Gree XK86 User manual

Owner's Manual
Original Instructions
Wired Controller (XK86 and XE76-33/H)

To Users
Thank you for selecting Gree’s product. Please read this instruction manual
carefully before installing and using the product, so as to master and correctly use the
product. In order to guide you to correctly install and use our product and achieve
expected operating effect, we hereby instruct as below:
(1) This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsibility for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
(2) This instruction manual is a universal manual, some functions are only
applicable to particular product. All the illustrations and information in the
instruction manual are only for reference, and control interface should be
subject to actual operation.
(3) In order to make the product better, we will continuously conduct
improvement and innovation. We have the right to make necessary revision
to the product from time to time due to the reason of sales or production, and
reserve the right to revise the contents without further notice.
(4) For personal injury or property loss and damage caused by improper

operation such as improper installation and debugging, unnecessary
maintenance, violation of related national laws and rules and industrial
standard, and violation of this instruction manual, etc., we will bear no
liability.
(5) The final right to interpret for this instruction manual belongs to Gree Electric
Appliances Inc. of Zhuhai.
This marking indicates that this product should not be disposed
with other household wastes throughout the EU. To prevent
possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote
the sustainable reuse of material resources. To return your used
device, please use the return and collection systems or contact
the retailer where the product was purchased. They can take
this product for environmental safe recycling.

Contents
1 Safety Notices (Please be sure to abide them) .................1
2 Operation Notices................................................................2
3 Appearance and Display .....................................................4
4 Status Bar Instructions .......................................................5
5 Installation and Commissioning.........................................7
5.1 Installation of Wired Controller ...............................................11
5.2 Commissioning ..................................................................... 20
6 Operation Instructions ......................................................30
6.1 On/Off ................................................................................... 30
6.2 Mode Setting......................................................................... 31
6.3 Temperature Setting.............................................................. 33
6.4 Fan Setting ........................................................................... 34
6.5 Schedule Setting................................................................... 35
6.6 Function Setting .................................................................... 40
6.7 Service Hotline Query ........................................................... 51
6.8 Language Setting.................................................................. 52

6.9 Sound Setting ....................................................................... 52
6.10 Date and Time Setting......................................................... 52
6.11 Remote Shield Function ...................................................... 52
6.12 Gate-control Function.......................................................... 53
6.13 Inquiry of Indoor Temperature with One Button ................... 53
7 Error Display ......................................................................53
7.1 Table of Error Codes for Outdoor Unit ................................... 54
7.2 Table of Error Codes for Indoor Unit...................................... 56
7.3 Table of Debugging Codes .................................................... 59
7.4 Table of Status Codes ........................................................... 61

Wired Controller (XK86 and XE76-33/H)
1
1 Safety Notices (Please be sure to abide them)
WARNING: If not abide them strictly, it may cause severe damage to the unit or the
people.
NOTE: If not abide them strictly, it may cause slight or medium damage to the unit or the
people.
This sign indicates that the items must be prohibited. Improper operation may cause
severe damage or death to people.
This sign indicates that the items must be observed. Improper operation may cause
damage to people or property.
WARNING!
This product can’t be installed at corrosive, inflammable or explosive
environment or the place with special requirements, such as kitchen.
Otherwise, it will affect the normal operation or shorten the service life of the
unit, or even cause fire hazard or serious injury. As for the above special
places, please adopt special air conditioner with anti-corrosive or
anti-explosion function.

Wired Controller (XK86 and XE76-33/H)
2
2 Operation Notices
The power supply for all indoor units must be unified.
Prohibit installing the wired controller at wet or sunshine places.
Do not knock, throw or frequently disassemble the wired controller.
Do not operate the wired controller with wet hands.
When the system mode priority is the master-slave mode, in one system network,
you must set one indoor unit as the master indoor unit, Other indoor units are slave
indoor units .
When the system mode priority is the master-slave mode, the operation mode of
the system is basing on that of the master indoor unit. The master indoor unit can
be set to any mode (including auto mode), while the slave indoor unit can’t set to
the mode that conflicts with the system mode.
When the system mode priority is: Cooling mode is prioritized, heating mode is
prioritized, first-set mode is prioritized, or last-set mode is prioritized. The indoor
unit can be set to any mode (excluding auto mode). The indoor unit will
automatically switch to the system mode, when the operation mode of the indoor
unit conflicts with the system operation mode.
When the system mode priority is the voting mode (indoor unit’s capacity is
prioritized / number of indoor units is prioritized). The indoor unit can be set to any
mode (excluding the auto mode). The indoor unit will be stopped, when the
operation mode of the indoor unit conflicts with the system operation mode after
voting.

Wired Controller (XK86 and XE76-33/H)
3
System mode priority defaults to master-slave mode, and only certain units have
other system mode priorities.
When two wired controllers control one (or more) indoor unit(s), the address of
wired controller should be different.
Functions with “*” are optional for indoor units. If a function is not included in an
indoor unit, wired controller can’t set the function, or setting of this function is
invalid to the indoor unit.

