Failure to install or use this product according to manufacturer’s recommendations may result in property
damage, serious injury, and/or death to those you are seeking to protect!
!
WARNING!
1. Proper installation combined with operator training in the use, care, and maintenance of emergency warning devices are essential to
ensure the safety of you and those you are seeking to protect.
2. Exercise caution when working with live electrical connections.
3. This product must be properly grounded. Inadequate grounding and/or shorting of electrical connections can cause high current
arcing, which can cause personal injury and/or severe vehicle damage, including re.
4. Proper placement and installation are vital to the performance of this warning device. Install this product so that output performance
of the system is maximized and the controls are placed within convenient reach of the operator so that s/he can operate the system
without losing eye contact with the roadway.
5. Do not install this product or route any wires in the deployment area of an air bag. Equipment mounted or located in an air bag
deployment area may reduce the eectiveness of the air bag or become a projectile that could cause serious personal injury or death.
Refer to the vehicle owner’s manual for the air bag deployment area. It is the responsibility of the user/operator to determine a suit-
able mounting location ensuring the safety of all passengers inside the vehicle particularly avoiding areas of potential head impact.
6. It is the responsibility of the vehicle operator to ensure during use that all features of this product work correctly. In use, the vehicle
operator should ensure the projection of the warning signal is not blocked by vehicle components (i.e., open trunks or compartment
doors), people, vehicles or other obstructions.
7. The use of this or any other warning device does not ensure all drivers can or will observe or react to a warning signal. Never take
the right-of-way for granted. It is your responsibility to be sure you can proceed safely before entering an intersection, driving against
trac, responding at a high rate of speed, or walking on or around trac lanes.
8. This equipment is intended for use by authorized personnel only. The user is responsible for understanding and obeying all laws
regarding warning signal devices. Therefore, the user should check all applicable city, state, and federal laws and regulations. The
manufacturer assumes no liability for any loss resulting from the use of this warning device.
Do not install and/or operate this safety product unless you have read and understand the safety information
contained
Specications:
Size: W: 167mm Dia. x 85mm H
Weight: 0.85kg
Voltage: 10-32V DC Systems
Current Draw @ 13.8VDC: 4.4A Peak, 1.6A Max
Current Draw @ 27.6VDC: 2.2A Peak, 0.8A Max
Flash Rate: See Flash Pattern Chart
Temp. Range: -40°C to +60°C
Reverse polarity protection.
Ambient light sensor (refer ash pattern table).
Certications: Ingress Protection: IP69K
EMC: ECE R10, CISPR-25, ACMA RCM
SAE J845 Class 1 - refer ash pattern table.
Installation & Mounting:
Carefully remove the beacon and place it on a at surface. Examine the
unit for transit damage, broken lenses, etc. If damage is found, contact the
transit company or distributor. Do not use damaged or broken parts.
Permanent Mounting:
Caution: When drilling into any vehicle surface, make sure the area
is free from any electrical wires, fuel lines, vehicle upholstery, etc. that
could be damaged
Position the beacon in the desired mounting location. Using the base ange
as a template, mark the mounting hole locations. Drill three 5.2mm mounting
holes. Drill a hole for power wire routing as desired. The use of a grommet
or silicone is required for wires passing through compartment walls, or
where sealing is required. Secure the beacon in place using the included
#10 hardware.
Installation and Operating Instructions
EB8160 - Heavy duty beacon
Wiring Instructions:
Important! This unit is a safety device, and it must be connected to
its own separate, fused power point to assure its continued operation
should any other electrical accessory fail.
Wiring for single colour beacons is as shown in FIGURE 1. All wiring should
be a minimum of 2mm². The positive line must have a 10A automotive
fuse, as shown. A switch may be used to control the on/o function. Route
the ground wire directly back to negative battery terminal. Pack dielectric
grease, such as Dow Corning 4, around each electric connection exposed
to moisture or the ambient environment.
Important! Disable power before wiring the beacon.

Page 2 of 4
Wire Functions:
Wire: Function:
Red Positive
Black Negative
Yellow Sync
Blue Flash pattern change to Negative
Flash Pattern Selection:
Apply Blue to Black wire:
Push Times: Function:
0 ~ 1 sec. next pattern
1 ~ 3 sec. previous pattern
3 ~ 5 sec. factory default pattern
5 ~ sec. last pattern
Synchronisation:
Syncing capabilities are available with all compatible ECCO products via the yellow wire with the ash patterns indicated in the charts below:
1. Determine the desired style of ash pattern for each unit and set each unit individually (without the yellow wires connected together) to avoid confusion. It
is also strongly recommended that the same style of ash pattern be used on all units to produce the most eective warning pattern. NOTE: Phases 1 and 2
for each style of ash pattern in the table denote the relative timing between units connected in a synchronizing installation. To operate simultaneously, each
unit must be set to the same phase (1 + 1 or 2 + 2); to operate alternately, units must be set to have the opposite phase (1+ 2 or 2 + 1).
2. Connect the yellow sync wires together and check that the units are ashing in a synchronized manner as expected. If a pattern on one unit appears
incorrect, the blue pattern select wire can be used to cycle forward or backward on that individual unit until the correct pattern is selected. Note: This will only
change the pattern in the one unit and will not aect the other units connected to the yellow sync wire.
3. If the yellow wire is unused, leave unconnected and insulated.
EB8160A LED Beacon Flash Patterns
PATTERN MODE DESCRIPTION SYNC FPM SAE J845 T13 AUTO DIM
1 1 Single Flash Phase 1 Yes
75 CLASS 1A CLASS E No
2 Single Flash Phase 2 Yes
2 3 Single Flash Phase 1 Yes
120 CLASS 1A Yes
4 Single Flash Phase 2 Yes
3 5 Double Flash Phase 1 Yes
75 CLASS 1A CLASS E No
6 Double Flash Phase 2 Yes
4 7 Double Flash Phase 1 Yes
120 CLASS 1A Yes
8 Double Flash Phase 2 Yes
59Quad Flash Phase 1 Yes
75 CLASS 1A No
10 Quad Flash Phase 2 Ye s
611 Quad Flash Phase 1 Yes
120 CLASS 1A Yes
12 Quad Flash Phase 2 Ye s
7 13 Slow Rotate Phase 1 Yes
120 No
14 Slow Rotate Phase 2 Yes
8 15 Fast Rotate Phase 1 Ye s
150 No
16 Fast Rotate Phase 2 Ye s
917 Rotate / Quad Phase 1 Yes N/A No
10 18 Pulse Phase 1 Yes
60 No
19 Pulse Phase 2 Yes
11 20 Steady Burn No N/A No

