USER MANUAL
CDV-ENG-97-8ID-V1 / 201708
RF CARD
CDV97-8ID
CDV97-8ID Series
2 WIRE SYSTEM
8 Button Door Station
With Proximity Access Control & Fish Eye Camera
• Please read this manual thoroughly to ensure safe and correct operation.
• Please keep this manual safe for future use.

CONTENTS
PARTS AND FUNCTIONS ..................................................................................... 3
Part Names............................................................................................................. 3
Mounting................................................................................................................. 3
Terminal Description............................................................................................... 4
BASIC FUNCTIONS .............................................................................................. 5
Unlock Operations.................................................................................................. 5
Fisheye Camera ..................................................................................................... 5
SETUP INSTRUCTIONS........................................................................................ 6
Functions Setting Up .............................................................................................. 6
Setting Door Station Address ................................................................................. 7
Setting Camera N/P Standard................................................................................ 8
Setting Prompt Voice.............................................................................................. 8
Setting Prompt Voice Volume................................................................................. 9
Setting Unlock Mode .............................................................................................. 9
Setting Unlock Time............................................................................................... 10
Setting Nameplate Illumination Mode.................................................................... 10
Setting Night View LED Illumination Mode............................................................ 11
Setting Ring-back Tone ......................................................................................... 11
Setting Image Display Mode.................................................................................. 12
Registering ID Card............................................................................................... 13
Restore To Default................................................................................................. 15
WIRING ................................................................................................................. 16
Connecting Electric Lock....................................................................................... 16
APPENDIX ............................................................................................................ 17
Precautions............................................................................................................ 17
Specication .......................................................................................................... 17
Cables and Requirments....................................................................................... 18

-3-
Part Names
PARTS AND FUNCTIONS
[9]
[10]
[11]
[12]
[8]
[7]
[6]
[5]
[1]
[3]
[4]
[2]
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Speaker
Mounting
1 2 3 4 5
Rainy cover
The distance between
the top of main unit
and rain cover should
be not less than 3mm.
Main unit
≥3mm
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
Rainy cover
Main unit
The installation height is suggested to 145~160cm.
[7] Night view LED
[8] Camera lens
[9] Rain cover
[10] Mounting holes
[11] Connection port
[12] External key module
1. Drill holes in the wall to match the size of wall plugs, then attach the rain cover to the wall.
2. Connect the cable as per instructions and attach the main unit to the rain cover. The distance
between the top of main unit and rain cover should not be less than 3mm.

-4-
PARTS AND FUNCTIONS
Lock Control Jumper: To select the lock type.
3P Connect Port: To button module.
Main Connect Port: To connect the bus line and the electronic locks.
• L1,L2: Connect to the bus line, no polarity.
• PL: External lock power input, connect to the power positive(power +).
• S+: Lock power(+) output.
• S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door
station to power the locks, if using the external power supply for the locks, the S- will not be
connected).
1 2 3
Lock Control Jumper
3P Connect Port
+12V
GND
PIR
L1 L2
PL
S+ S-
Main Connect Port
Terminal Description
3. Install the name plate.
4. Attach the front panel to the rain cover.
5. Use the special screwdriver and the screws to x the panel.

-5-
BASIC FUNCTIONS
Unlock Operations
Unlocking of ID Card
When the registered user card has been shown to ID card window, the UNLOCK indicator lights
up, the buzzer sounds,and the electric door strike is unlocked.
• If show the authorized user card,the buzzer will sound of beep+,and the UNLOCK indicator
will light up.
• If show the unauthorized user card,the buzzer will sound of beep,beep,beep.
Fisheye Camera
Please note that this function requires the
monitorwithsheyefunctiontosupport.
The angle view is 1700,visitors in this angle
view can be seen clearly and can be zoomed
to see individuals up close via indoor monitor
withsheyefunction.
Standard
door station angle
DT608
1700door camera angle
(Wide angle view shown)

