SET ADJ
SET ADJ
SET ADJ
SET ADJ
SET ADJ
SET ADJ
SET ADJ
SET ADJ
SET ADJ
SET ADJ
SET ADJ
SET ADJ
5:39
F
H M
5:39
f
H M
5:39
f
H M
5:39
f
H M
8:39
f
H M
8:39
f
H M
8:09
f
H M
8:09
f
H M
8:06
f
H M
8:06
f
H M
8:06
f
H M
00.0
8:06
f
H M
0
TT
U
R
1
TOFF
TON
TOFF
TON
U
R
2
TOFF
TON
TOFF
TON
U
R
3
TT
U
R
4
t1
T + t1 + t2
t2
T
U
B1
R
5
t1
T + t1 + t2
t2
T
U
B1
R
6
t1
T + t1 + t2
t2
T
U
B1
R
7
T
U
B1
R
8
T
U
B1
R
9
T T
U
B1
R
A
T T
U
B1
RT
B
T
U
B1
RT
B
T
U
B1
RT
C
T
U
B1
RT T
D
T
U
B1
R
E
T
U
B1
R
F
T
U
B1
RT
G
T OFF
U
B1
R
TON
2 / 3
Function
ON delay [0]
Timing commences when supply is present. R energizes at
the end of the timing period.
Programming instruction
Apply power & hold the SET key for > 3 sec.
Press both ADJ & SET key for > 3 sec. After power ON.
Now follow the steps given below
OR
KEY DISPLAY RESULT
Press ADJ key to select desired function (e.g. F)
Conrms function Then Range indicator blinks
Press ADJ key to select range (e.g. HM range ‘HM‘)
Conrms range selection. 1st digit of Preset time blinks.
(For modes ‘1’ , ‘2’ & ‘G’ two preset times ‘On’ & ‘O’ to
be set)
Change with ADJ Key (e.g.from 3 to 0)
Press Set to conrm 1st digit selection, now 2nd digit
blinks
Press ADJ key to adjust desired preset time digit (e.g.from
5 to 8)
Conrms 2nd digit selection, now 3rd digit of Preset Time
blinks.
Change with ADJ Key (e.g. from 9 to 6)
Now UP / DOWN Indicator blinks
Change with ADJ Key (e.g.from DOWN to UP)
Conrms counting mode.
Program Over.
Timer starts working normally.
Cyclic OFF/ON {OFF Start, (Sym, Asym)} [1]
T-ON and T-OFF can be same or dierent. The relay (R) keeps
on changing its status till power is removed.
Cyclic ON/OFF{On Start,(Sym,Asym)} [2]
This function is quite similar to the function ‘1’ but initially
the relay(R) is ON for period T-ON after the power is applied.
Impulse ON energizing [3]
After power ON, R energizes and timing starts. R de-ener-
gizes after timing is over.
Accumulative delay ON signal [4]
Time commences as supply is present and switch B1 is open.
Closing switch B1 pauses timing. Timing resumes when
switch B1 is opened again. R energizes at the end of timing.
Accumulative delay ON inverted signal [5]
Time commences as supply is present and switch B1 is
closed. Opening switch B1 pauses timing. Timing resumes
when switch B1 is closed again. R energizes at end of timing.
Signal ON delay [7]
Permanent supply required. Timing starts when switch B1 is
closed. R energizes at end of timing period and de-energiz-
es when B1 is opened.
Inverted signal ON delay [8]
Timing will commence when supply is present and switch
B1 is open. R energizes after timing. If B1 is closed during
timing period, timing resets to the beginning of cycle.
Signal OFF delay [9]
Permanent supply is required. R energizes when switch B1
is closed. Timing commences after S is opened and then the
relay de-energizes.
Impulse ON/OFF [A]
Permanent supply is required. R energizes for the timing pe-
riod when B1 is opened or closed. When timing commenc-
es, changing state of B1 does not aect R but resets timer.
Signal OFF/ON [b]
When switch B1 is closed or opened for preset time ,T, the
relay changes its state after time duration T.
Leading edge impulse1 [C]
A permanent supply is needed. When B1 is closed, output
relay energizes until timing irrespective of any further ac-
tion of B1.
Leading edge impulse2 [d]
Permanent supply is required. when switch B1 is closed, and
remains closed output relay energizes until timing is over. If
B1 is opened during timing, R resets.
Trailing edge impulse1 [E]
Permanent supply required. when B1 is opened, R energizes
and de-energizes when timing is over. If B1 is closed during
timing R resets.
Trailing edge impulse2 [F]
Permanent supply is required. When switch B1 is opened,
R energizes and will de-energize when timing is over. If B1
is pulsed during timing period it will have no eect on R.
Delayed impulse [G]
When switch B1 is closed, TOFF starts. Relay energizes at the
end of TOFF period. Then, TOFF starts irrespective of signal
level and relay de-energizes at the end of TON period.
Accumulative impulse ON signal [6]
When supply is ON, R energizes. When switch B1 is closed
timing is suspended and remains suspended till switch B1 is
opened again. Interrupting supply resets timer.
Important Note:
1. Output de-energizes when device enters into PROGRAM MODE and starts new cycle after
coming out of PROGRAM MODE.
2. Loads which have current requirement > 1mA, can only be used as Optional Load. For e.g.
Contactor Coil, AC Relay Coil, etc.