Page 3 of 4
THIS PAGE INTENTIONALLY LEFT BLANK

920-0844-00 (Rev C)
© 2021 ECCO Safety Group
ECCO Safety Group Asia Pacic
439 Boundary Rd,Truganina
Melbourne
VIC 3029
+61 (03)8336 0666
www.eccoesg.com/auPage 4 of 4
Manufacturer Limited Warranty and Limitation of Liability:
Manufacturer warrants that on the date of purchase, this product will conform to Manufacturer’s specications for this product
(which are available from the Manufacturer upon request). This Limited Warranty extends for sixty (60) months from the date of
purchase.
DAMAGE TO PARTS OR PRODUCTS RESULTING FROM TAMPERING, ACCIDENT, ABUSE, MISUSE, NEGLIGENCE,
UNAPPROVED MODIFICATIONS, FIRE OR OTHER HAZARD; IMPROPER INSTALLATION OR OPERATION; OR NOT BEING
MAINTAINED IN ACCORDANCE WITH THE MAINTENANCE PROCEDURES SET FORTH IN MANUFACTURER’S
INSTALLATION AND OPERATING INSTRUCTIONS VOIDS THIS LIMITED WARRANTY.
Exclusion of Other Warranties:
MANUFACTURER MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED. THE IMPLIED WARRANTIES FOR
MERCHANTABILITY, QUALITY OR FITNESS FOR A PARTICULAR PURPOSE, OR ARISING FROM A COURSE OF DEALING,
USAGE OR TRADE PRACTICE ARE HEREBY EXCLUDED AND SHALL NOT APPLY TO THE PRODUCT AND ARE HEREBY
DISCLAIMED, EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW. ORAL STATEMENTS OR REPRESENTATIONS
ABOUT THE PRODUCT DO NOT CONSTITUTE WARRANTIES.
Remedies and Limitation of Liability:
MANUFACTURER’S SOLE LIABILITY AND BUYER’S EXCLUSIVE REMEDY IN CONTRACT, TORT (INCLUDING
NEGLIGENCE), OR UNDER ANY OTHER THEORY AGAINST MANUFACTURER REGARDING THE PRODUCT AND ITS USE
SHALL BE, AT MANUFACTURER’S DISCRETION, THE REPLACEMENT OR REPAIR OF THE PRODUCT, OR THE REFUND OF
THE PURCHASE PRICE PAID BY BUYER FOR NON-CONFORMING PRODUCT. IN NO EVENT SHALL MANUFACTURER’S
LIABILITY ARISING OUT OF THIS LIMITED WARRANTY OR ANY OTHER CLAIM RELATED TO THE MANUFACTURER’S
PRODUCTS EXCEED THE AMOUNT PAID FOR THE PRODUCT BY BUYER AT THE TIME OF THE ORIGINAL PURCHASE. IN
NO EVENT SHALL MANUFACTURER BE LIABLE FOR LOST PROFITS, THE COST OF SUBSTITUTE EQUIPMENT OR LABOR,
PROPERTY DAMAGE, OR OTHER SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES BASED UPON ANY CLAIM FOR
BREACH OF CONTRACT, IMPROPER INSTALLATION, NEGLIGENCE, OR OTHER CLAIM, EVEN IF MANUFACTURER OR A
MANUFACTURER’S REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. MANUFACTURER
SHALL HAVE NO FURTHER OBLIGATION OR LIABILITY WITH RESPECT TO THE PRODUCT OR ITS SALE, OPERATION AND
USE, AND MANUFACTURER NEITHER ASSUMES NOR AUTHORIZES THE ASSUMPTION OF ANY OTHER OBLIGATION OR
LIABILITY IN CONNECTION WITH SUCH PRODUCT.
This Limited Warranty denes specic legal rights. You may have other legal rights which vary from jurisdiction to
jurisdiction. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages.
Warranty
Table of contents
Other Ecco Security System manuals

Ecco
Ecco EB5200 Owner's manual

Ecco
Ecco EB7180 Series User manual

Ecco
Ecco Pulse II 7945 Series User manual

Ecco
Ecco EB7260 Series User manual

Ecco
Ecco 400 Series Owner's manual

Ecco
Ecco 7945 User manual

Ecco
Ecco K7000B User manual

Ecco
Ecco 7965 Series User manual

Ecco
Ecco B200 R65 Manual

Ecco
Ecco EB7930 Series User manual
Popular Security System manuals by other brands

Honeywell
Honeywell Frieland FGGA06 Series Quick installation guide

Nilfisk-Advance
Nilfisk-Advance 56305519 installation instructions

Regency
Regency MCA-611 Service manual

Atwood
Atwood LPCO User and installation instructions

Serene
Serene CentralAlert CA-360 user manual

Nakamichi
Nakamichi EQ-Z1825 user manual