-6-
SETUP INSTRUCTIONS
Functions Setting Up
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_CALL
LED_NAME
Main unit
RF CARD
This section explains the settings of each
function, please refer to the following table:
To perform the settings for the function
you want,you should move away the metal
front panel. Please refer to the sketch
map.
Each operation is indicated by the lighting
up of the LED indicator on the unit, and by
the sounding of the buzzer.
Order Setting items Setting range Default value
4 Setting prompt voice volume 1~9 6
7Setting the nameplate
illumination mode On/Off/Auto On
8Setting night view LED
illumination mode On/Off/Auto Auto
Ringing one time
10 Setting image display mode
Alternate switching mode
Zoom mode
Full screen mode
Alternate switching mode
6 Setting the unlock time 01 to 99 seconds 5 seconds
6 Setting the unlock mode 0:opened
2 Setting camera N/P standard NTCS or PAL standard PAL standard
1 Setting door station address 0~3(DS 1 to 4) 0
3 Setting prompt voice Max. 2 Settings - Off or On Voice prompt On
Ring once
10 Setting ring-back tone Ring continuously
No ring-back tone
0 - Normally Open
1 - Normally Closed

-7-
Setting Door Station Address
UNLOCK Indicator:OFF
TALK Indicator:OFF Buzzer Beep+, Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep+
In standby mode, press
KEY_SET button once
Press KEY_1 button to set
the first door station.
Press KEY_2 button to set
the second door station.
Press KEY_3 button to set
the third door station.
Press KEY_4 button to set
the fourth door station.
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer Beep,Beep,Beep,Beep
SETUP INSTRUCTIONS
ID=0,1st door station ID=1,2nd door station ID=2,3rd door station ID=3,4th door station
A total of 4 addresses can be congured. The address can be modied either before or
after installation. 0(DS #1) is default, to change the address, please use the following
steps:
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the address of door station can be changed by pressing KEY1~4 cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.

-8-
Setting Prompt Voice
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Play the voice 1
Press KEY_3 button to set the
prompt voice to Voice 1.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Play the voice 2
Press KEY_3 button again
to set the prompt voice to
Voice 2.
Press KEY_3
SETUP INSTRUCTIONS
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+
Press KEY_2 button to set the
camera standard to P
standard.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep, Beep
Press KEY_2 button again
to set the camera standard
to N standard.
Press KEY_2
P(PAL) standard is default, to change the setting, please follow the steps:
The video standard of the camera can be changed at any time, that means the quality of
image on screen can be set to differ.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the calling mode can be changedby pressing KEY2cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.
There are 2 options Voice prompt on or off. On is default;to change
the setting please use the following steps:
Beep+
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer
Press KEY_3 button again
and again to set the prompt
voice to No voice.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the calling mode can be changedby pressing KEY3cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.
Setting The Camera NTSC/PAL Video Standard

-9-
SETUP INSTRUCTIONS
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button twice.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Play the volume
Press KEY_4 button to set the
volume level.
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer
Press KEY_4
Play the volume level 9
Press KEY_4 button again
and again to set the volume
level you want.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+
Press KEY_1 button to set
the unlock mode to
Normally opened.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep
Press KEY_1 button again
to set the unlock mode to
Normally closed.
Press KEY_1
Setting Prompt Voice Volume
A total of 9 volume levels can be congured. The levels can be modied either
before or after installation. 6 is default;to change the setting please use the
following steps:
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the volume level can be changedmode by pressing KEY4cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.
Setting The Unlock Mode
There are 2 unlock modes, Normally open and Normally closed. Normally opened
is default, to change the setting, please use the following steps:
• While in the setting mode, the calling mode can be changedby pressing KEY1 cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.
•
e setting mode manually press the KEY_
If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit th SET button four times.

-10-
Setting Nameplate Illumination Mode
Setting Unlock Time
SETUP INSTRUCTIONS
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep,Beep......
Press and hold on KEY_2
button. The time you holding
on is the new unlock time.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+
Press KEY_3 button to set
the nameplate illumination
mode to Normally on.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep
Press KEY_3 button again
to set the nameplate illumina-
tion mode to Normally off.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep,Beep
Press KEY_3 button again
and again to set the nameplate
illumination mode to Auto.
Press KEY_3
By default the unlock time is 1s,this can be changed from 1s~99s. To change the unlock
time please use the following steps:
• When holding button 2 to set the unlock time, the buzzer will sound one time every second
• The LED_NAME indicator will flash continually while in the setting mode.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• Press KEY_SET button twice to exit out the setting mode manually.
There are 3 illumination modes for the nameplate indicator, Normally on,Normally off and
Auto. Normally on is default, to change the setting, please follow the steps:
• If setting mode has not been exited, you can change the nameplate illumination mode by pressing KEY3
cyclically.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• The LED_NAME indicator will continually flash while in the setting mode.

