
PC6
AC~
The farthest monitor

12
5.2Basic Wiring Configurations
ON
monitor monitor monitor monitor
1 2
ON
ID=00
2Easy 1 User Video Entry Kit
CDV4791/2
BUS(IM) BUS(DS)
PC6
AC~
-
+
12
L1 L2 PL S1+ S2+ S-
'Daisy'Chain Connection:
13
1 2 3 4 5 6
ON DIP
L2
L1
DIP Switches

monitor
monitor
monitor
monitor
ID=00
1 2
ON
A B C D
DIP=on,off,off
Star Connection with CDV-DBC4A:
Multiple Door Station Connection
2Easy 1 User Video Entry Kit
CDV4791/2
DBC4A
12
L1 L2 PL S1+ S2+ S-
12
ON
L1 L2 PL S1+ S2+ S-
12
L1 L2 PL S1+ S2+ S-
L1 L2 PL S1+ S2+ S-
A B C D
OFF
ON
Impedance
switch
BUS(IM) BUS(DS)
PC6
AC~
14
Impedance
OFF ON
switch

EB
*
LOCK
BUS PL S1+ S2+ S-
LOCK
2nd
1ST
2nd
EB
*1ST
EB
*
LOCK
BUS PL S1
+
S2
+S-
Note:
Connecting one lock: Connecting two locks:
Jumper position in 1 & 2
Jumper position in 1 & 2
1. Electric locks must be Power-on-to-unlock.
2. The door lock output is limited to 12V with holding current maximum of 250mA.
3. The door lock output is not timed from the Exit Button(EB).
4. The unlock parameter of the monitor must be set to 0 (default).
5.3Electric Lock Connection
2Easy 1 User Video Entry Kit
CDV4791/2
15

LOCK
BUS PL S1
+
S2
+S-
Take off the Jumper
POWER
SUPPLY
LOCK
BUS PL S1
+
S2
+S-
Take off the Jumper
POWER
SUPPLY
LOCK
Note:
1. The external power supply must be rated according to the lock consumption.
2. The jumper must be removed before connecting.
3. Set up the unlock mode for the monitor for lock type:
Connecting one lock Connecting two locks
8010 - Power-on-to-unlock type:Unlock Mode=0 (default)
8011 - Power-off-to-unlock type:Unlock Mode=1
2Easy 1 User Video Entry Kit
CDV4791/2
Temperature: -100C~+450C
Wiring: 2 wires - Unscreened twistedpair(non-polarity)
Dimension: 176(H)×90(W)×24(D)mm
16
Power Supply : DC 24V (supplied by PS1-24V or PS5-24V)Power
Consumption: Standby 50mA;
Operating Current: 200mA
Camera: 105 Degree Pinhole Sharp Color CCD; 420 TV Lines
Unlocking time: 1-9S, set by monitor. Default is 5 seconds
Power supply: 12Vdc, 300mA(Internal Power)

2Easy 1 User Video Entry Kit
CDV4791/2
Input Voltage:100~240Vac
detaRzH06~05:ycneuqerFtupnI
V2+V82CD:egatloVtuptuO
A5.1:tnerruCtuptuOdetaR
Working Temperature: -100C~500CSW
A2,cav032xaM:egatloVtupnI
mm06x09x041:noisnemiD
1) All components should be protected from shock or vibration, and be careful the
products are not impacted, knocked or dropped.
2) Please clean with a soft cotton cloth, please do not use a chemical cleaning agent. If
necessary, please use a little pure water or dilute soapy water to clean.
3) Image distortion may occur if the video monitor is mounted too close to a magnetic
feld eg microwaves, TV's, computers etc.
4) Please do not subject the monitor to wet, high temperature, dust, caustic and oxidation
gas environments, any of which could cause unpredictable damage.
5) Please use the right adaptor which is supplied by the manufacturer, or approved
by the manufacturer.
6) Pay attention to the high voltageinside the products, please refer service only to a
trained and qualifed professional.
17

2Easy 1 User Video Entry Kit
CDV4791/2
1) All components should be protected from shock or vibration, prevent impacts and
sharp knocks. Do not drop
2) Please clean with a soft cotton cloth, please do not use a chemical cleaning agent. If
necessary, please use a little pure water or dilute soapy water to clean.
3) Image distortion may occur if the video monitor is mounted too close to a magnetic
feld eg microwaves, TV's, computers etc.
4) Please do not subject the monitor to wet, high temperature, dust, caustic and oxidation
gas environments, any of which could cause unpredictable damage.
5) Please use the right adaptor which is supplied by the manufacturer, or approved
by the manufacturer.
6) Pay attention to the high voltageinside the products, please refer service only to a
trained and qualifed professional.
18
This manual suits for next models
1
Table of contents
Other CDVI Intercom System manuals

CDVI
CDVI KCIEN User manual

CDVI
CDVI CDV-91IP User manual

CDVI
CDVI CD97-4ID User manual

CDVI
CDVI CDV96KP User manual

CDVI
CDVI CDV-91 User manual

CDVI
CDVI CDV-91 User manual

CDVI
CDVI 2EASY CDV-47DX User manual

CDVI
CDVI 2Easy CDV4796KP-DX User manual

CDVI
CDVI CDV4791S-DX User manual

CDVI
CDVI CDV-471IP User manual

CDVI
CDVI 2EASY CDV-T5 User manual

CDVI
CDVI CDV-17HFA User manual

CDVI
CDVI CDV97-1ID User manual

CDVI
CDVI CDV96KP User manual

CDVI
CDVI CDV97-8ID Series User manual

CDVI
CDVI CDV-DDP User manual

CDVI
CDVI CDV-DDP-F User manual

CDVI
CDVI CDV91F User manual

CDVI
CDVI DMR18S User manual

CDVI
CDVI 2EASY CDV-91S User manual