Fig. 1
KIT COLLETTORE IDRAULICO CALDAIA AG
GIUNTIVA VICTRIX PRO 35  55
COD. 3.023954
IT IE
IL PRESENTE FOGLIO È DA LASCIARE ALL'UTENTE ABBINA-
TO AL LIBRETTO ISTRUZIONI DELLA CALDAIA
HYDRAULIC MANIFOLD KIT WITH ADDI
TIONAL BOILER VICTRIX PRO 35  55
COD. 3.023954
THIS SHEET MUST BE LEFT WITH THE USER ALONG WITH
THE BOILER INSTRUCTION BOOK
Hydraulic manifold kit Hydraulic manifold kit
Avvertenze generali.
Tutti i prodotti sono protetti con idoneo imballaggio da trasporto.
Il materiale deve essere immagazzinato in ambienti asciutti ed al
riparo dalle intemperie.
Il presente foglio istruzioni contiene informazioni tecniche relative
all’installazione del kit. Per quanto concerne le altre tematiche corre-
late all’installazione del kit stesso (a titolo esemplicativo: sicurezza
sui luoghi di lavoro, salvaguardia dell’ambiente, prevenzioni degli
infortuni), è necessario rispettare i dettami della normativa vigente
ed i principi della buona tecnica.
L’installazione o il montaggio improprio dell’apparecchio e/o dei
componenti, accessori, kit e dispositivi potrebbe dare luogo a pro-
blematiche non prevedibili a priori nei confronti di persone, animali,
cose. Leggere attentamente le istruzioni a corredo del prodotto per
una corretta installazione dello stesso.
L’installazione e la manutenzione devono essere eettuate in ottem-
peranza alle normative vigenti, secondo le istruzioni del costruttore e
da parte di personale abilitato nonché professionalmente qualicato,
intendendo per tale quello avente specica competenza tecnica nel
settore degli impianti, come previsto dalla Legge.
General warnings.
All products are protected with suitable transport packaging.
e material must be stored in dry environments and protected
against weathering.
is instruction manual provides technical information for install-
ing the kit. As for the other issues related to kit installation (e.g. safety
in the work site, environment protection, injury prevention), it is
necessary to comply with the provisions specied in the regulations
in force and principles of good practice.
Improper installation or assembly of the appliance and/or compo-
nents, accessories, kit and devices can cause unexpected problems
to people, animals and objects. Read the instructions provided with
the product carefully to ensure a proper installation.
Installation and maintenance must be performed in compliance with
the regulations in force, according to the manufacturer's instructions
and by authorised professionally qualied sta, intending sta with
specic technical skills in the plant sector, as envisioned by the Law.
Montaggio Kit.
Premontare sulla valvola a 3 vie (8) il raccordo (10) e il nipplo (4)
interponendo apposito materiale di tenuta quale stoppa o simili.
Premontare sulla valvola di intercettazione impianto (11) il raccordo
(10) interponendo apposito materiale di tenuta quale stoppa o simili.
Premontare sulla valvola di non ritorno (3) il nipplo (4) interpo-
nendo apposito materiale di tenuta quale stoppa o simili.
Collegare la valvola di non ritorno (3) al tronchetto (9).
Attenzione: durante il montaggio della valvola di non ritorno (3)
assicurarsi che la freccia riportata sul corpo della stessa sia rivolta
verso il kit collettore idraulico come indicato in gura 2. Assicurarsi
inoltre di interporre sul letto di collegamento apposito materiale
di tenuta quale stoppa o simili.
Collegare sulla mandata (M) della caldaia (12) la valvole a 3 vie (8)
premontata in precedenza, interponendo la guarnizione (1).
Collegare sul ritorno (R) della caldaia (12) la valvola di intercettazio-
ne (11) premontata in precedenza, interponendo la guarnizione (1).
N.B.: montare le valvole (11 e 8) come indicato in g. 2.
Collegare il tubo coibentato (2) sulla valvola (8) e il tubo coibentato
(5) sulla valvola (11) interponendo la guarnizione (1).
Collegare il tronchetto mandata (9) provvisto di valvola di non
ritorno, al tubo coibentato (2) e il tronchetto ritorno (9) al tubo
coibentato (5). Eseguire il collegamento rispettando la disposizione
rappresentata in gura 2 e interponendo le guarnizioni (1) e (6).
Dopo il 1° collaudo in temperatura vericare il serraggio di tutte
le tubazioni.
N.B.: i componenti a valle dell'impianto quali vaso d'espansione
etc... vanno dimensionati in base alla portata dell'impianto.
Nel caso di montaggio del kit con uscite libere sul lato sinistro è
necessario eseguire l'installazione come rappresentato in gura 3.