-11-
Setting Ring-back Tone
Setting Night View LED Illumination Mode
SETUP INSTRUCTIONS
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+
Press KEY_4 button to set
the night view LED mode
to Normally on.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep
Press KEY_4 button again
to set the night view LED
mode to Normally off.
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep, Beep,Beep
Press KEY_4 button again
and again to set the night
view LED mode to Auto.
Press KEY_4
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button four
times.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+
Press KEY_1 button to set
the ring-back call tone ringing
one time.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep, Beep
Press KEY_1 button again
to set the ring-back call tone
ringing continuously.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep, Beep,Beep
Press KEY_1 button again
and again to close ring-back
call tone.
Press KEY_1
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
There are 3 working modes for night view LED indicator, Normally on,Normally off and Auto.
Auto is default, to change the setting, please follow the steps:
• While in the setting mode, the illumination mode can be changedby pressing KEY4cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.
Press the call button to call the monitor, a ring-back call tone can be heard from door station.
There are 3 ring-back call tones, Ring once, Ring continuously and No ring-back tone.
Ringing one time is default, to change the setting, please follow the steps:
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the calling mode can be changedby pressing KEY1 cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.

-12-
Setting Image Display Mode
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button four
times.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+
Press KEY_2 button to set
the image display mode
to Cycle switching.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep, Beep
Press KEY_2 button again
to set the image display
mode to Zoom mode.
UNLOCK Indicator:ON
CALL Indicator:ON
Press KEY_2
Buzzer Beep, Beep,Beep
Press KEY_2 button again
and again to set the image
display mode to Full screen.
During setting mode, press KEY-2 to switch
Cycle switching mode, Zoom mode and Full screen mode in cycle.
SETUP INSTRUCTIONS
When answering the call
Please note this setting is only for monitors that do not support manual pan, tilt and
zoom functions, i.e. CDV47M, CDV43 & CDV24.
When calling a monitor:
When a call is placed from door station to a monitor, the image is displayed on screen. There
are 3 modes for the image that can be displayed;Alternate switching mode,Zoom mode
and Full screen mode.
Alternate switching mode: when the monitor is called, the image will switch between Full
screen and Zoom image at a time interval of 5 seconds.
Full screen mode: when the monitor is called, the image will be displayed in Full screen.
Zoom mode: when the monitor is called, the image will be displayed on full screen for 5
seconds, then switch to Zoom image.
Alternate switching mode is the default.To change the setting, please use the following steps:
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the calling code can be changedmode by pressing KEY 2 cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.
When answering the call, the image switching reminder can be activated or deactiviated.
Alternate switching mode: When answering the call, image switching reminder is not shown.
Zoom mode: When answering the call, the image will be displayed on full screen for 5 sec-
onds, then switch to Zoom image as a reminder to enter the talk status.
If set to activated,the image switching reminder will be different for each image display mode,
see below.

-13-
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button four
times.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+
Press KEY_3 button to
activate image switching
when answering the call.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep, Beep
Press KEY_3 button again
to forbid image switching
when answering the call.
Press KEY_3
SETUP INSTRUCTIONS
Registering ID Card
By default there are two master cards marked MASTER CARD ADD and MASTER CARD
DELETE,new master cardscan be authorised by users at any time. This means any two user
cards can be authorised as master cards. When registered new master cards, the exisiting master
cards will be invalidated automatically.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• To exit the setting mode manually press the KEY_SET button four times.
• While in the setting mode, the calling code can be changedmode by pressing KEY 3 cyclically.
• The LED_NAME indicator will continually flash while in the setting mode.
Full screen mode: When answering the call, the image will be displayed on Zoom mode for 5
seconds, then switch to Full screen as a reminder to enter the talk status.
If deactivated, no image switching reminder is displayed on any image display mode.
Activated is default, to change the setting, please use the following steps:
• Card reading distance is less than 3cm.
• EM card, 125kHz.
• Cards = Tags
• A maximum of 320 user cards can be registered by the door station.
• Straight forward management with LED status and sound hints.
• There are two master cards, one MASTER CARD ADD
and one MASTER CARD DELETE.When registering new master
cards the exisiting master cards are invalidated automatically.
• The master cards are necessary when you add or delete user
cards. Please keep safe for future use.
Authorising master cards:

-14-
SETUP INSTRUCTIONS
UNLOCK Indicator:Blink two times
CALL Indicator:OFF
Buzzer Beep,Beep
Show the first card to ID
card window, set the card
of MASTER CARD ADD.
UNLOCK Indicator:Blink three times
CALL Indicator:OFF
Buzzer Beep,Beep,Beep
Show the second card to ID
card window, set the card of
MASTER CARD DELETE.
UNLOCK Indicator:OFF
CALL Indicator:OFF
Buzzer Beep+, Beep
When power on in 10s,press
and hold on KEY_SET button
for 3s.
UNLOCK Indicator:Blink one time
CALL Indicator:OFF
Buzzer Beep+
Press KEY_2 button.
Switching Access Control:
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
Show the master card of
MASTER CARD ADD to ID
card window in standby.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+, Beep
Show the master card of
MASTER CARD DELETE
to ID card window.
UNLOCK Indicator:OFF
CALL Indicator:OFF
Buzzer Beep+
Show the master card of
MASTER CARD DELETE
again to switch as a door
station access control.
UNLOCK Indicator:OFF
CALL Indicator:OFF
Buzzer Beep,Beep
Show the master card of
MASTER CARD DELETE
again to switch to DT-ACC
controlled.
Adding User Cards:
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
Show the master card of
MASTER CARD ADD to ID
card window in standby.
UNLOCK Indicator:OFF
CALL Indicator:Blink one time
Buzzer Beep+
Show user cards to be
added in sequence.
UNLOCK Indicator:OFF
CALL Indicator:OFF
Buzzer Beep, Beep+
Show the master card of
MASTER CARD ADD again
to exit.
• If no operation is carried out within 10 s the setting mode will exit automatically.
• The door station will exit the setting mode after showing both cards, The UNLOCK & TALK will turn off.
• The LED_NAME indicator will continually flash while in the authorisation mode.
• If no operation is carried out within 10 seconds,
ontrolled by CDV-A
the setting mode will exit automatically.
• If current access is controlled by door station, the next access setting will c CC.
• If
ation mu
no operation is carried out within 10 seconds, the setting mode will exit automatically.
• To add user cards the door st st be set for access. See above.

-15-
SETUP INSTRUCTIONS
Initializing Access (delete all user cards):
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
Show the master card of
MASTER CARD DELETE to
ID card window in standby.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+, Beep
UNLOCK Indicator:Blink for some time
CALL Indicator:Blink for some time
Buzzer Beep
Show the master card of
MASTER CARD ADD again,
format is activated.
Show the master card of
MASTER CARD ADD to ID
card window.
Deleting User Cards:
UNLOCK Indicator:ON
CALL Indicator:OFF
Buzzer Beep+, Beep
Show the master card of
MASTER CARD DELETE to
ID card window in standby.
UNLOCK Indicator:Blink one time
CALL Indicator:OFF
Buzzer Beep+
Show user cards to be
deleted in sequence.
UNLOCK Indicator:OFF
CALL Indicator:OFF
Buzzer Beep, Beep+
Show the master card of
MASTER CARD DELETE
again to exit.
Restore To Default
UNLOCK Indicator:OFF
CALL Indicator:ON
Buzzer Beep+, Beep
When power on in 10s,press
and hold on KEY_SET button
for 3s.
UNLOCK Indicator:ON
CALL Indicator:ON
Buzzer Beep+
Press KEY_3 button.
• If no operation is carried out within 10 seconds, the setting mode will exit automatically.
• To add user cards the door station must be set for access. See page 14.
• When formatting is nished, UNLOCK & TALK indicator will turn off , a “ Beep+ ” will be heard, and
door station will exit the setting mode automatically.
• To add user cards the door station must be set for access. See page 16.
• At step 3, the UNLOCK & TALK indicator will flash constantly until formatting is nished.
• If no operation is carried out within 10 seconds, the setting mode will exit automatically.
The 'restore to default'function allows the user to recover the factory settings.
• The LED_NAME indicator will blink twice per second while in the 'restore to default' mode.
• If no operation is carried out within 10 seconds, the setting mode will exit automatically.
• When restoring is completed, UNLOCK & CALL indicator will be turn off and the setting mode will
exit automatically.