Wired Controller (XK86 and XE76-33/H)
4
3 Appearance and Display
Fig.3.1 Appearance and display

Wired Controller (XK86 and XE76-33/H)
5
Table 3.1 Appearance and display instructions
No.
Name
Instructions
1 LED Light up when buttons are pressed or signals are
received from remote controller
2 Remote signal receiving
window
For receiving signals from remote controller
3 Mode display Indicating the operating mode
4 Names of buttons Indicating the names of buttons
5 Touch buttons Corresponding to the names of buttons
6 Temperature display Display set temperature or environment temperature
7 Fan speed display Indicating set fan speed
8
Status bar
Indicating date, time, and activated functions
4 Status Bar Instructions
Table 4.1 Status bar instructions
Icon
Name
Instructions
Up and down
swing Up and down swing
Left and right
swing Left and right swing
Master
If the current wired controller is connected with a master indoor
unit, this icon will be displayed (If it is connected with a heat
recovery unit or temperature-humidity dual-control duct type
indoor unit, this icon won’t be displayed)

Wired Controller (XK86 and XE76-33/H)
6
Icon
Name
Instructions
Group control If one wired controller is controlling multiple indoor units, this
icon will be displayed
Slave wired
controller
Indicating the current wired controller is a salve wired controller
(address is 02)
Shield Shield status
Gate-control Indicating the gate-control card is pulled out
Child lock Child lock status
Invalid Indicating invalid operation
Malfunction Indicating that the unit is malfunctioning
Memory Memory status (When power is connected after power failure,
indoor unit will resume its previous settings)
Defrost Indicating that outdoor unit is under defrosting status
Schedule Indicating schedule function is activated
Clean Indicating filter cleaning reminder is on

Wired Controller (XK86 and XE76-33/H)
7
5 Installation and Commissioning
(1) Dimension and parts of XE76-33/H:
Unit: mm
Fig. 5.1 Dimension of XE76-33/H

Wired Controller (XK86 and XE76-33/H)
8
Fig. 5.2 Parts of XE76-33/H
No. ①②③④
Name Panel of wired
controller
Screw M4*25 Soleplate of
wired controller
Junction box mounted in
the wall space
QTY 1 2 1 Parts supplied by users

Wired Controller (XK86 and XE76-33/H)
9
(2) Dimension and parts of XK86:
Unit: mm
Fig. 5.3 Dimension of XK86

Wired Controller (XK86 and XE76-33/H)
10
Fig. 5.4 Parts of XK86
No. ①②③④
Name Panel of wired
controller
Screw M4*25 Soleplate of
wired controller
Junction box mounted in
the wall space
QTY 1 2 2 Parts supplied by users

Wired Controller (XK86 and XE76-33/H)
11
5.1 Installation of Wired Controller
5.1.1 Communication Line Selection
Fig. 5.5 Length of communication line
Wire material
type
Total length of
communication
line between
indoor unit and
wired controller L
(m/feet)
Wire
size
(mm2/A
WG)
Material
standard Remarks
Light/Ordinary
polyvinyl
chloride
sheathed cord.
(60227 IEC 52
/60227 IEC 53)
L≤250m
(L≤820-1/5feet)
2×0.75~
2×1.25
(2×AWG
18~2×A
WG16)
IEC
60227-5:
2007
①
Total length of communication
line can't exceed 250m
(820-1/5feet).
②
The cord shall be Circular cord
(the cores shall be twisted
together).
③
If unit is installed in places
with intense magnetic field or
strong interference, it is
necessary to use shielded
wire.

Wired Controller (XK86 and XE76-33/H)
12
NOTES:
①If the air conditioner is installed at the strong electromagnetic interference
place, communication line of the wired controller must use shielding twisted
pair.
②Materials of communication line for wired controller must be selected
according to this instruction manual strictly.
5.1.2 Installation Requirements
(1) Prohibit installing the wired controller at wet places.
(2) Prohibit installing the wired controller at direct sunshine places.
(3) Prohibit installing the wired controller at the place near high temperature
objects or water-splashing places.
(4) Prohibit installing the wired controller at the place where faces forward to
the window. Prevent abnormal work due to the interference from the other
wired controller around.

Wired Controller (XK86 and XE76-33/H)
13
5.1.3 Wiring Requirements
There are four network wiring methods between wired controller and indoor
unit:
Fig. 5.6 One wired controller
controls one indoor unit
Fig. 5.7 Two wired controllers
control one indoor unit

Wired Controller (XK86 and XE76-33/H)
14
Fig. 5.8 One wired controller controls multiple indoor units simultaneously
Fig. 5.9 Two wired controllers control multiple indoor units simultaneously

Wired Controller (XK86 and XE76-33/H)
15
Wiring instruction:
(1) When one wired controller controls multiple indoor units simultaneously, the
wired controller can connect to any one indoor unit, but the connected ones
must be units of the same series. The total quantity of indoor unit controlled
by wired controller can't exceed 16 sets, and the connected indoor unit
must be within the same network. The number of indoor units in group
control must be set. Please refer to section 5.2.2 Parameter Setting for the
setting method.
(2) When two wired controllers control one indoor unit, the addresses of those
two wired controllers should be different. One should be master controller
and the other should be slave controller. Please refer to section 5.2.2
Parameter Setting for the setting method.
(3) When two wired controllers control multiple indoor units simultaneously,
they can connect to any one indoor unit, but the connected ones must be
units of the same series. One should be master controller and the other
should be slave controller. Please refer to 5.2.2 Parameter Setting for the
setting method of master and slave wired controllers. The total quantity of
units controlled by wired controller can't exceed 16 sets, and the connected
indoor units must be within the same network. The number of units in group
control must be set. Please refer to section 5.2.2 Parameter Setting for the
setting method.
(4) When one (or two) wired controller(s) control (s) multiple indoor units at the
This manual suits for next models
1
Table of contents
Other Gree Controllers manuals
Popular Controllers manuals by other brands

Heatit Controls
Heatit Controls Z-PUSHaZ-PUSH 45 126 92 Installer manual

YASKAWA
YASKAWA Motoman DX200 instructions

Thermolec
Thermolec DCC-9-BOX-3R installation manual

SOMFY
SOMFY animeo IB+ 1860209 installation guide

McQuay
McQuay RVSS14 Installation, operation and maintenance manual

IMC
IMC EAGLE 2 SOLR-2ELC-10 Service and parts manual supplement