Attenzione: i generatori modulari, ovvero installati in cascata
(batteria) con un kit d'allacciamento originale, devono conside-
rarsi un apparecchio unico, che assume il numero di matricola
(numero di fabbrica) del generatore più vicino ai dispositivi di
sicurezza INAIL.
Attenzione: le caldaie VICTRIX PRO hanno un grado di isola-
mento elettrico IPX5D e possono essere installate anche all'esterno
senza bisogno di protezioni aggiuntive, è opportuno comunque se
installate all'esterno coibentare le relative tubazioni e proteggere
dagli agenti atmosferici i kit.
Le caldaie devono essere installate nelle congurazioni e con i propri
kit di batteria e sicurezza originali.
La ditta declina ogni responsa-
bilità qualora l'installatore non utilizzi i dispositivi ed i kit originali
approvati INAIL o li utilizzi impropriamente.
N.B.: prima di chiudere i rubinetti di intercettazione impianto o le
valvole 3 vie, la caldaia deve essere spenta.
N.B.: il kit collettore idraulico caldaia aggiuntiva non deve essere
collegato ad una caldaia singola.
Kit Assembly.
Pre-assemble the tting (10) and the nipple (4) on the 3-way valve
(8) by interposing suitable sealing material such as oakum or similar.
Pre-assemble the tting (10) on the system shut-o valve (11) by
interposing suitable sealing material such as oakum or similar.
Pre-assemble the nipple (4) on the check valve (3) by interposing
suitable sealing material such as oakum or similar.
Connect the check valve (3) to the pin (9).
Attention: when installing the check valve (3) make sure that the
arrow on the casing faces the hydraulic manifold kit as shown in
gure 2. Also make sure to interpose suitable sealing material such
as oakum or similar on the connection thread.
Connect the 3-way valves (8), pre-assembled earlier, on the supply
(M) of the boiler (12) and interpose the gasket (1).
Connect the shut-o valve (11), pre-assembled earlier, on the return
(R) of the boiler (12) and interpose the gasket (1).
N.B.: assemble the valves (11 and 8) as shown in g. 2.
Connect the insulated pipe (2) on the valve (8) and the insulated
pipe (5) on the valve (11) and interpose the gasket (1).
Connect the supply pin (9) equipped with the check valve to the
insulated pipe (2) and the return pin (9) to the insulated pipe (5).
Make the connection respecting the arrangement shown in gure
2 and interposing the gaskets (1) and (6).
Aer the 1st temperature test, check the tightness of all the pipes.
N.B.: the components downstream of the system, such as the expan-
sion tank, must be sized according to the ow rate of the system.
If assembling the kit with free outputs on the le side, perform the
installation as shown in gure 3.
Attention: the modular generators, i.e. installed in cascade (set)
with an original connection kit, must be considered a unique
appliance, which assumes the serial number (factory number)
of the generator nearest to the INAIL safety devices.
Attention: the VICTRIX PRO boilers have an IPX5D electric
insulation rating and can also be installed outdoors, without ad-
ditional protections. However, if installed outdoors, the relevant
piping should be insulated and the kit protected from the elements.
e boilers must be installed in the congurations and with their
own original set and safety kits.
Te factory declines all liability
whenever the installer does not use the devices and INAIL-approved
original kits or uses them improperly.
N.B.: before closing the system cut-o cocks or the 3-way valves
(3), the boiler must be switched o.
N.B.: the additional hydraulic manifold kit must not be connected
to an individual boiler.
Fig. 3
Fig. 2
USCITA SX
USCITA DX
Rif Descrizione componenti kit Qtà
1Guarnizione 44x34x2 6
2Curva corta a 90° di collegamento mandata coibentata 1
3Valvola di non ritorno 1
4Nipplo 2
5Curva lunga a 90° di collegamento ritorno coibentata 1
6Guarnizione 72x55x2 2
7Tappo 2
8Corpo valvola 3 vie 1
9Collettore G2" 1/2 coibentato 2
10 Raccordo ssaggio valvola 2
11 Rubinetto a sfera 1
M - Mandata impianto
R - Ritorno impianto
1
10
8
1
1
M
R12
10
11
1
5
1
G2"1/2
7
7
G2"1/2
6
6
1
4
3
4
2
A
B
9
RIGHT OUTLET
LEFT OUTLET
Ref. Kit components description Qty
144x34x2 gasket 6
2Short 90° bend for the insulated supply connection 1
3Check valve 1
4Nipple 2
5Long 90° bend for the insulated return connection 1
672x55x2 gasket 2
7Plug 2
83-way valve casing 1
9Insulated manifold G2" 1/2 2
10 Valve xing tting 2
11 Ball valve 1
M - System ow
R - System return
COD. 1.035621 REV. ST.000238/000

