manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cree
  6. •
  7. Lighting Equipment
  8. •
  9. Cree OSQ Series User manual

Cree OSQ Series User manual

OSQ Series
LED Area Light
Direct Pole Mount
1 of 3 LPN00219X0001A5_A
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D’INSTALLATION
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should
always be followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1. DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l’alimentation avant
l’installation.
2. This luminaire must be installed in accordance with the NEC or
your local electrical code. If you are not familiar with these codes
and requirements, consult a qualied electrician.
Ce produit doit être installé conformément à NEC ou votre code
électrique local. Si vous n’êtes pas familier avec ces codes et
ces exigences, veuillez contacter un électricien qualié.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
DIRECT POLE MOUNT
NOTE: Access to Components Compartment
is not necessary for installation. To access
the Components Compartment, loosen (5)
self-retaining screws on the luminaire Cover
Door. See Figure 4.
STEP 1:
Verify that there is access from top of the
pole.
STEP 2:
Use dimensions on template shown on the
back page for drilling if pole is not pre-
drilled. (Template is not to scale.)
STEP 3:
From top of the pole insert Backing Plate
with pre-assembled top bolt through the top
mounting hole of the pole. See Figure 1.
STEP 4:
Remove any extra gaskets plugs from the
foam gasket and place gasket over bolt
extending from pole. See Figure 1.
STEP 5:
Place the top hole of the Pole Mount Adapter
over the top bolt from the pole and secure
from inside the adapter with supplied 5/16"
hex nut. See Figure 1.
STEP 6:
Install remaining bolt with star washer inside
the pole through the bottom hole of the
Backing Plate and thread into the Pole Mount
Adapter. Torque the 5/16" hex nut and bolt to
132 in-lbs (15 N-m). See Figure 2.
TO INSTALL:
12
Pole Mount Adapter
Backing
Plate
5/16” Hex Nut
Foam Gasket
Pole
Pole Mount Adapter
Backing Plate Pole
NOTES:
• DO NOT remove the knock out on the top of the luminaire
(See
Figure 3 on page 2). If a NEMA or photocontrol is desired
customer must order OSQ luminaire with factory installed
NEMA Photocell Receptacle (R option). NEMA photocell
receptacle or photo control’s are not field installable.
• Use a ½" socket with a minimum 9" extension to reach all
the way thru the arm to fasten the nut.
• A 3/16" Allen screw driver is needed to tighten the set
screws.
• Compatible with 3.0" or larger round or square poles.
• Prior to installation, store luminaire in a dry location protected from rain,
dust, and outdoor environment. If equipped with a photocell receptacle,
remove the protective cover only if immediately replacing with a suitable
photocell, shorting cap, or other compatible device. The protective socket
cover is not intended to remain in place after installation. Do NOT leave
receptacle open to environmental elements. Luminaires with a top-
mounted photocell receptacle should not be installed in an up-light position
or at a tilt greater than 45 degrees from the down-light position.
2 of 3 LPN00219X0001A5_A
STEP 7:
Route the cord coming from the fixture head through
the Pole Mount Adaptor and then through the pole.
See Figure 3.
STEP 8:
Slide the mounting arm of the luminaire over the
Pole Mount Adaptor as shown in Figure 3.
STEP 9:
Tighten (4) 3/8-16 socket head set screws located on
the top of the mounting arm to
85 in-lbs (9.6 N•m). See Figure 3.
STEP 10:
See the Electrical Connections section for wiring
instructions.
NEMA®RECEPTACLE (OPTIONAL)
STEP 1:
Remove protective cap.
STEP 2:
Rotational adjustment of the photocontrol receptacle
is tool-less . DO NOT loosen/tighten the screws
securing the receptacle to the housing.
STEP 3:
Engage/install photocontrol into photocontrol
receptacle on to of luminaire.
STEP 4:
If necessary, rotate photo-control so its photo-eye is
aimed in the north direction. Some photo-controls
operate best somewhere between north-west and
north-east.
FIELD ADJUSTABLE DIMMING  (OPTIONAL)
NOTE: This luminaire may be provided with field
adjustable dimming. If so, luminaires leave the
factory adjusted to the maximum setting specified
when ordered. Visit www.cree.com/Lighting/
Document-Library for product dimming spec sheet.
STEP 1:
The Dimming module is located inside the luminaire.
Open the luminaire door cover by loosening the (5)
screws. See Figure 4.
STEP 2:
Establish the desired input power multiplier by
referring to the product dimming spec sheet and turn
the switch to the correlating position
STEP 3:
Adjust the Dimming Module, see Figure 5, to the
selected position and reinstall the cover ensuring no
wires are pinched.
DRV
DRV CRTL
1 2 3 4 5
9123
4
5
6
7
8
5
3
Socket Head Screws
Pole Mount Adapter
Luminaire Cover Door
4
DO NOT remove knockout
3 of 3 LPN00219X0001A5_A
www.lighting.cree.com
© 2018 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change.
See http://lighting.cree.com/warranty for warranty and specifications. Cree®is a registered trademark, and the Cree logo is a
trademark of Cree, Inc. NEMA® is a registered trademark of the National Electrical Manufacturers Association.
2.000"
(51 mm)
2.000"
(51 mm)
1"
(25 mm)
0.344"
(9 mm)
Hole
2 Required
0.79"
(20 mm)
Hole
POLE TEMPLATE
ELECTRICAL CONNECTIONS
STEP 1:
NOTE: For luminaires with PML sensor will have the dimming
leads capped off. Keep the dimming leads on these luminaires
capped off.
Using Listed 90°C minimum rated wire connectors make the
following electrical connections within the adjustable fitter
wiring compartment:
a. For 120/277/347V connect the black fixture lead to the
voltage supply or Hot 1 (for 208/240/480V wiring).
b. For 120/277/347V connect the white fixture lead to the
neutral supply or Hot 2 (for 208/240/480V wiring).
c. Connect the green or green/yellow ground lead to
ground.
d. If Dimming is an option; connect the blue dimming
positive fixture lead to the supply dimming positive lead.
e. If Dimming is an option; connect the white/black
dimming negative fixture lead to the supply dimming
negative lead.
f. Connect orange fixture lead to orange supply lead.
g. Connect red fixture lead to brown supply lead.
LINE
OR HOT 1
GREEN
LINE-BLACK
GROUND-GREEN
NEUTRAL-WHITE
DIM (-)
WHITE/BLACK
DIM (+) BLUE
NEUTRAL
OR HOT 2
VIOLET
GREY
SUPPLY WIRING
(DIMMING OPTIONAL)
LUMINAIRE
RED
ORANGE
BROWN
(CONTROLS FROM
PHOTOCONTROL
OPTIONAL)
ORANGE

