7
Labels
Read supplied instructions
before using. Failure to follow instructions
may result in serious injury or death. Never
modify product. Contact Manufacturer for
repair process.
USE: This device is only for use by one
person as a fall arrester. Only make
connections directly to dorsal
attachment point on safety harness.
Guard against swing-fall by keeping
lifeline vertically overhead. Ensure
that connection to anchorage is
secured properly before use. Avoid
lifeline contact with sharp or
abrasive edges and surfaces. May
be used as a component of a PFAS
in HLL applications. Design, installation,
and utilization of HLLs must be
supervised by a Qualified Person. Not
suitable for horizontal use. Competent
Person must calculate fall clearance
prior to use; fall clearance calculations
must include considerations for swing fall.
Clearance numbers specified based on lifeline installed
vertically overhead and in-line with worker.
INSPECTION: Prior to each use, check locking
(pull sharply to test) and retraction
function. Inspect for signs of
deployment, defects or damage to
housing, lifeline (inspect full length),
connectors, or missing parts. Inspect
impact indicator - see instruction manual.
Ensure presence and legibility of all
labels. Inspection by Competent Person
required at least every 12 months.
Immediately remove from service in
event of failed inspection, or if unit is
subjected to a fall.
User Weight Range (including tools and
equipment):
(Non-LE Use - Anchor at or above dorsal
D-ring): 100-420 lb (45-191 kg)
(LE Use - Anchor below dorsal D-ring): 130-310 lb
(59-141 kg)
Maximum Arrest Force: 1,800 lb (8 kN)
Average Arrest Force: 900 lb (4 kN)
Min Setback Distance From Edge: 0’
Maximum Arresting Distance: 3 ft 6 in (1,1 m)
Maximum Free Fall (LE): 5’ (1,5 m) | (Non-LE): Not Permitted
Minimum Require d Fall Clearance (LE): 17 ft (5,2 m) | (Non-LE): 7 ft (2,1 m)
Lifeline Material: Galvanized Steel | Length: 50 ft (15,2 m)
Rev: F
LOT #
Mfg. Date
Part #
Serial #
10917
HEIGHT SAFETY.
SIMPLIFIED.
Date of Manufacture Lot # Serial #Part #
Date:
Initials:
Date of First Use:
WARNING
guardianfall.com
90593 Rev. F
Designed, Assembled,
and Tested in USA
DO NOT REMOVE LABELS
10927
Label Stock:
MacTac REBEL 4MIL MAT TE PVC HT PRINT RB528H
Laminate:
MacTac PERMAFLEX 5MIL LUSTRE CLEAR PVC PERM LAM PF6315
PANTONE® Process Black
C0 M0 Y0 K0
R0 G0 B0
#000000
PANTONE® 7549
C0 M32 Y100 K0
R253 G181 B21
#FCB414
White
C0 M0 Y0 K0
R255 G250 B250
#FFFFFF
Part#: 90470
Rev: H
HALO
Self-Retracting Lifeline
OSHA 1926.502 & 1910.140
Se puede utilizar en aplicaciones borde expuesto
Suitable for
LEADINGEDGE
Label Stock:
MacTac REBEL 4MIL MAT TE PVC HT PRINT RB528H
Laminate:
MacTac PERMAFLEX 5MIL LUSTRE CLEAR PVC PERM LAM PF6315
PANTONE® Process Black
C0 M0 Y0 K0
R0 G0 B0
#000000
PANTONE® 7549
C0 M32 Y100 K0
R253 G181 B21
#FCB414
White
C0 M0 Y0 K0
R255 G250 B250
#FFFFFF
90470 Rev. H
GUARDIAN
HALO
Self-Retracting Lifeline OSHA 1926.502 & 1910.140 WARNING!
Not suitable for leading edge use Nunca deben usarse en aplicaciones de borde expuesto
2
1
1
WARNING! Read supplied instructions before using. Failure to follow instructions may result in serious injury or death. Never
modify product. Contact Manufacturer for repair process. USE: This device is only for use by one person as a fall arrester. Only
make connections directly to dorsal attachment point on safety harness. Guard against swing-fall by keeping lifeline vertically
overhead. Ensure that connection to anchorage is secured properly before use. Avoid lifeline contact with sharp or abrasive
edges and surfaces. May be used as a component of a PFAS in HLL applications. Design, installation, and utilization of HLLs
must be supervised by a Qualified Person. Not suitable for horizontal use. Competent Person must calculate fall clearance
prior to use; fall clearance calculations must include considerations for swing fall. Clearance numbers specified based on
lifeline installed vertically overhead and in-line with worker.
INSPECTION: Prior to each use, check locking (pull sharply to test) and retraction function. Inspect for signs of deployment,
defects or damage to housing, lifeline (inspect full length), connectors, or missing parts. Inspect impact indicator - see
instruction manual. Ensure presence and legibility of all labels. Inspection by Competent Person required at least every 12
months. Immediately remove from service in event of failed inspection, or if unit is subjected to a fall. User Weight Range
(including tools and equipment):(Non-LE Use - Anchor at or above dorsal D-ring): 100-420 lb (45-191 kg) (LE Use - Anchor
below dorsal D-ring): 130-310 lb (59-141 kg) Maximum Arrest Force: 1,800 lb (8 kN) Average Arrest Force: 900 lb (6 kN) Min
Setback Distance From Edge: 0’ Maximum Arresting Distance: 42” (1,1 m) Maximum Free Fall (LE): 5’ (1,5 m) | (Non-LE): Not
Permitted Minimum Required Fall Clearance (LE): 17 ft (5,2 m) | (Non-LE): 7 ft (2,1 m) Lifeline Material: Galvanized Steel |
Length: 50 ft (15,2 m) Part#: 90593 Rev: F
LOT # Mfg. Date Part # 10927 Serial # HEIGHT SAFETY.SIMPLIFIED.
guardianfall.com
Part # Date of Manufacture Lot # Serial #
Date: Initials: Date of First Use: