CDVI CDV97-8ID Series User manual

USER MANUAL
CDV-ENG-97-8ID-V1 / 201708
RF CARD
CDV97-8ID
CDV97-8ID Series
2 WIRE SYSTEM
8 Button Door Station
With Proximity Access Control & Fish Eye Camera
• Please read this manual thoroughly to ensure safe and correct operation.
• Please keep this manual safe for future use.

CONTENTS
PARTS AND FUNCTIONS ..................................................................................... 3
Part Names............................................................................................................. 3
Mounting................................................................................................................. 3
Terminal Description............................................................................................... 4
BASIC FUNCTIONS .............................................................................................. 5
Unlock Operations.................................................................................................. 5
Fisheye Camera ..................................................................................................... 5
SETUP INSTRUCTIONS........................................................................................ 6
Functions Setting Up .............................................................................................. 6
Setting Door Station Address ................................................................................. 7
Setting Camera N/P Standard................................................................................ 8
Setting Prompt Voice.............................................................................................. 8
Setting Prompt Voice Volume................................................................................. 9
Setting Unlock Mode .............................................................................................. 9
Setting Unlock Time............................................................................................... 10
Setting Nameplate Illumination Mode.................................................................... 10
Setting Night View LED Illumination Mode............................................................ 11
Setting Ring-back Tone ......................................................................................... 11
Setting Image Display Mode.................................................................................. 12
Registering ID Card............................................................................................... 13
Restore To Default................................................................................................. 15
WIRING ................................................................................................................. 16
Connecting Electric Lock....................................................................................... 16
APPENDIX ............................................................................................................ 17
Precautions............................................................................................................ 17
Specication .......................................................................................................... 17
Cables and Requirments....................................................................................... 18

-3-
Part Names
PARTS AND FUNCTIONS
[9]
[10]
[11]
[12]
[8]
[7]
[6]
[5]
[1]
[3]
[4]
[2]
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Speaker
Mounting
1 2 3 4 5
Rainy cover
The distance between
the top of main unit
and rain cover should
be not less than 3mm.
Main unit
≥3mm
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
Rainy cover
Main unit
The installation height is suggested to 145~160cm.
[7] Night view LED
[8] Camera lens
[9] Rain cover
[10] Mounting holes
[11] Connection port
[12] External key module
1. Drill holes in the wall to match the size of wall plugs, then attach the rain cover to the wall.
2. Connect the cable as per instructions and attach the main unit to the rain cover. The distance
between the top of main unit and rain cover should not be less than 3mm.

-4-
PARTS AND FUNCTIONS
Lock Control Jumper: To select the lock type.
3P Connect Port: To button module.
Main Connect Port: To connect the bus line and the electronic locks.
• L1,L2: Connect to the bus line, no polarity.
• PL: External lock power input, connect to the power positive(power +).
• S+: Lock power(+) output.
• S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door
station to power the locks, if using the external power supply for the locks, the S- will not be
connected).
1 2 3
Lock Control Jumper
3P Connect Port
+12V
GND
PIR
L1 L2
PL
S+ S-
Main Connect Port
Terminal Description
3. Install the name plate.
4. Attach the front panel to the rain cover.
5. Use the special screwdriver and the screws to x the panel.

-5-
BASIC FUNCTIONS
Unlock Operations
Unlocking of ID Card
When the registered user card has been shown to ID card window, the UNLOCK indicator lights
up, the buzzer sounds,and the electric door strike is unlocked.
• If show the authorized user card,the buzzer will sound of beep+,and the UNLOCK indicator
will light up.
• If show the unauthorized user card,the buzzer will sound of beep,beep,beep.
Fisheye Camera
Please note that this function requires the
monitorwithsheyefunctiontosupport.
The angle view is 1700,visitors in this angle
view can be seen clearly and can be zoomed
to see individuals up close via indoor monitor
withsheyefunction.
Standard
door station angle
DT608
1700door camera angle
(Wide angle view shown)

-6-
SETUP INSTRUCTIONS
Functions Setting Up
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_CALL
LED_NAME
Main unit
RF CARD
This section explains the settings of each
function, please refer to the following table:
To perform the settings for the function
you want,you should move away the metal
front panel. Please refer to the sketch
map.
Each operation is indicated by the lighting
up of the LED indicator on the unit, and by
the sounding of the buzzer.
Order Setting items Setting range Default value
4 Setting prompt voice volume 1~9 6
7Setting the nameplate
illumination mode On/Off/Auto On
8Setting night view LED
illumination mode On/Off/Auto Auto
Ringing one time
10 Setting image display mode
Alternate switching mode
Zoom mode
Full screen mode
Alternate switching mode
6 Setting the unlock time 01 to 99 seconds 5 seconds
6 Setting the unlock mode 0:opened
2 Setting camera N/P standard NTCS or PAL standard PAL standard
1 Setting door station address 0~3(DS 1 to 4) 0
3 Setting prompt voice Max. 2 Settings - Off or On Voice prompt On
Ring once
10 Setting ring-back tone Ring continuously
No ring-back tone
0 - Normally Open
1 - Normally Closed