Other Cree Lighting Equipment manuals

Cree OSQ HO Series User manual

Cree

Cree OSQ HO Series User manual

Cree LQ6 Series User manual

Cree

Cree LQ6 Series User manual

Cree Essentia S-DL4-EB User manual

Cree

Cree Essentia S-DL4-EB User manual

Cree XLamp ML Family LEDs User manual

Cree

Cree XLamp ML Family LEDs User manual

Cree LS8 User manual

Cree

Cree LS8 User manual

Cree FLEX Series User manual

Cree

Cree FLEX Series User manual

Cree CR24 UPKIT User manual

Cree

Cree CR24 UPKIT User manual

Cree XLamp MH Series User manual

Cree

Cree XLamp MH Series User manual

Cree ZR Series User manual

Cree

Cree ZR Series User manual

Cree XLamp XR Series User manual

Cree

Cree XLamp XR Series User manual

Cree SmartCast FLEX Series User manual

Cree

Cree SmartCast FLEX Series User manual

Cree C-AR Series User manual

Cree

Cree C-AR Series User manual

Cree EB14SMK User manual

Cree

Cree EB14SMK User manual

Cree CR Series User manual

Cree

Cree CR Series User manual

Cree CPY Series User manual

Cree

Cree CPY Series User manual

Cree TRDL6 Series User manual

Cree

Cree TRDL6 Series User manual

Cree CXB Series User manual

Cree

Cree CXB Series User manual

Cree OSQ Series User manual

Cree

Cree OSQ Series User manual

Cree XA-NEMA User manual

Cree

Cree XA-NEMA User manual

Cree ESSENTIA AE Series User manual

Cree

Cree ESSENTIA AE Series User manual

Cree ESSENTIA ESA-ADR-414 User manual

Cree

Cree ESSENTIA ESA-ADR-414 User manual

Cree CR150-650L User manual

Cree

Cree CR150-650L User manual

Cree C-LITE C-WP-A-FCT3 Series User manual

Cree

Cree C-LITE C-WP-A-FCT3 Series User manual

Cree LXB Series User manual

Cree

Cree LXB Series User manual

Popular Lighting Equipment manuals by other brands

Chauvet SlimPAR 64 user manual

Chauvet

Chauvet SlimPAR 64 user manual

Bosch MIC7000 Quick installation guide

Bosch

Bosch MIC7000 Quick installation guide

CPI ACM-125 Installation

CPI

CPI ACM-125 Installation

DOTLUX 4997-040270 user manual

DOTLUX

DOTLUX 4997-040270 user manual

AQUALUX VITALIA installation manual

AQUALUX

AQUALUX VITALIA installation manual

DÖRR FX-1520 DL instruction manual

DÖRR

DÖRR FX-1520 DL instruction manual

EuroLite LED PAR-64 Spot user manual

EuroLite

EuroLite LED PAR-64 Spot user manual

American DJ X-Move LED Plus User instructions

American DJ

American DJ X-Move LED Plus User instructions

Aqua Creek Products Cycle Attachment Quick start manual

Aqua Creek Products

Aqua Creek Products Cycle Attachment Quick start manual

Chauvet Scorpion 3D RGB user manual

Chauvet

Chauvet Scorpion 3D RGB user manual

ACME LED-PS10 user manual

ACME

ACME LED-PS10 user manual

GAME OF BRICKS Thor's Hammer 76209 instruction manual

GAME OF BRICKS

GAME OF BRICKS Thor's Hammer 76209 instruction manual

Original BTC Cecil FT554 instruction manual

Original BTC

Original BTC Cecil FT554 instruction manual

Robe Robin 600E Beam user manual

Robe

Robe Robin 600E Beam user manual

Standard LED SHOPLIGHT installation instructions

Standard

Standard LED SHOPLIGHT installation instructions

Melink ML1B5W20-GU15RGBCCT instruction manual

Melink

Melink ML1B5W20-GU15RGBCCT instruction manual

Lightolier Calculite ProSpec PA3P3075 specification

Lightolier

Lightolier Calculite ProSpec PA3P3075 specification

Ingersoll-Rand L6 Operation & maintenance manual

Ingersoll-Rand

Ingersoll-Rand L6 Operation & maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.