-16-
Connecting Electric Lock
Door Lock Controlled with Internal Power
Door Lock Controlled with Dry Contact
1.The external power supply must be used
according to the lock.
2.The inside relay contact is restricted to
230Vac 1A or 24Vdc 1A.
3.The jumper must be taken off before
connecting.
4.Setup the Unlock Mode according to
different lock types.
• Power-on-to-unlock type:Unlock
Mode=0 (by default)
• Power-off-to-unlock type:Unlock
Mode=1
EB
*
LOCK
Jumper position on 2&3
1 2 3
L1 L2 PL S+ S-
Take off the jumper
1 2 3
L1 L2 PL S+ S-
LOCK
POWER
SUPPLY
WIRING
3.The jumper should be placed on position
2 and 3 before connecting.
1.Electronic lock of Power-on-to-unlock
(fail Secure) type should be used.
4.The door lock control is not timed from
Exit Button(EB).
2.The door lock is limited to 12V, and hold-
ing current must be less than 250mA.
5.The Unlock Mode is set to 0 (by
default).
* CDV-RLC relay actuator is required for 2nd lock connection.

-17-
Precautions
Specification
• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical
clean agent. If necessary, please use a little pure water or dilute soap water to clean the dust.
• The unit is weather resistant. However do not spray high pressure water on access control
keypad directly. Excessive moisture may cause problems with the unit.
• You must use the right adaptor which is supplied by the manufacture or approved by the
manufacture.
APPENDIX
• Pay attention to the high voltage inside the products, please refer service only to a trained
andqualiedprofessional.
●Power Supply :
12Vdc, 250mA(Internal Power);
●Unlock time: 1~99s(Default 1s);
●Number of relay circuits: 2 (the second lock need external
●device to support);
●Working temperature: -20ºC ~ +55ºC;
●Wiring: 2 wires,non-polarity;
●Protection: IP45;
●Dimension: 281(H)×110(W)×44(D)mm.
●Lock Power supply:
DC 24V;
●Power Consumption: Standby 1.2W; Working status 4.8W;
●Fish Camera: Color CMOS, 2.0 Mega pixel 1/2.7’’
fisheye camera,170° wide angle(CDV97);

-18-
APPENDIX
Cables and Requirments
The maximum distance of the wiring is limited in the DT system. Using different cables may also
affect the maximum distance which the system can reach.
Cable and distance(unit:m)
A
B
PC6A
RF CARD
Basic IN-OUT Wiring Mode
Cable Usage A B
≤2 IM
B
≤16 IM
Belden 9470 UTP 2x0.75mm260 100 40
Belden 8471 UTP 2x1mm280 120 60

-19-
B
A
C
2
2
DBC4A1
PC6A
RF CARD
Cable and distance(unit:m)
APPENDIX
Star Topology Wiring Mode With DBC4A1
Cable Usage A B C
Belden 9740 UTP 2x0.75mm260 60 30
Belden 8471 UTP 2x1mm280 80 40

The design and specifications can be changed without notice to the user. Right to interpret and copyright of this
manual are preserved.
CDV-ENG-97-8ID-V1 / 201708
Table of contents
Other CDVI Intercom System manuals

CDVI
CDVI CDV-91 User manual

CDVI
CDVI CD97-4ID User manual

CDVI
CDVI CDV91F User manual

CDVI
CDVI CDV-17HFA User manual

CDVI
CDVI 2Easy CDV4796KP-DX User manual

CDVI
CDVI CDV4791 User manual

CDVI
CDVI CDV4791S-DX User manual

CDVI
CDVI CDV-4791S-DXB User manual

CDVI
CDVI CDV-471IP User manual

CDVI
CDVI 2EASY CDV-850IP User manual