-7-
Setting Door Station Address
UNLOCK Indicator:OFF
TALK Indicator:OFF Buzzer Beep+, Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep+
In standby mode, press
KEY_SET button once
Press KEY_1 button to set
the first door station.
Press KEY_2 button to set
the second door station.
Press KEY_3 button to set
the third door station.
Press KEY_4 button to set
the fourth door station.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep,Beep
SETUP INSTRUCTIONS
ID=0,1st door station ID=1,2nd door station ID=2,3rd door station ID=3,4th door station
A total of 4 addresses can be congured. The address can be modied either before or
after installation. 0(DS #1) is default, to change the address, please use the following
steps:
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the address of door station can be changed by pressing KEY1~4 cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.

-8-
Setting Prompt Voice
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Play the voice 1
Press KEY_3 button to set the
prompt voice to Voice 1.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Play the voice 2
Press KEY_3 button again
to set the prompt voice to
Voice 2.
Press KEY_3
SETUP INSTRUCTIONS
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+
Press KEY_2 button to set the
camera standard to P
standard.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep, Beep
Press KEY_2 button again
to set the camera standard
to N standard.
Press KEY_2
P(PAL) standard is default, to change the setting, please follow the steps:
The video standard of the camera can be changed at any time, that means the quality of
image on screen can be set to differ.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the calling mode can be changedby pressing KEY2cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.
There are 2 options Voice prompt on or off. On is default;to change
the setting please use the following steps:
Beep+
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer
Press KEY_3 button again
and again to set the prompt
voice to No voice.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the calling mode can be changedby pressing KEY3cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.
Setting The Camera NTSC/PAL Video Standard

-9-
SETUP INSTRUCTIONS
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Play the volume
Press KEY_4 button to set the
volume level.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer
Press KEY_4
Play the volume level 9
Press KEY_4 button again
and again to set the volume
level you want.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+
Press KEY_1 button to set
the unlock mode to
Normally opened.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep
Press KEY_1 button again
to set the unlock mode to
Normally closed.
Press KEY_1
Setting Prompt Voice Volume
A total of 9 volume levels can be congured. The levels can be modied either
before or after installation. 6 is default;to change the setting please use the
following steps:
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the volume level can be changedmode by pressing KEY4cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.
Setting The Unlock Mode
There are 2 unlock modes, Normally open and Normally closed. Normally opened
is default, to change the setting, please use the following steps:
• While in the setting mode, the calling mode can be changedby pressing KEY1 cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.
•
e setting mode manually press the KEY_
If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit th SET button four times.

-10-
Setting Nameplate Illumination Mode
Setting Unlock Time
SETUP INSTRUCTIONS
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep,Beep......
Press and hold on KEY_2
button. The time you holding
on is the new unlock time.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+
Press KEY_3 button to set
the nameplate illumination
mode to Normally on.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep
Press KEY_3 button again
to set the nameplate illumina-
tion mode to Normally off.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep,Beep
Press KEY_3 button again
and again to set the nameplate
illumination mode to Auto.
Press KEY_3
By default the unlock time is 1s,this can be changed from 1s~99s. To change the unlock
time please use the following steps:
• When holding button 2 to set the unlock time, the buzzer will sound one time every second
• The LED_NAME indicator will flash continually while in the setting mode.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• Press KEY_SET button twice to exit out the setting mode manually.
There are 3 illumination modes for the nameplate indicator, Normally on,Normally off and
Auto. Normally on is default, to change the setting, please follow the steps:
• If setting mode has not been exited, you can change the nameplate illumination mode by pressing KEY3
cyclically.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• The LED_NAME indicator will continually flash while in the setting mode.
Table of contents
Other CDVI Intercom System manuals

CDVI
CDVI 2EASY CDV-47DX User manual

CDVI
CDVI 2Easy CDV4796KP-DX User manual

CDVI
CDVI CDV-DDP User manual

CDVI
CDVI CDV-471IP User manual

CDVI
CDVI CDV4791 User manual

CDVI
CDVI CD97-4ID User manual

CDVI
CDVI CDV-17HFA User manual

CDVI
CDVI CDV-DDP-F User manual

CDVI
CDVI 2EASY CDV-91S User manual

CDVI
CDVI CDV96KP User manual

CDVI
CDVI CDV4791S-DX User manual

CDVI
CDVI CDV-4791S-DXB User manual

CDVI
CDVI CDV4796KP-DX User manual

CDVI
CDVI CDV-91 User manual

CDVI
CDVI 2EASY CDV-850IP User manual

CDVI
CDVI CDV91S User manual

CDVI
CDVI CDV96KP User manual

CDVI
CDVI CDV91F User manual

CDVI
CDVI 2EASY CDV-T5 User manual

CDVI
CDVI KCIEN User manual