This manual suits for next models

2

Other Immergas Boiler Supplies manuals

Immergas 3.021378 User manual

Immergas

Immergas 3.021378 User manual

Immergas VICTRIX PRO V2 User manual

Immergas

Immergas VICTRIX PRO V2 User manual

Immergas VICTRIX PRO 35 V2 SET User manual

Immergas

Immergas VICTRIX PRO 35 V2 SET User manual

Immergas VICTRIX SUPERIOR KIT User manual

Immergas

Immergas VICTRIX SUPERIOR KIT User manual

Immergas VICTRIX PRO 35 V2 SET User manual

Immergas

Immergas VICTRIX PRO 35 V2 SET User manual

Immergas 3.032852 User manual

Immergas

Immergas 3.032852 User manual

Immergas Victrix TT Series Product manual

Immergas

Immergas Victrix TT Series Product manual

Immergas Victrix Superior KW X User manual

Immergas

Immergas Victrix Superior KW X User manual

Immergas 3.018911 User manual

Immergas

Immergas 3.018911 User manual

Immergas 3.023960 User manual

Immergas

Immergas 3.023960 User manual

Immergas 3.031186 Product manual

Immergas

Immergas 3.031186 Product manual

Immergas 3.014083 User manual

Immergas

Immergas 3.014083 User manual

Immergas 3.032264 Product manual

Immergas

Immergas 3.032264 Product manual

Immergas 3.015266 User manual

Immergas

Immergas 3.015266 User manual

Immergas 3.020355 User manual

Immergas

Immergas 3.020355 User manual

Immergas Victrix Pro 35-55 User manual

Immergas

Immergas Victrix Pro 35-55 User manual

Immergas 3.030323 User manual

Immergas

Immergas 3.030323 User manual

Immergas 3.031483 Product manual

Immergas

Immergas 3.031483 Product manual

Immergas 3.026302 User manual

Immergas

Immergas 3.026302 User manual

Immergas 3.012944 User manual

Immergas

Immergas 3.012944 User manual

Immergas VICTRIX PRO 35 V2 Setup guide

Immergas

Immergas VICTRIX PRO 35 V2 Setup guide

Immergas 3.021377 User manual

Immergas

Immergas 3.021377 User manual

Immergas INAIL VICTRIX PRO 80 User manual

Immergas

Immergas INAIL VICTRIX PRO 80 User manual

Immergas 3.020934 User manual

Immergas

Immergas 3.020934 User manual

Popular Boiler Supplies manuals by other brands

McDonnell & Miller GuardDog RB-24E instruction manual

McDonnell & Miller

McDonnell & Miller GuardDog RB-24E instruction manual

Beretta B23 manual

Beretta

Beretta B23 manual

Tekmar Boiler Control 275 Installation & operation manual

Tekmar

Tekmar Boiler Control 275 Installation & operation manual

TriangleTube PSRKIT36 instructions

TriangleTube

TriangleTube PSRKIT36 instructions

Centrometal Cm Pelet-set 90 Technical instructions

Centrometal

Centrometal Cm Pelet-set 90 Technical instructions

Vapac VapaNet Operation manual

Vapac

Vapac VapaNet Operation manual

JJM Boiler Works NB Series Installation operation & maintenance

JJM Boiler Works

JJM Boiler Works NB Series Installation operation & maintenance

Buderus GB162 installation instructions

Buderus

Buderus GB162 installation instructions

Bryant 246 Product data

Bryant

Bryant 246 Product data

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.